Displaying publications 1 - 20 of 72 in total

Abstract:
Sort:
  1. Adi O, Fong CP, Sum KM, Ahmad AH
    Am J Emerg Med, 2021 04;42:263.e1-263.e4.
    PMID: 32994082 DOI: 10.1016/j.ajem.2020.09.011
    Airway assessment is important in emergency airway management. A difficult airway can lead to life-threatening complications. A perfect airway assessment tool does not exist and unanticipated difficulty will remain unforeseen. Current bedside clinical predictors of the difficult airway are unreliable but airway ultrasound can be used as an adjunct to predict difficult laryngoscopy. We report a case of a 60-year-old man presenting to the emergency department with shortness of breath, hoarseness of voice and stridor. Airway ultrasound revealed a large laryngeal mass narrowing the upper airway, extending to bilateral vocal cords with heterogenous echogenicity. In view of impending complete upper airway obstruction, acute respiratory distress and airway ultrasound findings, urgent emergency tracheostomy was chosen as definitive airway over endotracheal intubation or surgical cricothyroidotomy. Point of care ultrasound (POCUS) was used to evaluate this patient with severe upper airway obstruction. A laryngeal mass was detected by ultrasound and this pointed towards the presence of a difficult airway. POCUS was a good non-invasive tool used for airway assessment in this uncooperative and unstable patient. Ultrasound predictors of the difficult airway include the inability to visualize the hyoid bone, short hyomental distance ratio, high pretracheal anterior neck thickness and large tongue size. Besides airway assessment, ultrasound can also help to predict endotracheal tube size, confirm intubation and guide emergency airway procedures such as cricothyroidotomy and tracheostomy. Point of care ultrasound of the upper airway can be used in airway assessment to identify distorted airway anatomy, pathological lesions and guide treatment decisions.
    Matched MeSH terms: Point-of-Care Systems*
  2. Grigg MJ, William T, Barber BE, Parameswaran U, Bird E, Piera K, et al.
    J Clin Microbiol, 2014 Jun;52(6):2053-60.
    PMID: 24696029 DOI: 10.1128/JCM.00181-14
    Plasmodium knowlesi causes severe and fatal malaria in Malaysia. Microscopic misdiagnosis is common and may delay appropriate treatment. P. knowlesi can cross-react with "species-specific" parasite lactate dehydrogenase (pLDH) monoclonal antibodies used in rapid diagnostic tests (RDTs) to detect P. falciparum and P. vivax. At one tertiary-care hospital and two district hospitals in Sabah, we prospectively evaluated two combination RDTs for malaria diagnosis by using both a pan-Plasmodium-pLDH (pan-pLDH)/P. falciparum-specific-pLDH (Pf-pLDH) RDT (OptiMAL-IT) and a non-P. falciparum VOM-pLDH/Pf-HRP2 RDT (CareStart). Differential cross-reactivity among these combinations was hypothesized to differentiate P. knowlesi from other Plasmodium monoinfections. Among 323 patients with PCR-confirmed P. knowlesi (n = 193), P. falciparum (n = 93), and P. vivax (n = 37) monoinfections, the VOM-pLDH individual component had the highest sensitivity for nonsevere (35%; 95% confidence interval [CI], 27 to 43%) and severe (92%; CI, 81 to 100%) P. knowlesi malaria. CareStart demonstrated a P. knowlesi sensitivity of 42% (CI, 34 to 49%) and specificity of 74% (CI, 65 to 82%), a P. vivax sensitivity of 83% (CI, 66 to 93%) and specificity of 71% (CI, 65 to 76%), and a P. falciparum sensitivity of 97% (CI, 90 to 99%) and specificity of 99% (CI, 97 to 100%). OptiMAL-IT demonstrated a P. knowlesi sensitivity of 32% (CI, 25 to 39%) and specificity of 21% (CI, 15 to 29%), a P. vivax sensitivity of 60% (CI, 42 to 75%) and specificity of 97% (CI, 94 to 99%), and a P. falciparum sensitivity of 82% (CI, 72 to 89%) and specificity of 39% (CI, 33 to 46%). The combination of CareStart plus OptiMAL-IT for P. knowlesi using predefined criteria gave a sensitivity of 25% (CI, 19 to 32%) and specificity of 97% (CI, 92 to 99%). Combining two RDT combinations was highly specific for P. knowlesi malaria diagnosis; however, sensitivity was poor. The specificity of pLDH RDTs was decreased for P. vivax and P. falciparum because of P. knowlesi cross-reactivity and cautions against their use alone in areas where P. knowlesi malaria is endemic. Sensitive P. knowlesi-specific RDTs and/or alternative molecular diagnostic tools are needed in areas where P. knowlesi malaria is endemic.
    Matched MeSH terms: Point-of-Care Systems*
  3. Hussain A, Via G, Melniker L, Goffi A, Tavazzi G, Neri L, et al.
    Crit Care, 2020 12 24;24(1):702.
    PMID: 33357240 DOI: 10.1186/s13054-020-03369-5
    COVID-19 has caused great devastation in the past year. Multi-organ point-of-care ultrasound (PoCUS) including lung ultrasound (LUS) and focused cardiac ultrasound (FoCUS) as a clinical adjunct has played a significant role in triaging, diagnosis and medical management of COVID-19 patients. The expert panel from 27 countries and 6 continents with considerable experience of direct application of PoCUS on COVID-19 patients presents evidence-based consensus using GRADE methodology for the quality of evidence and an expedited, modified-Delphi process for the strength of expert consensus. The use of ultrasound is suggested in many clinical situations related to respiratory, cardiovascular and thromboembolic aspects of COVID-19, comparing well with other imaging modalities. The limitations due to insufficient data are highlighted as opportunities for future research.
    Matched MeSH terms: Point-of-Care Systems/standards*
  4. Gan RK, Sanchez Martinez A, Abu Hasan MA, Castro Delgado R, Arcos González P
    J Ultrasound, 2023 Jun;26(2):343-353.
    PMID: 36694072 DOI: 10.1007/s40477-022-00761-5
    INTRODUCTION: Necrotizing fasciitis (NF) is a rapidly progressive necrosis of the fascial layer with a high mortality rate. It is a life-threatening medical emergency that requires urgent treatment. Lack of skin finding in NF made diagnosis difficult and required a high clinical index of suspicion. The use of ultrasound may guide clinicians in improving diagnostic speed and accuracy, thus leading to improved management decisions and patient outcomes. This literature search aims to review the use of point-of-care ultrasonography in diagnosing necrotizing fasciitis.

    METHOD: We searched relevant electronic databases, including PUBMED, MEDLINE, and SCOPUS, and performed a systematic review. Keywords used were "necrotizing fasciitis" or "necrotising fasciitis" or "necrotizing soft tissue infections" and "point-of-care ultrasonography" "ultrasonography" or "ultrasound". No temporal limitation was set. An additional search was performed via google scholar, and the top 100 entry was screened.

    RESULTS: Among 540 papers screened, only 21 were related to diagnosing necrotizing fasciitis using ultrasonography. The outcome includes three observational studies, 16 case reports, and two case series, covering the period from 1976 to 2022.

    CONCLUSION: Although the use of ultrasonography in diagnosing NF was published in several papers with promising results, more studies are required to investigate its diagnostic accuracy and potential to reduce time delay before surgical intervention, morbidity, and mortality.

    Matched MeSH terms: Point-of-Care Systems*
  5. Swathirajan CR, Vignesh R, Boobalan J, Solomon SS, Saravanan S, Balakrishnan P
    J Med Microbiol, 2017 Oct;66(10):1379-1382.
    PMID: 28901908 DOI: 10.1099/jmm.0.000514
    BACKGROUND: Sustainable suppression of HIV replication forms the basis of anti-retroviral therapy (ART) medication. Thus, reliable quantification of HIV viral load has become an essential factor to monitor the effectiveness of the ART. Longer turnaround-time (TAT), batch testing and technical skills are major drawbacks of standard real-time PCR assays.

    METHODS: The performance of the point-of-care Xpert HIV-1 viral load assay was evaluated against the Abbott RealTime PCR m2000rt system. A total of 96 plasma specimens ranging from 2.5 log10 copies ml-1 to 4.99 log10 copies ml-1 and proficiency testing panel specimens were used. Precision and accuracy were checked using the Pearson correlation co-efficient test and Bland-Altman analysis.

    RESULTS: Compared to the Abbott RealTime PCR, the Xpert HIV-1 viral load assay showed a good correlation (Pearson r=0.81; P<0.0001) with a mean difference of 0.27 log10 copies ml-1 (95 % CI, -0.41 to 0.96 log10 copies ml-1; sd, 0.35 log10 copies ml-1).

    CONCLUSION: Reliable and ease of testing individual specimens could make the Xpert HIV-1 viral load assay an efficient alternative method for ART monitoring in clinical management of HIV disease in resource-limited settings. The rapid test results (less than 2 h) could help in making an immediate clinical decision, which further strengthens patient care.

    Matched MeSH terms: Point-of-Care Systems*
  6. Nanthasurasak P, See HH, Zhang M, Guijt RM, Breadmore MC
    Angew Chem Int Ed Engl, 2019 03 18;58(12):3790-3794.
    PMID: 30614157 DOI: 10.1002/anie.201812077
    An electrokinetic platform was developed for extracting small-molecule pharmaceuticals from a dried blood spot. Through the exclusion of liquid reagents and use of low field strength (6 V cm-1 ), the electroextraction of a drug from a dried blood spot, deposited on a polymer inclusion membrane (PIM), could be realised while in transit in the mail. In transit sample preparation provides a potential solution to in situ sample degradation and may accelerate the workflow upon arrival of a patient sample at the analytical facility. The electroextraction method was enabled through our discovery of the use of 15-20 μm thin PIMs as electrophoretic separation medium in absence of liquid reagents. Here, a PIM consisting of cellulose triacetate as polymer base, 2-nitrophenyl octyl ether as plasticizer and 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide as carrier was used. The PIM, was packaged with two 12 V batteries to supply the separation voltage. A blood spot containing berberine chloride was deposited and dried before the applying the separation potential, allowing for the electroextraction while the packaged device was shipped in internal mail. Upon arrival in the analytical laboratory, the PIM was analysed using a fluorescence microscope with photon multiplier tube, quantifying the berberine extracted away from the sample matrix. This platform represents a new opportunity for processing clinical samples during transport to the laboratory, saving time and manual handling to accelerate the time to result.
    Matched MeSH terms: Point-of-Care Systems
  7. Warrener L, Slibinskas R, Chua KB, Nigatu W, Brown KE, Sasnauskas K, et al.
    Bull World Health Organ, 2011 Sep 01;89(9):675-82.
    PMID: 21897488 DOI: 10.2471/BLT.11.088427
    OBJECTIVE: To evaluate the performance of a newly developed point-of-care test (POCT) for the detection of measles-specific IgM antibodies in serum and oral fluid specimens and to assess if measles virus nucleic acid could be recovered from used POCT strips.

    METHODS: The POCT was used to test 170 serum specimens collected through measles surveillance or vaccination programmes in Ethiopia, Malaysia and the Russian Federation: 69 were positive for measles immunoglobulin M (IgM) antibodies, 74 were positive for rubella IgM antibodies and 7 were positive for both. Also tested were 282 oral fluid specimens from the measles, mumps and rubella (MMR) surveillance programme of the United Kingdom of Great Britain and Northern Ireland. The Microimmune measles IgM capture enzyme immunoassay was the gold standard for comparison. A panel of 24 oral fluids was used to investigate if measles virus haemagglutinin (H) and nucleocapsid (N) genes could be amplified by polymerase chain reaction directly from used POCT strips.

    FINDINGS: With serum POCT showed a sensitivity and specificity of 90.8% (69/76) and 93.6% (88/94), respectively; with oral fluids, sensitivity and specificity were 90.0% (63/70) and 96.2% (200/208), respectively. Both H and N genes were reliably detected in POCT strips and the N genes could be sequenced for genotyping. Measles virus genes could be recovered from POCT strips after storage for 5 weeks at 20-25 °C.

    CONCLUSION: The POCT has the sensitivity and specificity required of a field-based test for measles diagnosis. However, its role in global measles control programmes requires further evaluation.

    Matched MeSH terms: Point-of-Care Systems/standards*
  8. Lai AKH, Noor Azhar AMB, Bustam AB, Tiong XT, Chan HC, Ahmad RB, et al.
    BMC Med Educ, 2020 Aug 12;20(1):263.
    PMID: 32787921 DOI: 10.1186/s12909-020-02173-7
    BACKGROUND: Although gamification increases user engagement, its effectiveness in point-of-care ultrasonographic training has yet to be fully established. This study was conducted with the primary outcome of evaluating its effectiveness in point-of-care ultrasonographic training as compared to conventional approach.

    METHODS: Participants consisting of junior doctors were randomized into either the (1) gamified or the (2) conventional educational approach for ultrasonographic training.

    RESULTS: A total of 31 junior doctors participated in this study (16 participants in gamified arm, 15 in the conventional arm after one participant from the conventional arm dropped out due to work commitment). Two-way mixed ANOVA test showed that there was no statistically significant interaction between the types of educational approach and time of testing (pre-test, post-test, 2 months post-training) for both theoretical knowledge score and practical skills score, with F(2, 58) = 39.6, p point-of-care ultrasonographic training.

    Matched MeSH terms: Point-of-Care Systems*
  9. Singh S, Numan A, Cinti S
    Anal Chem, 2022 Jan 11;94(1):26-40.
    PMID: 34802244 DOI: 10.1021/acs.analchem.1c03856
    Matched MeSH terms: Point-of-Care Systems
  10. Citartan M
    Talanta, 2021 Sep 01;232:122436.
    PMID: 34074421 DOI: 10.1016/j.talanta.2021.122436
    Dot blot assays have always been associated with antibodies as the main molecular recognition element, which are widely employed in a myriad of diagnostic applications. With the rising of aptamers as the equivalent molecular recognition elements of antibodies, dot blot assays are also one of the diagnostic avenues that should be scrutinized for their amenability with aptamers as the potential surrogates of antibodies. In this review, the stepwise procedures of an aptamer-based dot blot assays are underscored before reviewing the existing aptamer-based dot blot assays developed so far. Most of the applications center on monitoring the progress of SELEX and as the validatory assays to assess the potency of aptamer candidates. For the purpose of diagnostics, the current effort is still languid and as such possible suggestions to galvanize the move to spur the aptamer-based dot blot assays to a point-of-care arena are discussed.
    Matched MeSH terms: Point-of-Care Systems
  11. Zainol Abidin AS, Rahim RA, Md Arshad MK, Fatin Nabilah MF, Voon CH, Tang TH, et al.
    Sensors (Basel), 2017 May 22;17(5).
    PMID: 28531146 DOI: 10.3390/s17051180
    Anxiety is a psychological problem that often emerges during the normal course of human life. The detection of anxiety often involves a physical exam and a self-reporting questionnaire. However, these approaches have limitations, as the data might lack reliability and consistency upon application to the same population over time. Furthermore, there might be varying understanding and interpretations of the particular question by the participant, which necessitating the approach of using biomarker-based measurement for stress diagnosis. The most prominent biomarker related to stress, hormone cortisol, plays a key role in the fight-or-flight situation, alters the immune response, and suppresses the digestive and the reproductive systems. We have taken the endeavour to review the available aptamer-based biosensor (aptasensor) for cortisol detection. The potential point-of-care diagnostic strategies that could be harnessed for the aptasensing of cortisol were also envisaged.
    Matched MeSH terms: Point-of-Care Systems*
  12. Fraga MV, Stoller JZ, Glau CL, De Luca D, Rempell RG, Wenger JL, et al.
    Pediatrics, 2019 11;144(5).
    PMID: 31615954 DOI: 10.1542/peds.2019-1401
    Point-of-care ultrasound is currently widely used across the landscape of pediatric care. Ultrasound machines are now smaller, are easier to use, and have much improved image quality. They have become common in emergency departments, ICUs, inpatient wards, and outpatient clinics. Recent growth of supportive evidence makes a strong case for using point-of-care ultrasound for pediatric interventions such as vascular access (in particular, central-line placement), lumbar puncture, fluid drainage (paracentesis, thoracentesis, pericardiocentesis), suprapubic aspiration, and soft tissue incision and drainage. Our review of this evidence reveals that point-of-care ultrasound has become a powerful tool for improving procedural success and patient safety. Pediatric patients and clinicians performing procedures stand to benefit greatly from point-of-care ultrasound, because seeing is believing.
    Matched MeSH terms: Point-of-Care Systems*
  13. Sculthorpe-Petley L, Liu C, Hajra SG, Parvar H, Satel J, Trappenberg TP, et al.
    J Neurosci Methods, 2015 Apr 30;245:64-72.
    PMID: 25701685 DOI: 10.1016/j.jneumeth.2015.02.008
    Event-related potentials (ERPs) may provide a non-invasive index of brain function for a range of clinical applications. However, as a lab-based technique, ERPs are limited by technical challenges that prevent full integration into clinical settings.
    Matched MeSH terms: Point-of-Care Systems*
  14. Arora H, Sharma A, Sharma S, Haron FF, Gafur A, Sayyed RZ, et al.
    Microorganisms, 2021 Apr 13;9(4).
    PMID: 33924471 DOI: 10.3390/microorganisms9040823
    Capsicum annuum L. is a significant horticulture crop known for its pungent varieties and used as a spice. The pungent character in the plant, known as capsaicinoid, has been discovered to have various health benefits. However, its production has been affected due to various exogenous stresses, including diseases caused by a soil-borne pathogen, Pythium spp. predominantly affecting the Capsicum plant in younger stages and causing damping-off, this pathogen can incite root rot in later plant growth stages. Due to the involvement of multiple Pythium spp. and their capability to disperse through various routes, their detection and diagnosis have become crucial. However, the quest for a point-of-care technology is still far from over. The use of an integrated approach with cultural and biological techniques for the management of Pythium spp. can be the best and most sustainable alternative to the traditionally used and hazardous chemical approach. The lack of race-specific resistance genes against Pythium spp. can be compensated with the candidate quantitative trait loci (QTL) genes in C. annuum L. This review will focus on the epidemiological factors playing a major role in disease spread, the currently available diagnostics in species identification, and the management strategies with a special emphasis on Pythium spp. causing damping-off and root rot in different cultivars of C. annuum L.
    Matched MeSH terms: Point-of-Care Systems
  15. Wicaksono DH, Syazwani IN, Ratnarathorn N, Sadir S, Shahir S, Ruckthong L, et al.
    Bioanalysis, 2019 May;11(9):855-873.
    PMID: 31084195 DOI: 10.4155/bio-2018-0190
    Aim: Time-based microfluidic absorption sampling was proposed using cotton fiber-based device made in swab stick. The assay was optimized and compared with conventional pipetted drop sampling using the same device. Materials & methods: Reagents were integrated into cotton fiber device for assessing concentration of analytes by the colorimetric detection method through time-based absorption sampling microfluidic system. All assay parameters were first optimized using conventional pipette-based drop sampling. Results: The color intensity is linear in the relevant concentration range of the analytes. The LOD are 0.189 mM for glucose and 6.56 μM for nitrite, respectively. These values are better than conventional drop sampling. The fiber-containing swab itself functions as sampling, assay and calibration device. Conclusion: Microfluidic cotton fiber-based assay device was fabricated and can determine analyte concentration in artificial salivary samples, colorimetrically, by time-based absorption sampling without the need of complex equipments.
    Matched MeSH terms: Point-of-Care Systems*
  16. Ley B, Luter N, Espino FE, Devine A, Kalnoky M, Lubell Y, et al.
    Malar J, 2015 Sep 29;14:377.
    PMID: 26416229 DOI: 10.1186/s12936-015-0896-8
    The only currently available drug that effectively removes malaria hypnozoites from the human host is primaquine. The use of 8-aminoquinolines is hampered by haemolytic side effects in glucose-6-phosphate dehydrogenase (G6PD) deficient individuals. Recently a number of qualitative and a quantitative rapid diagnostic test (RDT) format have been developed that provide an alternative to the current standard G6PD activity assays. The WHO has recently recommended routine testing of G6PD status prior to primaquine radical cure whenever possible. A workshop was held in the Philippines in early 2015 to discuss key challenges and knowledge gaps that hinder the introduction of routine G6PD testing. Two point-of-care (PoC) test formats for the measurement of G6PD activity are currently available: qualitative tests comparable to malaria RDT as well as biosensors that provide a quantitative reading. Qualitative G6PD PoC tests provide a binomial test result, are easy to use and some products are comparable in price to the widely used fluorescent spot test. Qualitative test results can accurately classify hemizygous males, heterozygous females, but may misclassify females with intermediate G6PD activity. Biosensors provide a more complex quantitative readout and are better suited to identify heterozygous females. While associated with higher costs per sample tested biosensors have the potential for broader use in other scenarios where knowledge of G6PD activity is relevant as well. The introduction of routine G6PD testing is associated with additional costs on top of routine treatment that will vary by setting and will need to be assessed prior to test introduction. Reliable G6PD PoC tests have the potential to play an essential role in future malaria elimination programmes, however require an improved understanding on how to best integrate routine G6PD testing into different health settings.
    Matched MeSH terms: Point-of-Care Systems
  17. Jairoun AA, Al-Hemyari SS, Shahwan M, Zyoud SH, El-Dahiyat F
    Sci Rep, 2024 Mar 27;14(1):7284.
    PMID: 38538618 DOI: 10.1038/s41598-024-56765-0
    Adherence to scheduled physician screenings for renal function monitoring in patients with chronic kidney disease (CKD) or those at high risk remains suboptimal despite the endorsement of regular screenings by several clinical practice guidelines. Our study aims to assess the effectiveness of a point-of-care CKD screening program led by these pharmacists using the PICCOLO device while recognizing the unique position of community pharmacists in primary care. We conducted an 11-month prospective point-of-care interventional research study in the United Arab Emirates to evaluate the performance of a community pharmacist-led CKD screening program for high-risk patients. Six diverse community pharmacies were selected based on staff availability, patient volume, and their offered range of services. Eligible individuals with risk factors for CKD were identified during medication evaluations. The PICCOLO Comprehensive Metabolic Panel facilitated on-site blood analysis, delivering estimated Glomerular Filtration Rate (eGFR) results within 10 to 15 min. Data also included eGFR categories, demographic information, and insights into lifestyle and health habits collected through a questionnaire. Pharmacists conducted comprehensive medication reviews and offered referrals and lifestyle guidance as part of the program. The study encompassed a total of 400 patients, with an average age of 69 ± 13.4 years within the study cohort. Notably, 38.8% (155 individuals) of the 400 patients were found to have undiagnosed CKD stages 3-5. Univariate logistic regression analysis revealed a significant association between a higher incidence of CKD stages 3-5 and factors such as older age, a history of hypertension, vascular disease, and diabetes mellitus. In the multivariate regression model, age and a history of diabetes mellitus emerged as significant predictors of an elevated risk of CKD. This study sheds light on the viability and impact of CKD screening programs conducted by community pharmacists, particularly in detecting CKD stages 3-5. The findings have implications for healthcare policies, as they can influence the enhancement of early detection and management of CKD. Moreover, these insights may catalyze focused screening initiatives and strengthen collaboration between community pharmacies and healthcare systems to benefit patients at high risk of CKD.
    Matched MeSH terms: Point-of-Care Systems
  18. Sayed S, Cherniak W, Lawler M, Tan SY, El Sadr W, Wolf N, et al.
    Lancet, 2018 05 12;391(10133):1939-1952.
    PMID: 29550027 DOI: 10.1016/S0140-6736(18)30459-8
    Insufficient awareness of the centrality of pathology and laboratory medicine (PALM) to a functioning health-care system at policy and governmental level, with the resultant inadequate investment, has meant that efforts to enhance PALM in low-income and middle-income countries have been local, fragmented, and mostly unsustainable. Responding to the four major barriers in PALM service delivery that were identified in the first paper of this Series (workforce, infrastructure, education and training, and quality assurance), this second paper identifies potential solutions that can be applied in low-income and middle-income countries (LMICs). Increasing and retaining a quality PALM workforce requires access to mentorship and continuing professional development, task sharing, and the development of short-term visitor programmes. Opportunities to enhance the training of pathologists and allied PALM personnel by increasing and improving education provision must be explored and implemented. PALM infrastructure must be strengthened by addressing supply chain barriers, and ensuring laboratory information systems are in place. New technologies, including telepathology and point-of-care testing, can have a substantial role in PALM service delivery, if used appropriately. We emphasise the crucial importance of maintaining PALM quality and posit that all laboratories in LMICs should participate in quality assurance and accreditation programmes. A potential role for public-private partnerships in filling PALM services gaps should also be investigated. Finally, to deliver these solutions and ensure equitable access to essential services in LMICs, we propose a PALM package focused on these countries, integrated within a nationally tiered laboratory system, as part of an overarching national laboratory strategic plan.
    Matched MeSH terms: Point-of-Care Systems
  19. Sithambaram S, Hilmi I, Goh KL
    PLoS One, 2015;10(7):e0131616.
    PMID: 26158845 DOI: 10.1371/journal.pone.0131616
    M2 pyruvate kinase (M2PK) is an oncoprotein secreted by colorectal cancers in stools. This the first report on the accuracy of a rapid stool test in the detection of colorectal cancer (CRC).
    Matched MeSH terms: Point-of-Care Systems
  20. Tan AF, Thota P, Sakam SSB, Lew YL, Rajahram GS, William T, et al.
    Sci Rep, 2023 Mar 23;13(1):4760.
    PMID: 36959462 DOI: 10.1038/s41598-023-31839-7
    Plasmodium knowlesi is the major cause of zoonotic malaria in Southeast Asia. Rapid and accurate diagnosis enables effective clinical management. A novel malaria diagnostic tool, Gazelle (Hemex Health, USA) detects haemozoin, a by-product of haem metabolism found in all Plasmodium infections. A pilot phase refined the Gazelle haemozoin identification algorithm, with the algorithm then tested against reference PCR in a larger cohort of patients with P. knowlesi mono-infections and febrile malaria-negative controls. Limit-of-detection analysis was conducted on a subset of P. knowlesi samples serially diluted with non-infected whole blood. The pilot phase of 40 P. knowlesi samples demonstrated 92.5% test sensitivity. P. knowlesi-infected patients (n = 203) and febrile controls (n = 44) were subsequently enrolled. Sensitivity and specificity of the Gazelle against reference PCR were 94.6% (95% CI 90.5-97.3%) and 100% (95% CI 92.0-100%) respectively. Positive and negative predictive values were 100% and 98.8%, respectively. In those tested before antimalarial treatment (n = 143), test sensitivity was 96.5% (95% CI 92.0-98.9%). Sensitivity for samples with ≤ 200 parasites/µL (n = 26) was 84.6% (95% CI 65.1-95.6%), with the lowest parasitaemia detected at 18/µL. Limit-of-detection (n = 20) was 33 parasites/µL (95% CI 16-65%). The Gazelle device has the potential for rapid, sensitive detection of P. knowlesi infections in endemic areas.
    Matched MeSH terms: Point-of-Care Systems
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links