Displaying publications 1 - 20 of 133 in total

Abstract:
Sort:
  1. Chong CS, Ahmad GU
    Health Phys, 1982 Aug;43(2):272-3.
    PMID: 7129886
    Matched MeSH terms: Gamma Rays
  2. Hu SJ, Koo WK, Tan KL
    Health Phys, 1984 Feb;46(2):452-5.
    PMID: 6693279
    Matched MeSH terms: Gamma Rays
  3. Chong CS, Chong HY, Fun HK, Leong LS
    Health Phys, 1985 Nov;49(5):1008-10.
    PMID: 4066326
    Matched MeSH terms: Gamma Rays
  4. Bradley DA, Ng KH, Aziz YB
    Int J Rad Appl Instrum A, 1988;39(5):439-40.
    PMID: 2840420
    The utility of a phantom material, based on SMR(L) [Standard Malaysian Rubber] grade natural rubber and a formulation used for the proprietary rubber phantom-material, Temex, has been examined for the 1-MeV photon-Measurement has also been performed with 60-keV photons using the radionuclide 241Am. At photon-therapy energy levels the measured response, when compared with tabulated central-axis percentage depth doses for the defined measuring conditions, produces everywhere (in the range 1-19 cm depth) better than 2% deviation. The favourable measured response characteristics combined with the ease of processing and casting the phantom material provide the basis for useful radiotherapy machine calibration and anthropomorphic dosimetry measurements. The measured mass-attenuation coefficient, at 60keV, of 0.204 cm2 g-1 (+/- 3%) is in close agreement with tabulated values for water (0.2055 cm2 g-1).
    Matched MeSH terms: Gamma Rays
  5. Bahari IB, Noor FM, Daud NM
    Mutat Res, 1994 Aug;313(1):1-5.
    PMID: 7519306
    An in vivo study on the effects of both physical (gamma-radiation) and chemical (mitomycin C) genotoxic agents was carried out with the catfish species, Clarias gariepinus. The fish were either exposed to gamma-radiation at doses of 0-9 Gy or injected intraperitoneally with mitomycin C at concentrations of 0-2 mg/kg. Micronucleated erythrocytes were sampled from 0 to 60 days post treatment. Data obtained showed a time-dependent response of the induction of micronucleated erythrocytes with both genotoxic agents. A linear dose-dependent increase was observed 2-4 days after treatment. These data show the importance of sampling time in the micronucleus assay with Clarias gariepinus.
    Matched MeSH terms: Gamma Rays
  6. Dolah MT, Samat SB, Kadni T
    Malays J Med Sci, 2000 Jan;7(1):47-53.
    PMID: 22844215
    Absorbed dose to water was measured with ionisation chambers NE 2561 (#267), NE 2581 (#334), NE 2571 (#1028), using the IAEA standard water phantom. The ionisation chamber was inserted in the water phantom at a reference depth dependent on the type of the radiation quality used. Three radiation qualities were used namely 1.25 MeV gamma ray, 6 MV x-rays and 10 MV x-rays. The values of the absorbed dose to water were determined by the N(K)- and N(X)- based methods, i.e with the use of IAEA, HPA, NACP, AAPM, NCRP and ICRU protocols. The aim of this study was to make an intercomparison of the results, by taking the IAEA protocol as a standard. The largest deviation contributed by any of these protocols was recorded for each quality. It was found that AAPM, NCRP and ICRU protocols contributed 0.94% for 1.25 MeV gamma ray, NACP contributed 2.12% for the 6 MV x-rays, and NACP contributed 2.35% for 10 MV x-rays. Since the acceptable limit of deviation set by the IAEA for this absorbed dose work is ± 3%, it is clear that the overall deviations obtained were all satisfactory.
    Matched MeSH terms: Gamma Rays
  7. Bradley DA, Dahlan KZ, Roy SC
    Appl Radiat Isot, 2000 Oct;53(4-5):921-8.
    PMID: 11003542
    High-energy electron (2.0 MV) and gamma irradiation (60Co) has been used to modify polymeric silicone fluids of initial viscosities in the range, 90-700 cSt. Doses of electron and gamma radiation were delivered at rates of 0.246 kGy s(-1) and 15 kGy h(-1), respectively, exposure times being adjusted to ensure energy deposition in the range 30-360 kGy. Measurements were made using a differential viscometer based on a Bose Institute design. In line with expectation, samples of greater initial molecular weight (and hence greater viscosity), were observed to be more susceptible to radiation induced cross-linking than those of lower molecular weight. The role of dose rate and oxygen diffusion in determining the extent of change is discussed.
    Matched MeSH terms: Gamma Rays
  8. Ramli AT, Hussein AW, Lee MH
    Appl Radiat Isot, 2001 Feb;54(2):327-33.
    PMID: 11200896
    Measurements of environmental terrestrial gamma radiation dose-rate (TGRD) have been made in Johore, Malaysia. The focus is on determining a relationship between geological type and TGRD levels. Data were compared using the one way analysis of variance (ANOVA), in some instances revealing significant differences between TGRD measurements and the underlying geological structure.
    Matched MeSH terms: Gamma Rays/adverse effects*
  9. Ramli AT, Rahman AT, Lee MH
    Appl Radiat Isot, 2003 Nov-Dec;59(5-6):393-405.
    PMID: 14622942
    A statistical prediction of terrestrial gamma radiation dose rate has been performed, covering the Kota Tinggi district of Peninsular Malaysia. The prediction has been based on geological features and soil types. The purpose of this study is to provide a methodology to statistically predict the gamma radiation dose rate with minimum surveying in an area. Results of statistical predictions using the hypothesis test were compared with the actual dose rate obtained by measurements.
    Matched MeSH terms: Gamma Rays*
  10. Iskandar SM, Elias S, Jumiah H, Asri MT, Masrianis A, Ab Rahman MZ, et al.
    Med J Malaysia, 2004 May;59 Suppl B:212-3.
    PMID: 15468893
    The radiation-response characteristics of polymetharylic acid gel dosimeter prepared with different concentrations of monomer and cross-linker is described in these studies. The dosimeters were prepared under the hypoxic condition in a glove box and were then irradiated with gamma-rays produced by Co-60 radionuclide that was generated at 1.25MeV energy. The irradiation took place at different doses ranged from 0Gy to 19Gy. Due to the radiation activities, chain-reaction polymerisation processes had taken place in the formation of polymethacrylic acid (PMAA) gel, which cause the dose response mechanism increased in the NMR relaxation rates of protons. It has been observed that for higher concentration of monomer and cross-linker, the polymerization rate was increased.
    Matched MeSH terms: Gamma Rays
  11. Mohd Asri MT, Elias S, Iskandar SM, Abd Halim S, Jumiah H, Zaki AR, et al.
    Med J Malaysia, 2004 May;59 Suppl B:139-40.
    PMID: 15468857
    The aim of this work was to study radiation and the effects of temperature on conductivity properties of polyvinyl alcohol (PVA)-based potassium hydroxide (KOH) and propylene carbonate (PC), where the ionic conduction preferentially occurs in the amorphous phase by free radicals ions through gamma-irradiation. Alkaline composite polymer electrolyte (ACPE) consisting of PVA, KOH and PC of different concentration ratios were prepared by solvent-casting technique. The ACPE were irradiated with different doses from 5 kGy up to 200 kGy. The conductivity properties of the electrolyte films were measured at different frequencies in the range 20 Hz to 1 MHz using LCR meter. The results showed that the conductivity properties were dependent on the radiation dose, temperature and the concentration of the polymer blends.
    Matched MeSH terms: Gamma Rays
  12. Ahmad Taufek Abdul Rahman, Ahmad Termizi Ramli, Abd. Khalik Wood
    MyJurnal
    Environmental radiation protection program is important in the effort to limit radiation dose to the public to be as low as reasonably achievable. As water is an important factor of transfer of radionuclide to human, therefore it is important to measure natural radionuclide concentrations in rivers. 20 water samples were collected randomly from the main rivers in Kota Tinggi district. The water samples collected were analysed using ICP-MS technique to determine uranium, thorium and potassium concentration in river water. Radionuclide concentrations obtained were compared with the terrestrial gamma radiation dose rate measured in the area. Significance of the results obtained is discussed.
    Matched MeSH terms: Gamma Rays
  13. Khairul Osman, Norashikin, M.S., Hing, Hiang Lian, Siti Fatimah Ibrahim, Seetha Khartini Abdul Wahab, Jamaludin Mohamed, et al.
    MyJurnal
    Radiotherapy causes various complications including low immunity. Past research has shown that the low immunity is due to the low amount of lymphocytes and consumption of citrullus vulgaris will alleviate this problem. Based on this a study was conducted to identify how citrullus vulgaris was able to produce radioprotection on the lymphocyte membrane. A total of 30 adult male Sprague-Dawley rats were used and divided into three equals groups of positive control, negative control and treatment. For seven days, positive control and negative control were force fed with normal saline of 40 ml/kg animal weight while the treatment group received 40 g/kg animal weight fresh juice of citrullus vulgaris daily. After a week positive control and treatment group were irradiated with 0.9 Gy gamma ray. Viable lymphocyte were determined using propidium iodine and acridine orange stain. Results clearly shows that positive control, negative and treatment group were significantly different at 34  3% , 80  2% and 71  2% respectively. SEM results shows that pores were present on the membrane of the positive control while the negative control had none. Similar results were also found on the treatment group. Based on the result it had shown that citrullus vulgaris had radioprotection properties and lymphocytes were destroyed by the formation of pores on their membrane. It is very likely that the radioprotection properties could be due to the presence of antioxidants particularly vitamin A, C and lycopene. In conclusion, citrullus vulgaris could be used as a safe radioprotection agent.
    Matched MeSH terms: Gamma Rays
  14. Yii, Mei Wo, Zaharuddin Ahmad
    MyJurnal
    The studies of ¹³⁷Cs content in the seawater surrounding Peninsular Malaysia had been carried out as part of the Malaysia Marine Radioactivity Database Project. The results of the measurement will serve as the baseline data and reference level to Malaysia. A numbers of sampling locations, including coastal and offshore at the East Coast (South China Sea) and West Coast (Straits of Malacca) of Peninsular Malaysia had been selected for the study. From each location at the coastal area, water samples were collected from the surface of the seawater. Meanwhile, for the offshore area, water samples have been collected at three different depths. Due to usual low concentration of ¹³⁷Cs in the marine environment, large volumes of seawater were collected and the co precipitation technique was employed to concentrate the ¹³⁷Cs. The activity of ¹³⁷Cs was determined by measuring the peak area under photo peak of the gamma spectrum at 661 keV, which is equivalent to the gamma intensity corrected to the HpGe detection efficiency and percentage of gamma ray abundance of the ¹³⁴Cs. At each study location, there were no significant differences for ¹³⁷Cs activities at 95% confidence interval. The activities of ¹³⁷Cs found to be quite uniformly distributed in the range of 2.33 to 5.00 Bq/m3and 1.76 to 4.76 Bq/m3for the South China Sea and the Straits of Malacca, respectively.
    Matched MeSH terms: Gamma Rays
  15. Phuah CS, Che Abd Rahim Mohamed, Zaharuddin Ahmad
    Concentration of Ra-226 and Ra-228 activities in water and sediment samples were measured using the Liquid Scintillation Counter (LSC) and High Purity Germanium Gamma Spectrometry (HPGe). respectively. Concentrations of Ra-226 activity in sediment samples range from 18.93 Bg/ kg to 236.06 Bq/kg and for Ra-228 activity range from 12.59 Bg/kg to 410.60 Bq/kg. Meanwhile, concentrations of Ra-226 activity obtained in water samples range from 0.064 Bg/L to 0.199 Bq/L. These data indicate, that the distribution of Ra-228 and Ra-226 in the study area were varied from one sampling stations to another and is probably related to the contents of suspended particles.
    Penentuan kepekatan aktiviti Ra-226 dan Ra-228 dalam sampel air dan sedimen dilakukan masing-masing dengan Pembilang Sintilasi Cecair (LSC) dan Spektrometri Gamma Germanium Lampau Tulen (HPGe). Kepekatan aktiviti Ra-226 dalam sampel sedimen adalah berjulat dari 18.93 Bg/kg hingga 236.06 Bq/kg dan kepekatan aktiviti Ra-228 berjulat dari 12.59 Bg/kg hingga 410.60 Bq/kg. Kepekatan aktiviti Ra-226 dalam sampel air yang diperolehi pula berjulat dari 0.064 Bg/L hingga 0.199 Bq/L. Ini menunjukkan taburan Ra-228 dan Ra-226 di kawasan kajian adalah berubah mengikut lokasi kajian dan berkemungkinan dipengaruhi oleh sifat kandungan bahan terampai.
    Matched MeSH terms: Gamma Rays
  16. Ramli AT, Sahrone S, Wagiran H
    J Radiol Prot, 2005 Dec;25(4):435-50.
    PMID: 16340071
    Environmental terrestrial gamma radiation dose rates were measured throughout Melaka, Malaysia, over a period of two years, with the objective of establishing baseline data on the background radiation level. Results obtained are shown in tabular, graphic and cartographic form. The values of terrestrial gamma radiation dose rate vary significantly over different soil types and for different underlying geological characteristics present in the study area. The values ranged from 54 +/- 5 to 378 +/- 38 nGy h(-1). The highest terrestrial gamma dose rates were measured over soil types of granitic origin and in areas with underlying geological characteristics of an acid intrusive (undifferentiated) type. An isodose map of terrestrial gamma dose rate in Melaka was drawn by using the GIS application 'Arc View'. This was based on data collected using a NaI(Tl) scintillation detector survey meter. The measurements were taken at 542 locations. Three small 'hot spots' were found where the dose rates were more than 350 nGy h(-1). The mean dose rates in the main population areas in the mukims (parishes) of Bukit Katil, Sungai Udang, Batu Berendam, Bukit Baru and Bandar Melaka were 154 +/- 15, 161 +/- 16, 160 +/- 16, 175 +/- 18 and 176 +/- 18 nGy h(-1), respectively. The population-weighted mean dose rate throughout Melaka state is 172 +/- 17 nGy h(-1). This is lower than the geographical mean dose rate of 183 +/- 54 nGy h(-1). The lower value arises from the fact that most of the population lives in the central area of the state where the lithology is dominated by sedimentary rocks consisting of shale, mudstone, phyllite, slate, hornfels, sandstone and schist of Devonian origin which have lower associated dose rates. The mean annual effective dose to the population from outdoor terrestrial gamma radiation was estimated to be 0.21 mSv. This value is higher than the world average of 0.07 mSv.
    Matched MeSH terms: Gamma Rays*
  17. Khairul Osman, Norashikin Md.Saad, Ezlan Elias, Siti Fatimah Ibrahim, Jamaludin Mohamed, Proomwichit, Proom
    MyJurnal
    A study was conducted to determine the radioprotective effects of Citrullus vulgaris on the lymphocyte sub-membrane particularly the actin layer. A total of 30 adult male Sprague-Dawley rats were divided into three equal groups of positive control, negative control and treatment. The positive and negative control groups were force fed with 40 ml/kg body weight of normal saline while the treatment group received 40 g/kg body weight of fresh juice of C. vulgaris daily. After a week the positive control and treatment groups were irradiated with 90 rad gamma radiation. Viable lymphocytes were determined using propidium iodine and acridine orange stain and observed under a fluorescent microscope. The percentage of viable lymphocytes of the treatment group (71.0%; p = 0.03) was significantly higher than the positive control group. The results showed that C. vulgaris possessed radioprotective effects because the lymphocyte actin was not damaged. The radioprotection effects could be due to the presence of antioxidants in C. vulgaris.
    Matched MeSH terms: Gamma Rays
  18. Burgess P
    J Radiol Prot, 2006 Jun;26(2):235-6; author reply 236-7.
    PMID: 16738419
    Matched MeSH terms: Gamma Rays*
  19. Supian Samat, Lee YK
    Sains Malaysiana, 2006;35:57-60.
    This note describes a method for the determination of the peak-to-total ratio, P/T versus gamma-ray energy of range 59.54-1836.03 keV of a HPGe detector. Results show that this ratio decreases with energy. To check the validity of these results, two approaches of results comparison, namely with the ratio reported by Cesana and Terrani in year 1989 and with the shape of total efficiency reported by Debertin and Helmer in year 1988 were taken. lt is shown that this method gives satisfactory results since the obtained values of P/T and the shape of the total efficiency curve were in good agreement with the reported works. The precautional step that need to be taken when dealing with energy 59.54 keV 241Am source and the reason for taking the total efficiency as the evaluation tool are given.
    Matched MeSH terms: Gamma Rays
  20. Noriszura Ismail, Abdul Aziz Jemain
    This study suggests the regression models of Lognormal, Normal and Gamma for the construction of an insurance scoring system. Comparison between Lognormal, Normal and Gamma regression models were also carried out, and the comparison were centered upon three main elements; fitting procedures, parameter estimates and structure of scores. The main advantage of utilizing a scoring system is that the system may be used by insurers to differentiate between good and bad insureds and thus allowing the profitability of insureds to be predicted.
    Matched MeSH terms: Gamma Rays
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links