Displaying publications 1 - 20 of 101 in total

Abstract:
Sort:
  1. Abd Razak NA, Abu Osman NA, Gholizadeh H, Ali S
    Biomed Eng Online, 2014;13:134.
    PMID: 25208636 DOI: 10.1186/1475-925X-13-134
    Understanding of kinematics force applied at the elbow is important in many fields, including biomechanics, biomedical engineering and rehabilitation. This paper provides a comparison of a mathematical model of elbow joint using three different types of prosthetics for transhumeral user, and characterizes the forces required to overcome the passive mechanical of the prosthetics at the residual limb.
    Matched MeSH terms: Prostheses and Implants*
  2. Abdul Aziz, A, Ahmad, S.F., Muslim, Y.R
    Ann Dent, 2006;13(1):34-38.
    MyJurnal
    This clinical case report details the clinical sequence of a 78-year-old male receiving prosthetic rehabilitation using an implant-supported screwretained fixed partial denture. Despite the limitations imposed, the aesthetic and functional demands of the patient were fulfilled by this prosthetic rehabilitation. The importance of detailed prosthetic planning and evaluation prior to implant surgery is essential, therefore ideally, it should be done by the same operator or a team of operators working together. Problems can arise when the construction of the prosthesis is performed by other people who are not involved in the planning stage.
    Matched MeSH terms: Prostheses and Implants
  3. Adli Azam MR, Raja Amin RM
    Malays J Med Sci, 2015 Jan-Feb;22(1):70-3.
    PMID: 25892952 MyJurnal
    Malignant chest wall tumour is rare. The presentation is usually aggressive that requires extensive resection to prevent recurrence. However, the extensive resection is to the expense of causing defect on the chest wall and hence, respiratory mechanics. Two cases of chest wall tumour are discussed including the surgical approach of radical tumour resection which was combined with placement of titanium mesh and Tranverse Rectus Abdominis Myocutaneus (TRAM) flap to cover the defect and preserve respiratory mechanical functions. The morbidity of using titanium mesh demonstrated in the case series were infection and injury to surrounding tissue due to its rigidity and large size which required its removal. However the formation of 'pseudopleura' made the thoracic cage return back as closed cavity even after the removal of the titanium mesh and allow normal respiratory functions.
    Matched MeSH terms: Prostheses and Implants
  4. Akma Kamaludin NA, Ferdaus Kamudin NA, Abdullah S, Sapuan J
    Chin J Traumatol, 2019 Feb;22(1):59-62.
    PMID: 30745113 DOI: 10.1016/j.cjtee.2018.04.007
    Simultaneous ipsilateral fractures involving radial head and distal end of radius are uncommon. We present our thoughts on which fracture should be addressed first. A 68-year-old lady sustained an ipsilateral fracture of the right radial head and distal end of radius following a fall. Clinically her right elbow was posteriorly dislocated and right wrist was deformed. Plain radiographs showed an intraarticular fracture of the distal end of radius and a comminution radial head fracture with a proximally migrated radius. Magnetic resonance imaging (MRI) showed no significant ligament injuries. We addressed her distal radius first with an anatomical locking plate followed by her radial head with a radial head replacement. Our rationale to treat the distal end radius: first was to obtain a correct alignment of Lister's tubercle and correct the distal radius height. Lister's tubercle was used to guide for the correct rotation of the radial head prosthesis. Correcting the distal end fracture radial height helped us with length selection of the radial head prosthesis and address the proximally migrated radial shaft and neck. Postoperative radiographs showed an acceptable reduction. The Cooney score was 75 at 3 months postoperatively, which was equivalent to a fair functional outcome.
    Matched MeSH terms: Prostheses and Implants
  5. Al-Fakih E, Abu Osman NA, Mahamd Adikan FR
    Sensors (Basel), 2012 Sep 25;12(10):12890-926.
    PMID: 23201977 DOI: 10.3390/s121012890
    In recent years, fiber Bragg gratings (FBGs) are becoming increasingly attractive for sensing applications in biomechanics and rehabilitation engineering due to their advantageous properties like small size, light weight, biocompatibility, chemical inertness, multiplexing capability and immunity to electromagnetic interference (EMI). They also offer a high-performance alternative to conventional technologies, either for measuring a variety of physical parameters or for performing high-sensitivity biochemical analysis. FBG-based sensors demonstrated their feasibility for specific sensing applications in aeronautic, automotive, civil engineering structure monitoring and undersea oil exploration; however, their use in the field of biomechanics and rehabilitation applications is very recent and its practicality for full-scale implementation has not yet been fully established. They could be used for detecting strain in bones, pressure mapping in orthopaedic joints, stresses in intervertebral discs, chest wall deformation, pressure distribution in Human Machine Interfaces (HMIs), forces induced by tendons and ligaments, angles between body segments during gait, and many others in dental biomechanics. This article aims to provide a comprehensive overview of all the possible applications of FBG sensing technology in biomechanics and rehabilitation and the status of ongoing researches up-to-date all over the world, demonstrating the FBG advances over other existing technologies.
    Matched MeSH terms: Prostheses and Implants*
  6. Al-Quraishi MS, Ishak AJ, Ahmad SA, Hasan MK, Al-Qurishi M, Ghapanchizadeh H, et al.
    Med Biol Eng Comput, 2017 May;55(5):747-758.
    PMID: 27484411 DOI: 10.1007/s11517-016-1551-4
    Electromyography (EMG)-based control is the core of prostheses, orthoses, and other rehabilitation devices in recent research. Nonetheless, EMG is difficult to use as a control signal given the complex nature of the signal. To overcome this problem, the researchers employed a pattern recognition technique. EMG pattern recognition mainly involves four stages: signal detection, preprocessing feature extraction, dimensionality reduction, and classification. In particular, the success of any pattern recognition technique depends on the feature extraction stage. In this study, a modified time-domain features set and logarithmic transferred time-domain features (LTD) were evaluated and compared with other traditional time-domain features set (TTD). Three classifiers were employed to assess the two feature sets, namely linear discriminant analysis (LDA), k nearest neighborhood, and Naïve Bayes. Results indicated the superiority of the new time-domain feature set LTD, on conventional time-domain features TTD with the average classification accuracy of 97.23 %. In addition, the LDA classifier outperformed the other two classifiers considered in this study.
    Matched MeSH terms: Prostheses and Implants
  7. Alwi M, Kang LM, Samion H, Latiff HA, Kandavel G, Zambahari R
    Am J Cardiol, 1997 May 15;79(10):1430-2.
    PMID: 9165178 DOI: 10.1016/s0002-9149(97)00160-4
    Two hundred eleven patients with small- to moderate-sized native patent ductus arteriosus underwent closure using Gianturco coils, employing the transvenous multiple catheter approach. Short-term results showed a high rate of complete occlusion and a potential long-term complication of mild left pulmonary artery stenosis in a small number of patients.
    Matched MeSH terms: Prostheses and Implants*
  8. Amjad M, Badshah S, Rafique AF, Adil Khattak M, Khan RU, Abdullah Harasani WI
    Materials (Basel), 2020 May 16;13(10).
    PMID: 32429420 DOI: 10.3390/ma13102299
    Implants are widely used in the human body for the replacement of affected bones. Fatigue failure is one of the serious concerns for implants. Therefore, understanding of the underlying mechanism leading to fatigue failure is important for the longevity of biomaterial implants. In this paper, the fracture toughness and fatigue crack growth of titanium alloy biomaterial Ti-27Nb has been experimentally investigated. The Ti-27Nb material is tested for fatigue crack growth in different environmental conditions representing the ambient and in vitro environments for 504 hours and 816 hours, respectively. Fractography of the tested specimen is conducted using Scanning Electron Microscope (SEM). The results of the fatigue crack growth propagation of the ambient and in vitro samples are similar in the Paris crack growth region. However, in the threshold region, the crack growth rate is higher for the Simulated Body Fluid (SBF) treated specimen. The fracture surface morphology of in vitro samples shows brittle fracture as compared to ambient specimens with significant plasticity and striations marks. It is proposed that a similar investigation may be conducted with specimens treated in SBF for prolonged periods to further ascertain the findings of this study.
    Matched MeSH terms: Prostheses and Implants
  9. Arifin N, Hasbollah HR, Hanafi MH, Ibrahim AH, Rahman WAWA, Aziz RC
    Malays J Med Sci, 2017 Oct;24(5):106-111.
    PMID: 29386978 MyJurnal DOI: 10.21315/mjms2017.24.5.12
    The incidence of lower limb amputation is high across the globe and continues to be a major threat to morbidity and mortality. Consequently, the provision of high quality and effective prosthetics services have been known as an essential component for a successful rehabilitation outcome. In Malaysia, amputation prevalence has been increasing in which several main components of service delivering aspects (such as service intervention, prosthetic personnel) should be anticipated to accommodate for the increasing demand. This article highlights the hurdles experienced in providing prosthetic services in Malaysia from multiple aspects such as financial burden to acquire the prosthesis and lack of expertise to produce quality prosthesis. This paramount issues consequently justify for the urgency to carry out national level survey on the current statistics of lower limb amputation and to ascertain the available workforce to provide a quality prosthetics services. Only with accurate and current information from the national survey, strategies and policies aimed at enhancing the outcome from prosthetics services can be achieved.
    Matched MeSH terms: Prostheses and Implants
  10. Asan NB, Hassan E, Shah JVSRM, Noreland D, Blokhuis TJ, Wadbro E, et al.
    Sensors (Basel), 2018 Aug 21;18(9).
    PMID: 30134629 DOI: 10.3390/s18092752
    In this paper, we investigate the use of fat tissue as a communication channel between in-body, implanted devices at R-band frequencies (1.7⁻2.6 GHz). The proposed fat channel is based on an anatomical model of the human body. We propose a novel probe that is optimized to efficiently radiate the R-band frequencies into the fat tissue. We use our probe to evaluate the path loss of the fat channel by studying the channel transmission coefficient over the R-band frequencies. We conduct extensive simulation studies and validate our results by experimentation on phantom and ex-vivo porcine tissue, with good agreement between simulations and experiments. We demonstrate a performance comparison between the fat channel and similar waveguide structures. Our characterization of the fat channel reveals propagation path loss of ∼0.7 dB and ∼1.9 dB per cm for phantom and ex-vivo porcine tissue, respectively. These results demonstrate that fat tissue can be used as a communication channel for high data rate intra-body networks.
    Matched MeSH terms: Prostheses and Implants*
  11. Asma A, Ubaidah MA, Hasan SS, Wan Fazlina WH, Lim BY, Saim L, et al.
    PMID: 24427576 DOI: 10.1007/s12070-013-0621-2
    Bone anchored hearing aid (Baha) implant is an option for patient with canal atresia, single sided deafness(SSD) and chronically discharging ears despite treatments. This retrospective study was conducted from 2001 to 2011 to evaluate the surgical outcome of Baha implant surgery. Thirty-three patients were identified during this study period. Their age at implantation ranged from 5 to 40 years. Of 33 patients, 29 (87.9 %) patients had bilateral microtia and canal atresia, 3 (9.1 %) patients had unilateral microtia and canal atresia and 1 (3.0 %) patients have SSD following labyrinthitis. One patient (3.2 %) had major complication which is lost of implant due to failure of osseointegration. Soft tissue reactions were seen 7 patients (21.1 %). Of these 7 patients, 4 patients required 3-4 procedures as day care operation for excision of the skin overgrowth surrounding the abutment. Recurrent antibiotic treatment was required in 3 patients (9.7 %). None of our patient had history of intraoperative or peri-operative complication following Baha surgery. The commonest complications are local infection and inflammation at the implant site. None of our patient had history of intraoperative or peri-operative complication following Baha implant surgery.
    Matched MeSH terms: Prostheses and Implants
  12. Asri RIM, Harun WSW, Samykano M, Lah NAC, Ghani SAC, Tarlochan F, et al.
    Mater Sci Eng C Mater Biol Appl, 2017 Aug 01;77:1261-1274.
    PMID: 28532004 DOI: 10.1016/j.msec.2017.04.102
    Corrosion prevention in biomaterials has become crucial particularly to overcome inflammation and allergic reactions caused by the biomaterials' implants towards the human body. When these metal implants contacted with fluidic environments such as bloodstream and tissue of the body, most of them became mutually highly antagonistic and subsequently promotes corrosion. Biocompatible implants are typically made up of metallic, ceramic, composite and polymers. The present paper specifically focuses on biocompatible metals which favorably used as implants such as 316L stainless steel, cobalt-chromium-molybdenum, pure titanium and titanium-based alloys. This article also takes a close look at the effect of corrosion towards the implant and human body and the mechanism to improve it. Due to this corrosion delinquent, several surface modification techniques have been used to improve the corrosion behavior of biocompatible metals such as deposition of the coating, development of passivation oxide layer and ion beam surface modification. Apart from that, surface texturing methods such as plasma spraying, chemical etching, blasting, electropolishing, and laser treatment which used to improve corrosion behavior are also discussed in detail. Introduction of surface modifications to biocompatible metals is considered as a "best solution" so far to enhanced corrosion resistance performance; besides achieving superior biocompatibility and promoting osseointegration of biocompatible metals and alloys.
    Matched MeSH terms: Prostheses and Implants
  13. Awang MN
    Int J Oral Maxillofac Surg, 1988 Apr;17(2):110-5.
    PMID: 3133418
    Oroantral fistula is an uncommon complication in oral surgery. Although smaller fistulas of less than 5 mm in diameter may close spontaneously, larger fistulas always require surgical closures. The literature review revealed various procedures for the closure of oroantral fistulas. These procedures may be subdivided into local flap, distant flap and grafting. Procedures involving local flaps are usually adequate to close minor to moderate size defects. Those procedures utilizing the buccal mucoperiosteal flap as the tissue closure include straight-advancement, rotated, sliding and transversal flap procedures; while those involving the palatal mucoperiosteum are straight advancement, rotational-advancement, hinged and island flap procedures. The combinations of various local flaps to strengthen the tissue closure are also being advocated. The advantages and the limitations of these procedures are discussed. Distant flaps and bone grafts are usually indicated in the closure of larger defects in view of their greater tissue bulks. Tongue flaps have superseded extra-oral flaps from extremities and forehead for aesthetic reasons and also in view of their similar tissue replacement. Various tongue flap procedures are described. At present, various alloplastic materials such as gold, tantalum and polymethylmethacrylate are infrequently reported in the closure of oroantral fistulas. However, in the light of successful reports over the use of biological materials, collagen and fibrin, in the closure of oroantral fistulas, there seems to be another simple alternative technique for treating oroantral fistulas.
    Matched MeSH terms: Prostheses and Implants
  14. Awang, R.A.R., Arief, E.M., Hassan, A.
    MyJurnal
    Since the establishment of implant in dentistry, the use of removable partial denture in replacing missing teeth apparently becomes less popular. The situation is made worse by the renowned limitations of removable partial denture. One of the obvious limitations of removable partial denture, especially in replacing missing anterior teeth is the unsightly view of metal used for retentive clasp. This case report describes the use of spring loaded plunger attachments as an alternative way to achieve retention and at the same time improving the aesthetic of the prosthesis.
    Matched MeSH terms: Prostheses and Implants
  15. Aytekin K, Esenyel CZ
    Malays Orthop J, 2018 Mar;12(1):45-47.
    PMID: 29725513 DOI: 10.5704/MOJ.1803.010
    Hip arthroplasty is an extremely satisfying treatment method for coxarthrosis which is in increasing use throughout the world. However, loosening of the prosthesis is a significant complication and to overcome this, ceramic liners are increasingly being selected. If the survival of ceramic surfaces is prolonged, there is a risk of fracture of the ceramic materials. New ceramic materials developed to overcome this problem are more resistant. The case presented here is of a patient in whom liner fracture developed following ceramic-ceramic hip arthroplasty. The ceramic femoral head was observed to have protruded into the defect created in the acetabular component. Acetabular revision was applied to the patient.
    Matched MeSH terms: Prostheses and Implants
  16. Azmi A, Latiff AZ, Johari A
    Med J Malaysia, 2004 Aug;59(3):418-21.
    PMID: 15727391
    We conducted a prospective study in order to audit our experience of repairing cranial defects using Methyl methacrylate. This included a total of 49 patients undergoing cranioplasty using methyl methacrylate, of which 45 were males and 4 females. The age of patients at the time of surgery ranged from 16 to 40 years old, with an average of 24 years. Malays were the majority (67%), followed by Chinese (23%) and Indian (10%). Cranial defects were mainly caused by motor vehicle accident (94%), while gunshot wounds, industrial accidents and tumours, each contribute 2%. Bone flaps were commonly removed during previous surgery related to traumatic subdural haemorrhage (33%), contusion (21%) and intracerebral haemorrhage (14%). The size of cranial defects ranged from 28 cm2 to 440 cm2, with an average of 201 cm2. Most had right sided (55%) and lateral defects [temporoparietal (52%) followed by temporal (16%), frontal (16%), frontotemporal (14%) and occipital (2%)]. Duration of surgery ranged from 70 to 275 minutes, with an average of 135 minutes. Nine of 12 patients (75%) with neurological disability had some improvement while 85% of symptomatic patients had symptoms improvement after cranioplasty. The infection rate in this series was 4%.
    Matched MeSH terms: Prostheses and Implants*
  17. Bakhsheshi-Rad HR, Ismail AF, Aziz M, Akbari M, Hadisi Z, Khoshnava SM, et al.
    Mater Sci Eng C Mater Biol Appl, 2020 Jun;111:110812.
    PMID: 32279830 DOI: 10.1016/j.msec.2020.110812
    Magnesium (Mg) alloys present great potential for the development of orthopedic implants, whereas, their high degradation rate and poor antibacterial performance have restricted orthopedic applications. In this work, PLLA/GO-AgNP (poly-L-lactic acid/graphene oxide- silver nanoparticle) with different concentration of GO-AgNPs were deposited on Mg alloy via electrospinning method for enhancement of corrosion resistance and antibacterial performance. The result revealed that incorporation of GO into PLLA fibrous considerably slowed down the degradation rate of Mg alloy substrate and reduced the H2 release rate from the substrate. Also, co-incorporation of GO and AgNPs into PLLA fibrous resulted in substantial escalate in compressive strength after immersion in simulated body fluid (SBF). Antibacterial activity test exhibited that Mg alloy and neat PLLA fibrous presented minimal inhibition area toward Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus). In contrast, using PLLA/GO-AgNPs fibrous improved antibacterial performance against both bacteria. Cytocompatibility results indicated that PLLA/GO-AgNPs fibrous with a low amount of GO-AgNPs enhanced cell proliferation and growth while high co-incorporation of GO-AgNPs showed a negative effect on cell proliferation. Taken together, PLLA/1GO-AgNPs fibrous coating shows suitable corrosion resistance, cytocompatibility, and antibacterial function for use in orthopedic applications.
    Matched MeSH terms: Prostheses and Implants*
  18. Balaji A, Jaganathan SK, Supriyanto E, Muhamad II, Khudzari AZ
    Int J Nanomedicine, 2015;10:5909-23.
    PMID: 26425089 DOI: 10.2147/IJN.S84307
    Developing multifaceted, biocompatible, artificial implants for tissue engineering is a growing field of research. In recent times, several works have been reported about the utilization of biomolecules in combination with synthetic materials to achieve this process. Accordingly, in this study, the ability of an extract obtained from Aloe vera, a commonly used medicinal plant in influencing the biocompatibility of artificial material, is scrutinized using metallocene polyethylene (mPE). The process of coating dense fibrous Aloe vera extract on the surface of mPE was carried out using microwaves. Then, several physicochemical and blood compatibility characterization experiments were performed to disclose the effects of corresponding surface modification. The Fourier transform infrared spectrum showed characteristic vibrations of several active constituents available in Aloe vera and exhibited peak shifts at far infrared regions due to aloe-based mineral deposition. Meanwhile, the contact angle analysis demonstrated a drastic increase in wettability of coated samples, which confirmed the presence of active components on glazed mPE surface. Moreover, the bio-mimic structure of Aloe vera fibers and the influence of microwaves in enhancing the coating characteristics were also meticulously displayed through scanning electron microscopy micrographs and Hirox 3D images. The existence of nanoscale roughness was interpreted through high-resolution profiles obtained from atomic force microscopy. And the extent of variations in irregularities was delineated by measuring average roughness. Aloe vera-induced enrichment in the hemocompatible properties of mPE was established by carrying out in vitro tests such as activated partial thromboplastin time, prothrombin time, platelet adhesion, and hemolysis assay. In conclusion, the Aloe vera-glazed mPE substrate was inferred to attain desirable properties required for multifaceted biomedical implants.
    Matched MeSH terms: Prostheses and Implants
  19. Bee SL, Bustami Y, Ul-Hamid A, Lim K, Abdul Hamid ZA
    J Mater Sci Mater Med, 2021 Aug 23;32(9):106.
    PMID: 34426879 DOI: 10.1007/s10856-021-06590-y
    Combination of bioactive material such as hydroxyapatite (HAp) with antibacterial agents would have great potential to be used as bone implant materials to avert possible bacterial infection that can lead to implant-associated diseases. The present study aimed to develop an antibacterial silver nanoparticle-decorated hydroxyapatite (HAp/AgNPs) nanocomposite using chemical reduction and thermal calcination approaches. In this work, natural HAp that was extracted from chicken bone wastes is used as support matrix for the deposition of silver nanoparticles (AgNPs) to produce HAp/AgNPs nanocomposite. XRD, FESEM-EDX, HRTEM, and XPS analyses confirmed that spherical AgNPs were successfully synthesized and deposited on the surface of HAp particles, and the amount of AgNPs adhered on the HAp surface increased with increasing AgNO3 concentration used. The synthesized HAp/AgNPs nanocomposites demonstrated strong antibacterial activity against Staphylococcus aureus bacteria, where the antibacterial efficiency is relied on the amount and size of deposited AgNPs. In addition, the in vitro bioactivity examination in Hank's balanced salt solution showed that more apatite were grown on the surface of HAp/AgNPs nanocomposite when AgNO3 concentration used >1 wt.%. Such nanocomposite with enhanced bioactivity and antibacterial properties emerged as a promising biomaterial to be applied for dentistry and orthopedic implantology.
    Matched MeSH terms: Prostheses and Implants
  20. Blackshaw H, Carding P, Jepson M, Mat Baki M, Ambler G, Schilder A, et al.
    BMJ Open, 2017 Sep 29;7(9):e016871.
    PMID: 28965097 DOI: 10.1136/bmjopen-2017-016871
    INTRODUCTION: A functioning voice is essential for normal human communication. A good voice requires two moving vocal folds; if one fold is paralysed (unilateral vocal fold paralysis (UVFP)) people suffer from a breathy, weak voice that tires easily and is unable to function normally. UVFP can also result in choking and breathlessness. Current treatment for adults with UVFP is speech therapy to stimulate recovery of vocal fold (VF) motion or function and/or injection of the paralysed VF with a material to move it into a more favourable position for the functioning VF to close against. When these therapies are unsuccessful, or only provide temporary relief, surgery is offered. Two available surgical techniques are: (1) surgical medialisation; placing an implant near the paralysed VF to move it to the middle (thyroplasty) and/or repositioning the cartilage (arytenoid adduction) or (2) restoring the nerve supply to the VF (laryngeal reinnervation). Currently there is limited evidence to determine which surgery should be offered to adults with UVFP.

    METHODS AND ANALYSIS: A feasibility study to test the practicality of running a multicentre, randomised clinical trial of surgery for UVFP, including: (1) a qualitative study to understand the recruitment process and how it operates in clinical centres and (2) a small randomised trial of 30 participants recruited at 3 UK sites comparing non-selective laryngeal reinnervation to type I thyroplasty. Participants will be followed up for 12 months. The primary outcome focuses on recruitment and retention, with secondary outcomes covering voice, swallowing and quality of life.

    ETHICS AND DISSEMINATION: Ethical approval was received from National Research Ethics Service-Committee Bromley (reference 11/LO/0583). In addition to dissemination of results through presentation and publication of peer-reviewed articles, results will be shared with key clinician and patient groups required to develop the future large-scale randomised controlled trial.

    TRIAL REGISTRATION NUMBER: ISRCTN90201732; 16 December 2015.

    Matched MeSH terms: Prostheses and Implants
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links