Displaying publications 1 - 20 of 71 in total

Abstract:
Sort:
  1. Zainol Abidin MN, Goh PS, Said N, Ismail AF, Othman MHD, Hasbullah H, et al.
    ACS Appl Mater Interfaces, 2020 Jul 22;12(29):33276-33287.
    PMID: 32589391 DOI: 10.1021/acsami.0c08947
    The development of wearable artificial kidney demands an efficient dialysate recovery, which relies upon the adsorption process. This study proposes a solution to solve the problem of competitive adsorption between the uremic toxins by employing two adsorptive components in a membrane separation process. Dual-layer hollow fiber (DLHF) membranes, which are composed of a polysulfone (PSf)/activated carbon (AC) inner layer and a PSf/poly(methyl methacrylate) (PMMA) outer layer, were prepared for co-adsorptive removal of creatinine and urea from aqueous solution. The DLHF membranes were characterized in terms of morphological, physicochemical, water transport, and creatinine adsorption properties. The membrane was then subjected to an ultrafiltration adsorption study for performance evaluation. The incorporation of AC in membrane, as confirmed by microscopic and surface analyses, has improved the pure water flux up to 25.2 L/(m2 h). A membrane with optimum AC loading (9 wt %) demonstrated the highest maximum creatinine adsorption capacity (86.2 mg/g) based on the Langmuir adsorption isotherm model. In the ultrafiltration adsorption experiment, the membrane removed creatinine and urea with a combined average percent removal of 29.3%. Moreover, the membrane exhibited creatinine and urea uptake recoveries of 98.8 and 81.2%, respectively. The combined action of PMMA and AC in the PSf DLHF membrane has made the adsorption of multiple uremic toxins possible during dialysate recovery.
    Matched MeSH terms: Polymethyl Methacrylate/chemistry*
  2. Teh, G.B., Wong, Y.C., Tilley, R.D.
    ASM Science Journal, 2014;8(1):21-28.
    MyJurnal
    Co(II)-Ti(IV)-substituted magnetoplumbite-type (M-type) barium ferrite nanoparticles were synthesized via the sol-gel technique employing ethylene glycol as the gel precursor. Structural and magnetic properties were characterised via X-ray diffraction (XRD), high resolution transmission electron microscopy and superconducting quantum interference device magnetometry. The particle sizes of the M-type BaCoXTiXFe12-2XO19 (0.2 ≤  ≤ 1.0) were found to be 900 Å – 1500 Å. The XRD results confirmed that the Co(II)-Ti(IV) substituted ferrites in the range of 0.2 ≤  ≤ 1.0 substitution had the M-type ferrite as the dominant phase. The hysteresis loss per-cycle decreased with increasing Co(II)-Ti(IV) substitution in M-type ferrites which showed reduced values in coercivity and remnant magnetisation with moderate effect on the saturation magnetisation.
    Matched MeSH terms: Polymethyl Methacrylate
  3. Osman, Z., Othman, L., Md Isa, K.B., Ahmad, A., Kamarulzaman, N.
    ASM Science Journal, 2010;4(1):55-61.
    MyJurnal
    In this study polymer electrolytes composed of poly(methyl methacrylate) (PMMA) as a host polymer and ethylene carbonate (EC) as a plasticizer complexed with different lithium salts, i.e. lithium tetrafluoroborate (LiBF4) and lithium triflate (LiCF3SO3) were prepared by the solution casting technique. The conductivities of the films were characterized by impedance spectroscopy. At room temperature, the highest conductivities were 4.07 × 10–7S cm–1 and 3.40 × 10–5 S cm–1 achieved, respectively from the films containing 30 wt% LiBF4 in the PMMA-EC-LiBF4 system and 35 wt% LiCF3SO3 in the PMMA-EC-LiCF3SO3 system. The conductivity-temperature dependence of the films seemed to obey the Arrhenius equation in which the ion transport in these materials was thermally assisted. Scanning electron microscopy analysis showed that the surface of PMMA-EC-LiCF3SO3 film was smooth and homogeneous, hence lithium ions could traverse through the PMMA-EC-LiCF3SO3 film more easily compared to the PMMA-EC-LiBF4 film. X-Ray diffraction studies revealed that complexation had occurred and the complexes formed were amorphous.
    Matched MeSH terms: Polymethyl Methacrylate
  4. Hamzah, I.H., Sidek, O., Abd Manaf, A.
    ASM Science Journal, 2010;4(2):142-148.
    MyJurnal
    A preliminary study was carried out to fabricate a three electrode system based on electrochemical sensoring. The cyclic voltammetry (CV) technique was chosen to select the type of metal suitable for evaporation and to compare the results produced from the fabricated gold electrode with the conventional macro-electrode system. The methodology and apparatus used involved low cost apparatus and methodology such as soft lithography, wet-etching, thermal evaporation, direct current sputtering, polymethylmethacrylate moulding and polydimethylsiloxane coating. The experiment was conducted at a fixed scan rate of 100 mV/s by using 0.01 M K3Fe(CN)6 in 0.1M KCl and well known method using Randles-Sevcik equation, peak current ratio and voltage separation was used to analyze the characterization on the fabricated sensors. Electrodes of 6.5 mm2 and 0.26 mm2 were fabricated to prove the adsorption effect of the reactant and the influence of the electrode area on the value of the peak current. CV analysis proved that the fabricated sensor was reliable for a range of 24 h at 25ºC room temperature.
    Matched MeSH terms: Polymethyl Methacrylate
  5. Kassim, S., Tahrin, R.A.A., Rusdi, N.F., Harun, N.A.
    ASM Science Journal, 2018;11(101):86-95.
    MyJurnal
    A feasible production of poly (methyl methacrylate)@alloy (gold-silver) core shell has
    been presented as candidate in enhanced detection of surface enhanced Raman scattering
    (SERS). Free emulsifier- emulsion synthesised PMMA sphere with average size of 419 nm in
    diameter were used as core material for incorporation of alloy nanoparticles (6 nm) resulting
    a core-shell structure. The fabrication of PMMA@alloy SERS substrate was successfully
    done via self-assembly thus the produced SERS substrate that comprise of unique optical
    properties combination arising from periodic core arrangement and plasmonic activity of
    alloy nanoparticles. Alloy is bimetallic nanoparticles in which the combination of silver
    (Ag) and gold (Au) present an absolutely improved light resistance as compared to single
    metal alone with great surface plasmon resonance. Morphology and elemental analysis was
    performed through scanning electron microscope (SEM) and the analysis showing species of
    both Au and Ag in single alloy nanoparticles. The alloy nanoparticles were also observed to
    homogenously coating the PMMA sphere. Surface plasmon resonance activity was maximum
    at 476 nm obtained from UV-Visible spectroscopy. High surface production was observed
    to have periodically arranged PMMA@alloy core -shell and potentially to be used as SERS
    substrate.
    Matched MeSH terms: Polymethyl Methacrylate
  6. Abdullah, M.A.A., Mamat, M., Rusli, S.A., Kassim, A.A.
    ASM Science Journal, 2018;11(101):96-104.
    MyJurnal
    Considering its excellent thermal stability, alkyl phosphonium surfactant: triisobutyl(methyl)phosphonium
    (TIBMP) was used in this research as an intercalant for surface
    modification of Na+-MMT via ion exchange process forming organomontmorillonite
    (OMMT). The OMMT was then used as filler in poly(methyl methacrylate) (PMMA) via
    melt intercalation technique. OMMT decomposed at a higher temperature than commercial
    alkyammonium modified MMT. Exfoliated and intercalated types of nanocomposites
    are obtained from PMMA/OMMTs at low and high content of OMMT loading, depending
    on the space of those clay platelets had to disperse in PMMA. The ability of OMMT to
    carry a certain load applied in PMMA matrix enhances the tensile strength in all composites.
    TIBMP are compatible with PMMA matrix, and significantly improves the tensile
    properties of PMMA composites.
    Matched MeSH terms: Polymethyl Methacrylate
  7. Swaminathan, D., Moran, John, Addy, Martin
    Ann Dent, 1996;3(1):-.
    MyJurnal
    Side effects such as abrasion of the dental hard tissue have been frequently observed following the extensive use of mechanical cleansing. As promising antiseptics like chlorhexidine produces extrinsic dental staining on long term usage, there has been increasing interest and research generated towards chemically based stain removing agents. This invitro studyexamined whether some commercial oral hygiene products could inhibit chlorhexidine derived stain independent of any mechanical cleansing action. Perspex blocks were soaked in triplicate in chlorhexidine solution for 2 minutesand stain inhibition by these products was determined by further soaking the blocks in productl water slurries for 2 minutes and finally in tea solution for I hourly periods. The optical density (OD) of each specimen was determined at each hourly interval by spectrophotometry at 395 nm and the mean values obtained. At the end of the study, most of the products inhibited stain compared to water control and there was a variation in the stain inhibitingefficacyof the products. It is thus concluded that oral hygiene products like dentifricesand mouthrinses can inhibit chlorhexidine derived extrinsic dental stain to a variable degree through a chemical action by contained ingredients.
    Matched MeSH terms: Polymethyl Methacrylate
  8. Zamri Radzi, Noor Hayaty Abu Kasim, Yahya, N.A., Gan, S.N., Daud, N.M., Saffai, L., et al.
    Ann Dent, 2007;14(1):46-51.
    MyJurnal
    The impact strength of a newly developed experimental polyurethane-based polymer which is derived from palm oil (Experimental PU) was compared with denture polymers; heat-cured and self cured polymethyl methacrylate (PMMA) and ® Eclipse , light-activated urethane dimethacrylate prosthetic resin system. Ten specimens were ® prepared using heat-cured PMMA (Meliodent Heat Cure, Heraeus Kulzer, Germany), self cured PMMA ® (Meliodent Rapid Repair, Heraeus Kulzer, ® Germany), Eclipse baseplate resin (Dentsply, USA) and Experimental PU material. Specimens were prepared following manu- facturer’s instructions except for the Experimental PU material where it was prepared in bulk and sectioned to the desired dimension, 64 x 6 x 4 mm. A ‘V’ notch of approximately 0.8mm in depth was machine cut across the 6mm width. Prior to the Charpy type impact test, specimens were soaked in a water bath for 50 hours at 37ºC. ® Eclipse baseplate resin showed the highest 2 impact strength (2.73 kJ/m ±0.54) followed by ® 2 Meliodent Rapid Repair (2.50kJ/m ±0.65), ® 2 Meliodent Heat Cure (1.96kJ/m ±0.42) and 2 Experimental PU (1.04kJ/m ±0.29). One-way ANOVA showed significant interaction between materials (p
    Matched MeSH terms: Polymethyl Methacrylate
  9. Ling BC
    PMID: 11709981
    Standard prosthodontic procedures require five visits to construct a set of complete maxillary and mandibular dentures. Various attempts have been made to reduce these procedures to four or three appointments. However, most of these techniques require the use of visible light polymerized resin as the final denture base materials. Visible light-cured resin materials have inferior physical properties and biocompatibility problems as compared with heat cured polymethylmethacrylate. This paper describes a system of complete denture construction which requires three clinical appointments instead of the usual five visits. This system is made possible by using the VLC base/tray material as the preliminary impression material as well as the application of a new biometric wax occlusion rim. It retains the use of polymethylmethacrylate as the denture base material. This system also utilizes all the procedures used in the conventional five appointment system of complete denture construction.
    Matched MeSH terms: Polymethyl Methacrylate/chemistry
  10. Abd Samad H, Jaafar M, Othman R, Kawashita M, Abdul Razak NH
    Biomed Mater Eng, 2011;21(4):247-58.
    PMID: 22182792 DOI: 10.3233/BME-2011-0673
    In present study, a new composition of glass-ceramic was synthesized based on the Na2O-CaO-SiO2-P2O5 glass system. Heat treatment of glass powder was carried out in 2 stages: 600 °C as the nucleation temperature and different temperature on crystallization at 850, 950 and 1000 °C. The glass-ceramic heat-treated at 950 °C was selected as bioactive filler in commercial PMMA bone cement; (PALACOS® LV) due to its ability to form 2 high crystallization phases in comparison with 850 and 1000 °C. The results of this newly glass-ceramic filled PMMA bone cement at 0-16 wt% of filler loading were compared with those of hydroxyapatite (HA). The effect of different filler loading on the setting properties was evaluated. The peak temperature during the polymerization of bone cement decreased when the liquid to powder (L/P) ratio was reduced. The setting time, however, did not show any trend when filler loading was increased. In contrast, dough time was observed to decrease with increased filler loading. Apatite morphology was observed on the surface of the glass-ceramic and selected cement after bioactivity test.
    Matched MeSH terms: Polymethyl Methacrylate/chemistry*
  11. Bean LS, Heng LY, Yamin BM, Ahmad M
    Bioelectrochemistry, 2005 Feb;65(2):157-62.
    PMID: 15713567
    A single-step fabrication of a glucose biosensor with simultaneous immobilization of both ferrocene mediator and glucose oxidase in a photocurable methacrylic film consisting of poly(methyl methacrylate-co-2-hydroxylethyl methacrylate) was reported. The entrapped ferrocene showed reversible redox behaviour in the photocured film and no significant leaching of both entrapped ferrocene and enzyme glucose oxidase was observed because of the low water absorption properties of the co-polymer films. From electrochemical studies, ferrocene entrapped in the co-polymer film demonstrated slow diffusion properties. A linear glucose response range of 2-11 mM was obtained at low applied potential of +0.25 V. The glucose biosensor fabricated by this photocuring method yielded sensor reproducibility and repeatability with relative standard deviation of <10% and long-term stability of up to 14 days. The main advantage of the use of photocurable procedure is that biosensor membrane fabrication can be performed in a single step without any lengthy chemical immobilization of enzyme.
    Matched MeSH terms: Polymethyl Methacrylate
  12. Jacobs E, Saralidze K, Roth AK, de Jong JJ, van den Bergh JP, Lataster A, et al.
    Biomaterials, 2016 Mar;82:60-70.
    PMID: 26751820 DOI: 10.1016/j.biomaterials.2015.12.024
    There are a number of drawbacks to incorporating large concentrations of barium sulfate (BaSO4) as the radiopacifier in PMMA-based bone cements for percutaneous vertebroplasty. These include adverse effects on injectability, viscosity profile, setting time, mechanical properties of the cement and bone resorption. We have synthesized a novel cement that is designed to address some of these drawbacks. Its powder includes PMMA microspheres in which gold particles are embedded and its monomer is the same as that used in commercial cements for vertebroplasty. In comparison to one such commercial cement brand, VertaPlex™, the new cement has longer doughing time, longer injection time, higher compressive strength, higher compressive modulus, and is superior in terms of cytotoxicity. For augmentation of fractured fresh-frozen cadaveric vertebral bodies (T6-L5) using simulated vertebroplasty, results for compressive strength and compressive stiffness of the construct and the percentage of the volume of the vertebral body filled by the cement were comparable for the two cements although the radiopacity of the new cement was significantly lower than that for VertaPlex™. The present results indicate that the new cement warrants further study.
    Matched MeSH terms: Polymethyl Methacrylate/chemistry*
  13. Kohli S, Bhatia S
    Biomed J, 2015 May-Jun;38(3):244-9.
    PMID: 25355393 DOI: 10.4103/2319-4170.143519
    Proper function, esthetics, and cost are the prime factors to be considered while selecting bridge veneering materials. The purpose of the study is to evaluate color durability of acrylic veneer materials after immersion in common beverages at different time intervals.
    Matched MeSH terms: Polymethyl Methacrylate
  14. Rosli NA, Ahmad I, Anuar FH, Abdullah I
    Carbohydr Polym, 2019 Jun 01;213:50-58.
    PMID: 30879689 DOI: 10.1016/j.carbpol.2019.02.074
    In this study, modified agave cellulose fibre combined by graft copolymerisation with methylmethacrylate was tested as a potential reinforcement for polylactic acid (PLA)-natural rubber/liquid natural rubber blends. Mechanical, morphological, thermal, wetting, and biodegradation characterisations were performed to assess the influence of cellulose-graft-polymethylmethacrylate (cell-g-PMMA) content on the properties of biocomposites. The addition of cell-g-PMMA improved the mechanical properties of the composites because of the chemical interaction between PLA and PMMA. Thermal stability decreased slightly upon cell-g-PMMA addition because of the low thermal stability of PMMA. A soil burial test revealed that the degradation of composites decreased with an increase in the cell-g-PMMA content. However, the weight loss after burial, which directly affected the water absorption capacity, was still higher for the cell-g-PMMA composites than for the polymer alone.
    Matched MeSH terms: Polymethyl Methacrylate
  15. Shah V, Chaubal TV, Bapat RA, Shetty D
    Contact Derm., 2017 Dec;77(6):407-408.
    PMID: 29164691 DOI: 10.1111/cod.12779
    Matched MeSH terms: Polymethyl Methacrylate/adverse effects*
  16. Cahyanto A, Martins MVS, Bianchi O, Sudhakaran DP, Sililkas N, Echeverrigaray SG, et al.
    Dent Mater, 2023 Sep;39(9):763-769.
    PMID: 37400298 DOI: 10.1016/j.dental.2023.06.009
    OBJECTIVES: to characterize the effects of graphene oxide (GO) on polymethyl methacrylate's (PMMA) reliability and lifetime. The hypothesis tested was that GO would increase both Weibull parameters and decreased strength degradation over time.

    METHODS: PMMA disks containing GO (0.01, 0.05, 0.1, or 0.5 wt%) were subjected to a biaxial flexural test to determine the Weibull parameters (m: modulus of Weibull; σ0: characteristic strength; n = 30 at 1 MPa/s) and slow crack growth (SCG) parameters (n: subcritical crack growth susceptibility coefficient, σf0: scaling parameter; n = 10 at 10-2, 10-1, 101, 100 and 102 MPa/s). Strength-probability-time (SPT) diagrams were plotted by merging SCG and Weibull parameters.

    RESULTS: There was no significant difference in the m value of all materials. However, 0.5 GO presented the lowest σ0, whereas all other groups were similar. The lowest n value obtained for all GO-modified PMMA groups (27.4 for 0.05 GO) was higher than the Control (15.6). The strength degradation predicted after 15 years for Control was 12%, followed by 0.01 GO (7%), 0.05 GO (9%), 0.1 GO (5%), and 0.5 GO (1%).

    SIGNIFICANCE: The hypothesis was partially accepted as GO increased PMMA's fatigue resistance and lifetime but did not significantly improve its Weibull parameters. GO added to PMMA did not significantly affect the initial strength and reliability but significantly increased PMMA's predicted lifetime. All the GO-containing groups presented higher resistance to fracture at all times analyzed compared with the Control, with the best overall results observed for 0.1 GO.

    Matched MeSH terms: Polymethyl Methacrylate*
  17. Husna Abdul Rahman, Haliza M. Haron, Naimah Mat Isa, Hasnida Saad
    ESTEEM Academic Journal, 2020;15(2):24-34.
    MyJurnal
    PMMA polymer microfiber doped Multi Walled Carbon Nanotubes (MWCNTs) was reported for alcohol sensing application. The sensitivity of the sensor is increasing relatively with the increment of the alcohol concentration which affects the transmission output power. However, the challenges are on choosing the right material and the simplicity on the fabrication of microfiber sensor for an improvement of the sensitivity of the sensor. A PMMA polymer microfiber doped MWCNTs was introduced for an application of alcohol detection system. Direct drawing technique was used to form a uniform waist size of microfiber sensor with 6µm diameter and 5mm length respectively. The performance of the fabricated sensor was tested with two types of alcohol, namely ethanol and 2-propanol at concentrations varying from 2% to 8% with 2% intervals. The performance which includes sensitivity, linearity and resolution were studied and analysed for the undoped PMMA and PMMA doped MWCNTs-doped polymer microfiber. The PMMA doped MWCNTs sensor which exhibited higher sensitivity for ethanol sensing with 83.23dBm/% with a linearity of 99.96% and a sensitivity of 73.75dBm/% with linearity 99.82% for 2- propanol sensing. The resolution has improved significantly by 0.0004% and 0.0007% respectively. In conclusion, PMMA doped MWCNTs was able to increase the sensitivity as well as the reproducibility of the microfiber sensor for the alcohol detection system.
    Matched MeSH terms: Polymethyl Methacrylate
  18. Omar MM, Wan Ibrahim WA, Elbashir AA
    Food Chem, 2014 Sep 1;158:302-9.
    PMID: 24731346 DOI: 10.1016/j.foodchem.2014.02.045
    A sol-gel hybrid sorbent, methyltrimethoxysilane-tetraethoxysilane (MTMOS-TEOS) was successfully used as new dispersive solid phase extraction (dSPE) sorbent material in the determination of acrylamide in several Sudanese foods and analysis using GC-MS. Several important dSPE parameters were optimised. Under the optimised conditions, excellent linearity (r(2)>0.9998) was achieved using matrix matched standard calibration in the concentration range 50-1000 μg kg(-1). The limits of detection (LOD) and limit of quantification ranged from 9.1 to 12.8 μg/kg and 27.8-38.9 μg/kg, respectively. The precision (RSD%) of the method was ⩽6.6% and recoveries of acrylamide obtained were in the range of 88-103%, (n=3). The LOD obtained is comparable with the LODs of primary secondary amine dSPE. The proposed MTMOS-TEOS dSPE method is direct and safe for acrylamide analysis, showed reliable method validation performances and good cleanup effects. It was successfully applied to the analysis of acrylamide in real food samples.
    Matched MeSH terms: Polymethyl Methacrylate
  19. Hairenanorashikin Sharip, Rafidah Supar
    MyJurnal
    This experimental study investigated the significant different in image quality and dose between different
    automatic exposure of exposure parameter (AOP) mode in full field digital mammography (FFDM) system.
    CIRS012A and PMMA breast phantom (4cm, 5cm and 6 cm thickness) were used as subject using
    Senographe Essential FFDM system. TLD chip was used as dose measurement tool. Exposures were taken
    in cranio-caudal projection. 2 radiographers with more than 10 years of working experience in performing
    mammography scored the image independently. Kappa finds a good agreement between raters (kappa
    value=0.9, p0.05). DOSE mode is the preferred selection in optimizing between dose and image quality.
    Matched MeSH terms: Polymethyl Methacrylate
  20. May LW, John J, Seong LG, Abidin ZZ, Ibrahim N, Danaee M, et al.
    J Indian Prosthodont Soc, 2021 5 4;21(2):198-203.
    PMID: 33938871 DOI: 10.4103/jips.jips_41_21
    Aim: To investigate the effect of different cooling methods on denture base adaptation of rapid heat-cured acrylic resin using 3D superimposition technique.

    Setting and Design: In vitro - Comparative study.

    Materials and Methods: Denture base adaptation of two different rapid heat-cured polymethyl methacrylate acrylic resins using five different cooling methods were compared. Forty maxillary edentulous stone cast were prepared to produce the denture bases with standardized thickness. The specimens were divided into five groups (n = 8) according to type of materials and cooling methods. The master stone cast and all forty denture bases were scanned with 3Shape E1 laboratory scanner. The scanned images of each of the denture bases were superimposed over the scanned image of the master cast using Materialize 3-matic software. Three dimensional differences between the two surfaces were calculated and color surface maps were generated for visual qualitative assessment.

    Statistical Analysis Used: Generalized Linear Model Test, Bonferroni Post Hoc Analysis.

    Results: All bench-cooled specimens showed wide green-colored area in the overall palatal surface, while the rapid cooled specimens presented with increased red color areas especially at the palate and post dam area. Generalized Linear Model test followed by Bonferroni post hoc analysis showed significant difference in the root mean square values among the specimen groups.

    Conclusion: Samples that were bench cooled, demonstrated better overall accuracy compared to the rapid cooling groups. Regardless of need for shorter denture processing time, bench cooling of rapid heat-cured PMMA is essential for acceptable denture base adaptation.

    Matched MeSH terms: Polymethyl Methacrylate
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links