Displaying publications 1 - 20 of 170 in total

Abstract:
Sort:
  1. Baharuddin MY, Salleh ShH, Zulkifly AH, Lee MH, Noor AM, A Harris AR, et al.
    PMID: 24484753 DOI: 10.1186/1471-2474-15-30
    Minimal available information concerning hip morphology is the motivation for several researchers to study the difference between Asian and Western populations. Current use of a universal hip stem of variable size is not the best option for all femur types. This present study proposed a new design process of the cementless femoral stem using a three dimensional model which provided more information and accurate analysis compared to conventional methods.
    Matched MeSH terms: Imaging, Three-Dimensional*
  2. Wong SC, Nawawi O, Ramli N, Abd Kadir KA
    Acad Radiol, 2012 Jun;19(6):701-7.
    PMID: 22578227 DOI: 10.1016/j.acra.2012.02.012
    The aim of this study was to compare conventional two-dimensional (2D) digital subtraction angiography (DSA) with three-dimensional (3D) rotational DSA in the investigation of intracranial aneurysm in terms of detection, size measurement, neck diameter, neck delineation, and relationship with surrounding vessels. A further aim was to compare radiation dose, contrast volume, and procedural time between the two protocols.
    Matched MeSH terms: Imaging, Three-Dimensional/methods*
  3. Wan Hassan WN, Othman SA, Chan CS, Ahmad R, Ali SN, Abd Rohim A
    Am J Orthod Dentofacial Orthop, 2016 Nov;150(5):886-895.
    PMID: 27871715 DOI: 10.1016/j.ajodo.2016.04.021
    INTRODUCTION: In this study we aimed to compare measurements on plaster models using a digital caliper, and on 3-dimensional (3D) digital models, produced using a structured-light scanner, using 3D software.

    METHODS: Fifty digital models were scanned from the same plaster models. Arch and tooth size measurements were made by 2 operators, twice. Calibration was done on 10 sets of models and checked using the Pearson correlation coefficient. Data were analyzed by error variances, repeatability coefficient, repeated-measures analysis of variance, and Bland-Altman plots.

    RESULTS: Error variances ranged between 0.001 and 0.044 mm for the digital caliper method, and between 0.002 and 0.054 mm for the 3D software method. Repeated-measures analysis of variance showed small but statistically significant differences (P <0.05) between the repeated measurements in the arch and buccolingual planes (0.011 and 0.008 mm, respectively). There were no statistically significant differences between methods and between operators. Bland-Altman plots showed that the mean biases were close to zero, and the 95% limits of agreement were within ±0.50 mm. Repeatability coefficients for all measurements were similar.

    CONCLUSIONS: Measurements made on models scanned by the 3D structured-light scanner were in good agreement with those made on conventional plaster models and were, therefore, clinically acceptable.

    Matched MeSH terms: Imaging, Three-Dimensional
  4. Johari NH, Osman K, Helmi NH, Abdul Kadir MA
    PMID: 23521065 DOI: 10.1080/10255842.2013.776548
    Efforts to model the human upper respiratory system have undergone many phases. Geometrical proximity to the realistic shape has been the subject of many research projects. In this study, three different geometries of the trachea and main bronchus were modelled, which were reconstructed from computed tomography (CT) scan images. The geometrical variations were named realistic, simplified and oversimplified. Realistic refers to the lifelike image taken from digital imaging and communications in medicine format CT scan images, simplified refers to the reconstructed image based on natural images without realistic details pertaining to the rough surfaces, and oversimplified describes the straight wall geometry of the airway. The characteristics of steady state flows with different flow rates were investigated, simulating three varied physical activities and passing through each model. The results agree with previous studies where simplified models are sufficient for providing comparable results for airflow in human airways. This work further suggests that, under most exercise conditions, the idealised oversimplified model is not favourable for simulating either airflow regimes or airflow with particle depositions. However, in terms of immediate analysis for the prediction of abnormalities of various dimensions of human airways, the oversimplified techniques may be used.
    Matched MeSH terms: Imaging, Three-Dimensional
  5. Abd Fattah SYAS, Hariri F, Nambiar P, Abu Bakar Z, Abdul Rahman ZA
    Curr Med Imaging Rev, 2019;15(7):645-653.
    PMID: 32008512 DOI: 10.2174/1573405614666181012144745
    OBJECTIVE: To validate the accuracy of the mandibular canal region in 3D biomodel produced by using data obtained from Cone-Beam Computed Tomography (CBCT) of cadaveric mandibles.

    METHODS: Six hemi-mandible samples were scanned using the i-CAT CBCT system. The scanned data was transferred to the OsiriX software for measurement protocol and subsequently into Mimics software to fabricate customized cutting jigs and 3D biomodels based on rapid prototyping technology. The hemi-mandibles were segmented into 5 dentoalveolar blocks using the customized jigs. Digital calliper was used to measure six distances surrounding the mandibular canal on each section. The same distances were measured on the corresponding cross-sectional OsiriX images and the 3D biomodels of each dentoalveolar block.

    RESULTS: Statistically no significant difference was found when measurements from OsiriX images and 3D biomodels were compared to the "gold standard" -direct digital calliper measurement of the cadaveric dentoalveolar blocks. Moreover, the mean value difference of the various measurements between the different study components was also minimal.

    CONCLUSION: Various distances surrounding the mandibular canal from 3D biomodels produced from the CBCT scanned data was similar to that of direct digital calliper measurements of the cadaveric specimens.

    Matched MeSH terms: Imaging, Three-Dimensional
  6. Purmal K, Alam MK, Pohchi A, Abdul Razak NH
    PLoS One, 2013;8(12):e84202.
    PMID: 24367643 DOI: 10.1371/journal.pone.0084202
    Intermaxillary (IMF) screws feature several advantages over other devices used for intermaxillary fixation, but using cone beam computed tomography (CBCT) scans to determine the safe and danger zones to place these devices for all patients can be expensive. This study aimed to determine the optimal interradicular and buccopalatal/buccolingual spaces for IMF screw placement in the maxilla and mandible. The CBCT volumetric data of 193 patients was used to generate transaxial slices between the second molar on the right to the second molar on the left in both arches. The mean interradicular and buccopalatal/buccolingual distances and standard deviation values were obtained at heights of 2, 5, 8 and 11 mm from the alveolar bone crest. An IMF screw with a diameter of 1.0 mm and length of 7 mm can be placed distal to the canines (2 - 11 mm from the alveolar crest) and less than 8 mm between the molars in the maxilla. In the mandible, the safest position is distal to the first premolar (more than 5 mm) and distal to the second premolar (more than 2 mm). There was a significant difference (p<0.05) between the right and left quadrants. The colour coding 3D template showed the safe and danger zones based on the mesiodistal, buccopalatal and buccolingual distances in the maxilla and mandible.The safest sites for IMF screw insertion in the maxilla were between the canines and first premolars and between the first and second molars. In the mandible, the safest sites were between the first and second premolars and between the second premolar and first molar. However, the IMF screw should not exceed 1.0 mm in diameter and 7 mm in length.
    Matched MeSH terms: Imaging, Three-Dimensional*
  7. Adeshina AM, Hashim R, Khalid NE, Abidin SZ
    Interdiscip Sci, 2013 Mar;5(1):23-36.
    PMID: 23605637 DOI: 10.1007/s12539-013-0155-z
    In the medical diagnosis and treatment planning, radiologists and surgeons rely heavily on the slices produced by medical imaging devices. Unfortunately, these image scanners could only present the 3-D human anatomical structure in 2-D. Traditionally, this requires medical professional concerned to study and analyze the 2-D images based on their expert experience. This is tedious, time consuming and prone to error; expecially when certain features are occluding the desired region of interest. Reconstruction procedures was earlier proposed to handle such situation. However, 3-D reconstruction system requires high performance computation and longer processing time. Integrating efficient reconstruction system into clinical procedures involves high resulting cost. Previously, brain's blood vessels reconstruction with MRA was achieved using SurLens Visualization System. However, adapting such system to other image modalities, applicable to the entire human anatomical structures, would be a meaningful contribution towards achieving a resourceful system for medical diagnosis and disease therapy. This paper attempts to adapt SurLens to possible visualisation of abnormalities in human anatomical structures using CT and MR images. The study was evaluated with brain MR images from the department of Surgery, University of North Carolina, United States and CT abdominal pelvic, from the Swedish National Infrastructure for Computing. The MR images contain around 109 datasets each of T1-FLASH, T2-Weighted, DTI and T1-MPRAGE. Significantly, visualization of human anatomical structure was achieved without prior segmentation. SurLens was adapted to visualize and display abnormalities, such as an indication of walderstrom's macroglobulinemia, stroke and penetrating brain injury in the human brain using Magentic Resonance (MR) images. Moreover, possible abnormalities in abdominal pelvic was also visualized using Computed Tomography (CT) slices. The study shows SurLens' functionality as a 3-D Multimodal Visualization System.
    Matched MeSH terms: Imaging, Three-Dimensional/instrumentation; Imaging, Three-Dimensional/methods*
  8. Adeshina AM, Hashim R, Khalid NE, Abidin SZ
    Interdiscip Sci, 2012 Sep;4(3):161-72.
    PMID: 23292689 DOI: 10.1007/s12539-012-0132-y
    CT and MRI scans are widely used in medical diagnosis procedures, but they only produce 2-D images. However, the human anatomical structure, the abnormalities, tumors, tissues and organs are in 3-D. 2-D images from these devices are difficult to interpret because they only show cross-sectional views of the human structure. Consequently, such circumstances require doctors to use their expert experiences in the interpretation of the possible location, size or shape of the abnormalities, even for large datasets of enormous amount of slices. Previously, the concept of reconstructing 2-D images to 3-D was introduced. However, such reconstruction model requires high performance computation, may either be time-consuming or costly. Furthermore, detecting the internal features of human anatomical structure, such as the imaging of the blood vessels, is still an open topic in the computer-aided diagnosis of disorders and pathologies. This paper proposes a volume visualization framework using Compute Unified Device Architecture (CUDA), augmenting the widely proven ray casting technique in terms of superior qualities of images but with slow speed. Considering the rapid development of technology in the medical community, our framework is implemented on Microsoft.NET environment for easy interoperability with other emerging revolutionary tools. The framework was evaluated with brain datasets from the department of Surgery, University of North Carolina, United States, containing around 109 MRA datasets. Uniquely, at a reasonably cheaper cost, our framework achieves immediate reconstruction and obvious mappings of the internal features of human brain, reliable enough for instantaneous locations of possible blockages in the brain blood vessels.
    Matched MeSH terms: Imaging, Three-Dimensional/methods*
  9. Saidin S, Abdul Kadir MR, Sulaiman E, Abu Kasim NH
    J Dent, 2012 Jun;40(6):467-74.
    PMID: 22366313 DOI: 10.1016/j.jdent.2012.02.009
    The aim of this study was to analyse micromotion and stress distribution at the connections of implants and four types of abutments: internal hexagonal, internal octagonal, internal conical and trilobe.
    Matched MeSH terms: Imaging, Three-Dimensional/methods
  10. Ishak MI, Abdul Kadir MR, Sulaiman E, Abu Kasim NH
    Int J Oral Maxillofac Surg, 2012 Sep;41(9):1077-89.
    PMID: 22575179 DOI: 10.1016/j.ijom.2012.04.010
    The aim of this study was to compare two different types of surgical approaches, intrasinus and extramaxillary, for the placement of zygomatic implants to treat atrophic maxillae. A computational finite element simulation was used to analyze the strength of implant anchorage for both approaches in various occlusal loading locations. Three-dimensional models of the craniofacial structures surrounding a region of interest, soft tissue and framework were developed using computed tomography image datasets. The implants were modelled using computer-aided design software. The bone was assumed to be linear isotropic with a stiffness of 13.4 GPa, and the implants were assumed to be made of titanium with a stiffness of 110 GPa. Masseter forces of 300 N were applied at the zygomatic arch, and occlusal loads of 150 N were applied vertically onto the framework surface at different locations. The intrasinus approach demonstrated more satisfactory results and could be a viable treatment option. The extramaxillary approach could also be recommended as a reasonable treatment option, provided some improvements are made to address the cantilever effects seen with that approach.
    Matched MeSH terms: Imaging, Three-Dimensional
  11. Ahmad Fadzil M, Ngah NF, George TM, Izhar LI, Nugroho H, Adi Nugroho H
    PMID: 21097305 DOI: 10.1109/IEMBS.2010.5628041
    Diabetic retinopathy (DR) is a sight threatening complication due to diabetes mellitus that affects the retina. At present, the classification of DR is based on the International Clinical Diabetic Retinopathy Disease Severity. In this paper, FAZ enlargement with DR progression is investigated to enable a new and an effective grading protocol DR severity in an observational clinical study. The performance of a computerised DR monitoring and grading system that digitally analyses colour fundus image to measure the enlargement of FAZ and grade DR is evaluated. The range of FAZ area is optimised to accurately determine DR severity stage and progression stages using a Gaussian Bayes classifier. The system achieves high accuracies of above 96%, sensitivities higher than 88% and specificities higher than 96%, in grading of DR severity. In particular, high sensitivity (100%), specificity (>98%) and accuracy (99%) values are obtained for No DR (normal) and Severe NPDR/PDR stages. The system performance indicates that the DR system is suitable for early detection of DR and for effective treatment of severe cases.
    Matched MeSH terms: Imaging, Three-Dimensional/methods*
  12. Zubair M, Abdullah MZ, Ahmad KA
    Comput Math Methods Med, 2013;2013:727362.
    PMID: 23983811 DOI: 10.1155/2013/727362
    The accuracy of the numerical result is closely related to mesh density as well as its distribution. Mesh plays a very significant role in the outcome of numerical simulation. Many nasal airflow studies have employed unstructured mesh and more recently hybrid mesh scheme has been utilized considering the complexity of anatomical architecture. The objective of this study is to compare the results of hybrid mesh with unstructured mesh and study its effect on the flow parameters inside the nasal cavity. A three-dimensional nasal cavity model is reconstructed based on computed tomographic images of a healthy Malaysian adult nose. Navier-Stokes equation for steady airflow is solved numerically to examine inspiratory nasal flow. The pressure drop obtained using the unstructured computational grid is about 22.6 Pa for a flow rate of 20 L/min, whereas the hybrid mesh resulted in 17.8 Pa for the same flow rate. The maximum velocity obtained at the nasal valve using unstructured grid is 4.18 m/s and that with hybrid mesh is around 4.76 m/s. Hybrid mesh reported lower grid convergence index (GCI) than the unstructured mesh. Significant differences between unstructured mesh and hybrid mesh are determined highlighting the usefulness of hybrid mesh for nasal airflow studies.
    Matched MeSH terms: Imaging, Three-Dimensional/statistics & numerical data*
  13. Basri AA, Zuber M, Basri EI, Zakaria MS, Aziz AFA, Tamagawa M, et al.
    Comput Math Methods Med, 2020;2020:9163085.
    PMID: 32454886 DOI: 10.1155/2020/9163085
    This study investigated the impact of paravalvular leakage (PVL) in relation to the different valve openings of the transcatheter aortic valve implantation (TAVI) valve using the fluid structure interaction (FSI) approach. Limited studies were found on the subject of FSI with regards to TAVI-PVL condition, which involves both fluid and structural responses in coupling interaction. Hence, further FSI simulation with the two-way coupling method is implemented to investigate the effects of hemodynamics blood flow along the patient-specific aorta model subjected to the interrelationship between PVL and the different valve openings using the established FSI software ANSYS 16.1. A 3D patient-specific aorta model is constructed using MIMICS software. The TAVI valve identical to Edward SAPIEN XT 26 (Edwards Lifesciences, Irvine, California), at different Geometrical Orifice Areas (GOAs), is implanted into the patient's aortic annulus. The leaflet opening of the TAVI valve is drawn according to severity of GOA opening represented in terms of 100%, 80%, 60%, and 40% opening, respectively. The result proved that the smallest percentage of GOA opening produced the highest possibility of PVL, increased the recirculatory flow proximally to the inner wall of the ascending aorta, and produced lower backflow velocity streamlines through the side area of PVL region. Overall, 40% GOA produced 89.17% increment of maximum velocity magnitude, 19.97% of pressure drop, 65.70% of maximum WSS magnitude, and a decrement of 33.62% total displacement magnitude with respect to the 100% GOA.
    Matched MeSH terms: Imaging, Three-Dimensional
  14. Shivdas S, Hashim MS, Ahmad TS
    J Orthop Surg (Hong Kong), 2018 10 4;26(3):2309499018802504.
    PMID: 30278809 DOI: 10.1177/2309499018802504
    PURPOSE: Our primary objectives were to create a reliable, noninvasive method for three-dimensional morphometry of deep bony parameters within the sigmoid notch of the distal radius, to identify its morphological patterns, and to identify any significant variation between the left and the right wrists. Our secondary objectives were to obtain morphometric values that could represent our population and to identify any possible ethnic variations.

    METHODS: Computed tomography scans of 102 wrists from 51 healthy individuals were analyzed using a virtualization software. Four anatomical parameters at the distal radius sigmoid notch, namely, the radius of curvature, depth, version angle, and sagittal slope were measured. Morphological patterns of the sigmoid notch surface were identified. The results were statistically analyzed to assess the reliability of the technique and were compared with previously published literature.

    RESULTS: Comparing our findings with previously published values, our study revealed a slightly larger radius of curvature and sagittal slope, while revealing a smaller depth and version. We identified the S-type, C-type, and ski-slope morphological variants. The flat-face morphological variant, however, was not identified. The sigmoid notch at the left and right wrists were similar, except for the radius of curvature.

    CONCLUSION: This study demonstrates a noninvasive, fast, reliable, and reproducible technique for analyzing the sigmoid notch of the distal radius. In wrist injuries with intact distal radius sigmoid notch but involving comminuted fractures of the ulnar head, ulnar head replacement may be indicated. In such cases, analysis of the ipsilateral intact sigmoid notch would allow us to prepare an ulnar head prosthesis of appropriate size.

    Matched MeSH terms: Imaging, Three-Dimensional*
  15. Othman SA, Aidil Koay NA
    Sci Rep, 2016 08 10;6:31335.
    PMID: 27507713 DOI: 10.1038/srep31335
    We analyzed the facial features of Chinese children with repaired unilateral cleft lip and palate (UCLP) and compared them with a normal control group using a three-dimensional (3D) stereophotogrammetry camera. This cross-sectional study examined 3D measurements of the facial surfaces of 20 Chinese children with repaired UCLP and 40 unaffected Chinese children aged 7 to 12 years old, which were captured using the VECTRA 3D five-pod photosystem and analyzed using Mirror software. Twenty-five variables and two ratios were compared between both groups using independent t-test. Intra- and inter-observer reliability was determined using ten randomly selected images and analyzed using intra-class correlation coefficient test (ICC). The level of significance was set at p 
    Matched MeSH terms: Imaging, Three-Dimensional
  16. Lo TS, Tan YL, Wu PY, Cortes EF, Pue LB, Al-Kharabsheh A
    PMID: 25265496 DOI: 10.1016/j.ejogrb.2014.09.015
    To evaluate the ultrasound morphology and its clinical outcome among women who had undergone Miniarc™ vs Monarc™ in the treatment of stress urinary incontinence (SUI).
    Matched MeSH terms: Imaging, Three-Dimensional
  17. Al-Khatib, Ali Rajih
    MyJurnal
    The surface facial imagings have many applications in medical fields. The recent past has seen great advances in three dimensional imaging which include laser scanning or stereophotogrammetry. Here, we reviewed various systems with reference to image acquisition, advantages and disadvantages. Examples of important clinical application with reference to the human face are also discussed. Finally, a 3D imaging system at Universiti Sains Malaysia (USM) is described.
    Matched MeSH terms: Imaging, Three-Dimensional
  18. Yew CC, Rahman SA, Alam MK
    BMC Pediatr, 2015;15:169.
    PMID: 26546159 DOI: 10.1186/s12887-015-0495-4
    The Temporomandibular Joint (TMJ) ankylosis in child is rare and yet the causes still remain unclear. This condition that affects the feeding and possible airway obstruction do not only worry the parents, but also possesses as a great challenge to the surgeons. Furthermore, it interferes with the facial skeletal and dento-alveolar development in the on growing child.
    Matched MeSH terms: Imaging, Three-Dimensional
  19. Ahmed N, Halim MSB, Ghani ZA, Khan ZA, Abbasi MS, Jamayet NB, et al.
    Biomed Res Int, 2021;2021:6674400.
    PMID: 33969123 DOI: 10.1155/2021/6674400
    The objective of this paper was to evaluate the existence of golden percentage in natural maxillary anterior teeth with the aid of 3D digital dental models and 2D photographs. And to propose regional values of golden percentage for restoration of maxillary anterior teeth. For this purpose, one hundred and ninety dentate subjects with sound maxillary anterior teeth were selected. Standardized frontal images were captured with DSLR, and the apparent width of maxillary anterior teeth was measured utilizing a software on a personal laptop computer. Once the dimensions were recorded, the calculations were made according to the golden percentage theory (GPT). The data were analyzed by independent and paired T-test. The level of significance was set at p < 0.05. The golden percentage values were not found in this study. The values obtained were 16%, 15%, 20%, 20%, 15%, and 16% moving from the right canine to the left canine teeth. There was no significant gender difference in the golden percentage values. Thus, golden percentage should not be used solely for the correction of anterior teeth or for determining dental attractiveness. Emphasis should be given to a range of dental proportion on regional basis.
    Matched MeSH terms: Imaging, Three-Dimensional*
  20. Farook TH, Jamayet NB, Abdullah JY, Asif JA, Rajion ZA, Alam MK
    Comput Biol Med, 2020 03;118:103646.
    PMID: 32174323 DOI: 10.1016/j.compbiomed.2020.103646
    OBJECTIVE: To design and compare the outcome of commercial (CS) and open source (OS) software-based 3D prosthetic templates for rehabilitation of maxillofacial defects using a low powered personal computer setup.

    METHOD: Medical image data for five types of defects were selected, segmented, converted and decimated to 3D polygon models on a personal computer. The models were transferred to a computer aided design (CAD) software which aided in designing the prosthesis according to the virtual models. Two templates were designed for each defect, one by an OS (free) system and one by CS. The parameters for analyses were the virtual volume, Dice similarity coefficient (DSC) and Hausdorff's distance (HD) and were executed by the OS point cloud comparison tool.

    RESULT: There was no significant difference (p > 0.05) between CS and OS when comparing the volume of the template outputs. While HD was within 0.05-4.33 mm, evaluation of the percentage similarity and spatial overlap following the DSC showed an average similarity of 67.7% between the two groups. The highest similarity was with orbito-facial prostheses (88.5%) and the lowest with facial plate prosthetics (28.7%).

    CONCLUSION: Although CS and OS pipelines are capable of producing templates which are aesthetically and volumetrically similar, there are slight comparative discrepancies in the landmark position and spatial overlap. This is dependent on the software, associated commands and experienced decision-making. CAD-based templates can be planned on current personal computers following appropriate decimation.

    Matched MeSH terms: Imaging, Three-Dimensional
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)