METHODS: This prospective clinical study included consecutive Asian patients with dark irides and confirmed for glaucoma. Only one eye of each patient was treated. Diode laser contact transscleral cyclophotocoagulation treatment was performed with the center of the probe placed 1.5 mm behind the limbus. About 30 pulses of 810-mm laser radiation (power, 1.8 to 2.0 W; duration, 0.3 to 0.5 second) were applied around the eye. Patients were examined at fixed postoperative intervals. Intraocular pressure levels and postoperative complications were recorded. The relation between patient and disease characteristics, total laser energy delivered, and intraocular pressure effects were analyzed.
RESULTS: Thirty-three patients were studied, with a mean follow-up period of 9.4 months. An average 56% of patients showed a 30% or greater drop in intraocular pressure. About 38% of patients achieved sustained intraocular pressure lowering to below 22 mm Hg at 18 months. Complications were few and included transient hypotony and iritis.
CONCLUSIONS: In Asian patients with refractory glaucoma or painful glaucomatous eyes with poor visual acuity (defined for this study as worse than 20/200), low-energy-setting diode laser contact transscleral cyclophotocoagulation by means of the glass ball probe is relatively effective and safe.
DESIGN: A combined cross-sectional and prospective study on PAC and PACG.
METHODS: A total of 35 eyes were included in the study for each group of normal control, PAC, and PACG patients from eye clinics in Kota Bharu, state of Kelantan, Malaysia, from January 2007 to November 2009. The PAC and PACG patients were divided into thin and thick CCT groups. They were followed up for 12 to 18 months for visual field progression assessment with their mean Advanced Glaucoma Intervention Study (AGIS) score.
RESULTS: The CCT was 516.8 ± 26.0 µm for PAC and 509.7 ± 27.4 µm for PACG. Both were significantly thinner compared with the control group with CCT of 540 ± 27.8 µm (P < 0.001). There was a statistically significant increase in the mean AGIS score after 12.9 ± 1.7 months of follow-up in the thin CCT group for PACG (P = 0.002). However, no significant increase in the mean AGIS score was found for the thick CCT group in PACG and for both thin and thick CCT in PAC.
CONCLUSIONS: The PAC and PACG had statistically significant thinner CCT compared with the controls. Thin CCT was associated with visual field progression based on the mean AGIS score in PACG.
DESIGN: A cross-sectional, non-interventional study.
METHODS: The IOP measurements by handheld Icare rebound tonometer (Finland) were first performed by a primary care physician. Then the IOP was measured using Perkins Mk3 applanation tonometer (Haag-Streit, UK) by an ophthalmologist who was masked to previous readings from the Icare rebound tonometer. The mean IOP measured by each tonometer was compared. Pearson correlation coefficient was used to explore the correlation between the IOP measurements of the 2 instruments. The level of agreement between them was assessed using the Bland and Altman method.
RESULTS: A total of 420 left eyes were examined. The mean age of subjects was 38.6 ± 18.2 years. Approximately 67% of subjects were female. The mean IOP was 16.3 ± 4.0 mm Hg using Icare and 13.4 ± 2.3 mm Hg using PAT. Pearson correlation coefficient showed a moderate positive correlation between the 2 methods (r = +0.524, P < 0.001). Linear regression analysis revealed a slope of 0.28 with R² of 0.255. The mean difference between the 2 methods was 2.90 ± 3.5 mm Hg and the sample t-test revealed a statistically significant mean difference from 0 (P < 0.001). The 95% limits of agreement between the 2 methods were between -9.73 and 3.93 mm Hg.
CONCLUSIONS: The handheld Icare rebound tonometer is a reasonably acceptable screening tool in community practices. However, Icare overestimated IOP with a mean of 2.90 mm Hg higher than the PAT. Thus, using Goldmann applanation tonometer as a confirmatory measurement tool of IOP is suggested.
METHODS: This was a retrospective, non-interventional, cohort study using data from a Japanese medical claims database. Patients with glaucoma aged ≥20 years with a first drug claim for glaucoma treatment between 01 July 2005 and 30 October 2014 and with data for > 6 months before and after this first prescription were included. The primary endpoint was duration of drug persistence among glaucoma patients with and without the use of fixed combination drugs in the year following initiation of second-line combination treatment.
RESULTS: Of 1403 patients included in the analysis, 364 (25.94%) received fixed combination drugs and 1039 (74.06%) received unfixed combination drugs as second-line treatment. Baseline characteristics were generally comparable between the groups. A total of 39.01% of patients on fixed combination drugs, compared with 41.67% of patients on unfixed combination drugs, persisted on their glaucoma drugs 12 months post second-index date. Median persistence durations for the fixed combination drugs and unfixed combination drugs groups were 6 (95% confidence interval [CI]: 5-8) and 7 months (95% CI 6-9), respectively. Patients who received prostaglandin analogs (PGAs) were the most persistent with their treatment (n = 99, 12.84%). Patients diagnosed with primary open-angle glaucoma were less likely to experience treatment modification (hazard ratio [HR]: 0.800, 95% CI 0.649-0.986, P = 0.036), while those diagnosed with secondary glaucoma were more likely to experience treatment modification (HR: 1.678, 95% CI 1.231-2.288, P = 0.001) compared with glaucoma suspects.
CONCLUSIONS: In this retrospective claims database study, the persistence rate of second-line glaucoma combination treatment was low, with no difference in persistence between glaucoma patients receiving unfixed combination drugs compared with fixed combination drugs. Patients on PGA showed greater persistence rates compared with other treatments.
METHODS: RGCs were isolated and cultured, and monoclonal antibodies (anti-rat Thy-1, Brn3a and RBPMS) were examined by immunocytochemistry. An overexpression vector MALAT1-RNA activation (RNAa), gene knockout vector MALAT1-RNA interference (RNAi), and control vector MALAT1-negative control (NC) were constructed. A chronic high intraocular pressure (IOP) rat model of glaucoma was established by episcleral vein cauterization. The RGCs were divided into the RGC control, RGC pressure, RGC pressure + MALAT1-NC, RGC pressure + MALAT1-RNAi and RGC pressure + MALAT1-RNAa groups. Sixty Sprague-Dawley (SD) rats were randomly divided into the normal, high IOP, high IOP + MALAT1-NC, high IOP + MALAT1-RNAa and high IOP + MALAT1-RNAi groups. qRT-PCR and western blotting were used to detect the expression levels of LncRNA-MALAT1 and PI3K/Akt. Terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL) and flow cytometry were used to detect RGC apoptosis.
RESULTS: Immunocytochemistry revealed that the cultured RGCs reached 90% purity. Compared with the RGC pressure + MALAT1-NC group, the RGC pressure + MALAT1-RNAa group exhibited elevated expression levels of MALAT1, lower total protein levels of PI3K and Akt and decreased RGC apoptosis, while these expression levels were reversed in the RGC pressure + MALAT1-RNAi group. RGC numbers and PI3K/Akt expression levels in the high IOP model groups were lower than those in the normal group. In the high IOP + MALAT1-RNAa group, the mRNA and protein expression levels of PI3K/Akt were reduced but higher than those in the other three high IOP model groups. Additionally, RGC numbers in the high IOP + MALAT1-RNAa group were lower than those in the normal group but higher than those in the other three high IOP model groups.
CONCLUSION: Our study provides evidence that LncRNA-MALAT1 could inhibit RGC apoptosis in glaucoma through activation of the PI3K/Akt signaling pathway.
PATIENTS AND METHODS: A retrospective review study involving 20 eyes that underwent primary augmented trabeculectomy with mitomycin (MMC) and 10 eyes GDD implantation in 3 tertiary centres in Malaysia between 1 January 2013 and 31 December 2019. They were followed up for at least 12 months postsurgical intervention. Intraocular pressure (IOP), number of topical IOP lowering medication and complications were evaluated at 1, 3, 6 and 12 months post-intervention. Based on the IOP, the success was divided into complete and partial success, and failure. IOP and postsurgical complications were compared using the Repetitive Measure Analysis of Variance (RM ANOVA) and the Pearson chi-square test.
RESULTS: Both methods were effective in lowering the IOP. Eyes with primary augmented trabeculectomy have significant lower IOP compared to GDD implantation (p = 0.037). There was a higher incidence of postoperative hypotony (30%) in the trabeculectomy group. There was also a significant reduction of mean number of topical pressure-lowering drugs required postoperatively (p = 0.015). Complete success was achieved in 100% of eyes with trabeculectomy and 67% in GDD implantation (p = 0.047).
CONCLUSIONS: Primary augmented trabeculectomy and GDD implantation are good surgical options for the treatment of JOAG. Both methods provide IOP lowering at 1 year. However, trabeculectomy provides better pressure lowering, compared to GDD implantation in patients with JOAG.
METHODS: We measured psychophysical contrast thresholds in one eye of 16 control subjects and 19 patients aged 67.8 ± 5.65 and 71.9 ± 7.15, respectively, (mean ± SD). Patients ranged in disease severity from suspects to severe glaucoma. We used the 17-region FDT-perimeter C20-threshold program and a custom 9-region test (R9) with similar visual field coverage. The R9 stimuli scaled their spatial frequencies with eccentricity and were modulated at lower temporal frequencies than C20 and thus did not display a clear spatial frequency-doubling (FD) appearance. Based on the overlapping areas of the stimuli, we transformed the C20 results to 9 measures for direct comparison with R9. We also compared mfVEP-based and psychophysical contrast thresholds in 26 younger (26.6 ± 7.3 y, mean ± SD) and 20 older normal control subjects (66.5 ± 7.3 y) control subjects using the R9 stimuli.
RESULTS: The best intraclass correlations between R9/C20 thresholds were for the central and outer regions: 0.82 ± 0.05 (mean ± SD, p ≤ 0.0001). The areas under receiver operator characteristic plots for C20 and R9 were as high as 0.99 ± 0.012 (mean ± SE). Canonical correlation analysis (CCA) showed significant correlation (r = 0.638, p = 0.029) with 1 dimension of the C20 and R9 data, suggesting that the lower and higher temporal frequency tests probed the same neural mechanism(s). Low signal quality made the contrast-threshold mfVEPs non-viable. The resulting mfVEP thresholds were limited by noise to artificially high contrasts, which unlike the psychophysical versions, were not correlated with age.
CONCLUSION: The lower temporal frequency R9 stimuli had similar diagnostic power to the FDT-C20 stimuli. CCA indicated the both stimuli drove similar neural mechanisms, possibly suggesting no advantage of FD stimuli for mfVEPs. Given that the contrast-threshold mfVEPs were non-viable, we used the present and published results to make recommendations for future mfVEP tests.