Displaying publications 1 - 20 of 68 in total

Abstract:
Sort:
  1. Malik Z, Muhammad N, Kaleem M, Nayyar M, Qazi AS, Butt DQ, et al.
    ACS Appl Bio Mater, 2023 Feb 20;6(2):425-435.
    PMID: 36700919 DOI: 10.1021/acsabm.2c00644
    This study aims to synthesize and characterize lignin-decorated zinc oxide nanoparticles before incorporating them into resin-modified glass ionomer cement (RMGIC) to improve their anticariogenic potential and mechanical properties (shear bond strength and microhardness). Probe sonication was used to synthesize lignin-decorated zinc oxide nanoparticles which were then characterized via scanning electron microscopy, Fourier transform infrared spectroscopy, and X-ray diffraction. Following characterization, these were incorporated in RMGIC (Gold label, Fuji II LC). Three major groups, experimental group A (EGA), experimental group B (EGB), and control group (CG), were outlined. EGA and EGB were divided into numbered subgroups based on the ascending concentrations of nanoparticles (5, 10, and 15%) of lignin-coated zinc oxide and zinc-oxide, respectively. CG served as a control and comprised cured RMGIC samples without any incorporation. Anticariogenic analysis was conducted on experimental RMGIC samples via disk-diffusion (n = 3) and direct contact test (n = 3) against Streptococcus mutans (ATCC 25175). Optical density values for days 1, 3, and 5 were recorded via a UV-Vis spectrophotometer. A shear bond strength test was performed using 35 premolars. The adhesive remnant index was used to estimate the site of bond failure. For the Vickers microhardness test (n = 3), 100 g of load at 10 s dwell time was set. Atomic absorption spectroscopy was performed over 28 days to determine the release of zinc from the samples. All tests were analyzed statistically. The anticariogenic potential of EGA and EGB was significantly greater (p ≤ 0.05) than that of the control. The shear bond strength test reported the highest value for EGA15 with all groups exhibiting failure at the bracket/RMGIC interface. The microhardness of EGA15 yielded the highest value (p ≤ 0.05). Release kinetics displayed a steady release with EGB15 exhibiting the highest value. The EGA and EGB samples displayed good anticariogenic potential, which was sustained for 28 days without any deleterious effect on the shear bond strength and microhardness.
    Matched MeSH terms: Glass Ionomer Cements/chemistry
  2. Alhajj MN, Salim NS, Johari Y, Syahrizal M, Abdul-Muttlib NA, Ariffin Z
    Acta Stomatol Croat, 2020 Sep;54(3):263-272.
    PMID: 33132389 DOI: 10.15644/asc54/3/4
    Objective: Endodontically treated teeth may require posts for retaining the core and replacing the coronal structures that have been lost. The objective of this study was to evaluate and compare the push-out bond strength between different types of post cemented with different types of luting cement at different types of root level.

    Materials and Methods: In this in-vitro study, a total of 48 single-rooted permanent human teeth were decoronated, and the roots were treated endodontically. Following post space preparation, the sample was divided into four groups (n= 12 each) based on the types of post and cement. Two different types of post [GC everStick®POST (ES) and Parapost® Fiber LuxTM (PF)], and two different types of cement [G-CEMTM (G), and RelyXTM Unicem (R)] were used according to the manufacturer's instructions. All roots were sectioned at the coronal and middle thirds with a thickness of 3±0.1mm. The Push-out bond strength (PBS) test was performed using a universal testing machine at a cross-head speed of 0.5mm/ min. The bond strength values were recorded, and the data were analyzed using the SPSS program. Apart from descriptive statistics, three-way ANOVA was used for the interaction of the independent variables (post, cement, and root level). For differences between the groups, the Mann-Whitney U test was used. A P-value of less than 0.05 was considered significant for all analyses.

    Results: Push-out bond strength of samples at the middle level (11.38±10.31 MPa), with PF posts (11.18±9.98 MPa), and of those luted with RelyXTM Unicem cement (13.26±8.73 MPa) was higher than that of their counterparts. The PBS means of RelyXTM Unicem cement at both root levels were much higher than PBS means of G-CEMTM cement. Three-way ANOVA test revealed a significant effect for each variable with a higher effect of cement (Sum of Squares= 1310.690; P< 0.001). No significant difference (P= 0.153) was found between the coronal and middle parts and between ES and PF posts (P= 0.058). However, a highly significant difference (P< 0.001) was found between RelyXTM Unicem and G-CEMTM cements.

    Conclusion: The type of cement had a significant effect on push-out bond strength with RelyXTM Unicem which had higher values than G-CEMTM. However, the type of post and root level had no significant effect on PBS, although Parapost® Fiber LuxTM and middle root level had higher values than their counterparts.

    Matched MeSH terms: Glass Ionomer Cements
  3. Sulaiman, E., Yeo, Y.M., Chong, Y.T.
    Ann Dent, 2007;14(1):39-45.
    MyJurnal
    Purpose of the study: The objective of this study was to investigate the flexural strengths of five commercially available tooth-coloured restorative materials – Alpha-Dent (composite resin, Dental Technologies Inc.), Solare Anterior (composite resin, GC), F2000 (polyacid-modified composite resin, 3M), Beautifil (giomer, Shofu) and Fuji II LC (resin- modified glass ionomer cement, GC] using the ISO 4049 specifications. Materials and Method: Ten specimens of (25±0.2)mm x (2±0.1)mm x (2±0.1)mm from each material were prepared at 22-23ºC using a customized metal mould. After light polymerization, the specimens were stored in distilled water at 37ºC for 24 hours. The specimens were subsequently blotted dry, measured and subjected to flexural testing using an Instron Universal Testing Machine with a crosshead speed of 0.5mm/min. The flexural strengths were calculated from the maximum load exerted on the specimens. Data were analysed using one way ANOVA and scheffe’s post-hoc multiple comparison tests at a significance level of 0.05.Results: The results showed that the mean flexural strengths of Beautifil, Solare Anterior and Alpha-Dent were above 80 MPa and those of F2000 and Fuji II LC were below 80 MPa. The results of one-way ANOVA and Scheffe’s post-host tests demonstrated that Beautifil had significantly higher mean flexural strength compared to Fuji II LC, F2000 and Alpha-Dent (P
    Matched MeSH terms: Glass Ionomer Cements
  4. Annuar, W.A., Abdullah, H.
    Ann Dent, 2003;10(1):-.
    MyJurnal
    This study is conducted to compare two resin luting cements (Rely XTMARC,3M and Compolute™ESPE) on their microleakage with one composite inlay system (Filtek™ Z250 Universal Restorative Materials, 3M). Thirty conventional inlays, Class II MOIDO cavity with gingival margin I mm above the cementoenamel junction, were prepared in premolar teeth. The composite inlays were fabricated directly on the prepared teeth using layering technique. Fifteen of the inlays were cemented with RelyTMX ARC and fifteen with Compolute™ (ESPE). The specimens were kept at 370 C for 10 days before thermocycling and immersed in methylene blue 2% solution for 24 hours. The teeth were sectioned mesio-distally. The site and degree of leakage of each section was scored using a visual scoring system under a stereomicroscope at a magnification of 1.5X. Results showed that there was no significant difference in'leakage extent (p>O.05), between Rely X™ARC and Compolute™. For both materials, leakage occurred most commonly within the enamel surface and between the cement-tooth interfaces. None of the leakage occurred between inlay - cement interface. There is no significant difference in the extent of leakage between Rely XTMARC compared to Compolute™.
    Matched MeSH terms: Glass Ionomer Cements
  5. Suhaida Sabdi, Wan Zaripah Wan Bakar, Adam Husein
    MyJurnal
    Some restorative materials are susceptible to erosion but whether it also causes microleakage is still questionable. The aim of this study was to assess the microleakage of few restorative materials after immersion in acidic solution. Standardized ‘U’ shaped cavity of 4mm diameter and 2mm depth were prepared on buccal or lingual surface of 52 human premolar and molar teeth. The teeth were divided into 4 groups which contains 13 samples and 3 controls for each and were restored either with Filtek Z250 (Group 1), Fuji IX (Group 2), Fuji II LC (Group 3), or Silverfill amalgam (Group 4).
    All surfaces were painted with nail varnish leaving only 2mm of tooth structure surrounding the restoration before the study samples were immersed in acidic solution, lemon juice (pH 2.74) and control samples in deionised distilled water for 24 hours. Surface photos for erosion were taken before immersion in methylene blue for 7 days. After sectioning, the assessment of dye penetration was done using Leica Imaging System DMLM (Germany). Photos showed that Fuji IX demonstrated severe erosion but no obvious changes were seen on other materials. Kruskal-Wallis test indicated that microleakage between all four groups were statistically significant. The most significant difference was between Filtek Z250 and Fuji IX (p
    Matched MeSH terms: Glass Ionomer Cements
  6. Tengku Yasmin Tengku Azam, Quah, Xin Ying, Ismail Ab Rahman, Sam’an Malik Masudi, Norhayati Luddin, Rashita Abd Rashid
    MyJurnal
    Glass ionomer cement (GIC) has theunique fluoride release property and able to formionic bond with tooth structure. However, the brittleness of the material results in low hardness. In the present study, a new approach in utilization of local waste materials as fillers for improvement of hardness of GIC is reported.The synthesized wollastonite and mine-silica by-product were individually incorporated into commercial GIC and the Vickers hardness were evaluated. The results shown that the incorporation of 1 % wollastonite into GIC gave ~ 6% increment in hardness compared to the control GIC (66.53H ±7.37 versus 62.66HV±2.98)but not for themine-silica. Thus, wollastonite could be a potential material to be utilized as fillersin dental restorative composite
    Matched MeSH terms: Glass Ionomer Cements
  7. Saini, D., Nadig, G., Saini, R.
    MyJurnal
    The main objective of a root end filling material is to provide an apical seal that prevents the movement of bacteria and the diffusion of bacterial products from the root canal system into periapical tissues. The aim of this study was to compare the microleakage of three root end filling materials Mineral trioxide aggregate (MTA), Glass ionomer cement (GIC) and Silver GIC (Miracle Mix) using dye penetration technique under stereomicroscope. Forty-five extracted human maxillary central incisors were instrumented and obturated with gutta percha using lateral compaction technique. Following this, the teeth were stored in saline. After one week, teeth were apically resected at an angle of 90ï° to the long axis of the root and root end cavities were prepared. The teeth were divided into three groups of fifteen specimens each and were filled with Group I -MTA, Group II - GIC and Group III - Miracle Mix. The samples were coated with varnish and after drying, they were immersed in 1% methylene blue dye for 72 hours. The teeth were then rinsed, sectioned longitudinally and observed under stereomicroscope. The depth of dye penetration was measured in millimeters. Microleakage was found to be significantly less in MTA (0.83 mm) when compared to GIC (1.32 mm) (p < 0.001) and with Miracle Mix (1.39 mm) (p < 0.001) No significant difference was found when microleakage in Miracle Mix was compared to that of GIC (p = 0.752). Thus we concluded that MTA is a better material as root end filling material to prevent microleakage, in comparison to GIC and Miracle Mix.
    Matched MeSH terms: Glass Ionomer Cements
  8. Lutfi AN, Kannan TP, Fazliah MN, Jamaruddin MA, Saidi J
    Aust Dent J, 2010 Mar;55(1):79-85.
    PMID: 20415916 DOI: 10.1111/j.1834-7819.2009.01185.x
    The biological examination of pulp injury, repair events and response of dental pulp stem cells to dental restorative materials is important to accomplish restorative treatment, especially to commonly used dental materials in paediatric dentistry, such as glass ionomer cement (GIC) and calcium hydroxide (Ca(OH)(2)) lining cement.
    Matched MeSH terms: Glass Ionomer Cements*
  9. Ab-Ghani Z, Ngo H, McIntyre J
    Aust Dent J, 2007 Dec;52(4):276-81.
    PMID: 18265682
    BACKGROUND: There have been cononcerns about the dissolution of conventional glass ionomer cement (GIC) and its possible degradation when exposed to an acidic environment over time. The objective of this study was to investigate the effects of exposure of Fuji IX Fast to the simulated acidic aspects of the oral environment in terms of any change in the elemental composition of strontium (Sr), phosphorus (P), calcium (Ca) and fluorine (F) which resulted at the surface of this material.

    METHODS: Sixty-five cylindrical block of Fuji IX Fast were prepared using split moulds. The demineralizing solution was an acetate buffered demineralizing solution at pH 403. The remineralizing solution was a buffered solution containing 1.5 mM Ca, 0.9 mM P and 10 ppm F at pH 7. The blocks of Fuji IX Fast were subjected either to two-day alternating cycles of remineralization and demineralization for up to 24 days (test); 6 two-day cycles of demineralizing or remineralizing solution separately, or deionized distilled water alone (controls) or were left untreated (base line control). Mineral profiles of Ca, P, Sr and F within 100 microm of the material surface were assessed following 8, 16 and 24 days of treatment (test); 4, 8 or 12 days (controls) or for baseline control samples, using electron probe microanalysis (EPMA).

    RESULTS: There were significant changes in mineral profile in the test specimens in terms of Sr and Ca concentrations. A molecule for molecule exchange of these elements resulted between GIC and eluant solutions. Fluoride loss from the GIC occurredto the level comparable with uptake levels recorded in eluant solutions from previous studies. The ionic exchanges appeared to be the result of dissolution followed by an equilibrium-driven diffusion. These exchanges were superficial though substantial.

    CONCLUSIONS: Simulated exposure of Fuji IX to the oral environment resulted in an exchange of Ca from the bathing solutions into Fuji IX to replace any Sr which was lost to the GIC. Fluorine loss from the GIC followed previously described patterns. The possible clinical significance of this exchange was discussed.

    Matched MeSH terms: Glass Ionomer Cements/chemistry*
  10. Wan Bakar W, McIntyre J
    Aust Dent J, 2008 Sep;53(3):226-34.
    PMID: 18782366 DOI: 10.1111/j.1834-7819.2008.00053.x
    Erosive substances such as gastric acids, lemon juice and even the less erosive cola drinks have been extensively investigated for their destructive effects on enamel. However, their effects on the tooth-coloured restoratives has not been widely analysed. The objective of this study was to assess their effects on the more commonly used glass containing restorative materials in vitro.
    Matched MeSH terms: Glass Ionomer Cements*
  11. Ariffin Z, Ngo H, McIntyre J
    Aust Dent J, 2006 Dec;51(4):328-32.
    PMID: 17256308
    BACKGROUND: This study investigated the extent to which a coating of 10% silver fluoride (AgF) on discs of glass jonomer cements (GIGs) would enhance the release of fluoride ion into eluting solutions at varying pH.

    MATERIALS AND METHODS: Forty discs each of Fuji LX, Fuji VII and of Vitrebond were prepared in a plastic mould. Twenty discs of each material were coated for 30 seconds with a 10% solution of AgF. Five discs each of coated and uncoated material were placed individually in 4m1 of differing eluant solutions. The eluant solutions comprised deionized distilled water (DDW) and three separate acetate buffered solutions at pH 7, pH 5 and pH 3. After 30 minutes the discs were removed and placed in five vials containing 4m1 of the various solutions for a further 30 minutes. This was repeated for further intervals of time up to 216 hours, and all eluant solutions were stored. Fluoride concentrations in the eluant solutions were estimated using a fluoride specific electrode, with TISAB IV as a metal ion complexing and ionic concentration adjustment agent. Cumulative fluoride release patterns were determined from the incremental data.

    RESULTS: The coating of AgF greatly enhanced the level of fluoride ion release from all materials tested. Of the uncoated samples, Vitrehond released the greater concentrations of fluoride ion, followed by Fuji VII. However, cumulative levels of fluoride released from coated samples of the GICs almost matched those from coated Vitrebond.

    CONCLUSIONS: It was concluded that a coating of 10% AgF on GICs and a resin modified GIC greatly enhanced the concentration of fluoride released from these materials. This finding might be applied to improving protection against recurrent caries, particularly in high caries risk patients, and in the atraumatic restorative technique (ART) of restoration placement.

    Matched MeSH terms: Glass Ionomer Cements/chemistry*
  12. Farea M, Masudi S, Wan Bakar WZ
    Aust Endod J, 2010 Aug;36(2):48-53.
    PMID: 20666748 DOI: 10.1111/j.1747-4477.2009.00187.x
    The aim of this study was to evaluate in vitro the apical sealing ability of cold lateral and system B root filling techniques using dye penetration. Eighty-six extracted single-rooted human teeth were prepared and randomly divided into two experimental groups to be obturated by cold lateral condensation (n = 33) and system B (n = 33). The remaining 20 teeth served as positive and negative controls. The roots were embedded for 72 h in methylene blue dye solution and sectioned transversely for dye penetration evaluation using stereomicroscope. The results of this study showed that cold lateral condensation leaked significantly more (P < 0.001) than system B technique.
    Matched MeSH terms: Glass Ionomer Cements/chemistry
  13. Bapat RA, Parolia A, Chaubal T, Dharamadhikari S, Abdulla AM, Sakkir N, et al.
    Biomater Sci, 2021 May 04;9(9):3244-3283.
    PMID: 33949464 DOI: 10.1039/d1bm00233c
    Dental treatment is provided for a wide variety of oral health problems like dental caries, periodontal diseases, periapical infections, replacement of missing teeth and orthodontic problems. Various biomaterials, like composite resins, amalgam, glass ionomer cement, acrylic resins, metal alloys, impression materials, bone grafts, membranes, local anaesthetics, etc., are used for dental applications. The physical and chemical characteristics of these materials influence the outcome of dental treatment. It also impacts on the biological, allergic and toxic potential of biomaterials. With innovations in science and their positive results, there is also a need for awareness about the biological risks of these biomaterials. The aim of dental treatment is to have effective, yet safe, and long-lasting results for the benefit of patients. For this, it is important to have a thorough understanding of biomaterials and their effects on local and systemic health. Materials used in dentistry undergo a series of analyses before their oral applications. To the best of our knowledge, this is the first and original review that discusses the reasons for and studies on the toxicity of commonly used biomaterials for applications in dentistry. It will help clinicians to formulate a methodical approach for the selection of dental biomaterials, thus providing an awareness for forecasting their risk of toxic reactions.
    Matched MeSH terms: Glass Ionomer Cements
  14. Zainuddin N, Karpukhina N, Law RV, Hill RG
    Dent Mater, 2012 Oct;28(10):1051-8.
    PMID: 22841162 DOI: 10.1016/j.dental.2012.06.011
    The purpose of this study was to characterize commercial glass polyalkenoate cement (GPC) or glass ionomer cement (GIC), Glass Carbomer(®), which is designed to promote remineralization to fluorapatite (FAp) in the mouth. The setting reaction of the cement was followed using magic angle spinning nuclear magnetic resonance (MAS-NMR) spectroscopy.
    Matched MeSH terms: Glass Ionomer Cements/chemistry*
  15. Prathibha B, Reddy PP, Anjum MS, Monica M, Praveen BH
    Dent Res J (Isfahan), 2019 2 13;16(1):36-41.
    PMID: 30745917
    Background: The aim of this study is comparing the retention and caries preventive effect of the glass-ionomer fissure sealant and resin-based fissure sealant.

    Materials and Methods: A randomized-controlled split-mouth study was conducted to compare the retention and the caries preventive effect of light-cured resin-based sealant (3M ESPE) and glass ionomer sealant (Fuji VII). The sealants were applied to either the right or the left lower mandibular molars (7-9 yrs of age) in 120 school children, based on the randomization process. They were recalled for assessment of clinical retention at intervals of 3, 6, and 12 months. The caries-preventive effect between the two materials was tested statistically by the McNemar's test for matched pairs, and the differences observed with regard to the retention of the materials was tested by Chi-square tests. The level of significance was set to be at P < 0.05.

    Results: At the end of 12th month, sealant retention is found to be higher in the resin-based sealant group compared to the glass ionomer group. In the glass ionomer sealants placed, 101 (91%) were caries-free and 10 (9%) had caries. In the resin-based sealant, 105 (94.60%) had sound teeth and 6 (5.4%) had dental caries (P = 0.34).

    Conclusion: The glass ionomer sealant was less retentive when compared to resin sealants. The caries incidence between the glass ionomer and resin-based sealants was not statistically significant.

    Matched MeSH terms: Glass Ionomer Cements
  16. Jhatial AA, Goh WI, Mastoi AK, Rahman AF, Kamaruddin S
    PMID: 33745050 DOI: 10.1007/s11356-021-13435-2
    The production of cement contributes to 10% of global carbon dioxide (CO2) pollution and 74 to 81% towards the total CO2 pollution by concrete. In addition to that, its low strength-to-weight ratio, high density and thermal conductivity are among the few limitations of heavy weight concrete. Therefore, this study was carried out to provide a solution to these limitations by developing innovative eco-friendly lightweight foamed concrete (LFC) of 1800 kg/m3 density incorporating 20-25% palm oil fuel ash (POFA) and 5-15% eggshell powder (ESP) by weight of total binder as supplementary cementitious material (SCM). The influence of combined utilization of POFA and ESP on the fresh state properties of eco-friendly LFC was determined using the J-ring test. To determine the mechanical properties, a total of 48 cubes and 24 cylinders were prepared for compressive strength, splitting tensile strength and modulus of elasticity each. A total of 24 panels were prepared to determine the thermal properties in terms of surface temperature and thermal conductivity. Furthermore, to assess the environmental impact and eco-friendliness of the developed LFC, the embodied carbon and eco-strength efficiency was calculated. It was determined that the utilization of POFA and ESP reduced the workability slightly but enhanced the mechanical properties of LFC (17.05 to 22.60 MPa compressive strength and 1.43 to 2.61 MPa tensile strength), thus satisfies the ACI213R requirements for structural lightweight concrete and that it can be used for structural applications. Additionally, the thermal conductivity reduced ranging from 0.55 to 0.63 W/mK compared to 0.82 W/mK achieved by control sample. Furthermore, the developed LFC showed a 16.96 to 33.55% reduction in embodied carbon and exhibited higher eco-strength efficiency between 47.82 and 76.97%. Overall, the combined utilization of POFA and ESP as SCMs not only enhanced the thermo-mechanical performance, makes the sustainable LFC as structural lightweight concrete, but also has reduced the environmental impacts caused by the disposal of POFA and ESP in landfills as well as reducing the total CO2 emissions during the production of eco-friendly LFC.
    Matched MeSH terms: Glass Ionomer Cements
  17. Rajeev V, Arunachalam R, Nayar S, Arunima PR, Ganapathy S, Vedam V
    Eur J Dent, 2017 4 25;11(1):58-63.
    PMID: 28435367 DOI: 10.4103/ejd.ejd_113_16
    OBJECTIVE: This in vitro study was designed to assess shear bond strength (SBS) of ormocer flowable (OF) resin as a luting agent, ormocer as an indirect veneer material with portrayal of modes of failures using scanning electron microscope (SEM).

    MATERIALS AND METHODS: Sixty maxillary central incisors were divided into Group I, II, and III with 20 samples each based on luting cement used. They were OF, self-adhesive (SA) cement, and total etch (TE) cement. These groups were subdivided into "a" and "b" of ten each based on the type of veneering materials used. Veneer discs were fabricated using Ormocer restorative (O) and pressable ceramic (C). Specimens were thermocycled and loaded under universal testing machine for SBS. The statistical analysis was done using one-way ANOVA post hoc Tukey honest significant difference method.

    RESULTS: A significant difference was observed between the Groups I and II (P < 0.05). The highest mean bond strength when using ormocer veneer was obtained with the Group Ia (19.11 ± 1.92 Mpa) and lowest by Group IIa (8.1 ± 1.04 Mpa), whereas the highest mean bond strength while using ceramic veneer was of similar range for Group Ib (18.04 ± 4.08 Mpa) and Group IIIb (18.07 ± 1.40 Mpa). SEM analysis revealed OF and TE presented mixed type of failure when compared with SA where failure mode was totally adhesive.

    CONCLUSION: OF was found equally efficient like TE. Bond strength of ormocer as a veneer was not inferior to ceramic making it one of the promising additions in the field of dentistry.

    Matched MeSH terms: Glass Ionomer Cements
  18. Moheet IA, Luddin N, Rahman IA, Kannan TP, Nik Abd Ghani NR, Masudi SM
    Eur J Dent, 2019 Jul;13(3):470-477.
    PMID: 31280484 DOI: 10.1055/s-0039-1693524
    The aim of this article is to provide a brief insight regarding the recent studies and their recommendations related to the modifications to glass ionomer cement (GIC) powder in order to improve their properties. An electronic search of publications was made from the year 2000 to 2018. The databases included in the current study were EBSCOhost, PubMed, and ScienceDirect. The inclusion criteria for the current study include publication with abstract or full-text articles, original research, reviews or systematic reviews, in vitro, and in vivo studies that were written in English language. Among these only articles published in peer-reviewed journals were included. Articles published in other languages, with no available abstract and related to other nondentistry fields, were excluded. A detailed review of the recent materials used as a filler phase in GIC powder has revealed that not all modifications produce beneficial results. Recent work has demonstrated that modification of GIC powder with nano-particles has many beneficial effects on the properties of the material. This is due to the increase in surface area and surface energy, along with better particle distribution of the nano-particle. Therefore, more focus should be given on nano-particle having greater chemical affinity for GIC matrix as well as the tooth structure that will enhance the physicochemical properties of GIC.
    Matched MeSH terms: Glass Ionomer Cements
  19. Rahman SHBA, Irawan S, Shafiq N, Rajeswary R
    Heliyon, 2020 Feb;6(2):e03478.
    PMID: 32140594 DOI: 10.1016/j.heliyon.2020.e03478
    In selecting the binder composition for oil well application, its stability is an important design parameter. This paper presents the results of an experimental study conducted for comparing the linear expansion characteristics of geopolymer cement with the traditionally used ASTM Class G cement system. The expansion test was done in a water bath at 60 °C subjected to different curing intervals. The linear expansion of a cement system defines as the dimensional changes occur in the system, which is sometimes required to avoid the cement shrinkage during the hydration phase. In the case when the desired level of expansion is not achieved in the system, then the commercially available expandable materials are added in the class G cement system that enables the system to expand to the desired level. Shrinkage in the cementing system causes the formation of a microannulus or induces a gap that may allow the migration of fluid, hence the integrity of the system could be lost. This experimental study has revealed that the geopolymer cement tends to expand 0.15%-0.2% without the addition of any admixture, whereas the ASTM Class G cement has shown a lower value of linear expansion, which was obtained less than 0.1% after 18 days of curing. In the case of Class G cement, the addition of expandable material helped to increase the expansion; in the case of a geopolymer system, the additive has further accelerated the expansion.
    Matched MeSH terms: Glass Ionomer Cements
  20. Al-Kadhim, A.H.A., Abdullah H.
    MyJurnal
    Introduction: The purpose of this study was to decide on the relation between types of mixing and the porosity of diameter (1-100) µm and compressive strength of RMGIC. Methods: Fifteen specimens 6mm height and 4mm in diameter were prepared for each type of luting cement and were stored in distilled water at 37° C for 24 hours. The compressive strength was determined. The fractured surfaces of 10 randomly selected specimens of each cement type were analyzed using SEM at 250 times magnification, and five photomicrographs were taken at five random places. All the photomicrographs were analyzed using image analyzer software to determine the amount and size of porosity present. Results: There was no significant difference in compressive strength between different mixing methods, but it had a significant impact by increasing the percentage of porosity of diameter (1-100) µm in diameter of RMGIC. There was no linear relationship between compressive strength and porosity (1-100) µm in diameter for both types of luting cements (P>0.05). Conclusion: No significant differences in compressive strength were found using different mixing methods. The size and number of porosity in the specimens of encapsulated cements were greater than those of hand-mixed cements. The porosity (1-100) µm in diameter and the compressive strength bore no linear relationship to each other.
    Matched MeSH terms: Glass Ionomer Cements
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links