OBJECTIVE: We examined for differences in 1-year clinical outcomes after PCI by maximum implanted stent diameter from the COMBO collaboration.
METHODS: The COMBO collaboration (n = 3614) is a patient-level pooled dataset of patients undergoing PCI with COMBO stents in the MASCOT and REMEDEE multicenter registries. Stent diameter was available in 3590 (99.3%) patients. We compared patients receiving COMBO stents <3 mm versus ≥3 mm. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel-myocardial infarction (TV-MI) or clinically driven TLR. Secondary outcomes included stent thrombosis (ST). Adjusted outcomes were assessed using Cox regression methods.
RESULTS: The study included 792 (22%) patients with small stents <3 mm and 2798 (78%) patients with large stents ≥3 mm. Small stent patients included more women with lower body mass index and higher prevalence of diabetes but similar prevalence of acute coronary syndrome. Risk of 1-year TLF was similar in small and large stent groups (4.4% vs. 3.8%, HR 1.12, 95% CI 0.74-1.72, p = 0.58). There were no differences in the rates of cardiac death (1.7% vs. 1.5%, p = 0.74), TV-MI (1.4% vs. 1.2%, p = 0.58) or TLR (2.7% vs. 2.1%, p = 0.31). Definite or probable ST occurred in 1.3% of the small stent and 0.7% of the large stent PCI patients, p = 0.14, HR 2.13, 95% CI 0.93-5.00, p = 0.07.
CONCLUSIONS: One-year ischemic outcomes after COMBO PCI were similar irrespective of stent diameter in this all-comers international cohort.
OBJECTIVE: We investigated for geographical differences in outcomes after percutaneous coronary intervention (PCI) with the COMBO stent among Asians and Europeans.
METHODS: The COMBO Collaboration is a pooled patient-level analysis of the MASCOT and REMEDEE registries of all-comers undergoing attempted COMBO stent PCI. The primary outcome was 1-year target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction (TV-MI) and target lesion revascularization (TLR).
RESULTS: This study included 604 Asians (17.9%) and 2775 Europeans (82.1%). Asians were younger and included fewer females, with a higher prevalence of diabetes mellitus but lower prevalence of other comorbidities than Europeans. Asians had a higher prevalence of ACC/AHA C type lesions and received longer stent lengths. More Asians than Europeans were discharged on clopidogrel (86.5% vs 62.8%) rather than potent P2Y12 inhibitors. One-year TLF occurred in 4.0% Asians and 4.1% of Europeans, p = 0.93. The incidence of cardiac death was higher in Asians (2.8% vs. 1.3%, p = 0.007) with similar rates of TV-MI (1.5% vs. 1.2%, p = 0.54) and definite stent thrombosis (0.3% vs. 0.5%, p = 0.84) and lower incidence of TLR than Europeans (1.0% vs. 2.5%, p = 0.025). After adjustment, differences for cardiac death and TLR were no longer significant.
CONCLUSIONS: In the COMBO collaboration, although 1-year TLF was similar regardless of geography, Asians experienced higher rates of cardiac death and lower TLR than Europeans, while incidence of TV-MI and ST was similar in both regions. Adjusted differences did not reach statistical significance. CLINICALTRIAL.
GOV IDENTIFIER-NUMBERS: NCT01874002 (REMEDEE Registry), NCT02183454 (MASCOT registry).
CASE DESCRIPTION AND METHODS: The subject had unstable excessive soft tissue at the distal end of the residuum. After 2 years of prosthetic use, she experienced several problems, including pain in the residual limb and knee joint. Pressure distribution was evaluated during ambulation. We also designed a total surface bearing socket with Velcro as suspension system to distribute the load evenly on the residual limb, and to facilitate donning procedure.
FINDINGS AND OUTCOMES: The main site of weight bearing in the old prosthesis (patellar tendon bearing) was anterior proximal region of the residual limb, especially the patellar tendon. The pressure was almost 10 times higher than the distal region during level walking. Pressures were distributed more evenly with the total surface bearing socket design, and the donning was much easier.
CONCLUSION: Pressure distribution within the socket could be affected by socket design and suspension system. Using the total surface bearing socket and Velcro as suspension system might facilitate donning of prosthesis and reduce traction at the end of residual limb during the swing phase of gait.
CLINICAL RELEVANCE: Proper socket design and suspension system based on the amputees' need can facilitate rehabilitation process and lead to the amputee's satisfaction. The pressure is distributed more uniformly over the residual limb by the total surface bearing socket compared to the patellar tendon bearing socket for lower limb amputees with unusual stump shape.
METHODS: Forty direct impressions of a mandibular reference model fitted with six dental implants and multibase abutments were made using VPES and PE, and implant casts were poured (N = 20). The VPES and PE groups were split into four subgroups of five each, based on splinting type: (a) no splinting; (b) bite registration polyether; (c) bite registration addition silicone; and (d) autopolymerizing acrylic resin. The accuracy of implant-abutment replica positions was calculated on the experimental casts, in terms of interimplant distances in the x, y, and z-axes, using a coordinate measuring machine; values were compared with those measured on the reference model. Data were analyzed using non-parametrical Kruskal-Wallis and Mann-Whitney tests at α = .05.
RESULTS: The differences between the two impression materials, VPES and PE, regardless of splinting type, were not statistically significant (P>.05). Non-splinting and splinting groups were also not significantly different for both PE and VPES (P>.05).
CONCLUSIONS: The accuracy of VPES impression material seemed comparable with PE for multi-implant abutment-level impressions. Splinting had no effect on the accuracy of implant impressions.
METHODS: Four electronic full-text databases were systematically searched through September 2017. Data including outcomes of annular closure device/annular repair were extracted. All results were pooled utilising meta-analysis with weighted mean difference and odds ratio as summary statistics.
RESULTS: Four studies met inclusion criteria. Three studies reported the use of Barricaid (ACD) while one study reported the use of Anulex (AR). A total of 24 symptomatic reherniation were reported among 811 discectomies with ACD/AR as compared to 51 out of 645 in the control group (OR: 0.34; 95% CI: 0.20,0.56; I2 = 0%; P