MATERIAL AND METHODS: One hundred patients were randomly recruited and then further randomly divided into two groups of 50 patients each. The first group used the POC PCT test along with the standard sepsis parameter monitoring, while the second group had the standard monitoring only (C-reactive protein [CRP] level, total white count, temperature and tracheal aspirate culture). Serial PCT test results and CRP levels were monitored on days 1, 3, 7 and 9. The patients were followed up for 28-day mortality.
RESULTS: Eighty-five patients completed the trial, of whom 43 were in the PCT group and 42 were in the control group. The PCT group had a significantly lower mean (SD) antibiotic treatment duration (10.28 [2.68] days) than the control group (11.52 [3.06]). The mean (SD) difference was -1.25 (95% confidence interval [CI], -2.48 to 0.01; t-statistic [df] = -1.997 [83]; P = 0.049). The PCT group also had a higher number of antibiotic-free days alive during the 28 days after VAP onset than the control group (mean [SD], 10.79 [7.61] vs. 8.72 [6.41]). The Sequential Organ Failure Assessment score was the sole factor for the decrease in duration after VAP onset (regression coefficient β [95% CI], -0.70 [-1.19 to -0.20]; P = 0.006).
CONCLUSIONS: The POC procalcitonin test can reduce the antibiotic treatment duration in patients with VAP.
METHODS: This prospective cross-sectional study consecutively recruited 494 patients with suspected dengue from a health clinic in Malaysia. Both RDTs were performed onsite. The evaluated ELISA and reference tests were performed in a virology laboratory. The reference tests comprised of a reverse transcription-polymerase chain reaction and three ELISAs for the detection of dengue NS1 antigen, IgM and IgG antibodies, respectively. The diagnostic performance of evaluated tests was computed using STATA version 12.
RESULTS: The sensitivity and specificity of ViroTrack were 62.3% (95%CI 55.6-68.7) and 95.0% (95%CI 91.7-97.3), versus 66.5% (95%CI 60.0-72.6) and 95.4% (95%CI 92.1-97.6) for SD NS1 ELISA, and 52.4% (95%CI 45.7-59.1) and 97.7% (95%CI 95.1-99.2) for NS1 component of SD Bioline, respectively. The combination of the latter with its IgM and IgG components were able to increase test sensitivity to 82.4% (95%CI 76.8-87.1) with corresponding decrease in specificity to 87.4% (95%CI 82.8-91.2). Although a positive test on any of the NS1 assays would increase the probability of dengue to above 90% in a patient, a negative result would only reduce this probability to 23.0-29.3%. In contrast, this probability of false negative diagnosis would be further reduced to 14.7% (95%CI 11.4-18.6) if SD Bioline NS1/IgM/IgG combo was negative.
CONCLUSIONS: The performance of ViroTrack Dengue Acute was comparable to SD Dengue NS1 Ag ELISA. Addition of serology components to SD Bioline Dengue Duo significantly improved its sensitivity and reduced its false negative rate such that it missed the fewest dengue patients, making it a better point-of-care diagnostic tool. New RDT like ViroTrack Dengue Acute may be a potential alternative to existing RDT if its combination with serology components is proven better in future studies.
METHODS: Participants consisting of junior doctors were randomized into either the (1) gamified or the (2) conventional educational approach for ultrasonographic training.
RESULTS: A total of 31 junior doctors participated in this study (16 participants in gamified arm, 15 in the conventional arm after one participant from the conventional arm dropped out due to work commitment). Two-way mixed ANOVA test showed that there was no statistically significant interaction between the types of educational approach and time of testing (pre-test, post-test, 2 months post-training) for both theoretical knowledge score and practical skills score, with F(2, 58) = 39.6, p point-of-care ultrasonographic training.
FINDINGS: A total of 274 venous blood was collected from normal healthy adults during the community screening programmes. The performance of POC devices, Afinion and Quo-test were compared to central laboratory HPLC method; Adams A1c HA 8160. Both POC devices showed good correlation to HA 8160 with r = 0.94 (p < 0.001) and r = 0.95 (p < 0.001) for Afinion and Quo-test respectively. The means difference were statistically higher between POC and HA 8160 with 0.23% (95% CI 0.19-0.26, p < 0.001) and 0.29% (95% CI 0.24-0.34, p < 0.001) for Afinion and Quo-test respectively.
CONCLUSIONS: Both POC devices could be considered in health clinics for diabetes management but not to be used for the diagnostic purposes.
METHODS: The POCT was used to test 170 serum specimens collected through measles surveillance or vaccination programmes in Ethiopia, Malaysia and the Russian Federation: 69 were positive for measles immunoglobulin M (IgM) antibodies, 74 were positive for rubella IgM antibodies and 7 were positive for both. Also tested were 282 oral fluid specimens from the measles, mumps and rubella (MMR) surveillance programme of the United Kingdom of Great Britain and Northern Ireland. The Microimmune measles IgM capture enzyme immunoassay was the gold standard for comparison. A panel of 24 oral fluids was used to investigate if measles virus haemagglutinin (H) and nucleocapsid (N) genes could be amplified by polymerase chain reaction directly from used POCT strips.
FINDINGS: With serum POCT showed a sensitivity and specificity of 90.8% (69/76) and 93.6% (88/94), respectively; with oral fluids, sensitivity and specificity were 90.0% (63/70) and 96.2% (200/208), respectively. Both H and N genes were reliably detected in POCT strips and the N genes could be sequenced for genotyping. Measles virus genes could be recovered from POCT strips after storage for 5 weeks at 20-25 °C.
CONCLUSION: The POCT has the sensitivity and specificity required of a field-based test for measles diagnosis. However, its role in global measles control programmes requires further evaluation.