Displaying publications 1 - 20 of 101 in total

Abstract:
Sort:
  1. Singh, S., Choon, S.K., Tai, C.C.
    Malays Orthop J, 2008;2(2):34-36.
    MyJurnal
    We describe herein a modified technique for reconstruction of chronic rupture of the quadriceps tendon in a patient with bilateral total knee replacement and distal realignment of the patella. The surgery involved the application of a Dacron graft and the ‘double eights’ technique. The patient achieved satisfactory results after surgery and we believe that this technique of reconstruction offers advantages over other methods.
    Matched MeSH terms: Prostheses and Implants
  2. Mohanadas HP, Nair V, Doctor AA, Faudzi AAM, Tucker N, Ismail AF, et al.
    Ann Biomed Eng, 2023 Nov;51(11):2365-2383.
    PMID: 37466879 DOI: 10.1007/s10439-023-03322-x
    Additive Manufacturing is noted for ease of product customization and short production run cost-effectiveness. As our global population approaches 8 billion, additive manufacturing has a future in maintaining and improving average human life expectancy for the same reasons that it has advantaged general manufacturing. In recent years, additive manufacturing has been applied to tissue engineering, regenerative medicine, and drug delivery. Additive Manufacturing combined with tissue engineering and biocompatibility studies offers future opportunities for various complex cardiovascular implants and surgeries. This paper is a comprehensive overview of current technological advancements in additive manufacturing with potential for cardiovascular application. The current limitations and prospects of the technology for cardiovascular applications are explored and evaluated.
    Matched MeSH terms: Prostheses and Implants
  3. Tan, B. B., Shanmugam, R., Chua, Y. P., Hossain, G., Saw, A.
    Malays Orthop J, 2014;8(2):35-39.
    MyJurnal
    Taylor’s spatial frame (TSF) and Ilizarov external fixators (IEF) are two circular external fixator commonly used to address complex deformity and fractures. There is currently no data available comparing the biomechanical properties of these two external fixators. This study looks into the mechanical characteristics of each system. TSF rings with 6 oblique struts, 4 tube connectors, 4 threaded rods, and 6 threaded rods were compared to a standard IEF rings with 4 threaded rods. Compression and torsional loading was performed to the frame as well as construct with Polyvinylchloride tubes. TSF rings with 4 tube connectors had the highest stiffness (3288 N/mm) while TSF rings with 6 struts was the least stiff. The situation was reversed for torsion where TSF rings with 6 oblique struts had the highest torsional stiffness (82.01 Nm/Degree) and frame Ilizarov rings with 4 threaded rods the least. Standard TSF construct of two ring with 6 oblique struts have better torsional stiffness and lower axial stiffness compared to the standard IEF.
    Matched MeSH terms: Prostheses and Implants
  4. Hamidi MFFA, Harun WSW, Samykano M, Ghani SAC, Ghazalli Z, Ahmad F, et al.
    Mater Sci Eng C Mater Biol Appl, 2017 Sep 01;78:1263-1276.
    PMID: 28575965 DOI: 10.1016/j.msec.2017.05.016
    Biocompatible metals have been revolutionizing the biomedical field, predominantly in human implant applications, where these metals widely used as a substitute to or as function restoration of degenerated tissues or organs. Powder metallurgy techniques, in specific the metal injection moulding (MIM) process, have been employed for the fabrication of controlled porous structures used for dental and orthopaedic surgical implants. The porous metal implant allows bony tissue ingrowth on the implant surface, thereby enhancing fixation and recovery. This paper elaborates a systematic classification of various biocompatible metals from the aspect of MIM process as used in medical industries. In this study, three biocompatible metals are reviewed-stainless steels, cobalt alloys, and titanium alloys. The applications of MIM technology in biomedicine focusing primarily on the MIM process setting parameters discussed thoroughly. This paper should be of value to investigators who are interested in state of the art of metal powder metallurgy, particularly the MIM technology for biocompatible metal implant design and development.
    Matched MeSH terms: Prostheses and Implants
  5. Aytekin K, Esenyel CZ
    Malays Orthop J, 2018 Mar;12(1):45-47.
    PMID: 29725513 DOI: 10.5704/MOJ.1803.010
    Hip arthroplasty is an extremely satisfying treatment method for coxarthrosis which is in increasing use throughout the world. However, loosening of the prosthesis is a significant complication and to overcome this, ceramic liners are increasingly being selected. If the survival of ceramic surfaces is prolonged, there is a risk of fracture of the ceramic materials. New ceramic materials developed to overcome this problem are more resistant. The case presented here is of a patient in whom liner fracture developed following ceramic-ceramic hip arthroplasty. The ceramic femoral head was observed to have protruded into the defect created in the acetabular component. Acetabular revision was applied to the patient.
    Matched MeSH terms: Prostheses and Implants
  6. Lee SY, Thow SY, Abdullah S, Ng MH, Mohamed Haflah NH
    Int J Nanomedicine, 2022;17:6723-6758.
    PMID: 36600878 DOI: 10.2147/IJN.S362144
    Peripheral nerve injury (PNI) is a worldwide problem which hugely affects the quality of patients' life. Nerve conduits are now the alternative for treatment of PNI to mimic the gold standard, autologous nerve graft. In that case, with the advantages of electrospun micro- or nano-fibers nerve conduit, the peripheral nerve growth can be escalated, in a better way. In this systematic review, we focused on 39 preclinical studies of electrospun nerve conduit, which include the in vitro and in vivo evaluation from animal peripheral nerve defect models, to provide an update on the progress of the development of electrospun nerve conduit over the last 5 years (2016-2021). The physical characteristics, biocompatibility, functional and morphological outcomes of nerve conduits from different studies would be compared, to give a better strategy for treatment of PNI.
    Matched MeSH terms: Prostheses and Implants*
  7. Leung PC
    Med J Malaysia, 1986 Sep;41(3):260-3.
    PMID: 3312975
    When referring to amputation, the immediate association tends to be amputation related to trauma. There is little doubt that injury is by far the commonest cause of amputation, but one must not forget that babies might also be born with amputations of the upper limb. This latter group of amelia composes the various types of congenital amputations.
    Matched MeSH terms: Prostheses and Implants
  8. Mutashar S, Hannan MA, Samad SA, Hussain A
    Sensors (Basel), 2014;14(7):11522-41.
    PMID: 24984057 DOI: 10.3390/s140711522
    The use of wireless communication using inductive links to transfer data and power to implantable microsystems to stimulate and monitor nerves and muscles is increasing. This paper deals with the development of the theoretical analysis and optimization of an inductive link based on coupling and on spiral circular coil geometry. The coil dimensions offer 22 mm of mutual distance in air. However, at 6 mm of distance, the coils offer a power transmission efficiency of 80% in the optimum case and 73% in the worst case via low input impedance, whereas, transmission efficiency is 45% and 32%, respectively, via high input impedance. The simulations were performed in air and with two types of simulated human biological tissues such as dry and wet-skin using a depth of 6 mm. The performance results expound that the combined magnitude of the electric field components surrounding the external coil is approximately 98% of that in air, and for an internal coil, it is approximately 50%, respectively. It can be seen that the gain surrounding coils is almost constant and confirms the omnidirectional pattern associated with such loop antennas which reduces the effect of non-alignment between the two coils. The results also show that the specific absorption rate (SAR) and power loss within the tissue are lower than that of the standard level. Thus, the tissue will not be damaged anymore.
    Matched MeSH terms: Prostheses and Implants*
  9. Murugan K, Faisham WI, Zulmi W
    Malays Orthop J, 2021 Mar;15(1):93-99.
    PMID: 33880154 DOI: 10.5704/MOJ.2103.014
    Introduction: Mega endoprosthesis replacement for resection of primary malignant bone tumour requires immediate and long-term stability, particularly in the young and active patient. Extracortical bone bridge interface (EBBI) is a technique whereby autograft is wrapped around the interface junction of bone and porous-coated implant to induce and enhance bone formation for biological incorporation. This procedure increases the mean torsional stiffness and the mean maximum torque, which eventually improves the implant's long-term survival.

    Material and methods: The extracortical bone bridge interface's radiological parameter was evaluated at the prosthesis bone junction two years after surgery utilising a picture archiving and communication system (PACS). The radiograph's anteroposterior and lateral view was analysed for both thickness and length in all four cortices. The analysis was done in SPSS Version 24 using One-Way ANOVA and independent T-Test. Results were presented as mean and standard deviation and considered significant when the p-value was < 0.05.

    Results: The mean average thickness was 2.2293mm (SD 1.829), and the mean average length was 31.95% (SD 24.55). We observed that the thickness and length of EBBI were superior in the young patient or patients with giant cell tumour that did not receive chemotherapy, compared to patients treated for osteosarcoma. The distal femur also had better EBBI compared to the proximal tibia. However, the final multivariable statistical analysis showed no significant difference in all variables. EBBI thickness was significantly and positively correlated with EBBI Length (p<0.001). We conclude that, for each 1mm increase in EBBI thickness, the length will increase by 0.06% on average. About 17.2% of patients out of the 29 showed no radiological evidence of EBBI.

    Conclusion: From our study, there were no factors that significantly contributed to the formation and incorporation of EBBI.

    Matched MeSH terms: Prostheses and Implants
  10. Mohd Heikal MY, Aminuddin BS, Jeevanan J, Chen HC, Sharifah SH, Ruszymah BH
    Cells Tissues Organs (Print), 2010;192(5):292-302.
    PMID: 20616535 DOI: 10.1159/000318675
    The objective of this study was to regenerate the tracheal epithelium using autologous nasal respiratory epithelial cells in a sheep model. Respiratory epithelium and fibroblast cells were harvested from nasal turbinates and cultured for 1 week. After confluence, respiratory epithelium and fibroblast cells were suspended in autologous fibrin polymerized separately to form a tissue-engineered respiratory epithelial construct (TEREC). A 3 × 2 cm² tracheal mucosal defect was created, and implanted with TEREC and titanium mesh as a temporary scaffold. The control groups were divided into 2 groups: polymerized autologous fibrin devoid of cells (group 1), and no construct implanted (group 2). All sheep were euthanized at 4 weeks of implantation. Gross observation of the trachea showed minimal luminal stenosis formation in the experimental group compared to the control groups. Macroscopic evaluation revealed significant mucosal fibrosis in control group 1 (71.8%) as compared to the experimental group (7%). Hematoxylin and eosin staining revealed the presence of minimal overgrowth of fibrous connective tissue covered by respiratory epithelium. A positive red fluorescence staining of PKH26 on engineered tissue 4 weeks after implantation confirmed the presence of cultured nasal respiratory epithelial cells intercalated with native tracheal epithelial cells. Scanning electron microscopy showed the presence of short microvilli representing immature cilia on the surface of the epithelium. Our study showed that TEREC was a good replacement for a tracheal mucosal defect and was able to promote natural regenesis of the tracheal epithelium with minimal fibrosis. This study highlighted a new technique in the treatment of tracheal stenosis.
    Matched MeSH terms: Prostheses and Implants
  11. Hannan MA, Hussein HA, Mutashar S, Samad SA, Hussain A
    Sensors (Basel), 2014;14(12):23843-70.
    PMID: 25615728 DOI: 10.3390/s141223843
    With the development of communication technologies, the use of wireless systems in biomedical implanted devices has become very useful. Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sides of the biomedical implanted system, in which efficient power amplifier is very much needed to ensure the best data transmission rates and low power losses. However, the efficiency of the implanted devices depends on the circuit design, controller, load variation, changes of radio frequency coil's mutual displacement and coupling coefficients. This paper provides a comprehensive survey on various power amplifier classes and their characteristics, efficiency and controller techniques that have been used in bio-implants. The automatic frequency controller used in biomedical implants such as gate drive switching control, closed loop power control, voltage controlled oscillator, capacitor control and microcontroller frequency control have been explained. Most of these techniques keep the resonance frequency stable in transcutaneous power transfer between the external coil and the coil implanted inside the body. Detailed information including carrier frequency, power efficiency, coils displacement, power consumption, supplied voltage and CMOS chip for the controllers techniques are investigated and summarized in the provided tables. From the rigorous review, it is observed that the existing automatic frequency controller technologies are more or less can capable of performing well in the implant devices; however, the systems are still not up to the mark. Accordingly, current challenges and problems of the typical automatic frequency controller techniques for power amplifiers are illustrated, with a brief suggestions and discussion section concerning the progress of implanted device research in the future. This review will hopefully lead to increasing efforts towards the development of low powered, highly efficient, high data rate and reliable automatic frequency controllers for implanted devices.
    Matched MeSH terms: Prostheses and Implants*
  12. Veerachamy S, Yarlagadda T, Manivasagam G, Yarlagadda PK
    Proc Inst Mech Eng H, 2014 Oct;228(10):1083-99.
    PMID: 25406229 DOI: 10.1177/0954411914556137
    Biofilms are a complex group of microbial cells that adhere to the exopolysaccharide matrix present on the surface of medical devices. Biofilm-associated infections in the medical devices pose a serious problem to the public health and adversely affect the function of the device. Medical implants used in oral and orthopedic surgery are fabricated using alloys such as stainless steel and titanium. The biological behavior, such as osseointegration and its antibacterial activity, essentially depends on both the chemical composition and the morphology of the surface of the device. Surface treatment of medical implants by various physical and chemical techniques are attempted in order to improve their surface properties so as to facilitate bio-integration and prevent bacterial adhesion. The potential source of infection of the surrounding tissue and antimicrobial strategies are from bacteria adherent to or in a biofilm on the implant which should prevent both biofilm formation and tissue colonization. This article provides an overview of bacterial biofilm formation and methods adopted for the inhibition of bacterial adhesion on medical implants.
    Matched MeSH terms: Prostheses and Implants/microbiology*
  13. Mohd Khalid H, Jauhari I, Mohamad Wali HA, Abdulrazzaq Mahmod S
    Biomed Mater, 2017 01 25;12(1):015019.
    PMID: 28120816 DOI: 10.1088/1748-605X/aa4f8b
    In this in vivo study, Sprague Dawley (SD) rats were used to investigate the bioactivity as well as the microstructural and mechanical properties of Ti-6Al-4V samples embedded with hydroxyapatite (HA) using two different coating methods-superplastic embedment (SPE) and superplastic deformation (SPD). The HA layer thickness for the SPE and SPD samples increased from 249.1  ±  0.6 nm to 874.8  ±  13.7 nm, and from 206.1  ±  5.8 nm to 1162.7  ±  7.9 nm respectively, after 12 weeks of implantation. The SPD sample exhibited much faster growth of newly formed HA compared to SPE. The growth of the newly formed HA was strongly dependent on the degree of HA crystallinity in the initial HA layer. After 12 weeks of implantation, the surface hardness value of the SPE and SPD samples decreased from 661  ±  0.4 HV to 586  ±  1.3 HV and from 585  ±  6.6 HV to 425  ±  86.9 HV respectively. The decrease in surface hardness values was due to the newly formed HA layer that was more porous than the initial HA layer. However, the values were still higher than the substrate surface hardness of 321  ±  28.8 HV. Wear test results suggest that the original HA layers for both samples were still strongly intact, and to a certain extent the newly grown HA layers also were strongly bound with the original HA layers. This study confirms the bioactivity and mechanical stability of the HA layer on both samples in vivo.
    Matched MeSH terms: Prostheses and Implants*
  14. Jaganathan SK, Supriyanto E, Murugesan S, Balaji A, Asokan MK
    Biomed Res Int, 2014;2014:459465.
    PMID: 24895577 DOI: 10.1155/2014/459465
    Cardiovascular biomaterials (CB) dominate the category of biomaterials based on the demand and investments in this field. This review article classifies the CB into three major classes, namely, metals, polymers, and biological materials and collates the information about the CB. Blood compatibility is one of the major criteria which limit the use of biomaterials for cardiovascular application. Several key players are associated with blood compatibility and they are discussed in this paper. To enhance the compatibility of the CB, several surface modification strategies were in use currently. Some recent applications of surface modification technology on the materials for cardiovascular devices were also discussed for better understanding. Finally, the current trend of the CB, endothelization of the cardiac implants and utilization of induced human pluripotent stem cells (ihPSCs), is also presented in this review. The field of CB is growing constantly and many new investigators and researchers are developing interest in this domain. This review will serve as a one stop arrangement to quickly grasp the basic research in the field of CB.
    Matched MeSH terms: Prostheses and Implants*
  15. Khalid K
    Med J Malaysia, 2004 May;59 Suppl B:133-4.
    PMID: 15468854
    Matched MeSH terms: Prostheses and Implants*
  16. Abd Razak NA, Abu Osman NA, Gholizadeh H, Ali S
    Biomed Eng Online, 2014;13:134.
    PMID: 25208636 DOI: 10.1186/1475-925X-13-134
    Understanding of kinematics force applied at the elbow is important in many fields, including biomechanics, biomedical engineering and rehabilitation. This paper provides a comparison of a mathematical model of elbow joint using three different types of prosthetics for transhumeral user, and characterizes the forces required to overcome the passive mechanical of the prosthetics at the residual limb.
    Matched MeSH terms: Prostheses and Implants*
  17. Natarajan P, Choudhury M, Seenivasan MK, Jeyapalan K, Natarajan S, Vaidhyanathan AK
    J Pharm Bioallied Sci, 2019 May;11(Suppl 2):S402-S406.
    PMID: 31198377 DOI: 10.4103/JPBS.JPBS_48_19
    Aim: This study evaluated the relationship between missing posterior teeth and body mass index with regard to age and socioeconomic state in a sample of the suburban south Indian population.

    Materials and Methods: The 500 individuals of both males and females aged 40 years and older with missing posterior teeth and not rehabilitated with any prosthesis were gone through a clinical history, intraoral examination, and anthropometric measurement to get information regarding age, sex, socioeconomic status, missing posterior teeth, and body mass index (BMI). Subjects were divided into five groups according to BMI (underweight > 18.5 kg/m2, normal weight 18.5-23 kg/m2, overweight 23-25 kg/m2, obese without surgery 25-32.5 kg/m2, obese with surgery < 32.5 kg/m2). Multivariate logistic regression was used to adjust data according to age, sex, number of missing posterior teeth, and socioeconomic status.

    Results: People with a higher number of tooth loss were more obese. Females with high tooth loss were found to be more obese than male. Low socioeconomic group obese female had significantly higher tooth loss than any other group. No significant relation between age and obesity was found with regard to tooth loss.

    Conclusion: The BMI and tooth loss are interrelated. Management of obesity and tooth loss can help to maintain the overall health status.

    Matched MeSH terms: Prostheses and Implants
  18. Samsudin AR
    Med J Malaysia, 2004 May;59 Suppl B:6.
    PMID: 15468791
    Matched MeSH terms: Prostheses and Implants*
  19. Inayat-Hussain SH, Rajab NF, Roslie H, Hussin AA, Ali AM, Annuar BO
    Med J Malaysia, 2004 May;59 Suppl B:176-7.
    PMID: 15468875
    Biomaterials intended for end-use application as bone-graft substitutes have to undergo safety evaluation. In this study, we investigated the in vitro cytotoxic effects especially to determine the mode of death of two hydroxyapatite compounds (HA2, HA3) which were synthesized locally. The methods used for cytotoxicity was the standard MTT assay whereas AO/PI staining was performed to determine the mode of cell death in HA treated L929 fibroblasts. Our results demonstrated that both HA2 and HA3 were not significantly cytotoxic as more than 75% cells after 72 hours treatment were viable. Furthermore, we found that the major mode of cell death in HA treated cells was apoptosis. In conclusion, our results demonstrated that these hydroxyapatite compounds are not cytotoxic where the mode of death was primarily via apoptosis.
    Matched MeSH terms: Prostheses and Implants*
  20. Asan NB, Hassan E, Shah JVSRM, Noreland D, Blokhuis TJ, Wadbro E, et al.
    Sensors (Basel), 2018 Aug 21;18(9).
    PMID: 30134629 DOI: 10.3390/s18092752
    In this paper, we investigate the use of fat tissue as a communication channel between in-body, implanted devices at R-band frequencies (1.7⁻2.6 GHz). The proposed fat channel is based on an anatomical model of the human body. We propose a novel probe that is optimized to efficiently radiate the R-band frequencies into the fat tissue. We use our probe to evaluate the path loss of the fat channel by studying the channel transmission coefficient over the R-band frequencies. We conduct extensive simulation studies and validate our results by experimentation on phantom and ex-vivo porcine tissue, with good agreement between simulations and experiments. We demonstrate a performance comparison between the fat channel and similar waveguide structures. Our characterization of the fat channel reveals propagation path loss of ∼0.7 dB and ∼1.9 dB per cm for phantom and ex-vivo porcine tissue, respectively. These results demonstrate that fat tissue can be used as a communication channel for high data rate intra-body networks.
    Matched MeSH terms: Prostheses and Implants*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links