Displaying publications 1 - 20 of 30 in total

Abstract:
Sort:
  1. Agarwal R, Agarwal P
    Expert Opin Ther Targets, 2014 May;18(5):527-39.
    PMID: 24579961 DOI: 10.1517/14728222.2014.888416
    The homeostatic role of adenosine in regulating intraocular pressure (IOP) is now widely recognized, and hence, the drugs targeting adenosine receptors have become the focus of investigation. In this review, we summarize the adenosine receptor signaling pathways, which could be potential therapeutic targets for the management of glaucoma.
    Matched MeSH terms: Intraocular Pressure/physiology
  2. Chua J, Tham YC, Liao J, Zheng Y, Aung T, Wong TY, et al.
    Ophthalmology, 2014 Oct;121(10):2013-22.
    PMID: 24950592 DOI: 10.1016/j.ophtha.2014.04.041
    PURPOSE:
    To determine the ethnic differences in the distribution of intraocular pressure (IOP) and central corneal thickness (CCT) in a multi-ethnic Asian population by self-reported ethnicity and genetic ancestry.
    DESIGN:
    Population-based, cross-sectional study.
    PARTICIPANTS:
    A total of 10 033 adults (3353 Chinese, 3280 Malays, and 3400 Indians) aged >40 years.
    METHODS:
    Participants underwent standardized systemic and ocular examinations and interviewer-administered questionnaires for risk factor assessment. The IOP readings were obtained by Goldmann applanation tonometry (Haag-Streit, Konig, Switzerland) before pupil dilation. The CCT was measured with ultrasound pachymetry. Genetic ancestry was derived using principal component (PC) analysis. Regression models were used to investigate the association of IOP and CCT with potential risk factors and genetic ancestry.
    MAIN OUTCOME MEASURES:
    Intraocular pressure and CCT.
    RESULTS:
    After excluding participants with a history of glaucoma surgery or medication, refractive surgery, corneal edema, or corneal dystrophy, IOP and CCT readings were available for 3251 Chinese, 3232 Malays, and 3317 Indians. The mean IOP readings in the Chinese, Malay, and Indian participants were 14.3±3.1, 15.3±3.7, and 15.8±2.9 mmHg, respectively (P 
    Matched MeSH terms: Intraocular Pressure/physiology*
  3. Zhao D, Kim MH, Pastor-Barriuso R, Chang Y, Ryu S, Zhang Y, et al.
    Invest Ophthalmol Vis Sci, 2014 Oct;55(10):6244-50.
    PMID: 25183763 DOI: 10.1167/iovs.14-14151
    To examine the longitudinal association between age and intraocular pressure (IOP) in a large sample of Korean men and women.
    Matched MeSH terms: Intraocular Pressure/physiology*
  4. Fang SY, Wan Abdul Halim WH, Mat Baki M, Din NM
    Graefes Arch Clin Exp Ophthalmol, 2018 Apr;256(4):783-790.
    PMID: 29492688 DOI: 10.1007/s00417-018-3919-7
    PURPOSE: Obstructive sleep apnea syndrome (OSAS) patients are at risk of glaucoma but the risk increases if they have higher intraocular pressure (IOP) while sleeping. We aim to evaluate the postural effect of upright and prolong supine positions on IOP in these patients.

    METHODS: This is a cross-sectional study involving 27 patients with symptoms of OSAS seen at a tertiary institutional center and 25 normal controls performed between June 2015 and June 2016. All patients and controls underwent a polysomnography (PSG) test and were diagnosed with OSAS based on the apnea-hypopnea index (AHI). Patients are those with OSAS symptoms and had AHI > 5, whereas controls are staffs from the ophthalmology clinic without clinical criteria for OSAS and had PSG result of AHI

    Matched MeSH terms: Intraocular Pressure/physiology*
  5. Tajunisah I, Reddy SC, Fathilah J
    Graefes Arch Clin Exp Ophthalmol, 2007 Dec;245(12):1851-7.
    PMID: 17901971
    BACKGROUND: A case-controlled prospective study was conducted to evaluate the diurnal variation of intraocular pressure (IOP); the mean, the amplitude of variation and the peak and trough times of pressure readings in the suspected open-angle glaucoma patients as compared with a control group. We also looked at the outcome of these suspects after diurnal variation of IOP measurements.

    METHODS: Diurnal variation of intraocular pressure was measured in 202 eyes of suspected open-angle glaucoma patients and 100 control eyes, at 4-hourly intervals for 24 hours (phasing). Based on the phasing results, optic disc changes and visual field defects, the patients were diagnosed as primary open angle glaucoma (POAG), normal tension glaucoma (NTG), ocular hypertension (OHT), or physiologic cup (PC), or still remained as glaucoma suspects due to inconclusive diagnosis. The last group (glaucoma suspects) was then followed up 6-monthly for their eventual outcome.

    RESULTS: The highest percentage of suspected glaucoma patients had peak (maximum) readings in the mid-morning (10-11 A.M.) and trough (minimum) readings after midnight (2-3 A.M.); the highest percentage of control group had peak readings in the late evening (6-7 P.M.) and trough readings after midnight (2-3 A.M.). The mean amplitude of variance was 6 mm Hg in suspected glaucoma group and 4 mm Hg in the control group. After 'phasing', 18.8% of the suspected glaucoma patients were diagnosed as POAG, 16.8% as NTG, 5% as OHT, and 28.7% as physiologic cup; 30.9% remained as glaucoma suspects. After 4 years follow-up, 70% of the glaucoma suspects still remained as glaucoma suspects, 6.7% developed NTG and another 6.7% POAG; 16.6% were normal.

    CONCLUSIONS: Serial measurement of IOP ( phasing) in a 24-hour period is still needed, in order not to miss the peak and the trough IOP readings in suspected open-angle glaucoma patients, which helps in better management of glaucoma. Among 30.9% of patients who remained as glaucoma suspects after the initial phasing, 13.4% developed NTG/POAG over a period of 4 years.

    Matched MeSH terms: Intraocular Pressure/physiology*
  6. Li HB, You QS, Xu LX, Sun LX, Abdul Majid AS, Xia XB, et al.
    Cell Physiol Biochem, 2017;43(5):2117-2132.
    PMID: 29065394 DOI: 10.1159/000484231
    BACKGROUND/AIMS: The aim of the present study is to investigate the effect of long non-coding RNA-MALAT1 (LncRNA-MALAT1) on retinal ganglion cell (RGC) apoptosis mediated by the PI3K/Akt signaling pathway in rats with glaucoma.

    METHODS: RGCs were isolated and cultured, and monoclonal antibodies (anti-rat Thy-1, Brn3a and RBPMS) were examined by immunocytochemistry. An overexpression vector MALAT1-RNA activation (RNAa), gene knockout vector MALAT1-RNA interference (RNAi), and control vector MALAT1-negative control (NC) were constructed. A chronic high intraocular pressure (IOP) rat model of glaucoma was established by episcleral vein cauterization. The RGCs were divided into the RGC control, RGC pressure, RGC pressure + MALAT1-NC, RGC pressure + MALAT1-RNAi and RGC pressure + MALAT1-RNAa groups. Sixty Sprague-Dawley (SD) rats were randomly divided into the normal, high IOP, high IOP + MALAT1-NC, high IOP + MALAT1-RNAa and high IOP + MALAT1-RNAi groups. qRT-PCR and western blotting were used to detect the expression levels of LncRNA-MALAT1 and PI3K/Akt. Terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL) and flow cytometry were used to detect RGC apoptosis.

    RESULTS: Immunocytochemistry revealed that the cultured RGCs reached 90% purity. Compared with the RGC pressure + MALAT1-NC group, the RGC pressure + MALAT1-RNAa group exhibited elevated expression levels of MALAT1, lower total protein levels of PI3K and Akt and decreased RGC apoptosis, while these expression levels were reversed in the RGC pressure + MALAT1-RNAi group. RGC numbers and PI3K/Akt expression levels in the high IOP model groups were lower than those in the normal group. In the high IOP + MALAT1-RNAa group, the mRNA and protein expression levels of PI3K/Akt were reduced but higher than those in the other three high IOP model groups. Additionally, RGC numbers in the high IOP + MALAT1-RNAa group were lower than those in the normal group but higher than those in the other three high IOP model groups.

    CONCLUSION: Our study provides evidence that LncRNA-MALAT1 could inhibit RGC apoptosis in glaucoma through activation of the PI3K/Akt signaling pathway.

    Matched MeSH terms: Intraocular Pressure/physiology
  7. Singh M, Kaur B
    Int Ophthalmol, 1992 May;16(3):163-6.
    PMID: 1452420
    Postural behaviour of intraocular pressure (IOP) was studied in 29 glaucomatous eyes before and after argon laser trabeculoplasty (ALT) and compared with that of 60 normal eyes. Although argon laser trabeculoplasty was successful in lowering the IOP below 21 mm Hg, it produced little effect on the postural behaviour of the IOP. No significant change was observed in the amplitude of postural rise of IOP in ALT treated eyes.
    Matched MeSH terms: Intraocular Pressure/physiology*
  8. Samsudin A, Eames I, Brocchini S, Khaw PT
    J Glaucoma, 2016 Jan;25(1):e39-45.
    PMID: 25719236 DOI: 10.1097/IJG.0000000000000243
    PURPOSE: ExPress devices are available as P50 and P200 models, the numbers related to their luminal diameters in μm. We compared their Poiseuille's Law-based theoretical resistance values with experimental values and correlated these with their luminal dimensions derived from electron microscopy.

    METHODS: Scanning electron microscopy was performed on P50 and P200 devices. Bench-top flow studies were performed to find the resistances of the devices. Devices were also incorporated into a perfused, ex vivo porcine sclera model to test and compare their control of pressure, with and without overlying scleral flaps, and with trabeculectomies.

    RESULTS: The luminal dimensions of the P200 device were 206.4±3.3 and 204.5±0.9 μm at the subconjunctival space and anterior chamber ends, respectively. Those of the P50 device were 205.0±5.8 and 206.9±3.7 μm, respectively. There were no significant differences between the P200 and P50 devices (all P>0.05). The resistances of the P200 and P50 devices were 0.010±0.001 and 0.054±0.002 mm Hg/μL/min, respectively (P<0.05). Equilibrium pressures with overlying scleral flaps were 17.81±3.30 mm Hg for the P50, 17.31±4.24 mm Hg for the P200, and 16.28±6.67 mm Hg for trabeculectomies (P=0.850).

    CONCLUSIONS: The luminal diameters of both devices are externally similar. The effective luminal diameter of the P50 is much larger than 50 μm. Both devices have low resistance values, making them unlikely to prevent hypotony on their own. They lead to similar equilibrium pressures as the trabeculectomy procedure when inserted under the scleral flap.

    Matched MeSH terms: Intraocular Pressure/physiology
  9. Samsudin A, Eames I, Brocchini S, Khaw PT
    J Glaucoma, 2016 07;25(7):e704-12.
    PMID: 26561421 DOI: 10.1097/IJG.0000000000000360
    PURPOSE: Intraocular pressure and aqueous humor flow direction determined by the scleral flap immediately after trabeculectomy are critical determinants of the surgical outcome. We used a large-scale model to objectively measure the influence of flap thickness and shape, and suture number and position on pressure difference across the flap and flow of fluid underneath it.

    METHODS: The model exploits the principle of dynamic and geometric similarity, so while dimensions were up to 30× greater than actual, the flow had similar properties. Scleral flaps were represented by transparent 0.8- and 1.6-mm-thick silicone sheets on an acrylic plate. Dyed 98% glycerin, representing the aqueous humor was pumped between the sheet and plate, and the equilibrium pressure measured with a pressure transducer. Image analysis based on the principle of dye dilution was performed using MATLAB software.

    RESULTS: The pressure drop across the flap was larger with thinner flaps, due to reduced rigidity and resistance. Doubling the surface area of flaps and reducing the number of sutures from 5 to 3 or 2 also resulted in larger pressure drops. Flow direction was affected mainly by suture number and position, it was less toward the sutures and more toward the nearest free edge of the flap. Posterior flow of aqueous humor was promoted by placing sutures along the sides while leaving the posterior edge free.

    CONCLUSION: We demonstrate a new physical model which shows how changes in scleral flap thickness and shape, and suture number and position affect pressure and flow in a trabeculectomy.

    Matched MeSH terms: Intraocular Pressure/physiology*
  10. Md Din N, Tomkins-Netzer O, Talat L, Taylor SR, Isa H, Bar A, et al.
    J Glaucoma, 2016 07;25(7):598-604.
    PMID: 26900824 DOI: 10.1097/IJG.0000000000000379
    PURPOSE: To determine risk factors for intraocular pressure (IOP) elevation and glaucoma in children with nonjuvenile idiopathic arthritis-related uveitis and any IOP-related changes in the retinal nerve fiber layer (RNFL) thickness.

    PATIENTS AND METHODS: Clinical data were collected from children attending a tertiary referral uveitis clinic between May 2010 and October 2012. We assigned 206 eyes of 103 children into 32 normal eyes, 108 normotensive uveitics (NU), 41 hypertensive uveitics (HU: raised IOP without glaucomatous disc), and 25 glaucomatous uveitics (GU: raised IOP with glaucomatous disc). Risk factors for raised IOP, glaucoma and steroid response (SR) were evaluated and RNFL thickness across groups was compared with determine changes related to raised IOP.

    RESULTS: IOP elevation occurred in 40 patients (38.8%) or 66/174 eyes with uveitis (37.9%); and SR occurred in 35.1% of all corticosteroid-treated eyes. Chronic uveitis was a significant risk factor for raised IOP [odds ratio (OR)=9.28, P=0.001], glaucoma, and SR (OR=8.4, P<0.001). Higher peak IOP was also a risk factor for glaucoma (OR=1.4, P=0.003). About 70% of SR eyes were high responders (IOP increase >15 mm Hg from baseline), associated with younger age and corticosteroid injections. Although no significant RNFL thinning was detected between HU and NU eyes, significant thinning was detected in the inferior quadrant of GU (121.3±28.9 μm) compared with NU eyes (142.1±32.0 μm, P=0.043).

    CONCLUSIONS: Children with chronic uveitis are at higher risk of raised IOP and glaucoma. Thinning of the inferior RNFL quadrant may suggest glaucomatous changes in uveitic children with raised IOP.

    Study site: Moorfields Eye Hospital, London
    Matched MeSH terms: Intraocular Pressure/physiology*
  11. Din NM, Talat L, Isa H, Tomkins-Netzer O, Barton K, Lightman S
    Graefes Arch Clin Exp Ophthalmol, 2016 Dec;254(12):2439-2448.
    PMID: 27495303
    PURPOSE: To determine whether the second eyes (SE) of patients with bilateral uveitic glaucoma undergoing filtration surgery have more glaucomatous progression in terms of visual acuity, visual field (VF) and optic nerve changes compared to the first eyes (FE).

    METHODS: This retrospective study analysed data of 60 eyes from 30 patients with bilateral uveitic glaucoma who had undergone glaucoma surgery in both eyes on separate occasions. Humphrey VF progression was assessed using the Progressor software.

    RESULTS: The pre-operative IOP between the FE (43.1 ± 7.7 mmHg) and SE (40 ± 8.7 mmHg) was not statistically significant (p = 0.15). IOP reduction was greater in the FE (64 %) than SE (59.7 %) post-operatively, but the mean IOP at the final visit in the FE (12.3 ± 3.9 mmHg) and SE (14.5 ± 7 mmHg) was not statistically different (p = 0.2). There was no significant change in mean logMAR readings pre and post-operatively (0.45 ± 0.6 vs 0.37 ± 0.6, p = 0.4) or between the FE and SE. The number of SE with CDR > 0.7 increased by 23 % compared to the FE. From 23 available VFs, five SE (21.7 %) progressed at a median of five locations (range 1-11 points) with a mean local slope reduction of 1.74 ± 0.45 dB/year (range -2.39 to -1.26), whereas only one FE progressed. However, there was no significant difference between mean global rate of progression between the FE (-0.9 ± 1.6 dB/year) and SE (-0.76 ± 2.1 dB/year, p = 0.17) in the Humphrey VF.

    CONCLUSION: In eyes with bilateral uveitic glaucoma requiring glaucoma surgery, the SEs had more progressed points on VF and glaucomatous disc progression compared to FEs at the final visit.

    Matched MeSH terms: Intraocular Pressure/physiology*
  12. Niven TCS, Azhany Y, Rohana AJ, Karunakar TVN, Thayanithi S, Jelinar Noor MN, et al.
    J Glaucoma, 2019 01;28(1):7-13.
    PMID: 30461551 DOI: 10.1097/IJG.0000000000001120
    PURPOSE: The purpose of this study was to determine the association between cigarette smoking and the severity of primary angle closure glaucoma (PACG) in Malay patients residing in Malaysia.

    METHODS: A cross-sectional study was conducted involving 150 Malay PACG patients between April 2014 and August 2016. Ocular examination was performed including Humphrey visual field (HVF) 24-2 analysis assessment. On the basis of the 2 consecutive reliable HVFs, the severity of glaucoma was scored according to modified Advanced Glaucoma Intervention Study (AGIS) by 2 masked investigators and classified as mild, moderate, and severe. Those with retinal diseases, neurological diseases, memory problem, and myopia ≥4 diopters were excluded. Their smoking status and details were obtained by validated questionnaire from Singapore Malay Eye Study (SiMES). The duration of smoking, number of cigarettes per day, and pack/year was also documented. Multiple linear regression analysis was conducted.

    RESULTS: There was a significant association between education level and severity of PACG (P=0.001). However, there was no significant association between cigarette smoking and severity of glaucoma (P=0.080). On the basis of multivariate analysis, a linear association was identified between cigarette smoked per day (adjusted b=0.73; 95% CI: 0.54, 1.45; P<0.001) and body mass index (adjusted b=0.32; 95% CI: 0.07, 1.35; P=0.032) with AGIS score.

    CONCLUSIONS: There was no significant association between cigarette smoking and severity of PACG. Cigarette smoked per day among the smokers was associated with severity of PACG. However, because of the detrimental effect of smoking, cessation of smoking should be advocated to PACG patients.

    Matched MeSH terms: Intraocular Pressure/physiology
  13. Abdullah SN, Sanderson GF, Husni MA, Maddess T
    PMID: 32034583 DOI: 10.1007/s10633-020-09750-7
    PURPOSE: To compare two forms of perimetry that use large contrast-modulated grating stimuli in terms of: their relative diagnostic power, their independent diagnostic information about glaucoma and their utility for mfVEPs. We evaluated a contrast-threshold mfVEP in normal controls using the same stimuli as one of the tests.

    METHODS: We measured psychophysical contrast thresholds in one eye of 16 control subjects and 19 patients aged 67.8 ± 5.65 and 71.9 ± 7.15, respectively, (mean ± SD). Patients ranged in disease severity from suspects to severe glaucoma. We used the 17-region FDT-perimeter C20-threshold program and a custom 9-region test (R9) with similar visual field coverage. The R9 stimuli scaled their spatial frequencies with eccentricity and were modulated at lower temporal frequencies than C20 and thus did not display a clear spatial frequency-doubling (FD) appearance. Based on the overlapping areas of the stimuli, we transformed the C20 results to 9 measures for direct comparison with R9. We also compared mfVEP-based and psychophysical contrast thresholds in 26 younger (26.6 ± 7.3 y, mean ± SD) and 20 older normal control subjects (66.5 ± 7.3 y) control subjects using the R9 stimuli.

    RESULTS: The best intraclass correlations between R9/C20 thresholds were for the central and outer regions: 0.82 ± 0.05 (mean ± SD, p ≤ 0.0001). The areas under receiver operator characteristic plots for C20 and R9 were as high as 0.99 ± 0.012 (mean ± SE). Canonical correlation analysis (CCA) showed significant correlation (r = 0.638, p = 0.029) with 1 dimension of the C20 and R9 data, suggesting that the lower and higher temporal frequency tests probed the same neural mechanism(s). Low signal quality made the contrast-threshold mfVEPs non-viable. The resulting mfVEP thresholds were limited by noise to artificially high contrasts, which unlike the psychophysical versions, were not correlated with age.

    CONCLUSION: The lower temporal frequency R9 stimuli had similar diagnostic power to the FDT-C20 stimuli. CCA indicated the both stimuli drove similar neural mechanisms, possibly suggesting no advantage of FD stimuli for mfVEPs. Given that the contrast-threshold mfVEPs were non-viable, we used the present and published results to make recommendations for future mfVEP tests.

    Matched MeSH terms: Intraocular Pressure/physiology
  14. Loh CC, Kamaruddin H, Bastion MC, Husain R, Mohd Isa H, Md Din N
    Ophthalmic Res, 2021;64(2):246-252.
    PMID: 32810853 DOI: 10.1159/000510925
    INTRODUCTION: The aim of the study was to evaluate the refractive status and ocular biometric parameters in subjects with angle closure in Malaysia.

    METHODS: This cross-sectional study was conducted on 171 primary angle closure patients (268 eyes). Visual acuity, refraction, and ocular biometry (central anterior chamber depth [ACD], axial length [AL], and lens thickness) were recorded. Vitreous cavity length (VL) and relative lens position (RLP) were calculated.

    RESULTS: A total of 92 Primary Angle Closure Suspect (PACS), 30 Primary Angle Closure (PAC), and 146 Primary Angle Closure Glaucoma (PACG) eyes were included. Chinese ethnicity formed the majority (n = 197, 73.5%), followed by Malay (n = 57, 21.3%) and Indian (n = 14, 5.2%). There was a significant female preponderance with a female to male ratio of 1.85. Mean age was 65.7 ± 7.7 years. Mean spherical equivalent was +0.33 ± 1.29 D. Approximately half (n = 137, 51%) of the eyes were hyperopic (spherical power ≥+0.5), with PACG having the highest percentage of hyperopia (n = 69, 50.4%). Myopia and emmetropia were present in 48 (17.9) and 83 (31%) eyes, respectively. Although AL and VL in myopia patients were significantly longer than emmetropic and hyperopic eyes (p < 0.001), the ACD was not significantly different (p = 0.427). While the RLP is smaller in myopic eyes, lens thickness was increased in hyperopic eyes. PACG was significantly higher in elderly patients compared to PACS and PAC (p = 0.005). A total of 37 (13.8%) eyes were blind (vision worse than 3/60) and 19 of them (51.3%) were female patients.

    CONCLUSION: A decrease in RLP is predictive of angle closure disease in myopic eyes, whereas increased lens thickness contributes to angle closure disease in hyperopic eyes.

    Matched MeSH terms: Intraocular Pressure/physiology*
  15. Ramli N, Nurull BS, Hairi NN, Mimiwati Z
    Prev Med, 2013;57 Suppl:S47-9.
    PMID: 23352960 DOI: 10.1016/j.ypmed.2013.01.007
    In the absence of raised intraocular pressure (IOP), haemodynamic parameters have been implicated in the development of normal tension glaucoma (NTG). The purpose of this study is to compare 24-hour IOP and haemodynamic parameters in NTG patients and non-glaucoma patients.
    Matched MeSH terms: Intraocular Pressure/physiology
  16. Marcus AJ, Iezhitsa I, Agarwal R, Vassiliev P, Spasov A, Zhukovskaya O, et al.
    Eur J Pharm Sci, 2018 Mar 01;114:245-254.
    PMID: 29274441 DOI: 10.1016/j.ejps.2017.12.015
    In an effort to find new ocular hypotensive drug candidates, a total of 27 condensed benzimidazoles based compounds were screened. This study was done in normotensive rats and rebound tonometry was used to estimate IOP. All compounds were topically applied as a single drop, unilaterally, at 3 different concentrations (0.1%, 0.2% and 0.4%). The contralateral eye was instilled with vehicle and served as control. The IOP reduction was measured up to 6h. It was observed that with a single topical instillation, compounds RU 551, RU 555, RU839 (pyrimido[1,2-a]benzimidazole derivatives), and RU 615 (imidazo[1,2-a]benzimidazole derivative) showed significant IOP lowering activities in ocular normotensive rats. All other compounds showed none, weak and inconsistent IOP lowering effect. The relationship between ability of IOP lowering and hypotensive activities was studied. According to the pharmacophore analysis, the class of pyrimido[1,2-a]benzimidazole is more promising than the class of imidazo[1,2-a]benzimidazole as a source of compounds with high IOP lowering activity. Pharmacophore analysis also showed that the critical features of high IOP lowering activity are methoxyphenyl and [phenyl]alkyl fragments, and non-conjugated six-membered heterocyclic ring.
    Matched MeSH terms: Intraocular Pressure/physiology
  17. Ting SL, Lim LT, Ooi CY, Rahman MM
    Asia Pac J Ophthalmol (Phila), 2019;8(3):229-232.
    PMID: 31165604 DOI: 10.22608/APO.2018433
    PURPOSE: To compare the measurement of intraocular pressure (IOP) of Icare rebound tonometer and Perkins applanation tonometer (PAT) during community eye screening and to assess the agreement between these 2 instruments.

    DESIGN: A cross-sectional, non-interventional study.

    METHODS: The IOP measurements by handheld Icare rebound tonometer (Finland) were first performed by a primary care physician. Then the IOP was measured using Perkins Mk3 applanation tonometer (Haag-Streit, UK) by an ophthalmologist who was masked to previous readings from the Icare rebound tonometer. The mean IOP measured by each tonometer was compared. Pearson correlation coefficient was used to explore the correlation between the IOP measurements of the 2 instruments. The level of agreement between them was assessed using the Bland and Altman method.

    RESULTS: A total of 420 left eyes were examined. The mean age of subjects was 38.6 ± 18.2 years. Approximately 67% of subjects were female. The mean IOP was 16.3 ± 4.0 mm Hg using Icare and 13.4 ± 2.3 mm Hg using PAT. Pearson correlation coefficient showed a moderate positive correlation between the 2 methods (r = +0.524, P < 0.001). Linear regression analysis revealed a slope of 0.28 with R² of 0.255. The mean difference between the 2 methods was 2.90 ± 3.5 mm Hg and the sample t-test revealed a statistically significant mean difference from 0 (P < 0.001). The 95% limits of agreement between the 2 methods were between -9.73 and 3.93 mm Hg.

    CONCLUSIONS: The handheld Icare rebound tonometer is a reasonably acceptable screening tool in community practices. However, Icare overestimated IOP with a mean of 2.90 mm Hg higher than the PAT. Thus, using Goldmann applanation tonometer as a confirmatory measurement tool of IOP is suggested.

    Matched MeSH terms: Intraocular Pressure/physiology*
  18. Ashworth J, Flaherty M, Pitz S, Ramlee A
    Acta Ophthalmol, 2015 Mar;93(2):e111-7.
    PMID: 25688487 DOI: 10.1111/aos.12607
    Purpose: The mucopolysaccharidoses (MPS) are a group of rare lysosomal storage disorders, characterized by the accumulation of glycosaminoglycans within multiple organ systems including the eye. This study aimed to determine the prevalence of glaucoma in patients with MPS, as well as the characteristics, diagnosis and management of patients with MPS and glaucoma.
    Methods: A multicentre retrospective case-note review was carried out by ophthalmologists from four tertiary referral centres to identify patients with MPS who had been treated for glaucoma. Clinical ophthalmological data were collected using standardized data collection forms.
    Results: Fourteen patients were identified (27 eyes) of 294 patients with MPS. The prevalence of glaucoma ranged from 2.1% to 12.5%. The median age at diagnosis of glaucoma was 8 years. Diagnostic evaluation of glaucoma was incomplete in many patients: intraocular pressure was documented in all eyes, but optic disc appearance was only assessed in 67%, central corneal thickness in 26%, visual fields in 19% and iridocorneal angle in 15%.
    Conclusions: Patients with MPS need regular assessment for possible glaucoma including during childhood. Multiple factors contribute to the challenges of assessment, diagnosis and monitoring of glaucoma in these patients.
    Keywords: Hunter; Hurler; Hurler-Scheie; Maroteaux-Lamy; Morquio; Scheie; glaucoma; mucopolysaccharidosis; prevalence.
    Matched MeSH terms: Intraocular Pressure/physiology
  19. Raman P, Suliman NB, Zahari M, Mohamad NF, Kook MS, Ramli N
    J Glaucoma, 2019 11;28(11):952-957.
    PMID: 31688446 DOI: 10.1097/IJG.0000000000001359
    PRECIS: This 5-year follow-up study on normal-tension glaucoma (NTG) patients demonstrated that those with baseline central visual field (VF) defect progress at a more increased rate compared with those with peripheral field defect.

    PURPOSE: The purpose of this study was to investigate the clinical characteristics, including 24-hour ocular perfusion pressure and risk of progression in patients with baseline central VF defect, as compared with those with peripheral VF defect in NTG.

    DESIGN: This was a prospective, longitudinal study.

    METHODS: A total of 65 NTG patients who completed 5 years of follow-up were included in this study. All the enrolled patients underwent baseline 24-hour intraocular pressure and blood pressure monitoring via 2-hourly measurements in their habitual position and had ≥5 reliable VF tests during the 5-year follow-up. Patients were assigned to two groups on the basis of VF defect locations at baseline, the central 10 degrees, and the peripheral 10- to 24-degree area. Modified Anderson criteria were used to assess global VF progression over 5 years. Kaplan-Meier analyses were used to compare the elapsed time of confirmed VF progression in the two groups. Hazard ratios for the association between clinical risk factors and VF progression were obtained by using Cox proportional hazards models.

    RESULTS: There were no significant differences between the patients with baseline central and peripheral VF defects in terms of demography, clinical, ocular and systemic hemodynamic factors. Eyes with baseline defects involving the central fields progressed faster (difference: βcentral=-0.78 dB/y, 95% confidence interval=-0.22 to -1.33, P=0.007) and have 3.56 times higher hazard of progressing (95% confidence interval=1.17-10.82, P=0.025) than those with only peripheral defects.

    CONCLUSION: NTG patients with baseline central VF involvement are at increased risk of progression compared with those with peripheral VF defect.

    Matched MeSH terms: Intraocular Pressure/physiology
  20. Chong KL, Samsudin A, Keng TC, Kamalden TA, Ramli N
    J Glaucoma, 2017 Feb;26(2):e37-e40.
    PMID: 27599172 DOI: 10.1097/IJG.0000000000000542
    PURPOSE: To evaluate the effect of nocturnal intermittent peritoneal dialysis (NIPD) on intraocular pressure (IOP) and anterior segment optical coherence tomography (ASOCT) parameters. Systemic changes associated with NIPD were also analyzed.

    METHODS: Observational study. Nonglaucomatous patients on NIPD underwent systemic and ocular assessment including mean arterial pressure (MAP), body weight, serum osmolarity, visual acuity, IOP measurement, and ASOCT within 2 hours both before and after NIPD. The Zhongshan Angle Assessment Program (ZAAP) was used to measure ASOCT parameters including anterior chamber depth, anterior chamber width, anterior chamber area, anterior chamber volume, lens vault, angle opening distance, trabecular-iris space area, and angle recess area. T tests and Pearson correlation tests were performed with P<0.05 considered statistically significant.

    RESULTS: A total of 46 eyes from 46 patients were included in the analysis. There were statistically significant reductions in IOP (-1.8±0.6 mm Hg, P=0.003), MAP (-11.9±3.1 mm Hg, P<0.001), body weight (-0.7±2.8 kg, P<0.001), and serum osmolarity (-3.4±2.0 mOsm/L, P=0.002) after NIPD. All the ASOCT parameters did not have any statistically significant changes after NIPD. There were no statistically significant correlations between the changes in IOP, MAP, body weight, and serum osmolarity (all P>0.05).

    CONCLUSIONS: NIPD results in reductions in IOP, MAP, body weight, and serum osmolarity in nonglaucomatous patients.

    Matched MeSH terms: Intraocular Pressure/physiology*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links