Displaying publications 1 - 20 of 116 in total

Abstract:
Sort:
  1. Lie-Injo Luan Eng, Weitkamp LR, Kosasih EN, Bolton JM, Moore CL
    Hum. Hered., 1971;21(4):376-83.
    PMID: 5003129
    Matched MeSH terms: Gels
  2. Lie-Injo LE, Fix A, Bolton JM, Gilman RH
    Acta Haematol., 1972;47(4):210-6.
    PMID: 4625303
    Matched MeSH terms: Gels
  3. Zainudin BM, Rafia MH, Sufarlan AW
    Singapore Med J, 1993 Apr;34(2):148-9.
    PMID: 8266157
    Lignocaine spray for anaesthetising the nasal mucosa for fibreoptic bronchoscopy often causes discomfort to the patient. We compared two techniques of applying nasal topical anaesthesia using either lignocaine spray (group A: 25 patients) or gel (group B: 30 patients) to assess patients' tolerance to the procedure. Both groups received 100 mg of lignocaine in the nostril, 40-50 mg to oropharynx, 120 mg to vocal cords and 40-100 mg to trachea and bronchi. Throat anaesthesia was the most common unpleasant part experienced by both groups of patients (34.5%), followed by examination of bronchi (30.6%) and nasal anaesthesia (21.8%). Significantly more patients in group A experienced discomfort or pain during nasal anaesthesia as compared to group B (p < 0.001). Patients' tolerance to the bronchoscopy was similar in both groups and the examination was performed satisfactorily in all patients. Thus, lignocaine gel is a simple technique, effective and less irritating as compared to lignocaine spray for topical nasal anaesthesia.
    Matched MeSH terms: Gels
  4. Roberts AD, Brackley CA
    J Dent, 1996 Sep;24(5):339-43.
    PMID: 8916648
    OBJECTIVES: A survey of general dental practitioners and dental surgery assistants was carried out to ascertain their preferences and opinions on powder-free hydrogel-coated gloves compared with starch-powdered gloves. The aim was to relate the survey findings to laboratory measurements of the frictional characteristics of glove inner surfaces and their water absorptive capability.

    METHODS: The survey was carried out using a questionnaire given to local dental practitioners. Glove friction and water absorption measurements were made using specially designed equipment.

    RESULTS: The survey showed that a selected group of dentist and dental surgery assistants preferred hydrogel-coated gloves, particularly for damp donning, durability and long-term wear comfort. Laboratory measurements showed that the hydrogel coating gave a low friction coefficient against damp skin. The coating was durable, and absorbed water more readily than other treatments.

    CONCLUSION: A survey of dental practitioners and dental surgery assistants and laboratory measurements indicates that hydrogel-coated gloves have superior properties, and are preferred to other non-sterile glove types.

    Matched MeSH terms: Gels
  5. Abdullah BJ, Mohd Yusof MY, Khoo BH
    Clin Radiol, 1998 Mar;53(3):212-4.
    PMID: 9528873
    Nosocomial infections are posing an increasingly serious problem in the hospital setting. With the increasing use of ultrasound in medical diagnosis, there is the potential for transmission of nosocomial infections via the ultrasound transducer and coupling gel. We evaluated the use of different membranes (three types of commercially available household cling film, condom, surgical glove and Opsite) applied over the ultrasound probe to determine if these were safe, convenient, cost-effective and did not impair the performance parameters of the ultrasound probe. None of the membranes impaired the physical scanning parameters using a Multi-Purpose Tissue/Cyst Phantom. The cling film was ideal for general use in terms of cost and convenience as well as safety. For sterile use the Opsite was better overall compared to the surgical glove, though it costs significantly more. The condom and surgical glove, though safe, were not very convenient to use for scanning.
    Matched MeSH terms: Gels
  6. Tan YT, Peh KK, Al-Hanbali O
    AAPS PharmSciTech, 2000;1(3):E24.
    PMID: 14727910
    This study examined the mechanical (hardness, compressibility, adhesiveness, and cohesiveness) and rheological (zero-rate viscosity and thixotropy) properties of polyethylene glycol (PEG) gels that contain different ratios of Carbopol 934P (CP) and polyvinylpyrrolidone K90 (PVP). Mechanical properties were examined using a texture analyzer (TA-XT2), and rheological properties were examined using a rheometer (Rheomat 115A). In addition, lidocaine release from gels was evaluated using a release apparatus simulating the buccal condition. The results indicated that an increase in CP concentration significantly increased gel compressibility, hardness, and adhesiveness, factors that affect ease of gel removal from container, ease of gel application onto mucosal membrane, and gel bioadhesion. However, CP concentration was negatively correlated with gel cohesiveness, a factor representing structural reformation. In contrast, PVP concentration was negatively correlated with gel hardness and compressibility, but positively correlated with gel cohesiveness. All PEG gels exhibited pseudoplastic flow with thixotropy, indicating a general loss of consistency with increased shearing stress. Drug release T50% was affected by the flow rate of the simulated saliva solution. A reduction in the flow rate caused a slower drug release and hence a higher T50% value. In addition, drug release was significantly reduced as the concentrations of CP and PVP increased because of the increase in zero-rate viscosity of the gels. Response surfaces and contour plots of the dependent variables further substantiated that various combinations of CP and PVP in the PEG gels offered a wide range of mechanical, rheological, and drug-release characteristics. A combination of CP and PVP with complementary physical properties resulted in a prolonged buccal drug delivery.
    Matched MeSH terms: Gels/chemistry*
  7. Iskandar SM, Elias S, Jumiah H, Asri MT, Masrianis A, Ab Rahman MZ, et al.
    Med J Malaysia, 2004 May;59 Suppl B:212-3.
    PMID: 15468893
    The radiation-response characteristics of polymetharylic acid gel dosimeter prepared with different concentrations of monomer and cross-linker is described in these studies. The dosimeters were prepared under the hypoxic condition in a glove box and were then irradiated with gamma-rays produced by Co-60 radionuclide that was generated at 1.25MeV energy. The irradiation took place at different doses ranged from 0Gy to 19Gy. Due to the radiation activities, chain-reaction polymerisation processes had taken place in the formation of polymethacrylic acid (PMAA) gel, which cause the dose response mechanism increased in the NMR relaxation rates of protons. It has been observed that for higher concentration of monomer and cross-linker, the polymerization rate was increased.
    Matched MeSH terms: Gels
  8. Mat Amin N
    Trop Biomed, 2004 Dec;21(2):57-60.
    PMID: 16493399
    Naegleria fowleri is a free-living amoeba, known as a causative agent for a fatal disease of the central nervous system (CNS) in man such as Primary amoebic meningoencephalitis (PAM). Factors contributing to its pathogenicity and its distribution in the environment have been investigated by previous researchers. In case of its pathogenicity, several enzymes such as phospolipase A and sphingomyelinase, have been proposed to probably act as aggressors in promoting PAM but no study so far have been conducted to investigate the presence of proteinase enzyme in this amoeba although a 56kDa cystein proteinase enzyme has been identified in Entamoeba histolytica as an important contributing factor in the amoeba's virulence. In this preliminary study, a pathogenic amoeba, Naegleria fowleri (strain NF3) was examined for the presence of proteinases. Samples of enzymes in this amoeba were analysed by electrophoresis using SDS-PAGE-gelatin gels. The results showed that this amoeba possesses at least two high molecular weight proteinases on gelatin gels; their apparent molecular weights are approximately 128 kDa and approximately 170 kDa. Band of approximately 128 kDa enzyme is membrane-associated and its activity is higher at alkaline pH compared with lower pH; at lower pH, its activity is greatly stimulated by DTT. The approximately 170 kDa band enzyme appears to be inactivated at pH 8.0, at lower ph its activity is higher and DTT-dependance. The activity of this enzyme is partially inhibited by inhibitor E-64 but markedly inhibited to antipain suggesting it belongs to the cysteine proteinase group.
    Matched MeSH terms: Gels
  9. Tay PYS, Lenton EA
    Med J Malaysia, 2005 Jun;60(2):151-7.
    PMID: 16114155
    This is a prospeve randomised study designed to clarify the impact of various luteal support regimes (HCG and progesterone) on progesterone profiles and pregnancy outcomes. This study involved subjects undergone down regulated. stimulated IVF cycles using various types of luteal support, namely: Cyclogest (n=35). Crinone gel (n=36), various doses of Utrogestan (n=55) and HCG (n=35). Various doses of Utrogestan (administered vaginally), Crinone gel (progesterone administered vaginally) and Cyclogest (progesterone administered rectally) supplementation induced similar end plasma progesterone concentrations ranging from 26 to 32 mmnl/l. These progesterone regimes produced no significant differences. Hence, the impact of exogenous proge,terone supplement was relatively trivial and did not 'stabilise' the sub-optimal luteal phase. In contrast, two small HCG injections during the early and mid-luteal phase possessed a much greater ability to 'stabilise' progesterone profiles. Despite this additional advantage, implantation and pregnancy rates with either HCG or progesterone supplements were similar. Although none of these forms of luteal support adequately 'normalised' luteal progesterone profiles, this did not appear to be detrimental to the process of implantation.
    Matched MeSH terms: Gels
  10. Chan KY, Lau CL, Adeeb SM, Somasundaram S, Nasir-Zahari M
    Plast Reconstr Surg, 2005 Sep 15;116(4):1013-20; discussion 1021-2.
    PMID: 16163087
    BACKGROUND: Hypertrophic scarring caused by sternotomy is prevalent among Asians. The effectiveness of silicone gel in scar prevention may influence the decision of surgeons and patients regarding its routine use during the postoperative period.

    METHODS: The authors conducted a randomized, placebo-controlled, double-blind, prospective clinical trial. The susceptibility to scar development varied among patients; therefore, sternal wounds were divided into the upper half and the lower half. Two types of coded gel prepared by an independent pharmacist were used on either half. Thus, selection and assessment biases and confounders were eliminated.

    RESULTS: One hundred wounds in 50 patients were randomized into two arms, 50 control and 50 silicone gels. The median age was 61 years and there were 34 men and 16 women. Ethnic distribution was 28 Malays, 18 Chinese, and four Indians. No side effect caused by the silicone gel was noted. Ninety-eight percent of patients had moderate to good compliance. The incidence of sternotomy scar was 94 percent. At the third month postoperatively, the silicone gel wounds were scored lower when compared with the control wounds. The differences were statistically significant in all parameters, including pigmentation (p = 0.02), vascularity (p = 0.001), pliability (p = 0.001), height (p = 0.001), pain (p = 0.001), and itchiness (p = 0.02).

    CONCLUSIONS: The effect of silicone gel in prevention of hypertrophic scar development in sternotomy wounds is promising. There are no side effects and patients' compliance is satisfactory. This study may popularize the use of silicone gel in all types of surgery to minimize the formation of hypertrophic scars in the early postoperative period.

    Matched MeSH terms: Silicone Gels/therapeutic use*
  11. Ong LB, Liza-Sharmini AT, Chieng LL, Cheong MT, Vengadasalam SR, Shin HC, et al.
    J Ocul Pharmacol Ther, 2005 Oct;21(5):388-94.
    PMID: 16245965
    The aim of this study was to determine the effectiveness of timolol gel-forming solution as a monotherapy and to compare the efficacy of timolol gel-forming solution morning instillation versus at night application in Asians with newly diagnosed open-angle glaucoma.
    Matched MeSH terms: Gels
  12. Abdullah J, Ahmad M, Heng LY, Karuppiah N, Sidek H
    Anal Bioanal Chem, 2006 Nov;386(5):1285-92.
    PMID: 17031625
    The stacked-film immobilization of 3-methyl-2-benzothiazolinone hydrazone (MBTH) in hybrid nafion/sol-gel silicate film and horseradish peroxidase (HRP) in chitosan, performed in order to allow the determination of phenolic compounds, was investigated via an optical method. The stacked films were deposited onto a microscope glass slide by a spin-coating technique. The quinone or free radical product formed by the enzymatic reactions of phenolic compounds interacts with MBTH to form azo-dye products, which can be measured spectrophotometrically at a wavelength of 500 nm. The color intensity of the product was found to increase in proportion to the phenolic concentration after 5 min of exposure. The response of the biosensor was linear over concentration ranges of 0.025-0.500, 0.010-0.070 and 0.050-0.300 mM for guaiacol, resorcinol and o-cresol, respectively, and gave detection limits of 0.010, 0.005 and 0.012 mM. The sensor exhibited good sensitivity and stability for at least two months.
    Matched MeSH terms: Gels
  13. Ahmad AL, Abd Shukor SR, Leo CP
    J Nanosci Nanotechnol, 2006 Dec;6(12):3910-4.
    PMID: 17256351
    Polymeric vanadium pentoxide gel was formed via the reaction of V2O5 powder with hydrogen peroxide. The polymeric vanadium pentoxide gel was then dispersed in alumina gel. Different vanadium loading composites were coated on alumina support and calcined at 500 degrees C for 1 hr. These composite layers were characterized using TGA, FT-IR, XRD, SEM, and Autosorb. It was found that the lamellar structure of polymerized vanadium pentoxide was retained in the inorganic matrix. Crystalline alumina in gamma phase was formed after calcinations. However, the vanadium-alumina mixed oxides are lack of the well defined PXRD peaks for polycrystalline V2O5. This is possibly because the vanadia species are highly dispersed in the alumina matrix or the vanadia species are dispersed as crystalline which is smaller than 4 nm. In addition, the imbedded polymeric vanadium oxide improved the specific area and average pore diameter of the composite layer.
    Matched MeSH terms: Gels/chemistry
  14. Karim AA, Toon LC, Lee VP, Ong WY, Fazilah A, Noda T
    J Food Sci, 2007 Mar;72(2):C132-8.
    PMID: 17995828
    Effects of phosphorus content (510 to 987 ppm) on the gelatinization and retrogradation of 6 potato cultivars (Benimaru, Hokkaikogane, Irish Cobbler, Konafubuki, Sakurafubuki, and Touya) were studied. Pasting properties were analyzed by RVA, thermal properties by DSC, and mechanical properties of the starch gels by TA. Phosphorus was positively correlated with swelling power (r= 0.84) and negatively correlated with solubility (r= 0.83). Phosphorus content showed significant effect on certain pasting properties of potato starch such as peak viscosity, breakdown, and setback. Phosphorus content showed a significant positive correlation with peak viscosity (r= 0.95) and breakdown (r= 0.90). Increasing concentration of phosphorus tends to decrease the setback. Phosphorus content had no influence on thermal properties and mechanical properties of potato starch gel.
    Matched MeSH terms: Gels/analysis; Gels/chemistry
  15. Leong LH, Kandaiya S, Seng NB
    Australas Phys Eng Sci Med, 2007 Jun;30(2):135-40.
    PMID: 17682403
    The oxidation of ferrous to ferric ions due to ionizing radiation has been used for chemical dosimetry since 1927. The introduction of metal indicator dye xylenol orange (XO) sensitises the measurement of ferric ion yield. A ferrous sulphate- agarose- xylenol orange (FAX) gel was prepared and the gel then exposed to dose ranging from 0.2 to 10 Gy using various high energy photon and electron beams from a linear accelerator. Some general characteristics of FAX such as energy dependence, optical density (OD)-dose relationship, reproducibility and auto-oxidation of ferrous ions were analysed. The radiation yield G of the gel was calculated for gels prepared in oxygen and in air and the values were 46.3 +/- 2.1 and 40.9 +/- 1.4 Fe3+ per 100 eV for photons respectively. However for stock gel which was kept for 5 days pre-irradiation the G value decreased to 36.6 +/- 1.1. The gel shows linearity in OD-dose relationship, energy independence and reproducibility over the dose range investigated. Auto-oxidation of ferrous ions resulted in optical density changes of less than 1.5% per day.
    Matched MeSH terms: Gels
  16. Ravindra P, Chan ES, Reddy KU
    Int J Food Sci Nutr, 2007 Nov;58(7):542-7.
    PMID: 17852467
    Extensive studies have been carried out on the effect of temperature and salt concentration on the theological behavior of whey proteins and different starches individually, but not on mixed dispersions of whey protein isolates and starches. In the present studies, the rheological behavior of cross-linked waxy maize starch and whey protein isolate mixed dispersions during heating at 60-85 degrees C was investigated. Further, the effect of CaCl2 (25-100 mM ionic strengths) on the gelatinization of these dispersions was determined. It was found that at a 2:3 ratio and a 3:2 ratio of cross-linked waxy maize starch to whey protein isolate mixed gels form a compatible networkmM concentration the solution viscosity was higher.
    Matched MeSH terms: Gels/chemistry*
  17. Mardziah CM, Sopyan I, Hamdi M, Ramesh S
    Med J Malaysia, 2008 Jul;63 Suppl A:79-80.
    PMID: 19024993
    Improvement of the mechanical properties of hydroxyapatite (HA) can be achieved by the incorporation of metal. In addition, incorporation of strontium ion into HA crystal structures has been proved effective to enhance biochemical properties of bone implant. In this research, strontium-doped HA powder was developed via a sol-gel method to produce extraordinarily fine strontium-doped HA (Sr-doped HA) powder. XRD measurement had shown that the powder contained hydroxyapatite phase only for all doping concentration except for 2%, showing that Sr atoms have suppressed the appearance of beta-TCP as the secondary phase. Morphological evaluation by FESEM measurement shows that the particles of the Sr-doped HA agglomerates are globular in shape with an average size of 1-2 microm in diameter while the primary particles have a diameter of 30-150 nm in average.
    Matched MeSH terms: Gels
  18. Lee JS, Lo YL, Chye FY
    This study was carried out to elucidate the effect of three types of cation (K+, Ca2+ and Na+) at various concentrations on the gelling properties of untreated Eucheuma cottoni, with the ultimate aim to explore the possibility of utilizing the seaweed in its natural form as gelling agent. Results obtained suggest that E. cottonii also exhibited the dramatic cation specificity of k-carrageenan, in which the dependence of gel strength follows the order: K+ > Ca2+ > Na+. As expected, cations addition exerts adverse effect on the syneresis, water holding capacity and freeze-thaw stability of the seaweed gel. Water holding capcity of the gel is however independent of the increased concentrations of K+(p>0.05). Storage duration and storage temperature significantly (p<0.05) affect the syneresis and water holding capacity of the gel. Among the cations, K+ appears to be better in improving the gel properties of the seaweed.
    Matched MeSH terms: Gels
  19. Yusof NA, Kadir WA
    PMID: 19010723 DOI: 10.1016/j.saa.2008.07.019
    Optical test strip based on the use of Br-PADAP as a sensitive reagent immobilised into sol-gel thin film for detection of Hg(II) in aqueous solution had been thoroughly carried out. It has a square-sensing zone (1.0 cm x 1.0 cm) containing the sensitive reagent necessary to produce response to trace level of mercury. This method offer sensitivity and simplicity in detecting Hg(II) as no prior treatment or extraction is required. A linear response was attained in the Hg(II) concentration in the range of 0.5-2.5 ppm with calculated limit of detection of 6.63 ppb. This method also showed a reproducible result with relative standard deviation (R.S.D.) of 2.15% and response time of approximately 5 min. Interference studies showed that Al(III), Co(II) and Ni(II) significantly interfered during the determination. The developed sensor has been validated against Atomic Absorption Spectroscopy method and proven comparable.
    Matched MeSH terms: Gels
  20. Gan CY, Cheng LH, Easa AM
    J Food Sci, 2009 Mar;74(2):C141-6.
    PMID: 19323728 DOI: 10.1111/j.1750-3841.2009.01053.x
    Soy protein isolate (SPI) gels were produced using single cross-linking agents (SCLA) of microbial transglutaminase (MTG) via incubation for 5 or 24 h (SCLA-MTG). When powdered SCLA-MTG gels were heated for 2 h with ribose (R2) (2 g/100 mL), dark brown gels were formed, and these were designated as combined cross-linking agent (CCLA) gels: MTG5(R2) and MTG24(R2). The results showed that the levels of Maillard-derived browning and cross-links of MTG5(R2) and MTG24(R2) gels were significantly (P < 0.05) lower than a control gel produced without MTG (SCLA-R2) even though the percentage of ribose remaining after heating of these gels was similar, indicating that a similar amount of ribose was consumed during heating. epsilon-(gamma-glutamyl)lysine bonds formed during incubation of SPI with MTG may have reduced the free amino group of SPI to take part in the Maillard reaction; nevertheless, ribose took part in the Maillard reaction and initiated the Maillard cross-linkings within the CCLA gels.
    Matched MeSH terms: Gels
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links