METHODS: We included patients from a multicentre longitudinal cohort (recruited between May 1, 2013, and Dec 31, 2019) with active SLE (SLEDAI-2K ≥6) coinciding with an abnormality in at least one of 13 routine laboratory tests, at a visit designated as baseline. At 12 months, we analysed associations between thresholds of improvement in individual laboratory test results, measured as continuous variables, and five clinical outcomes using logistic regression. Primary outcomes were damage accrual and lupus low disease activity state (LLDAS), and secondary outcomes were modified SLE responder index (mSRI), physician global assessment (PGA) improvement of at least 0·3, and flare.
FINDINGS: We included 1525 patients (1415 [93%] women and 110 [7%] men, 1328 [87%] Asian ethnicity) in separate subsets for each laboratory test. The strongest associations with LLDAS and damage protection were seen with improvements in proteinuria (complete response: adjusted odds ratio [OR] 62·48, 95% CI 18·79-208·31 for LLDAS, OR 0·22, 95% CI 0·10-0·49 for damage accrual), albumin (complete response: adjusted OR 6·46, 95% CI 2·20-18·98 for LLDAS, OR 0·42, 95% CI 0·20-1·22 for damage accrual), haemoglobin (complete response: adjusted OR 1·97, 95% CI 1·09-3·53 for LLDAS, OR 0·33, 95% CI 0·15-0·71 for damage accrual), erythrocyte sedimentation rate (complete response: adjusted OR 1·71, 95% CI 1·10-2·67 for LLDAS, OR 0·53, 95% CI 0·30-0·94 for damage accrual), and platelets (complete response: adjusted OR 4·82, 95% CI 1·54-15·07 for LLDAS, OR 0·49, 95% CI 0·20-1·19 for damage accrual). Improvement in serological tests were mainly associated with PGA and mSRI. White cell and lymphocyte count improvements were least predictive.
INTERPRETATION: Improvements in several routine laboratory tests correspond with clinical outcomes in SLE over 12 months. Tests with the strongest associations were discrepant with laboratory tests included in current trial endpoints, and associations were observed across a range of improvement thresholds including incomplete resolution. These findings suggest the need to revise the use of laboratory test results in SLE trial endpoints.
FUNDING: Abbvie.
AIM OF THE STUDY: However, so far there is no literature available on the anti-inflammatory activity of this species. Henceforth, based on the above background and our previous laboratory findings, we hypothesize that phytoconstituents of A. elliptica could possess anti-inflammatory potential against inflammatory mediators including prostaglandin-E2 (PGE2), cyclooxegenase-2 (COX-2) and cytokines (IL-1β and IL-6).
MATERIALS AND METHODS: Vacuum and column chromatography techniques were employed for the isolation of phytoconstituents. The structure elucidation was carried out using HRESI-MS, 1H and 13C-NMR analysis and compared with the published literature. For cytotoxicity analysis, 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay was performed on peripheral blood mononuclear cells. In-vitro anti-inflammatory activities were evaluated against the levels of PGE2, COX-2, IL-1β and IL-6 in lipopolysaccharide (LPS)-induced human plasma using enzyme-linked immunosorbent assay and radioimmunoassay.
RESULTS: Unprecedentedly, chromatographic purification of methanolic leaves extract afforded five flavones namely vitexin, isovitexin, orientin, isoorientin, schaftoside with three flavanols; kaempferol, myricetin and rutin from A elliptica. In cell viability analysis, isolates did not present cytotoxicity up to 50 μM. In anti-inflammatory evaluation, orientin and isoorientin exhibited strong (≥70%), while isovitexin and vitexin produced strong to moderate (50-69%) PGE2, COX-2, IL-1β and IL-6 inhibition at 25 and 50 μM. Isoorientin, orientin, isovitexin, and vitexin showed significant (p
CASE REPORT: We describe here an unusual case of leptospirosis complicated by haemolytic anaemia in a 70-year-old man with established kidney failure. He presented with an abrupt onset of shortness of breath, flushing and erythematous rash after completing haemodialysis. The patient's biochemistry test samples were however rejected twice as they were grossly haemolysed. The integrated auto-verification alert system implemented in the hospital's laboratory information system alerted the staff of the possibility of in vivo haemolysis.
DISCUSSION: The auto-verification alert system effectively distinguishes between in vitro and in vivo haemolysis and as such can be utilised as a diagnostic aid in patients with suspected intravascular haemolysis.
CASE PRESENTATION: A 30-year-old man was retrieved from the jungle with severe weight loss and abdominal symptoms. He succumbed to death despite 22 days of intensive medical treatment. An autopsy revealed a ruptured gangrenous ileal volvulus with peritonitis and subdiaphragmatic abscess. Further laboratory analysis detected systemic Candida tropicalis and intestinal gramnegative bacterial sepsis, systemic Zika virus viremia, leptospirosis complicating rhabdomyolysis and disseminated intravascular coagulopathy, Type I Herpes Simplex virus infection of the tongue and upper gastrointestinal tract. The cause of death was the ruptured ileal volvulus, complicated with upper gastrointestinal bleeding due to Herpes simplex virus esophagitis in a malnourished patient with resolving leptospirosis and underlying Zika virus co-infection.
CONCLUSION: Rare clinical scenarios of adult-onset intestinal volvulus with concomitant multiple infections precludes clinical diagnosis and early treatment, leading to devastating consequences of clinical outcome. The positive clinical and postmortem correlation is a good learning lesson in many disciplines of medicine and science.
MATERIALS AND METHODS: An e-mail invitation to participate in an online survey was sent to hospital laboratories in Malaysia (n=140). Questions regarding methods for measuring creatinine, equations for calculating eGFR, eGFR reporting, the terminology used in reporting urine albumin, types of samples and the cut-off values used for normal albuminuria.
RESULTS: A total of 42/140 (30%) laboratories answered the questionnaire. The prevalent method used for serum creatinine measurement was the Jaffé method (88.1%) traceable to isotope-dilution mass spectrometry. eGFR was reported along with serum creatinine by 61.9% of laboratories while 33.3% of laboratories report eGFR on request. The formula used for eGFR reporting was mainly MDRD (64.3%) and results were reported as exact numbers even when the eGFR was <60 ml/min/1.73m2. The term microalbumin is still used by 83.3% of laboratories. There is a large heterogeneity among the labs regarding the type of sample recommended for measuring urine albumin, reference interval and reporting units.
CONCLUSION: It is evident that the laboratory assessment of chronic kidney disease in Malaysia is not standardised. It is essential to provide a national framework for standardised reporting of eGFR and urine albumin. Recommendations developed by the MACB CKD Task Force, if adopted by all laboratories, will lead to a reduction in this variability.