Abstract:
Sort:
  1. Chang ET, Lim BH
    Med J Malaysia, 1989 Jun;44(2):160-6.
    PMID: 2626126
    The abuse of phenylbutazone among rheumatoid arthritis patients has recently become a subject of interest. Unscrupulous manufacturers take advantage of the miraculous analgesic property of phenylbutazone and deliberately add this toxic drug in their preparations without declaring its presence on the label. In a recent survey, many such illicit preparations were seized from Chinese medical halls in Johor and sent to the Department of Chemistry, Johor Bahru for analysis. Here a Gas Chromatograph Mass Selective Detector (GC-MSD) method was developed for the determination of phenylbutazone in illicit traditional preparations.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  2. Abdullah AS, Lajis NH, Bremner JB, Davies NW, Mustapha W, Rajion MA
    Vet Hum Toxicol, 1992 Apr;34(2):154-5.
    PMID: 1509678
    Spectroscopic examinations of purified extracts of the rumen content of sheep intoxicated by Brachiaria decumbens revealed the presence of a mixture of sapogenins, identified as 3-spirostanols. These isomeric steroid sapogenins (C27H44O3) are believed the toxic principles in causing toxicity in sheep after feeding on B. decumbens.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry
  3. Abdullah AR, Woon WC, Bakar RA
    Bull Environ Contam Toxicol, 1996 Jul;57(1):155-62.
    PMID: 8661474
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry
  4. Mustafa AM, Yap CG
    JUMMEC, 1998;3:63-64.
    Screening for drugs of abused were conducted by using Gas chromatography-Mass spectrometry (GCMS) fitted with capillary column. Urine samples supplied by Centre of Inmigrant Studies, University of Malaya were processed upon arrival and screened for the following drugs. Amphetamines, methamphetamines, aphedrine, hydroxy-amphetamines, ecstasy, benzamphetamines, codeine, morphine, heroine, cocaine and diazepam. The analysis was done using Shimadzu QP5000 Gas chromatograph-mass spectrometer by selected ion monitoring with BPX35 column, 15 m length, 0.32 ID, helium gas as carrier and quadropole mass detector at 1.60 kV electron gain. Analysis were performed using selected ion monitoring (SIM) mode and quantitations were based on area under the curve of individual standards at various concentrations. The method is sensitive to nanogram levels and are able to detect the presence of these drugs in both urine and plasma. From this study (n-100), none of the urine were found positive for the drugs screened. The major problem encountered were adulterated with water based on the clearness and the colour of the urine. Based on this suspicion we would like to suggest that the testing be done on blood samples as this would be more confirmative and quantitative.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry
  5. Roux D, Hadi HA, Thoret S, Guénard D, Thoison O, Païs M, et al.
    J Nat Prod, 2000 Aug;63(8):1070-6.
    PMID: 10978200
    Microtubule disassembly inhibitory properties have been established for the known polyisoprenylated benzophenones xanthochymol (1a) and guttiferone E (1b). The compounds were isolated from the fruits of Garcinia pyrifera collected in Malaysia. A structure-activity relationship study, including natural and semisynthetic derivatives, delineated some structural features necessary for the interaction with tubulin within this compound class.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry
  6. Xu J, Harrison LJ, Vittal JJ, Xu YJ, Goh SH
    J Nat Prod, 2000 Aug;63(8):1062-5.
    PMID: 10978198
    Leaf extracts of Callicarpa pentandra provided four new clerodane-type diterpenoids (1-4), of which 1, 2, and 4 have ring-A-contracted structures. Their structures and stereochemistry were established by spectral data interpretation, and for 3 also by single-crystal X-ray diffraction.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry
  7. Saleh MI, Koh YM, Tan SC, Aishah AL
    Analyst, 2000 Sep;125(9):1569-72.
    PMID: 11064937
    Salbutamol ¿2-(tert-butylamino)-1-[4-hydroxy-3- (hydroxymethyl)phenyl]ethanol¿, also known as albuterol, is clinically the most widely used beta 2-adrenoceptor agonist in the treatment of bronchial asthma. During this study, we evaluated liquid-liquid extraction (LLE) and solid-phase extraction (SPE) in order to develop a reliable extraction method followed by analysis using liquid chromatography and gas chromatography. An assay is described which involves SPE as the clean-up method followed by gas chromatography-mass spectrometry to determine salbutamol levels in human serum after oral administration. The SPE method requires the use of a hyper-cross-linked styrene-divinylbenzene bonded phase (ENV+) without involving any sample pre-treatment to obtain 60-65% recoveries for salbutamol and terbutaline as the internal standard. Distilled water and 1% trifluoroacetic acid in methanol were found to be the most suitable washing solvent and eluting solvent, respectively. A detection limit of 2 ng mL-1 was achieved by derivatization with N-methyl-N-trimethylsilyltrifluoroacetamide to form trimethylsilyl (TMS)-salbutamol (m/z 369) and TMS-terbutaline (m/z 356). The relationship between the ratio of the peak area of salbutamol to that of the internal standard and concentration was linear for the range tested (2-200 ng mL-1) and the correlation of coefficient was 0.9999 with a y-intercept not significantly different from zero. The inter-day relative standard deviation (RSD) was < 10% for all three concentrations. The intra-day RSD was 14% for 2 ng mL-1. This assay was then successfully applied to human serum samples obtained from clinical trials after oral administration of salbutamol.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry
  8. Permana D, Lajis NH, Mackeen MM, Ali AM, Aimi N, Kitajima M, et al.
    J Nat Prod, 2001 Jul;64(7):976-9.
    PMID: 11473441
    Two new prenylated compounds, the benzoquinone atrovirinone (1) and the depsidone atrovirisidone (2), were isolated from the roots of Garcinia atroviridis. Their structures were determined on the basis of the analysis of spectroscopic data. While compound 2 showed some cytotoxicity against HeLa cells, both compounds 1 and 2 were only mildly inhibitory toward Bacillus cereus and Staphylococcus aureus.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry
  9. Isobe KO, Tarao M, Zakaria MP, Chiem NH, Minh le Y, Takada H
    Environ Sci Technol, 2002 Nov 1;36(21):4497-507.
    PMID: 12433157
    This is the first report on fecal pollution using molecular markers in Southeast Asia where serious sewage pollution has occurred. A simple and sensitive analytical method using gas chromatography-mass spectrometry for 10 sterols in various environmental samples was developed to monitor extensive areas of tropical Asia. First, the method was applied to wastewater to confirm that >95% of sterols existed in the particulate phase. Then the approach was applied to a tropical Asian region, Malaysia and Vietnam, with a selection of 59 sampling stations in total. River water and sediment samples were collected and analyzed for chemical markers (coprostanol and other sterols) and microbiological markers (fecal coliforms and fecal streptococci). Particulate coprostanol concentrations ranged from <0.0001 to 13.47 microg/L in tropical river and estuarine waters, indicating severe fecal pollution in populous areas. Coprostanol concentrations in the sediments ranged from 0.005 to 15.5 microg/g-dry. The sedimentary coprostanol concentrations were lower than those reported in some urban areas of industrialized countries. This is probably because frequent heavy rain induces intensive input of eroded soil, which dilutes fecal material in river sediments. The relationship between the concentrations of fecal sterols and bacterial indicators was examined in an attempt to develop public health criteria for coprostanol levels applicable to the tropical region. Coprostanol concentrations of 30-100 ng/L or percent coprostanol levels of 2% corresponded to approximately 1000 fecal coliforms per 100 mL, which is set for secondary contact limit in many countries. These coprostanol concentrations were lower than those proposed as criteria in temperate countries, probably owing to greater survival of bacteria in warmer tropical waters. On the basis of these criteria, extensive monitoring of sediments suggests that poor sanitary conditions exist in most of the urbanized area of Malaysia and in several urban and rural sites in Vietnam.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry
  10. Halimah M, Tan YA, Aini K, Ismail BS
    J Environ Sci Health B, 2003 Jul;38(4):429-40.
    PMID: 12856925
    Improved methods for extraction and clean up of fluroxypyr residue in water have been established. Two methods of fluroxypyr extraction were used, namely, Direct Measurement of fluroxypyr and Concentration of fluroxypyr onto A Solid Phase Extraction (SPE) Adsorbent, followed by elution with solvent before determination of fluroxypyr. The recovery for Direct Measurement of fluroxypyr in water containing 8-100 microg L(-1), ranged from 86 to 110% with relative standard deviation of 0.7 to 2.15%. For the second method, three types of SPE were used, viz. C18, C18 end-capped and polyvinyl dibenzene (ISOLUTE ENV+). The procedure involved concentrating the analyte from fluroxypyr-spiked water at pH 3, followed by elution of the analyte with 4 mL of acentonitrile. The recovery of fluroxypyr from the spiked sample at 1 to 50 microg L(-1) after eluting through either C18 or C18 end-capped ranged from 40-64% (with relative standard deviation of 0.7 to 2.15) and 41-65% (with standard deviation of 1.52 to 11.9). The use of ISOLUTE ENV+, gave better results than the C18, C18 end-capped or the Direct Measurement Methods. The recovery and standard deviation of fluroxypyr from spiked water using ISOLUTE ENV+ ranged from 91-102% and 2.5 to 5.3, respectively.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  11. Tan BL, Mustafa AM
    Asia Pac J Public Health, 2003;15(2):118-23.
    PMID: 15038686
    Bisphenol A is the monomer used in the manufacture of polycarbonate. Bisphenol A is also known to mimic the female hormone estrogen. In this study, the possibility of the leaching of bisphenol A from polycarbonate babies' bottles and feeding teats was investigated. Bisphenol A was extracted from water samples exposed to the bottles and teats using liquid-liquid extraction. Bisphenol A was analysed by gas chromatograph-mass spectrometer with quadrapole detector in selected ion monitoring mode. Mean leaching of bisphenol A from 100 used babies' bottles when filled with water at 25 degrees C and 80 degrees C were 0.71 +/- 1.65 ng/cm2 (mean +/- standard deviation) and 3.37 +/- 5.68 ng/cm2 respectively. Mean leaching of bisphenol A from 30 new babies' bottles when filled with water at 25 degrees C and 80 degrees C were 0.03 +/- 0.02 ng/cm2 and 0.18 degrees 0.30 ng/cm2 respectively. Bisphenol A was observed to have leached from babies' feeding teats into 37 degrees C water ranged from non-detectable to 22.86 ng/g. The technique employed in this study is fast, reliable and economical.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry
  12. Radzi bin Abas M, Oros DR, Simoneit BR
    Chemosphere, 2004 May;55(8):1089-95.
    PMID: 15050806
    The haze episodes that occurred in Malaysia in September-October 1991, August-October 1994 and September-October 1997 have been attributed to suspended smoke particulate matter from biomass burning in southern Sumatra and Kalimantan, Indonesia. In the present study, polar organic compounds in aerosol particulate matter from Malaysia are converted to their trimethylsilyl derivatives and analyzed by gas chromatography-mass spectrometry in order to better assess the contribution of the biomass burning component during the haze episodes. On the basis of this analysis, levoglucosan was found to be the most abundant organic compound detected in almost all samples. The monosaccharides, alpha- and beta-mannose, the lignin breakdown products, vanillic and syringic acids and the minor steroids, cholesterol and beta-sitosterol were also present in some samples. The presence of the tracers from smoke overwhelmed the typical signatures of emissions from traffic and other anthropogenic activities in the urban areas.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry
  13. Abas MR, Omar NY, Maah MJ
    J Environ Sci (China), 2004;16(5):751-4.
    PMID: 15559805
    PM10 airborne particles and soot deposit collected after a fire incident at a chemical store were analyzed in order to determine the concentrations of polycyclic aromatic hydrocarbons (PAHs). The samples were extracted with 1:1 hexane-dichloromethane by ultrasonic agitation. The extracts were then subjected to gas chromatography-mass spectrometric (GC-MS) analysis. The total PAHs concentrations in airborne particles and soot deposit were found to be 3.27 +/- 1.55 ng/m3 and 12.81 +/- 24.37 microg/g, respectively. Based on the molecular distributions of PAHs and the interpretation of their diagnostic ratios such as PHEN/(PHEN + ANTH), FLT/(FLT + PYR) and BeP/(BeP + BaP), PAHs in both airborne particles and soot deposit may be inferred to be from the same source. The difference in the value of IP/(IP + BgP) for these samples indicated that benzo[g, h, i] perylene and coronene tend to be attached to finer particles and reside in the air for longer periods. Comparison between the molecular distributions of PAHs and their diagnostic ratios observed in the current study with those reported for urban atmospheric and roadside soil particles revealed that they are of different sources.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry
  14. Chan MP, Mohd MA
    Environ Toxicol, 2005 Feb;20(1):45-52.
    PMID: 15712329
    A method has been developed for the determination of trace levels of alpha-endosulfan, beta-endosulfan, endosulfan sulfate, and endosulfan diol in rat plasma and tissue samples. Endosulfan and its metabolites in the plasma samples were extracted with solid-phase extraction Chromabond-end-capped C18 cartridges and analyzed by a Shimadzu QP-5050A gas chromatograph-mass spectrometer (GCMS) with quadrupole detector in selected-ion-monitoring mode. The analysis of endosulfan and its metabolites in liver and kidney samples involved solvent extraction, Florisil solid-phase-extraction cleanup, and quantitation by GCMS. Recovery experiments for the plasma and tissue samples were conducted over concentration ranges of 10-100 ng mL(-1) and 100-1000 ng mL(-1), respectively. The method was applied to the analysis of trace levels of endosulfan and its metabolites in plasma and tissue samples collected from an animal study. Trace levels of alpha-endosulfan and beta-endosulfan in the ranges of undetectable to 3.11 microg g(-1) and undetectable to 1.19 microg g(-1), respectively, were detected in the kidney samples, whereas trace levels of endosulfan sulfate in the range of 0.02-0.22 microg g(-1) were detected in the liver samples of rats. Neither endosulfan nor its metabolites was detected in any of the plasma samples.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry
  15. Chan KB, Pakiam C, Rahim RA
    Bull Narc, 2005;57(1-2):249-56.
    PMID: 21338025
    Recently, the abuse of ketum, an indigenous psychoactive plant, has received a lot of attention in Malaysia. To help national law enforcement agencies control its abuse, the laboratory of the Forensic Division has developed a procedure for its positive identification. Botanical identification may not be practical or conclusive, owing to the wide range of ketum materials available on the market, including dry macerated leaves, powdered leaves and drinks. In order to confirm that a substance is, in fact, ketum or that a preparation is derived from ketum, gas chromatography-mass spectrometry is used to definitively identify the presence of the psychoactive principle mnitragynine.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods
  16. Wong FC, Ahmad M, Heng LY, Peng LB
    Talanta, 2006 Jun 15;69(4):888-93.
    PMID: 18970653 DOI: 10.1016/j.talanta.2005.11.034
    An optical biosensor consisting of a chromoionophore (ETH5294) (CM) doped sol-gel film interfaced with another sol-gel film immobilized with acetylcholinesterase (AChE) was employed to detect the insecticide dichlorvos. The main advantage of this optical biosensor is the use of a sol-gel layer with immobilized CM that possesses lipophilic property. The highly lipophilic nature of the CM and its compatibility with the sol-gel matrix has prevented leaching, which is frequently a problem in optical sensor construction based on pH indicator dyes. The immobilization of the indicator and enzyme was simple and need no chemical modification. The CM layer is pH sensitive and detects the pH changes of the acetylcholine chloride (AChCl) substrate when hydrolyzed by AChE layer deposited above. In the absence of the AChE layer, the pH response of the CM layer is linear from pH 6 to 8 (R(2)=0.98, n=3) and it showed no leaching of the lipophilic chromoionophore. When the AChE layer is deposited on top, the optical biosensor responds to AChCl with a linear dynamic range of 40-90mM AChCl (R(2)=0.984, n=6). The response time of the biosensor is 12min. Based on the optimum incubation time of 15min, a linear calibration curve of dichlorvos against the percentage inhibition of AChE was obtained from 0.5 to 7mg/L of dichlorvos (17-85% inhibition, R(2)=0.991, n=9). The detection limit for dichlorvos was 0.5mg/L. The results of the analysis of 1.7-6.0mg/L of dichlorvos using this optical biosensor agreed well with a gas chromatography-mass spectrometry detection method.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry
  17. Hu LF, Li SP, Cao H, Liu JJ, Gao JL, Yang FQ, et al.
    J Pharm Biomed Anal, 2006 Sep 18;42(2):200-6.
    PMID: 16242880
    Pogostemon cablin, originating in Malaysia and India, is cultivated in southern China including Guangdong and Hainan Province, which was called GuangHuoXiang to differentiate it from the HuoXiang of the north, the species Agastache rugosa, that it resembles. Essential oil of P. cablin mainly contributes to the pharmacological activities and the therapeutic properties of the essential oils are directly correlated with their qualitative and quantitative composition. For controlling the quality, standard fingerprint of P. cablin collected from different regions was developed by using GC-MS. Nine compounds including beta-patchoulene, caryophyllene, alpha-guaiene, seychellene, beta-guaiene, delta-guaiene, spathulenol, patchouli alcohol and pogostone were identified among 10 main peaks in P. cablin. Hierarchical clustering analysis based on characteristics of 10 investigated peaks in GC profiles showed that 18 samples were divided into three main clusters, patchouliol-type, pogostone-type and an interim-type, which was the one between the two chemotypes. The simulative mean chromatogram for the three types P. cablin was generated using the Computer Aided Similarity Evaluation System. The fingerprint can help to distinguish the substitute or adulterant, and further assess the differences of P. cablin grown in various areas of China.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry
  18. Tan KH, Tan LT, Nishida R
    J Chem Ecol, 2006 Nov;32(11):2429-41.
    PMID: 17082990 DOI: 10.1007/s10886-006-9154-4
    It is widely believed that most orchid flowers attract insects by using deception or chemical rewards in the form of nectar. Flowers of Bulbophyllum vinaceum produce a large array of phenylpropanoids that lure tephritid fruit fly males and also act as floral reward, which the flies subsequently convert to pheromone components. The major floral volatile components identified are methyl eugenol (ME), trans-coniferyl alcohol (CF), 2-allyl-4,5-dimethoxphenol (DMP), and trans-3,4-dimethoxycinnamyl acetate, whereas the minor components are eugenol, euasarone, trans-3,4-dimethoxy cinnamyl alcohol, and cis-coniferyl alcohol. Among the various floral parts, the lip (which is held in a closed position up against the sexual organs) has the highest concentration of the major compounds. An attracted male fly normally lands on one of the petals before climbing up onto and forcing the "spring loaded" floral lip into the open position, hence exposing the floral sexual organs. The architecture and location of chemical attractants of the lip compel the fly to align itself along the lip's longitudinal axis in a precise manner. As the fly laps up the compounds and moves towards the base of the lip, it passes the point of imbalance causing the lip to spring back to its normal closed position. The fly is catapulted headfirst into the column cavity, and its dorsum strikes the protruding sticky base of the hamulus and adheres to it. The momentum of the fly and the structural morphology of the long stiff hamulus act to pry out the pollinia from its anther cover. Hence, the pollinarium (pollinia + hamulus) is detached from the flower and adhered to the fly's dorsum. In this unique mutualistic association, both species receive direct reproductive benefits--the flower's pollinarium is transported for cross pollination, and the fly is offered a bouquet of phenylpropanoids (synomone) that it consumes, converts, and/or sequesters as sex pheromonal components, thus enhancing sexual attraction and mating success.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry
  19. Man CN, Gam LH, Ismail S, Lajis R, Awang R
    PMID: 16908224
    Nicotine is a major addictive compound in cigarette. Its smoke is rapidly and extensively metabolized to several metabolites in human. Cotinine as a major metabolite of nicotine is commonly used as a biomarker to determine active and passive smokers. Cotinine has a longer half-life ( approximately 20 h) compared to nicotine ( approximately 2h). A simple, sensitive, rapid and high throughput GC-MS method was developed for simultaneous quantification of urinary nicotine and cotinine in passive and active smokers. In the sample preparation method, the analytes and internal standard were first basified and followed by liquid-liquid extraction. Upon completion, anhydrous sodium sulphate was added to the solvent mixture to trap moistures. The clear extract obtained was directly injected into GC-MS, operating under selective ion monitoring (SIM) mode. Calibration curves in the range of 0.5-5000 ng/mL of the analytes in urine matrix were established with linear correlation coefficients (r(2)) greater than 0.997. The limit of detection for both nicotine and cotinine were 0.20 ng/mL. The mean recoveries for nicotine and cotinine were 93.0 and 100.4%, respectively. The within- and between-assay accuracies were between 2.1 and 7.9% for nicotine and between 0.7 and 11.1% for cotinine. Within- and between-assay precisions of 3.3-9.5% for nicotine and 3.4-9.8% for cotinine were also achieved. The method can be used in routine assessment and monitoring of active smoking and exposure to environmental tobacco smoke. The applicability of the assay was demonstrated in a small-scale comparison study between smokers and non-smokers.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry/methods*
  20. Soh SC, Abdullah MP
    Environ Monit Assess, 2007 Jan;124(1-3):39-50.
    PMID: 16967208
    A field investigation was conducted at all water treatment plants throughout 11 states and Federal Territory in Peninsular Malaysia. The sampling points in this study include treatment plant operation, service reservoir outlet and auxiliary outlet point at the water pipelines. Analysis was performed by solid phase micro-extraction technique with a 100 microm polydimethylsiloxane fibre using gas chromatography with mass spectrometry detection to analyse 54 volatile organic compounds (VOCs) of different chemical families in drinking water. The concentration of VOCs ranged from undetectable to 230.2 microg/l. Among all of the VOCs species, chloroform has the highest concentration and was detected in all drinking water samples. Average concentrations of total trihalomethanes (THMs) were almost similar among all states which were in the range of 28.4--33.0 microg/l. Apart from THMs, other abundant compounds detected were cis and trans-1,2-dichloroethylene, trichloroethylene, 1,2-dibromoethane, benzene, toluene, ethylbenzene, chlorobenzene, 1,4-dichlorobenzene and 1,2-dichloro - benzene. Principal component analysis (PCA) with the aid of varimax rotation, and parallel factor analysis (PARAFAC) method were used to statistically verify the correlation between VOCs and the source of pollution. The multivariate analysis pointed out that the maintenance of auxiliary pipelines in the distribution systems is vital as it can become significant point source pollution to Malaysian drinking water.
    Matched MeSH terms: Gas Chromatography-Mass Spectrometry