Displaying publications 1 - 20 of 168 in total

Abstract:
Sort:
  1. Krackhardt F, Kočka V, Waliszewski M, Toušek P, Janek B, Trenčan M, et al.
    Medicine (Baltimore), 2020 Feb;99(8):e19119.
    PMID: 32080086 DOI: 10.1097/MD.0000000000019119
    Stent designs with ultrathin struts may further increase the procedural success of challenging lesion subsets. The objective of this study was to assess the safety and efficacy of ultrathin strut, polymer-free sirolimus eluting stent (PF-SES) implantations in a large scale, unselected patient population.Adult patients underwent percutaneous coronary interventions (PCI) with a thin-strut PF-SES. Data from two all-comers observational studies having the same protocol (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were pooled. The accumulated target lesion revascularization (TLR) rate at 9-12 months was the primary endpoint. All dual antiplatelet therapy strategies according to the applicable guidelines were permissible.In total, 7243 patients were prospectively enrolled for PCI with PF-SES in stable coronary artery disease or acute coronary syndrome (ACS). Major risk factors in the overall cohort were diabetes (37.3%), ST elevation myocardial infarction (18.1%) and non-ST myocardial infarction (24.6%). The follow-up rate was 88.6% in the overall population. The TLR rate in the overall cohort was 2.2% whereas definite/probable stent thrombosis (ST) occurred in 0.7%. In patients with in-stent restenosis lesions, the major adverse cardiac events rate was 6.4% whereas the corresponding rate for isolated left main coronary artery (LMCA) disease was highest with 6.7% followed by patients with culprit lesions in vein bypasses (VB, 7.1%). The mortality rate in patients treated in VB lesions was highest with 5.4%, followed by the isolated LMCA subgroup (3.4%) and ACS (2.6%).PCI with PF-SES in an unselected patient population, is associated with low clinical event and ST rates. Furthermore, PF-SES angioplasty in niche indications demonstrated favorable safety and efficacy outcomes with high procedural success rates.
    Matched MeSH terms: Prosthesis Design
  2. Leenders GE, Liew HB, Stella PR
    Cardiovasc Revasc Med, 2018 12;19(8S):58-59.
    PMID: 30115559 DOI: 10.1016/j.carrev.2018.03.016
    A 62-year old male underwent treatment of a bifurcation lesion in the left anterior descending coronary artery using provisional stenting with a jailed wire technique. Severe longitudinal stent deformation and unravelment of the stent part proximal of the bifurcation occurred when we tried to pull the jailed wire from the side branch. The described case poses a caution on the use of this specific stent(-design) in bifurcation lesions.
    Matched MeSH terms: Prosthesis Design
  3. Baig MR, Rajan G
    J Oral Implantol, 2010;36(1):31-5.
    PMID: 20218868 DOI: 10.1563/AAID-JOI-D-09-00062
    This article describes the dental implant-based rehabilitation of a partially edentulous patient with a unilateral maxillary dento-alveolar defect. A screw-retained prosthesis with a modified design was fabricated on zygomatic and regular dental implants. One section of the implant prosthesis has cemented crowns and the other section is conventional screw-retained. The design of the prosthesis overcame the hard and soft tissue deficit and provided the desired esthetics.
    Matched MeSH terms: Dental Prosthesis Design
  4. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S, Sævarsson SK, Wan Abas WA, et al.
    J Rehabil Res Dev, 2012;49(9):1321-30.
    PMID: 23408214
    Poor suspension increases slippage of the residual limb inside the socket during ambulation. The main purpose of this article is to evaluate the pistoning at the prosthetic liner-socket interface during gait and assess patients' satisfaction with two different liners. Two prostheses with seal-in and locking liners were fabricated for each of the 10 subjects with transtibial amputation. The Vicon motion system was used to measure the pistoning during gait. The subjects were also asked to complete a Prosthesis Evaluation Questionnaire. The results revealed higher pistoning inside the socket during gait with the locking liner than with the seal-in liner (p < 0.05). The overall satisfaction with the locking liner was higher (p < 0.05) because of the relative ease with which the patients could don and doff the device. As such, pistoning may not be the main factor that determines patients' overall satisfaction with the prosthesis and other factors may also contribute to comfort and satisfaction with prostheses. The article also verifies the feasibility of the Vicon motion system for measuring pistoning during gait.
    Matched MeSH terms: Prosthesis Design*
  5. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S, Razak NA
    Clin Biomech (Bristol, Avon), 2014 Jan;29(1):87-97.
    PMID: 24315710 DOI: 10.1016/j.clinbiomech.2013.10.013
    Today a number of prosthetic suspension systems are available for transtibial amputees. Consideration of an appropriate suspension system can ensure that amputee's functional needs are satisfied. The higher the insight to suspension systems, the easier would be the selection for prosthetists. This review attempted to find scientific evidence pertaining to various transtibial suspension systems to provide selection criteria for clinicians.
    Matched MeSH terms: Prosthesis Design*
  6. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S
    Am J Phys Med Rehabil, 2014 Sep;93(9):809-23.
    PMID: 24743451 DOI: 10.1097/PHM.0000000000000094
    The purpose of this study was to find the scientific evidence pertaining to various transfemoral suspension systems to provide selection criteria for clinicians. To this end, databases of PubMed, Web of Science, and ScienceDirect were explored. The following key words, as well as their combinations and synonyms, were used for the search: transfemoral prosthesis, prosthetic suspension, lower limb prosthesis, above-knee prosthesis, prosthetic liner, transfemoral, and prosthetic socket. The study design, research instrument, sampling method, outcome measures, and protocols of articles were reviewed. On the basis of the selection criteria, 16 articles (11 prospective studies and 5 surveys) were reviewed. The main causes of reluctance to prosthesis, aside from energy expenditure, were socket-related problems such as discomfort, perspiration, and skin problems. Osseointegration was a suspension option, yet it is rarely applied because of several drawbacks, such as extended rehabilitation process, risk for fracture, and infection along with excessive cost. In conclusion, no clinical evidence was found as a "standard" system of suspension and socket design for all transfemoral amputees. However, among various suspension systems for transfemoral amputees, the soft insert or double socket was favored by most users in terms of function and comfort.
    Matched MeSH terms: Prosthesis Design*
  7. Pang YK, Liam CK, Leow CH, Shyamala P, Zal AR
    Med J Malaysia, 2006 Jun;61(2):147-50.
    PMID: 16898303 MyJurnal
    Many studies have shown that tracheobronchial stenting is effective in relieving respiratory distress secondary to major airway obstruction due to lung or oesophageal cancer. A retrospective review on the benefits and complications of self-expandable metallic stent (SEMS) insertion through flexible bronchoscopy for the palliative treatment of upper airway obstruction in University Malaya Medical Centre was performed. Ten patients underwent this procedure. Relief of dyspnoea was immediate following stent insertion in all patients. Stent migration occurred in one patient and three patients had restenosis of the central airway. We conclude that tracheobronchial stenting via flexible bronchoscopy is feasible and safe.
    Matched MeSH terms: Prosthesis Design
  8. Mori Y, Itoi T, Baron TH, Takada T, Strasberg SM, Pitt HA, et al.
    J Hepatobiliary Pancreat Sci, 2018 Jan;25(1):87-95.
    PMID: 28888080 DOI: 10.1002/jhbp.504
    Since the publication of the Tokyo Guidelines in 2007 and their revision in 2013, appropriate management for acute cholecystitis has been more clearly established. Since the last revision, several manuscripts, especially for alternative endoscopic techniques, have been reported; therefore, additional evaluation and refinement of the 2013 Guidelines is required. We describe a standard drainage method for surgically high-risk patients with acute cholecystitis and the latest developed endoscopic gallbladder drainage techniques described in the updated Tokyo Guidelines 2018 (TG18). Our study confirmed that percutaneous transhepatic gallbladder drainage should be considered the first alternative to surgical intervention in surgically high-risk patients with acute cholecystitis. Also, endoscopic transpapillary gallbladder drainage or endoscopic ultrasound-guided gallbladder drainage can be considered in high-volume institutes by skilled endoscopists. In the endoscopic transpapillary approach, either endoscopic naso-gallbladder drainage or gallbladder stenting can be considered for gallbladder drainage. We also introduce special techniques and the latest outcomes of endoscopic ultrasound-guided gallbladder drainage studies. Free full articles and mobile app of TG18 are available at: http://www.jshbps.jp/modules/en/index.php?content_id=47. Related clinical questions and references are also included.
    Matched MeSH terms: Prosthesis Design
  9. Leschke M, Waliszewski M, Pons M, Champin S, Nait Saidi L, Mok Heang T, et al.
    Catheter Cardiovasc Interv, 2016 Sep;88(3):358-66.
    PMID: 26650913 DOI: 10.1002/ccd.26261
    OBJECTIVES: This observational study assessed the 9-month clinical outcomes in an « all comers » population with a focus on patients with atrial fibrillation (AF) after thin strut bare metal stenting.

    BACKGROUND: Drug eluting stent (DES) implantation is the treatment of choice for coronary artery disease (CAD) leaving only marginal indications for the use of bare metal stents (BMS). However, selected treatment populations with DES contraindications such as patients who cannot sustain 6-12 months of dual antiplatelet therapy (DAPT) remain candidates for BMS implantations.

    METHODS: Thin strut bare metal stenting in a priori defined subgroups were investigated in a non-randomized, international, multicenter «all comers» observational study. Primary endpoint was the 9-month TLR rate whereas secondary endpoints included the 9-month MACE and procedural success rates.

    RESULTS: A total of 783 patients of whom 98 patients had AF underwent BMS implantation. Patient age was 70.4 ± 12.8 years. Cardiovascular risk factors in the overall population were male gender (78.2%, 612/783), diabetes (25.2%, 197/783), hypertension (64.1%, 502/783), cardiogenic shock (4.9%, 38/783) and end stage renal disease (4.9%, 38/783). In-hospital MACE was 4.1% (30/783) in the overall population. The 9-month TLR rate was 4.5% (29/645) in the non-AF group and 3.3% (3/90) in the AF group (P = 0.613). At 9 months, the MACE rate in the AF-group and non-AF group was not significantly different either (10.7%, 69/645 vs. 6.7%, 6/90; P = 0.237). Accumulated stroke rates were 0.3% (2/645) in the non-AF subgroup at baseline and 1.1% (1/90) in the AF subgroup (P = 0.264).

    CONCLUSION: Bare metal stenting in AF patients delivered acceptably low TLR and MACE rates while having the benefit of a significantly shorter DAPT duration in a DES dominated clinical practice. © 2015 Wiley Periodicals, Inc.

    Matched MeSH terms: Prosthesis Design
  10. Patil PG, Lim HF
    J Prosthet Dent, 2023 Jul;130(1):14-18.
    PMID: 34774303 DOI: 10.1016/j.prosdent.2021.08.005
    Fabricating a new crown to retrofit with an existing removable partial denture (RPD) is a complex procedure for both clinician and dental laboratory technician. The presented technique facilitates the fabrication and retrofitting of a metal-ceramic crown onto the principal abutment of the existing RPD by using 2-step intraoral scanning (with and without the RPD in place) and 2 different 3-dimensionally printed casts. The technique enables the dental laboratory technician to precisely reproduce the retentive areas, guiding planes, and rest seats on the retrofitted crown.
    Matched MeSH terms: Dental Prosthesis Design
  11. Alizadeh M, Kadir MR, Fadhli MM, Fallahiarezoodar A, Azmi B, Murali MR, et al.
    J Orthop Res, 2013 Sep;31(9):1447-54.
    PMID: 23640802 DOI: 10.1002/jor.22376
    Posterior instrumentation is a common fixation method used to treat thoracolumbar burst fractures. However, the role of different cross-link configurations in improving fixation stability in these fractures has not been established. A 3D finite element model of T11-L3 was used to investigate the biomechanical behavior of short (2 level) and long (4 level) segmental spine pedicle screw fixation with various cross-links to treat a hypothetical L1 vertebra burst fracture. Three types of cross-link configurations with an applied moment of 7.5 Nm and 200 N axial force were evaluated. The long construct was stiffer than the short construct irrespective of whether the cross-links were used (p < 0.05). The short constructs showed no significant differences between the cross-link configurations. The XL cross-link provided the highest stiffness and was 14.9% stiffer than the one without a cross-link. The long construct resulted in reduced stress to the adjacent vertebral bodies and screw necks, with 66.7% reduction in bending stress on L2 when the XL cross-link was used. Thus, the stability for L1 burst fracture fixation was best achieved by using long segmental posterior instrumentation constructs and an XL cross-link configuration. Cross-links did not improved stability when a short structure was used.
    Matched MeSH terms: Prosthesis Design*
  12. Abu Osman NA, Spence WD, Solomonidis SE, Paul JP, Weir AM
    Med Eng Phys, 2010 Sep;32(7):760-5.
    PMID: 20678997 DOI: 10.1016/j.medengphy.2010.04.020
    The purpose of this investigation was to vary the load on the patellar tendon bar and to study the subsequent effect this has on the pattern of the pressure distribution at the stump-socket interface. Ten male subjects from the Southern General Hospital in Glasgow, UK participated in this study. Measuring systems utilising strain gauge and electrohydraulic technologies were designed, developed and constructed to enable pressure measurements to be conducted. One transducer, the patellar tendon (PT) transducer, was attached to the patellar tendon bar of the socket such that the patellar tendon bar was capable of being translated by +/-10 mm towards or away from the tendon. The results of this study showed that the position of the patellar tendon bar had no significant effect on the pressure distribution around the socket indicating that it is an unnecessary feature, which, we propose, may be eliminated during manufacture of a trans-tibial socket.
    Matched MeSH terms: Prosthesis Design*
  13. Devnani AS
    Singapore Med J, 2000 Nov;41(11):534-7.
    PMID: 11284611
    To describe an appliance used for equalisation of severe congenital lower limb length discrepancy for patients who refuse to undergo any operative correction but wish to walk and look better.
    Matched MeSH terms: Prosthesis Design
  14. Abdelbasit MA, Alwi M, Kandavello G, Che Mood M, Samion H, Hijazi ZM
    Catheter Cardiovasc Interv, 2015 Jul;86(1):94-9.
    PMID: 25675888 DOI: 10.1002/ccd.25878
    OBJECTIVES: To evaluate the feasibility, safety, and efficacy of the Occlutech® PDA occluder for closure of patent ductus arteriosus (PDA).

    BACKGROUND: The Occlutech® PDA occluder is novel, self-shaping Nitinol wire device with PET (polyethylene terephthalate) patches integrated into the shank of the device to assure a better obturation of the ductus. The Occlutech® PDA occluder has undergone two design modifications.

    METHODS: A prospective, non-randomized pilot study was started in November 2011. Thirty-three patients were included until April 2013. Patients weighing <6 kg or those with associated cardiac anomalies that required surgery were excluded. All patients were followed up by transthoracic echocardiography at 24 hr, 30 days, 90 days, 180 days, and 360 days after implantation. Residual shunt, left pulmonary artery (LPA) and descending aortic velocities were among the parameters assessed. All occluders were delivered via 6-8 F long sheaths and PDA closures were performed following standard techniques.

    RESULTS: Thirty three patients (20 female/13 male), with a median age of 2 years (6 month to 38 years), and median weight of 9.3 kg (6-69.2 kg) were included. The narrowest median PDA diameter was 3mm (1.8-5.8 mm). All the 33 patients were closed successfully using Occlutech ductal occluder, 16 patients (48.4%) had immediate and complete closure on angiography. Within 24 hr, color Doppler revealed complete closure in 27patients (81.8%), 32patients (97%) at 30 days, and in 100% of patients at 90 days. All patients with a large PDA had immediate residual shunt which was closed at the 90-day follow-up. There was no device embolization, hemolysis, or obstruction to the LPA or descending aorta.

    CONCLUSION: The new Occlutech® PDA is safe and effective. In patients with a large PDA complete closure tended to take longer time.

    Matched MeSH terms: Prosthesis Design
  15. Gholizadeh H, Lemaire ED, Eshraghi A
    Clin Biomech (Bristol, Avon), 2016 08;37:108-116.
    PMID: 27423025 DOI: 10.1016/j.clinbiomech.2016.06.005
    BACKGROUND: An optimal suspension system can improve comfort and quality of life in people with limb loss. To guide practice on prosthetic vacuum suspension systems, assessment of the current evidence and professional opinion are required.

    METHODS: PubMed, Web of Science, and Google Scholar databases were explored to find related articles. Search terms were amputees, artificial limb, prosthetic suspension, prosthetic liner, vacuum, and prosthesis. The results were refined by vacuum socket or vacuum assisted suspension or sub-atmospheric suspension. Study design, research instrument, sample size, and outcome measures were reviewed. An online questionnaire was also designed and distributed worldwide among professionals and prosthetists (www.ispoint.org, OANDP-L, LinkedIn, personal email).

    FINDINGS: 26 articles were published from 2001 to March 2016. The number of participants averaged 7 (SD=4) for transtibial and 6 (SD=6) for transfemoral amputees. Most studies evaluated the short-term effects of vacuum systems by measuring stump volume changes, gait parameters, pistoning, interface pressures, satisfaction, balance, and wound healing. 155 professionals replied to the questionnaire and supported results from the literature. Elevated vacuum systems may have some advantages over the other suspension systems, but may not be appropriate for all people with limb loss.

    INTERPRETATION: Elevated vacuum suspension could improve comfort and quality of life for people with limb loss. However, future investigations with larger sample sizes are needed to provide strong statistical conclusions and to evaluate long-term effects of these systems.

    Matched MeSH terms: Prosthesis Design*
  16. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S
    PLoS One, 2014;9(5):e94520.
    PMID: 24827560 DOI: 10.1371/journal.pone.0094520
    The suction sockets that are commonly prescribed for transtibial amputees are believed to provide a better suspension than the pin/lock systems. Nevertheless, their effect on amputees' gait performance has not yet been fully investigated. The main intention of this study was to understand the potential effects of the Seal-in (suction) and the Dermo (pin/lock) suspension systems on amputees' gait performance.
    Matched MeSH terms: Prosthesis Design/instrumentation; Prosthesis Design/psychology*
  17. Arifin N, Abu Osman NA, Ali S, Wan Abas WA
    Biomed Eng Online, 2014;13(1):23.
    PMID: 24597518 DOI: 10.1186/1475-925X-13-23
    Achieving independent upright posture has known to be one of the main goals in rehabilitation following lower limb amputation. The purpose of this study was to compare postural steadiness of below knee amputees with visual alterations while wearing three different prosthetic feet.
    Matched MeSH terms: Prosthesis Design
  18. Ali S, Osman NA, Razak A, Hussain S, Wan Abas WA
    Eur J Phys Rehabil Med, 2015 Feb;51(1):31-7.
    PMID: 24963603
    Lower limb amputee's are greatly affected in dealing with the environmental barriers such as ramps and stairs and reported high interface pressure between the residual limb and socket/liner. Interface pressure between the residual limb and socket/liner can affect the satisfaction and use of the prosthesis. Until now, little attention has been paid to interface pressure between socket and stump during ramp negotiation and its effect on amputee's satisfaction.
    Matched MeSH terms: Prosthesis Design*
  19. Nurhanisah MH, Jawaid M, Ahmad Azmeer R, Paridah MT
    Disabil Rehabil Assist Technol, 2019 07;14(5):513-520.
    PMID: 29933703 DOI: 10.1080/17483107.2018.1479782
    This study describes a newly developed prosthetic leg socket design for a below-knee amputation. Excessive heat and the resulted perspiration within a prosthetic socket were the most common causes for reporting a reduced quality of life for prosthetic users. The product namely AirCirc means air circulation and it has been designed by approach of medical device design process in providing the amputees to maintain the skin temperature inside the socket. This device has been designed to provide the amputees with comfort and ultimate breathable. In order to design the device, the small hole was made in prosthetic socket surface since it has a function as air circulation. Four types of proposed sockets namely P1, P2, P3 and P4 and one control socket were compared on a single patient to determine the best design of prosthetic socket. The result successfully reveals that by using holes can be maintain the temperature inside prosthetic socket. In addition to the eco-friendly material, the woven kenaf was used as material that provides good strength as compared to glass fibre and offer sustainable and biodegradable product yet provides unique and aesthetic surface as came from woven kenaf itself. The objective of this paper is to provide the airflow prosthetic socket design and optimize the use of natural fibre in prostheses field. Thus, with the use of the environmental friendly material, functionality device and heat removal capability make the device suitable for maintaining a comfortable and healthy environment for prosthesis. Implications of Rehabilitation Newly developed prosthetic leg socket design for a below-knee amputation Device has been designed to provide the amputees with comfort and ultimate breathable Woven kenaf was used as material that provides good strength as compared to glass fibre for sustainable and biodegradable product Results show that by using holes can be maintain the temperature inside prosthetic socket.
    Matched MeSH terms: Prosthesis Design*