Displaying publications 1 - 20 of 168 in total

Abstract:
Sort:
  1. Zanjani KS, Wong AR, Sadiq M, Weber HS, Cutler NG
    Congenit Heart Dis, 2010 Sep-Oct;5(5):439-43.
    PMID: 21087429 DOI: 10.1111/j.1747-0803.2010.00448.x
    Objectives: There is little evidence in the medical literature about safety of PDA device closure and its effects on aortic root diameter in Marfan patients. We reported on nine Marfan patients whose ducts were occluded by coil or Amplatzer Duct Occluder.
    Patients and interventions: Two patients had aneurismal type E ducts which were closed by a single coil, respectively. The others had conical ducts for which even Amplatzer occluder, stiff, or double coils were used.
    Results: No untoward consequence was found during a median follow up period of 18.5 months (range 3 months to 6.33 years). Two patients had small residual shunts. The observed change in the mean ratio of aortic root diameter to its estimated value was statistically insignificant in seven patients who had complete data on their aortic root diameter before PDA closure and during the follow up.
    Conclusions: We concluded that PDA device closure in Marfan patients is safe. Risk of residual shunt is higher even after closure of small ducts.
    Matched MeSH terms: Prosthesis Design
  2. Yong CK, Choon DS, Soon HC
    J Orthop Surg (Hong Kong), 2008 Aug;16(2):197-200.
    PMID: 18725672
    To present midterm results of Duracon total knee arthroplasty (TKA) performed between 1991 and 2001.
    Matched MeSH terms: Prosthesis Design
  3. Yakub MA, Sivalingam S, Dillon J, Matsuhama M, Latiff HA, Ramli MF
    Ann Thorac Surg, 2015 Mar;99(3):884-90; discussion 890.
    PMID: 25579160 DOI: 10.1016/j.athoracsur.2014.09.016
    This study compares the midterm results of mitral valve repair using the biodegradable ring versus repair with non-ring annuloplasty techniques for congenital mitral valve disease in young children where it was not possible to use standard commercial rings.
    Matched MeSH terms: Prosthesis Design
  4. Windecker S, Latib A, Kedhi E, Kirtane AJ, Kandzari DE, Mehran R, et al.
    N Engl J Med, 2020 03 26;382(13):1208-1218.
    PMID: 32050061 DOI: 10.1056/NEJMoa1910021
    BACKGROUND: Polymer-free drug-coated stents provide superior clinical outcomes to bare-metal stents in patients at high bleeding risk who undergo percutaneous coronary intervention (PCI) and are treated with 1 month of dual antiplatelet therapy. Data on the use of polymer-based drug-eluting stents, as compared with polymer-free drug-coated stents, in such patients are limited.

    METHODS: In an international, randomized, single-blind trial, we compared polymer-based zotarolimus-eluting stents with polymer-free umirolimus-coated stents in patients at high bleeding risk. After PCI, patients were treated with 1 month of dual antiplatelet therapy, followed by single antiplatelet therapy. The primary outcome was a safety composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year. The principal secondary outcome was target-lesion failure, an effectiveness composite of death from cardiac causes, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. Both outcomes were powered for noninferiority.

    RESULTS: A total of 1996 patients at high bleeding risk were randomly assigned in a 1:1 ratio to receive zotarolimus-eluting stents (1003 patients) or polymer-free drug-coated stents (993 patients). At 1 year, the primary outcome was observed in 169 of 988 patients (17.1%) in the zotarolimus-eluting stent group and in 164 of 969 (16.9%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% confidence interval [CI], 3.5; noninferiority margin, 4.1; P = 0.01 for noninferiority). The principal secondary outcome was observed in 174 patients (17.6%) in the zotarolimus-eluting stent group and in 169 (17.4%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% CI, 3.5; noninferiority margin, 4.4; P = 0.007 for noninferiority).

    CONCLUSIONS: Among patients at high bleeding risk who received 1 month of dual antiplatelet therapy after PCI, use of polymer-based zotarolimus-eluting stents was noninferior to use of polymer-free drug-coated stents with regard to safety and effectiveness composite outcomes. (Funded by Medtronic; ONYX ONE ClinicalTrials.gov number, NCT03344653.).

    Matched MeSH terms: Prosthesis Design
  5. Wahab AHA, Saad APM, Syahrom A, Kadir MRA
    Comput Methods Biomech Biomed Engin, 2020 Apr;23(5):182-190.
    PMID: 31910663 DOI: 10.1080/10255842.2019.1709828
    Glenoid perforation is not the intended consequence of the surgery and must be avoided. The analysis on biomechanical aspect of glenoid vault perforation remains unknown. The purpose of this study is to determine the impact of glenoid perforation towards stress distribution and micromotion at the interfaces. Eight glenoid implant models had been constructed with various size, number and type of fixation. A load of 750 N was applied to centre, superior-anterior and superior-posterior area. Implant perforation had minimal impact on stress distribution and micromotion at the interfaces. However, cement survival rate for implant without perforation was the highest with a difference of up to 37% compared to other perforated models. Besides that, implant fixation and high stresses at the implant had more of an impact on implant instability than implant perforation. As a conclusion, glenoid perforation did not influence the stress distribution and micromotion, but, it reduced cement survival rate and increase the stress critical volume.
    Matched MeSH terms: Prosthesis Design
  6. Wahab AH, Kadir MR, Harun MN, Kamarul T, Syahrom A
    Med Biol Eng Comput, 2017 Mar;55(3):439-447.
    PMID: 27255451 DOI: 10.1007/s11517-016-1525-6
    The present study was conducted to compare the stability of four commercially available implants by investigating the focal stress distributions and relative micromotion using finite element analysis. Variations in the numbers of pegs between the implant designs were tested. A load of 750 N was applied at three different glenoid positions (SA: superior-anterior; SP: superior-posterior; C: central) to mimic off-center and central loadings during activities of daily living. Focal stress distributions and relative micromotion were measured using Marc Mentat software. The results demonstrated that by increasing the number of pegs from two to five, the total focal stress volumes exceeding 5 MPa, reflecting the stress critical volume (SCV) as the threshold for occurrence of cement microfractures, decreased from 8.41 to 5.21 % in the SA position and from 9.59 to 6.69 % in the SP position. However, in the C position, this change in peg number increased the SCV from 1.37 to 5.86 %. Meanwhile, micromotion appeared to remain within 19-25 µm irrespective of the number of pegs used. In conclusion, four-peg glenoid implants provide the best configuration because they had lower SCV values compared with lesser-peg implants, preserved more bone stock, and reduced PMMA cement usage compared with five-peg implants.
    Matched MeSH terms: Prosthesis Design*
  7. Vohra F, Al-Kheraif AA, Ab Ghani SM, Abu Hassan MI, Alnassar T, Javed F
    J Prosthet Dent, 2015 Sep;114(3):351-7.
    PMID: 26047803 DOI: 10.1016/j.prosdent.2015.03.016
    STATEMENT OF PROBLEM: Zirconia implants have been used for oral rehabilitation; however, evidence of their ability to maintain crestal bone and periimplant soft tissue health is not clear.

    PURPOSE: The purpose of this systematic review was to evaluate crestal bone loss (CBL) around zirconia dental implants and clinical periimplant inflammatory parameters.

    MATERIAL AND METHODS: The focus question addressed was, "Do zirconia implants maintain crestal bone levels and periimplant soft tissue health?" Databases were searched for articles from 1977 through September 2014 with different combinations of the following MeSH terms: "dental implants," "zirconium," "alveolar bone loss," "periodontal attachment loss," "periodontal pocket," "periodontal index." Letters to the editor, case reports, commentaries, review articles, and articles published in languages other than English were excluded.

    RESULTS: Thirteen clinical studies were included. In 8 of the studies, the CBL around zirconia implants was comparable between baseline and follow-up. In the other 5 studies, the CBL around zirconia implants was significantly higher at follow-up. Among the studies that used titanium implants as controls, 2 studies showed significantly higher CBL around zirconia implants, and in 1 study, the CBL around zirconia and titanium implants was comparable. The reported implant survival rates for zirconia implants ranged between 67.6% and 100%. Eleven studies selectively reported the periimplant inflammatory parameters.

    CONCLUSIONS: Because of the variations in study design and methodology, it was difficult to reach a consensus regarding the efficacy of zirconia implants in maintaining crestal bone levels and periimplant soft tissue health.

    Matched MeSH terms: Dental Prosthesis Design
  8. Velayudhan BV, Idhrees M, Matalanis G, Park KH, Tang D, Sfeir PM, et al.
    J Cardiovasc Surg (Torino), 2020 Jun;61(3):285-291.
    PMID: 32337940 DOI: 10.23736/S0021-9509.20.11397-1
    Acute type A aortic dissection remains one of the most challenging conditions in aortic surgery. Despite the advancements in the field, the mortality rate still remains high. Though there is a general consensus that the ascending aorta should be replaced, the distal extension of the surgery still remains a controversy. Few surgeons argue for a conservative approach to reduce operative and postoperative morbidity while others considering the problems associated with "downstream problems" support an aggressive approach including a frozen elephant trunk. The cohort in the Indian subcontinent and APAC is far different from the western world. Many factors determine the decision for surgery apart from the pathology of the disease. Economy, availability of the suitable prosthesis, the experience of the surgeon, ease of access to the medical facility all contribute to the decision making to treat acute type A dissection.
    Matched MeSH terms: Prosthesis Design
  9. Urban P, Meredith IT, Abizaid A, Pocock SJ, Carrié D, Naber C, et al.
    N Engl J Med, 2015 Nov 19;373(21):2038-47.
    PMID: 26466021 DOI: 10.1056/NEJMoa1503943
    BACKGROUND: Patients at high risk for bleeding who undergo percutaneous coronary intervention (PCI) often receive bare-metal stents followed by 1 month of dual antiplatelet therapy. We studied a polymer-free and carrier-free drug-coated stent that transfers umirolimus (also known as biolimus A9), a highly lipophilic sirolimus analogue, into the vessel wall over a period of 1 month.
    METHODS: In a randomized, double-blind trial, we compared the drug-coated stent with a very similar bare-metal stent in patients with a high risk of bleeding who underwent PCI. All patients received 1 month of dual antiplatelet therapy. The primary safety end point, tested for both noninferiority and superiority, was a composite of cardiac death, myocardial infarction, or stent thrombosis. The primary efficacy end point was clinically driven target-lesion revascularization.
    RESULTS: We enrolled 2466 patients. At 390 days, the primary safety end point had occurred in 112 patients (9.4%) in the drug-coated-stent group and in 154 patients (12.9%) in the bare-metal-stent group (risk difference, -3.6 percentage points; 95% confidence interval [CI], -6.1 to -1.0; hazard ratio, 0.71; 95% CI, 0.56 to 0.91; P<0.001 for noninferiority and P=0.005 for superiority). During the same time period, clinically driven target-lesion revascularization was needed in 59 patients (5.1%) in the drug-coated-stent group and in 113 patients (9.8%) in the bare-metal-stent group (risk difference, -4.8 percentage points; 95% CI, -6.9 to -2.6; hazard ratio, 0.50; 95% CI, 0.37 to 0.69; P<0.001).
    CONCLUSIONS: Among patients at high risk for bleeding who underwent PCI, a polymer-free umirolimus-coated stent was superior to a bare-metal stent with respect to the primary safety and efficacy end points when used with a 1-month course of dual antiplatelet therapy. (Funded by Biosensors Europe; LEADERS FREE ClinicalTrials.gov number, NCT01623180.).
    Matched MeSH terms: Prosthesis Design
  10. Tenekecioglu E, Serruys PW, Onuma Y, Costa R, Chamié D, Sotomi Y, et al.
    JACC Cardiovasc Interv, 2017 06 12;10(11):1115-1130.
    PMID: 28527768 DOI: 10.1016/j.jcin.2017.03.015
    OBJECTIVES: The primary objective of this study was to evaluate the safety and effectiveness of the Mirage (Manli Cardiology, Singapore) bioresorbable microfiber sirolimus-eluting scaffold compared with the Absorb (Abbott Vascular, Santa Clara, California) bioresorbable vascular scaffold in the treatment of stenotic target lesions located in native coronary arteries, ranging from ≥2.25 to ≤4.0 mm in diameter. Secondary objectives were to establish the medium-term safety, effectiveness, and performance of the Mirage device.

    BACKGROUND: The current generation of bioresorbable scaffolds has several limitations, such as thick square struts with large footprints that preclude their deep embedment into the vessel wall, resulting in protrusion into the lumen with microdisturbance of flow. The Mirage sirolimus-eluting bioresorbable microfiber scaffold is designed to address these concerns.

    METHODS: In this prospective, single-blind trial, 60 patients were randomly allocated in a 1:1 ratio to treatment with a Mirage sirolimus-eluting bioresorbable microfiber scaffold or an Absorb bioresorbable vascular scaffold. The clinical endpoints were assessed at 30 days and at 6 and 12 months. In-device angiographic late loss at 12 months was quantified. Secondary optical coherence tomographic endpoints were assessed post-scaffold implantation at 6 and 12 months.

    RESULTS: Median angiographic post-procedural in-scaffold minimal luminal diameters of the Mirage and Absorb devices were 2.38 mm (interquartile range [IQR]: 2.06 to 2.62 mm) and 2.55 mm (IQR: 2.26 to 2.71 mm), respectively; the effect size (d) was -0.29. At 12 months, median angiographic in-scaffold minimal luminal diameters of the Mirage and Absorb devices were not statistically different (1.90 mm [IQR: 1.57 to 2.31 mm] vs. 2.29 mm [IQR: 1.74 to 2.51 mm], d = -0.36). At 12-month follow-up, median in-scaffold late luminal loss with the Mirage and Absorb devices was 0.37 mm (IQR: 0.08 to 0.72 mm) and 0.23 mm (IQR: 0.15 to 0.37 mm), respectively (d = 0.20). On optical coherence tomography, post-procedural diameter stenosis with the Mirage was 11.2 ± 7.1%, which increased to 27.4 ± 12.4% at 6 months and remained stable (31.8 ± 12.9%) at 1 year, whereas the post-procedural optical coherence tomographic diameter stenosis with the Absorb was 8.4 ± 6.6%, which increased to 16.6 ± 8.9% and remained stable (21.2 ± 9.9%) at 1-year follow-up (Mirage vs. Absorb: dpost-procedure = 0.41, d6 months = 1.00, d12 months = 0.92). Angiographic median in-scaffold diameter stenosis was significantly different between study groups at 12 months (28.6% [IQR: 21.0% to 40.7%] for the Mirage, 18.2% [IQR: 13.1% to 31.6%] for the Absorb, d = 0.39). Device- and patient-oriented composite endpoints were comparable between the 2 study groups.

    CONCLUSIONS: At 12 months, angiographic in-scaffold late loss was not statistically different between the Mirage and Absorb devices, although diameter stenosis on angiography and on optical coherence tomography was significantly higher with the Mirage than with the Absorb. The technique of implantation was suboptimal for both devices, and future trials should incorporate optical coherence tomographic guidance to allow optimal implantation and appropriate assessment of the new technology, considering the novel mechanical properties of the Mirage.

    Matched MeSH terms: Prosthesis Design
  11. Tarib NA, Seong TW, Chuen KM, Kun MS, Ahmad M, Kamarudin KH
    Eur J Prosthodont Restor Dent, 2012 Mar;20(1):35-9.
    PMID: 22474935
    This paper aims to evaluate the effect of splinting during implant impression. A master model with two fixtures at the sites of 45 and 47 was used. 20 impressions were made for all four techniques: (A) indirect; (B) direct, unsplinted; (C) direct, splinted; and (D) direct, splinted, sectioned, and re-splinted. Splinting was undertaken with autopolymerizing acrylic resin (AAR). Horizontal distance between fixtures was compared using a digital caliper. The difference in distance were analysed with one-way ANOVA. Group A showed a significantly lowest accuracy among all techniques (p < or = 0.05). There was no significant difference of accuracy among the groups using direct techniques (p > or = 0.05). Group D was more accurate compared to group B and C. We conclude that splinting of impression copings would be beneficial to obtain an accurate impression.
    Matched MeSH terms: Dental Prosthesis Design*
  12. Tan WJ, Kwan MK, Deepak AS, Saw A, Peng BC, Jalalullah W
    Med J Malaysia, 2006 Dec;61 Suppl B:18-22.
    PMID: 17600988
    Fracture of the femur is most commonly treated with interlocking nailing. We conducted this study to describe and analyze the size of femoral interlocking nails used in our local population. This is a retrospective study on reamed intramedullary interlocking nailing procedures performed between 1st July 1998 and 30th June 2003. Demographic data, the diameter and length of femoral nails used were obtained from patient's medical record. A total of 267 procedures were included. The most common diameter used was 10 mm (56.9%), followed by 11 mm (27.0%) and 12 mm (13.1%). Only 2.6% of the nails were less than 10 mm in diameter. The most common nail length was 38 cm (31.1%), followed by 36 cm (24.9%) and 40 cm (19.5%). The longest nail used was 46 cm while the shortest 32 cm. The most commonly used femoral nails were of 10 mm diameter with the length ranging from 36 to 40 cm, which is smaller than those reported in the English literature. Nails with diameter smaller than 10 mm were required in 2.6% of patients.
    Matched MeSH terms: Prosthesis Design
  13. Tai CC, Cross MJ
    J Bone Joint Surg Br, 2006 Sep;88(9):1158-63.
    PMID: 16943464
    We carried out a prospective study of 118 hydroxyapatite-coated, cementless total knee replacements in patients who were = 55 years of age and who had primary (92; 78%) or post-traumatic (26; 22%) osteoarthritis. The mean period of follow-up was 7.9 years (5 to 12.5). The Knee Society clinical scores improved from a pre-operative mean of 98 (0 to 137) to a mean of 185 (135 to 200) at five years, and 173 (137 to 200) at ten years. There were two revisions of the tibial component because of aseptic loosening, and one case of polyethylene wear requiring further surgery. There was no osteolysis or progressive radiological loosening of any other component. At 12 years, the overall rate of implant survival was 97.5% (excluding exchange of spacer) and 92.1% (including exchange of spacer). Cementless total knee replacement can achieve excellent long-term results in young, active patients with osteoarthritis. In contrast to total hip replacement, polyethylene wear, osteolysis and loosening of the prosthesis were not major problems for these patients, although it is possible that this observation could change with longer periods of follow-up.
    Matched MeSH terms: Prosthesis Design
  14. Subramaniam R, Mani MP, Jaganathan SK
    Cardiovasc Eng Technol, 2018 09;9(3):503-513.
    PMID: 29700782 DOI: 10.1007/s13239-018-0357-y
    In this study, a small vascular graft based on polyurethane (PU) blended with chitosan (Ch) nanoparticles was fabricated using electrospinning technique. Initially, the chitosan nanoparticles were synthesized using ionic gelation method. UV-Vis spectrophotometer confirmed the presence of synthesized Ch nanoparticles by exhibiting absorption peak at 288 nm and the Fourier-transform infrared spectroscopy (FTIR) analysis confirmed the existence of the chitosan. Further, the synthesized Ch nanoparticles showed size diameter in the range of 134 ± 58 nm as measured using ImageJ. In the electrospun PU/chitosan graft, the fiber diameter and pore size diameter was found to be reduced compared to the pure PU owing to incorporation of chitosan into PU matrix. The FTIR spectrum revealed the presence of chitosan in the prepared nanocomposite membrane by the formation of the hydrogen bond and peak shift of CH and NH stretching. Moreover, the contact angle measurements revealed that the prepared graft showed decreased contact angle indicating hydrophilic nature compared to the pristine PU. The cytocompatibility studies revealed the non-toxic behavior of the fabricated graft. Hence, the prepared graft exhibiting significant physiochemical and non-toxic properties may be a plausible candidate for cardiovascular graft applications.
    Matched MeSH terms: Prosthesis Design
  15. Soo CS, Ca M, Tay M, Yeoh JK, Sim E, Choo M
    J Am Soc Echocardiogr, 1994 3 1;7(2):159-64.
    PMID: 8185960
    We prospectively studied 37 consecutive patients implanted with the Carbomedics prosthetic heart value in the mitral position (without clinical evidence of prosthetic valve dysfunction) with two-dimensional and Doppler echocardiography. The peak mitral prosthetic gradient ranged from 4.60 to 14.63 (mean 8.97 +/- 2.29) mm Hg; mean mitral prosthetic gradient ranged from 1.67 to 6.18 (mean 3.24 +/- 0.95) mm Hg; pressure half-time derived mitral valve area ranged from 1.67 to 5.30 (mean 2.70 +/- 0.80) cm2. These values compare favorably with that of another bileaflet valve (i.e., the St. Jude Medical valve). There was a wide overlap in peak and mean transmitral gradients, even with the valves of the same size, with a significant but weak inverse relationship between peak mitral gradients and valve size (p = 0.03, r = -0.36). The performance index showed a smaller range of values, again with a significant but weak inverse relationship with valve size (p = 0.001, r = -0.54). The inverse relationship between valve size and peak mitral gradient and performance index should be borne in mind when analyzing Doppler hemodynamic data.
    Matched MeSH terms: Prosthesis Design
  16. Soliman MM, Islam MT, Chowdhury MEH, Alqahtani A, Musharavati F, Alam T, et al.
    J Mater Chem B, 2023 Nov 15;11(44):10507-10537.
    PMID: 37873807 DOI: 10.1039/d3tb01469j
    The UK's National Joint Registry (NJR) and the American Joint Replacement Registry (AJRR) of 2022 revealed that total hip replacement (THR) is the most common orthopaedic joint procedure. The NJR also noted that 10-20% of hip implants require revision within 1 to 10 years. Most of these revisions are a result of aseptic loosening, dislocation, implant wear, implant fracture, and joint incompatibility, which are all caused by implant geometry disparity. The primary purpose of this review article is to analyze and evaluate the mechanics and performance factors of advancement in hip implants with novel geometries. The existing hip implants can be categorized based on two parts: the hip stem and the joint of the implant. Insufficient stress distribution from implants to the femur can cause stress shielding, bone loss, excessive micromotion, and ultimately, implant aseptic loosening due to inflammation. Researchers are designing hip implants with a porous lattice and functionally graded material (FGM) stems, femur resurfacing, short-stem, and collared stems, all aimed at achieving uniform stress distribution and promoting adequate bone remodeling. Designing hip implants with a porous lattice FGM structure requires maintaining stiffness, strength, isotropy, and bone development potential. Mechanical stability is still an issue with hip implants, femur resurfacing, collared stems, and short stems. Hip implants are being developed with a variety of joint geometries to decrease wear, improve an angular range of motion, and strengthen mechanical stability at the joint interface. Dual mobility and reverse femoral head-liner hip implants reduce the hip joint's dislocation limits. In addition, researchers reveal that femoral headliner joints with unidirectional motion have a lower wear rate than traditional ball-and-socket joints. Based on research findings and gaps, a hypothesis is formulated by the authors proposing a hip implant with a collared stem and porous lattice FGM structure to address stress shielding and micromotion issues. A hypothesis is also formulated by the authors suggesting that the utilization of a spiral or gear-shaped thread with a matched contact point at the tapered joint of a hip implant could be a viable option for reducing wear and enhancing stability. The literature analysis underscores substantial research opportunities in developing a hip implant joint that addresses both dislocation and increased wear rates. Finally, this review explores potential solutions to existing obstacles in developing a better hip implant system.
    Matched MeSH terms: Prosthesis Design