Displaying publications 1 - 20 of 91 in total

Abstract:
Sort:
  1. Zhang ZY, Yang WY, Dominiczak AF, Wang JG, Wu Y, Almustafa B, et al.
    Hypertension, 2019 11;74(5):1064-1067.
    PMID: 31422692 DOI: 10.1161/HYPERTENSIONAHA.119.13206
    Matched MeSH terms: Monitoring, Physiologic/methods
  2. Zakaria SM, Visvanathan R, Kamarudin K, Yeon AS, Md Shakaff AY, Zakaria A, et al.
    Sensors (Basel), 2015;15(12):30894-912.
    PMID: 26690175 DOI: 10.3390/s151229834
    The lack of information on ground truth gas dispersion and experiment verification information has impeded the development of mobile olfaction systems, especially for real-world conditions. In this paper, an integrated testbed for mobile gas sensing experiments is presented. The integrated 3 m × 6 m testbed was built to provide real-time ground truth information for mobile olfaction system development. The testbed consists of a 72-gas-sensor array, namely Large Gas Sensor Array (LGSA), a localization system based on cameras and a wireless communication backbone for robot communication and integration into the testbed system. Furthermore, the data collected from the testbed may be streamed into a simulation environment to expedite development. Calibration results using ethanol have shown that using a large number of gas sensor in the LGSA is feasible and can produce coherent signals when exposed to the same concentrations. The results have shown that the testbed was able to capture the time varying characteristics and the variability of gas plume in a 2 h experiment thus providing time dependent ground truth concentration maps. The authors have demonstrated the ability of the mobile olfaction testbed to monitor, verify and thus, provide insight to gas distribution mapping experiment.
    Matched MeSH terms: Monitoring, Physiologic
  3. Yuen NS, Ibrahim SB
    Arch Pediatr Adolesc Med, 2011 Jun;165(6):563-4.
    PMID: 21646590 DOI: 10.1001/archpediatrics.2011.80-a
    Matched MeSH terms: Monitoring, Physiologic/methods
  4. Yang Y, Wei X, Zhang N, Zheng J, Chen X, Wen Q, et al.
    Nat Commun, 2021 08 12;12(1):4876.
    PMID: 34385436 DOI: 10.1038/s41467-021-25075-8
    While the printed circuit board (PCB) has been widely considered as the building block of integrated electronics, the world is switching to pursue new ways of merging integrated electronic circuits with textiles to create flexible and wearable devices. Herein, as an alternative for PCB, we described a non-printed integrated-circuit textile (NIT) for biomedical and theranostic application via a weaving method. All the devices are built as fibers or interlaced nodes and woven into a deformable textile integrated circuit. Built on an electrochemical gating principle, the fiber-woven-type transistors exhibit superior bending or stretching robustness, and were woven as a textile logical computing module to distinguish different emergencies. A fiber-type sweat sensor was woven with strain and light sensors fibers for simultaneously monitoring body health and the environment. With a photo-rechargeable energy textile based on a detailed power consumption analysis, the woven circuit textile is completely self-powered and capable of both wireless biomedical monitoring and early warning. The NIT could be used as a 24/7 private AI "nurse" for routine healthcare, diabetes monitoring, or emergencies such as hypoglycemia, metabolic alkalosis, and even COVID-19 patient care, a potential future on-body AI hardware and possibly a forerunner to fabric-like computers.
    Matched MeSH terms: Monitoring, Physiologic/instrumentation; Monitoring, Physiologic/methods
  5. Wong, Jackson Sing Ann, Yew, Hoe Tung
    MyJurnal
    In this modern and fast-moving world, elderly’s safety and security have become an important issue. According to the World Population Prospects of the United Nations 2015, there is 12.3 per cent population aged 60 and above globally and it is the fastest growing population at a rate of 3.26 per cent per year. In order to reduce the worries about the elderly living alone at home, Elderly Monitoring System is required for continuous monitoring. “Fall†is one of the critical incidents for the elderly living alone as it causes serious injuries. A fall detection system using global system for mobile communication can help to reduce the time of unaware of their next of kin.
    Matched MeSH terms: Monitoring, Physiologic
  6. Wong A, Abu Bakar MZ
    Am J Otolaryngol, 2021 01 04;42(2):102869.
    PMID: 33429183 DOI: 10.1016/j.amjoto.2020.102869
    PURPOSE: The nasocardiac reflex is known but not well researched. We aimed to ascertain the electrocardiographic features of the reflex and to chronologically map the heart rhythm dynamics during nasoendoscopy. We also intended to identify variables that could potentially affect the occurrence of this reflex.

    MATERIAL AND METHODS: A prospective, quasi-experimental physiological study. Selected healthy subjects were observed electrocardiographically for 60 s continuously in three equal phases of 20 s each - baseline phase, nasoendoscopic phase, and recovery phase (post-nasoendoscopy). Heart rate fluctuations were charted, followed by identification of a positive nasocardiac reflex group of subjects and a negative group. Analyses against multiple variables were done.

    RESULTS: A total of 53 subjects were analysed. Heart rate during the baseline phase was 81.0 ± 9.9, nasoendoscopic phase was 72.7 ± 10.1, and recovery phase was 75.2 ± 9.6. Sixteen subjects (30.2%) had a positive nasocardiac reflex, and they remained in sinus rhythm with no occurrences of skipped beats, atrioventricular blocks or asystoles. One subject (1.9%) developed temporary ectopic premature ventricular contractions after nasoendoscopy. No variables were found affecting the incidence of a nasocardiac reflex in our study.

    CONCLUSIONS: The pattern of heart rate dynamics was consistent as heart rates drop rapidly upon endoscope insertion and recover in some measure after its withdrawal. Although all our subjects remained asymptomatic, clinicians should not overlook the risks of a severe nasocardiac reflex when performing nasoendoscopy. We recommend that electrical cardiac monitoring be part of the management of vasovagal responses during in-office endonasal procedures.

    Matched MeSH terms: Monitoring, Physiologic/methods*
  7. Wolkow AP, Rajaratnam SMW, Wilkinson V, Shee D, Baker A, Lillington T, et al.
    Sleep Health, 2020 06;6(3):366-373.
    PMID: 32340910 DOI: 10.1016/j.sleh.2020.03.005
    OBJECTIVES: This study examined the influence of a wrist-worn heart rate drowsiness detection device on heavy vehicle driver safety and sleep and its ability to predict driving events under naturalistic conditions.

    DESIGN: Prospective, non-randomized trial.

    SETTING: Naturalistic driving in Malaysia.

    PARTICIPANTS: Heavy vehicle drivers in Malaysia were assigned to the Device (n = 25) or Control condition (n = 34).

    INTERVENTION: Both conditions were monitored for driving events at work over 4-weeks in Phase 1, and 12-weeks in Phase 2. In Phase 1, the Device condition wore the device operated in the silent mode (i.e., no drowsiness alerts) to examine the accuracy of the device in predicting driving events. In Phase 2, the Device condition wore the device in the active mode to examine if drowsiness alerts from the device influenced the rate of driving events (compared to Phase 1).

    MEASUREMENTS: All participants were monitored for harsh braking and harsh acceleration driving events and self-reported sleep duration and sleepiness daily.

    RESULTS: There was a significant decrease in the rate of harsh braking events (Rate ratio = 0.48, p 

    Matched MeSH terms: Monitoring, Physiologic/instrumentation*
  8. Widyastuti Y, Gentong M, Astuti W
    Med J Malaysia, 2020 05;75(Suppl 1):24-27.
    PMID: 32471966
    BACKGROUND: Procedural sedation and analgesia (PSAA) or monitoring anaesthesia care (MAC) must provide analgesia, amnesia and hypnosis with complete and rapid recovery that suits a particular operative procedure with minimum side effects. For a child undergoing a procedure, a major deciding factor is whether it is painful or not. Deep Sedation is required during the procedures to allay the anxiety, pain, and movement. The appropriate level of sedation depth will prevent consciousness, over-sedation, optimisation of dosage and prevents adverse complications. There are few studies about consciousness in pediatric patients during methotrexate injection with monitored anaesthesia care (MAC). The objective is to find out the incidence of consciousness of paediatric patients during methotrexate injection with Monitored Anaesthesia Care.

    METHODS: Observational study conducted on 68 patients (1- 18 yrs.) with physical status of ASA II during methotrexate injection with MAC at the RSUP dr. Sardjito. The depth of anaesthesia was monitored with Observer's Alertness Assessment Sedation Scale (OAAS) every two minutes. Consciousness was defined as OAAS=5, or if there is volunteer movement of patients. The result was analysed and categorised according to age, sex, physical status, Body Mass Index (BMI) and anaesthesia's medication of patients.

    RESULTS: Positive consciousness in paediatric patients based on OASS score at 2-minute and 4-minutes was 26.5% and 3.2% respectively, and was rescued by additional propofol 2mg/kg body weight.

    CONCLUSION: The incidence of paediatric consciousness in patients during methotrexate injection with Monitored Anaesthesia Care (MAC) in the Sardjito General Hospital is 26.5% (2-minute after induction) and 3.2% (4-minute after induction), and this is considerably high thus needing futher prevention.

    Matched MeSH terms: Monitoring, Physiologic*
  9. Venugopal A, Mohammad R, Koslan MFS, Sayd Bakar SR, Ali A
    Materials (Basel), 2021 May 06;14(9).
    PMID: 34066461 DOI: 10.3390/ma14092414
    The environmental condition in which the Royal Malaysian Airforce is currently operating its aircraft is prone to corrosion. This is due to the high relative humidity and temperature. With most of its aircraft being in the legacy aircraft era, the aircraft's main construction consists of the aluminium 2024 material. However, this material is prone to corrosion, thus reducing fatigue life and leading to fatigue failure. Using the concept of either Safe Life or Damage Tolerance as its fatigue design philosophy, the RMAF adopts the Aircraft Structure Integrity Program (ASIP) to monitor its structural integrity. With the current problem of not having the structural limitation on corrosion-damaged structure, the RMAF has embarked on its fatigue testing method. Finite Element (FE) studies and flight tests were conducted, and the outcome is summarized. The conclusion is that the longeron tested on the aircraft can withstand the operational load, and its yield strength is below the ultimate yield strength of the material. These research outcomes will also enhance the ASIP for other aircraft platforms in the RMAF fleet for its structure life assessment or service life extension program.
    Matched MeSH terms: Monitoring, Physiologic
  10. Velo P, Zakaria A
    J Med Imaging Radiat Sci, 2017 Mar;48(1):39-42.
    PMID: 31047208 DOI: 10.1016/j.jmir.2016.10.010
    It is important to monitor the spatial resolution of a gamma camera on a weekly basis to acquire medical images with accurate quantitative information. A simple and fast computer program with a graphical user interface to analyze spatial resolution was successfully developed using MATLAB. The results were compared with those obtained from the standard processing system available in our gamma camera. The spatial resolution calculated using MATLAB was 1.24% lower than using the standard processing system. The developed program is cost effective, faster, and provides an easy platform for the physicists and technologists to analyze the spatial resolution based on the image of the line source.
    Matched MeSH terms: Monitoring, Physiologic
  11. Teh Sin Yin, Ong Ker Hsin, Soh Keng Lin, Khoo Michael Boon Chong, Teoh Wei Li
    Sains Malaysiana, 2015;44:1067-1075.
    The existing optimal design of the fixed sampling interval S2-EWMA control chart to monitor the sample variance of a process is based on the average run length (ARL) criterion. Since the shape of the run length distribution changes with the magnitude of the shift in the variance, the median run length (MRL) gives a more meaningful explanation about the in-control and out-of-control performances of a control chart. This paper proposes the optimal design of the S2-EWMA chart, based on the MRL. The Markov chain technique is employed to compute the MRLs. The performances of the S2-EWMA chart, double sampling (DS) S2 chart and S chart are evaluated and compared. The MRL results indicated that the S2-EWMA chart gives better performance for detecting small and moderate variance shifts, while maintaining almost the same sensitivity as the DS S2 and S charts toward large variance shifts, especially when the sample size increases.
    Matched MeSH terms: Monitoring, Physiologic
  12. Tan I, Delilkan AE
    Med J Malaysia, 1993 Dec;48(4):381-91.
    PMID: 8183160
    Modern anaesthesia carries a definite although small risk. The risk from general and regional anaesthesia is reviewed, the causes explored, and preventive strategies discussed. Although anaesthesia may never be 100% safe, a knowledge of the risk and causes enables us to work towards this goal.
    Matched MeSH terms: Monitoring, Physiologic
  13. Shyamsunder R, Eswaran C, Sriraam N
    J Med Syst, 2007 Apr;31(2):109-16.
    PMID: 17489503
    The volume of patient monitoring video acquired in hospitals is very huge and hence there is a need for better compression of the same for effective storage and transmission. This paper presents a new motion segmentation technique, which improves the compression of patient monitoring video. The proposed motion segmentation technique makes use of a binary mask, which is obtained by thresholding the standard deviation values of the pixels along the temporal axis. Two compression methods, which make use of the proposed motion segmentation technique, are presented. The first method uses MPEG-4 coder and 9/7-biorthogonal wavelet for compressing the moving and stationary portions of the video respectively. The second method uses 5/3-biorthogonal wavelet for compressing both the moving and the stationary portions of the video. The performances of these compression algorithms are evaluated in terms of PSNR and bitrate. From the experimental results, it is found that the proposed motion technique improves the performance of the MPEG-4 coder. Among the two compression methods presented, the MPEG-4 based method performs better for bitrates less than 767 Kbps whereas for bitrates above 767 Kbps the performance of the wavelet based method is found superior.
    Matched MeSH terms: Monitoring, Physiologic/methods*
  14. Shukri A, Green S, Bradley DA
    Appl Radiat Isot, 1995 6 1;46(6-7):625.
    PMID: 7633384
    Matched MeSH terms: Monitoring, Physiologic
  15. Shivaraja TR, Remli R, Kamal N, Wan Zaidi WA, Chellappan K
    Sensors (Basel), 2023 Mar 31;23(7).
    PMID: 37050713 DOI: 10.3390/s23073654
    Ambulatory EEGs began emerging in the healthcare industry over the years, setting a new norm for long-term monitoring services. The present devices in the market are neither meant for remote monitoring due to their technical complexity nor for meeting clinical setting needs in epilepsy patient monitoring. In this paper, we propose an ambulatory EEG device, OptiEEG, that has low setup complexity, for the remote EEG monitoring of epilepsy patients. OptiEEG's signal quality was compared with a gold standard clinical device, Natus. The experiment between OptiEEG and Natus included three different tests: eye open/close (EOC); hyperventilation (HV); and photic stimulation (PS). Statistical and wavelet analysis of retrieved data were presented when evaluating the performance of OptiEEG. The SNR and PSNR of OptiEEG were slightly lower than Natus, but within an acceptable bound. The standard deviations of MSE for both devices were almost in a similar range for the three tests. The frequency band energy analysis is consistent between the two devices. A rhythmic slowdown of theta and delta was observed in HV, whereas photic driving was observed during PS in both devices. The results validated the performance of OptiEEG as an acceptable EEG device for remote monitoring away from clinical environments.
    Matched MeSH terms: Monitoring, Physiologic
  16. Saiful Mohammad Iezham Suhaimi, Nouruddeen Bashir, Nor Asiah Muhamad, Mohd Aizam Talib
    MyJurnal
    Contaminated and ageing transmission line insulators often suffer from temporary or permanent loss of their insulating properties due to flashover resulting in power system failure. Surface discharges are precursors to flashover. To pre-empt any occurrence of flashovers, utility companies monitor the conditions of their insulators. There are numerous insulator surface monitoring techniques such as Leakage Current, Acoustics, and Infrared. However, these techniques may not be suitable for in-situ condition monitoring of the insulators as they are prone to noise, affected by environmental conditions or contact methods. Monitoring of the UV signals emitted by the surface discharges of these insulators has been reported to be a promising technique. However, comprehensive studies on this technique is lacking, especially on aged insulators. This paper investigated the UV signals of contaminated and aged insulators detected during surface discharge activities using UV pulse method. The time and frequency domain of the UV signals were analysed for a group of insulator samples having varying levels of contamination and phases of ageing. Results show that there is a strong correlation between the contamination level and ageing of the insulators with the amplitude and harmonic components of the UV signals. This correlation can useful to monitor in-service insulator surface conditions.
    Matched MeSH terms: Monitoring, Physiologic
  17. Safi A, Ahmad Z, Jehangiri AI, Latip R, Zaman SKU, Khan MA, et al.
    Sensors (Basel), 2022 Nov 01;22(21).
    PMID: 36366109 DOI: 10.3390/s22218411
    In recent years, fire detection technologies have helped safeguard lives and property from hazards. Early fire warning methods, such as smoke or gas sensors, are ineffectual. Many fires have caused deaths and property damage. IoT is a fast-growing technology. It contains equipment, buildings, electrical systems, vehicles, and everyday things with computing and sensing capabilities. These objects can be managed and monitored remotely as they are connected to the Internet. In the Internet of Things concept, low-power devices like sensors and controllers are linked together using the concept of Low Power Wide Area Network (LPWAN). Long Range Wide Area Network (LoRaWAN) is an LPWAN product used on the Internet of Things (IoT). It is well suited for networks of things connected to the Internet, where terminals send a minute amount of sensor data over large distances, providing the end terminals with battery lifetimes of years. In this article, we design and implement a LoRaWAN-based system for smart building fire detection and prevention, not reliant upon Wireless Fidelity (Wi-Fi) connection. A LoRa node with a combination of sensors can detect smoke, gas, Liquefied Petroleum Gas (LPG), propane, methane, hydrogen, alcohol, temperature, and humidity. We developed the system in a real-world environment utilizing Wi-Fi Lora 32 boards. The performance is evaluated considering the response time and overall network delay. The tests are carried out in different lengths (0-600 m) and heights above the ground (0-2 m) in an open environment and indoor (1st Floor-3rd floor) environment. We observed that the proposed system outperformed in sensing and data transfer from sensing nodes to the controller boards.
    Matched MeSH terms: Monitoring, Physiologic/methods
  18. Razzaque MA, Javadi SS, Coulibaly Y, Hira MT
    Sensors (Basel), 2014 Dec 29;15(1):440-64.
    PMID: 25551485 DOI: 10.3390/s150100440
    Wireless body sensor networks (WBSNs) for healthcare and medical applications are real-time and life-critical infrastructures, which require a strict guarantee of quality of service (QoS), in terms of latency, error rate and reliability. Considering the criticality of healthcare and medical applications, WBSNs need to fulfill users/applications and the corresponding network's QoS requirements. For instance, for a real-time application to support on-time data delivery, a WBSN needs to guarantee a constrained delay at the network level. A network coding-based error recovery mechanism is an emerging mechanism that can be used in these systems to support QoS at very low energy, memory and hardware cost. However, in dynamic network environments and user requirements, the original non-adaptive version of network coding fails to support some of the network and user QoS requirements. This work explores the QoS requirements of WBSNs in both perspectives of QoS. Based on these requirements, this paper proposes an adaptive network coding-based, QoS-aware error recovery mechanism for WBSNs. It utilizes network-level and user-/application-level information to make it adaptive in both contexts. Thus, it provides improved QoS support adaptively in terms of reliability, energy efficiency and delay. Simulation results show the potential of the proposed mechanism in terms of adaptability, reliability, real-time data delivery and network lifetime compared to its counterparts.
    Matched MeSH terms: Monitoring, Physiologic/instrumentation
  19. Ranjit S, Sim K, Besar R, Tso C
    Biomed Imaging Interv J, 2009 Jul;5(3):e32.
    PMID: 21611059 MyJurnal DOI: 10.2349/biij.5.3.e32
    By applying a hexagon-diamond search (HDS) method to an ultrasound image, the path of an object is able to be monitored by extracting images into macro-blocks, thereby achieving image redundancy is reduced from one frame to another, and also ascertaining the motion vector within the parameters searched. The HDS algorithm uses six search points to form the six sides of the hexagon pattern, a centre point, and a further four search points to create diamond pattern within the hexagon that clarifies the focus of the subject area.
    Matched MeSH terms: Monitoring, Physiologic
  20. Ran Z, Wu K, Matsuoka K, Jeen YT, Wei SC, Ahuja V, et al.
    J Gastroenterol Hepatol, 2021 Mar;36(3):637-645.
    PMID: 32672839 DOI: 10.1111/jgh.15185
    Inflammatory bowel disease (IBD) has increased in incidence and prevalence in Asian countries since the end of the 20th century. Moreover, differences in the cause, phenotypes, and natural history of IBD between the East and West have been recognized. Therefore, the Asian Organization for Crohn's and Colitis and the Asia Pacific Association of Gastroenterology have established recommendations on medical management of IBD in Asia. Initially, the committee members drafted 40 recommendations, which were then assessed according to Grading of Recommendations Assessment, Development and Evaluation. Eight statements were rejected as this indicated that consensus had not been reached. The recommendations encompass pretreatment evaluation; medical management of active IBD; medical management of IBD in remission; management of IBD during the periconception period and pregnancy; surveillance strategies for colitis-associated cancer; monitoring side effects of thiopurines and methotrexate; and infections in IBD.
    Matched MeSH terms: Monitoring, Physiologic*