DESIGN: A prospective study.
SETTING: A tertiary hospital in Malaysia.
POPULATION: A cohort of 193 term nulliparous women with intact membranes.
METHODS: Prior to labour induction, cervical fluid was obtained via a vaginal speculum and tested for IGFBP-1, followed by TVUS and finally Bishop score. After each assessment the procedure-related pain was scored from 0 to 10. Cut-off values for Bishop score and cervical length were obtained from the receiver operating characteristic (ROC) curve. Multivariable logistic regression analysis was performed.
MAIN OUTCOMES MEASURES: Vaginal delivery and vaginal delivery within 24 hours of starting induction.
RESULTS: Bedside IGFBP-1 testing is better tolerated than Bishop score, but is less well tolerated than TVUS [median (interquartile range) of pain scores: 5 (4-5) versus 6 (5-7) versus 3 (2-3), respectively; P < 0.001]. IGFBP-1 independently predicted vaginal delivery (adjusted odds ratio, AOR 5.5; 95% confidence interval, 95% CI 2.3-12.9) and vaginal delivery within 24 hours of induction (AOR 4.9; 95% CI 2.1-11.6) after controlling for Bishop score (≥4 or ≥5), cervical length (≤29 or ≤27 mm), and other significant characteristics for which the Bishop score and TVUS were not predictive of vaginal delivery after adjustment. IGFBP-1 has 81% sensitivity, 59% specificity, positive and negative predictive values of 82 and 58%, respectively, and positive and negative likelihood ratios of 2.0 and 0.3 for vaginal delivery, respectively.
CONCLUSION: IGFBP-1 better predicted vaginal delivery than BS or TVUS, and may help guide decision making regarding labour induction in nulliparous women.
TWEETABLE ABSTRACT: IGFBP-1: a stronger independent predictor of labour induction success than Bishop score or cervical sonography.
MATERIAL AND METHODS: A randomized trial was conducted in the University of Malaya Medical Center. A total of 163 term multiparas (no dropouts) with unripe cervixes (Bishop score ≤5) scheduled for labor induction were randomized to outpatient or inpatient Foley catheter. Primary outcomes were delivery during "working hours" 08:00-18:00 h and maternal satisfaction on allocated care (assessed by 11-point visual numerical rating score 0-10, with higher score indicating more satisfied).
CLINICAL TRIAL REGISTRATION: ISRCTN13534944.
RESULTS: Comparing outpatient and inpatient arms, delivery during working hours were 54/82 (65.9%) vs. 48/81 (59.3%) (relative risk 1.1, 95% CI 0.9-1.4, p = 0.421) and median maternal satisfaction visual numerical rating score was 9 (interquartile range 9-9) vs. 9 (interquartile range 8-9, p = 0.134), repectively. Duration of hospital stay and membrane rupture to delivery interval were significantly shorter in the outpatient arm: 35.8 ± 20.2 vs. 45.2 ± 16.2 h (p = 0.001) and 4.1 ± 2.9 vs. 5.3 ± 3.6 h (p = 0.020), respectively. Other maternal and neonatal secondary outcomes were not significantly different.
CONCLUSIONS: The trial failed to demonstrate the anticipated increase in births during working hours with outpatient compared with inpatient induction of labor with Foley catheter in parous women with an unripe cervix. Hospital stay and membrane rupture to delivery interval were significantly shortened in the outpatient group. The rate of maternal satisfaction was high in both groups and no significant differences were found.
OBJECTIVE: This study aimed to evaluate if visual feedback focusing on the perineum reduced the length of the active second stage of labor in comparison with the control.
STUDY DESIGN: A randomized controlled trial was conducted in the University Malaya Medical Centre from December 2021 to August 2022. Nulliparous women about to commence the active second stage, at term, with singleton gestation, reassuring fetal status, and no contraindication for vaginal delivery were randomized to live viewing of the maternal introitus (intervention) or maternal face (sham/placebo control) as visual biofeedback during their pushing. A video camera Bluetooth-linked to a tablet computer display screen was used; in the intervention arm, the camera was focused on the introitus, and in the control arm, on the maternal face. Participants were instructed to watch the display screen during their pushing. The primary outcomes were the intervention-to-delivery interval and maternal satisfaction with the pushing experience assessed using a 0-to-10 visual numerical rating scale. Secondary outcomes included mode of delivery, perineal injury, delivery blood loss, birthweight, umbilical cord arterial blood pH and base excess at birth, Apgar score at 1 and 5 minutes, and neonatal intensive care unit admission. Data were analyzed with the t test, Mann-Whitney U test, chi-square test, and Fisher exact test, as appropriate.
RESULTS: A total of 230 women were randomized (115 to intervention and 115 to control arm). The active second stage duration (intervention-to-delivery interval) was a median (interquartile range) of 16 (11-23) and 17 (12-31) minutes (P=.289), and maternal satisfaction with the pushing experience was 9 (8-10) and 7 (6-7) (P