Displaying publications 1 - 20 of 31 in total

Abstract:
Sort:
  1. Kwan MK, Penafort R, Saw A
    Med J Malaysia, 2004 Dec;59 Suppl F:39-41.
    PMID: 15941159
    Joint stiffness is one of the complications of limb procedure. It developes as a result of failure of knee flexors to lengthen in tandem with the bone, especially when there is inadequate physical therapy to provide active and passive mobilization of the affected joint. We are reporting four patients who developed fixed flexion contracture of their knees during bone lengthening procedure for the tibia with Ilizarov external fixator. Three of them were treated for congenital pseudoarthrosis and one was for fibular hemimelia. None of them were able to visit the physiotherapist even on a weekly basis. A splint was constructed from components of Ilizarov external fixator and applied on to the existing frame to passively extend the affected knee. Patients and their family members were taught to perform this exercise regularly and eventually near complete correction were achieved. With this result, we would like to recommend the use of this "Passive Knee Extension Splint" to avoid knee flexion Contracture during limb lengthening procedures with Ilizarov external fixators.
    Matched MeSH terms: Range of Motion, Articular/physiology
  2. Sheykhi-Dolagh R, Saeedi H, Farahmand B, Kamyab M, Kamali M, Gholizadeh H, et al.
    Prosthet Orthot Int, 2015 Jun;39(3):190-6.
    PMID: 24604086 DOI: 10.1177/0309364614521652
    BACKGROUND: Flexible flat foot is described as a reduction in the height of the medial longitudinal arch and may occur from abnormal foot pronation. A foot orthosis is thought to modify and control excessive pronation and improve arch height.
    OBJECTIVE: To compare the immediate effect of three types of orthoses on foot mobility and the arch height index in subjects with flexible flat feet.
    STUDY DESIGN: A quasi-experimental study.
    METHOD: The dorsal arch height, midfoot width, foot mobility and arch height index were assessed in 20 participants with flexible flat feet (mean age = 23.2 ± 3 years) for three different foot orthosis conditions: soft, semi-rigid and rigid University of California Biomechanics Laboratory (UCBL).
    RESULTS: Maximum midfoot width at 90% with arch mobility in the coronal plane was shown in the semi-rigid orthosis condition. The semi-rigid orthosis resulted in the highest mean foot mobility in 90% of weight bearing, and the rigid orthosis (UCBL) had the lowest mean foot mobility. The soft orthosis resulted in foot mobility between that of the rigid and the semi-rigid orthosis. UCBL orthosis showed the highest arch height index, and the semi-rigid orthosis showed the lowest mean arch height index.
    CONCLUSION: Due to its rigid structure and long medial-lateral walls, the UCBL orthosis appears to limit foot mobility. Therefore, it is necessary to make an orthosis that facilitates foot mobility in the normal range of the foot arch. Future studies should address the dynamic mobility of the foot with using various types of foot orthoses.
    CLINICAL RELEVANCE: Although there are many studies focussed on flat foot and the use of foot orthoses, the mechanism of action is still unclear. This study explored foot mobility and the influence of foot orthoses and showed that a more rigid foot orthosis should be selected based on foot mobility.
    KEYWORDS: Foot orthosis; arch height index; foot mobility magnitude
    Matched MeSH terms: Range of Motion, Articular/physiology*
  3. Chan CY, Kwan MK, Saravanan S, Saw LB, Deepak AS
    Med J Malaysia, 2007 Mar;62(1):33-5.
    PMID: 17682567 MyJurnal
    Assessment of the curve flexibility is a crucial step in a surgeon's pre-operative planning for scoliosis surgery. Many techniques have been described. These include traction films, supine side bending films, push prone techniques, traction under general anaesthesia as well as fulcrum bending film. In this study, we studied the pre- and immediate post-operative radiographs of twenty eight adolescent idiopathic scoliosis (AIS) patients who were corrected using pedicle screw systems between January 2004 and August 2006. There were twenty two females and six male patients. The mean age of the patients were 17.5 years with a range of 12 to 38 years. Skeletal maturity of the patients was assessed by Risser's score. The majority was Risser 4 (15 cases, 53.6%). Based on King and Moe's classification, the most common curve was type 3 curve (15 cases, 53.6%). Among the twenty eight patients, twenty three patients underwent only posterior correction, while 5 patients underwent additional anterior release surgery. The mean pre-operative Cobb's angle for the posterior surgery group was 65.5 +/- 13.9 degrees and the mean post-operative Cobb's angle was 32.9 +/- 12.6 degrees. There was no difference between the mean correction estimated by fulcrum bending films (Fulcrum Flexibility) and the post- operative Correction Rate figures (44.2% vs. 49.9%). The mean Fulcrum Bending Correction Index (FBCI) in this group of patients is 112.8%. In the group of patients who underwent additional anterior release, their curves were noted to be larger and less flexible with the mean pre-operative Cobb's angle and Fulcrum Flexibility of 90.4 degrees +/- 9.3 degrees and 23.4% respectively. The Fulcrum Bending Correction Index (FBCI) for this group of patients was significantly higher than the posterior surgery group: i.e. 164.0% vs 112.8%. Thus, anterior release does help to improve the correction significantly. The fulcrum bending films give good pre-operative estimation of the amount of correction to be expected post-operatively. The fulcrum bending films can help to identify the curve types which might require anterior release in order to improve the scoliosis correction. Using the Fulcrum Bending Correction Index (FBCI) will also enable surgeons to quantify more accurately the amount of correction achieved by taking into account the inherent flexibility of the spine.
    Matched MeSH terms: Range of Motion, Articular/physiology*
  4. Masni-Azian, Tanaka M
    Comput Methods Biomech Biomed Engin, 2017 Aug;20(10):1066-1076.
    PMID: 28532164 DOI: 10.1080/10255842.2017.1331345
    In the biomechanics field, material parameters calibration is significant for finite element (FE) model to ensure a legit estimation of biomechanical response. Determining an appropriate combination of calibration factors is challenging as each constitutive component responds differently. This study proposes a statistical factorial analysis approach using L16(4(5)) orthogonal array to evaluate material nonlinearity and applicable calibration factor of the intervertebral disc FE model in pure moment. The calibrated model exhibits improved agreement to the experimental findings for all directions. Appropriate combination of calibration parameter reduces the estimation gap to the experimental findings, ensuring agreeable biomechanical responses.
    Matched MeSH terms: Range of Motion, Articular/physiology
  5. Abd Razak NA, Abu Osman NA, Kamyab M, Wan Abas WA, Gholizadeh H
    Am J Phys Med Rehabil, 2014 May;93(5):437-44.
    PMID: 24429510 DOI: 10.1097/PHM.0b013e3182a51fc2
    This report compares wrist supination and pronation and flexion and extension movements with the common body-powered prosthesis and a new biomechatronics prosthesis with regard to patient satisfaction and problems experienced with the prosthesis. Fifteen subjects with traumatic transradial amputation who used both prosthetic systems participated in this study. Each subject completed two questionnaires to evaluate their satisfaction and problems experienced with the two prosthetic systems. Satisfaction and problems with the prosthetic's wrist movements were analyzed in terms of the following: supination and pronation; flexion and extension; appearance; sweating; wounds; pain; irritation; pistoning; smell; sound; durability; and the abilities to open a door, hold a cup, and pick up or place objects. This study revealed that the respondents were more satisfied with the biomechatronics wrist prosthesis with regard to supination and pronation, flexion and extension, pain, and the ability to open a door. However, satisfaction with the prosthesis showed no significant differences in terms of sweating, wounds, irritation, pistoning, smell, sound, and durability. The abilities to hold a cup and pick up or place an object were significantly better with the body-powered prosthesis. The results of the survey suggest that satisfaction and problems with wrist movements in persons with transradial amputation can be improved with a biomechatronics wrist prosthesis compared with the common body-powered prosthesis.
    Matched MeSH terms: Range of Motion, Articular/physiology*
  6. Arif M, Sivananthan S, Choon DS
    J Orthop Surg (Hong Kong), 2004 Jun;12(1):25-30.
    PMID: 15237118
    To report the outcome of revised total hip arthroplasty procedures involving an anterior cortical window, extensive strut allografts, and an Exeter impaction graft.
    Matched MeSH terms: Range of Motion, Articular/physiology
  7. Bashaireh KM, Yabroudi MA, Nawasreh ZH, Al-Zyoud SM, Bashir NB, Aleshawi AJ, et al.
    Knee, 2020 Aug;27(4):1205-1211.
    PMID: 32711883 DOI: 10.1016/j.knee.2020.05.003
    BACKGROUND: A high incidence of joint laxity has been reported among Asians compared with Western populations, but clear differences between more specific ethnic populations have not been established. This study aimed to determine the average knee laxity in the Malaysian and Jordanian populations.

    METHODS: Jordanian and Malaysian medical students from our institution were invited to participate in the study. General demographic data and factors affecting joint laxity were obtained from each participant using a printed questionnaire. Both knees were examined using the anterior drawer test while in 90° of flexion. Knee laxity was measured by three separate independent investigators through a knee laxity tester.

    RESULTS: One hundred and eighty-six participants (95 females) were enrolled in the study. Among them, 108 Malaysians participated. The Jordanians had significantly higher knee laxity in both knees compared with the Malaysians. The mean average right knee laxity for Jordanians was 2.98 mm vs. 2.72 mm for Malaysians (P = 0.005). Similarly, the mean average left knee laxity for Jordanians was 2.95 mm, while for Malaysians, it was 2.62 mm (P = 0.0001). Furthermore, smokers had significantly more laxity in both knees. After performing a multivariate linear regression analysis for all factors, race was the only independent factor that affected knee laxity in both knees.

    CONCLUSIONS: Race is directly associated with knee laxity. Jordanians tend to have more laxity in knee joints compared with Malaysians. Larger multi-center and genetic studies are recommended to establish the racial differences between different ethnic groups.

    Matched MeSH terms: Range of Motion, Articular/physiology*
  8. Mat Eil Ismail MS, Sharifudin MA, Shokri AA, Ab Rahman S
    Singapore Med J, 2016 Mar;57(3):138-43.
    PMID: 26996450 DOI: 10.11622/smedj.2016055
    INTRODUCTION: Physiotherapy is an important part of rehabilitation following arthroplasty, but the impact of preoperative physiotherapy on functional outcomes is still being studied. This randomised controlled trial evaluated the effect of preoperative physiotherapy on the short-term functional outcomes of primary total knee arthroplasty (TKA).
    METHODS: 50 patients with primary knee osteoarthritis who underwent unilateral primary TKA were randomised into two groups: the physiotherapy group (n = 24), whose patients performed physical exercises for six weeks immediately prior to surgery, and the nonphysiotherapy group (n = 26). All patients went through a similar physiotherapy regime in the postoperative rehabilitation period. Functional outcome assessment using the algofunctional Knee Injury and Osteoarthritis Outcome Score (KOOS) scale and range of motion (ROM) evaluation was performed preoperatively, and postoperatively at six weeks and three months.
    RESULTS: Both groups showed a significant difference in all algofunctional KOOS subscales (p < 0.001). The mean score difference at six weeks and three months was not significant in the sports and recreational activities subscale for both groups (p > 0.05). Significant differences were observed in the time-versus-treatment analysis between groups for the symptoms (p = 0.003) and activities of daily living (p = 0.025) subscales. No significant difference in ROM was found when comparing preoperative measurements and those at three months following surgery, as well as in time-versus-treatment analysis (p = 0.928).
    CONCLUSION: Six-week preoperative physiotherapy showed no significant impact on short-term functional outcomes (KOOS subscales) and ROM of the knee following primary TKA.
    KEYWORDS: algofunctional Knee Injury and Osteoarthritis Outcome Score; functional outcome; prehabilitation; preoperative physiotherapy; total knee arthroplasty
    Matched MeSH terms: Range of Motion, Articular/physiology*
  9. Makinejad MD, Abu Osman NA, Abu Bakar Wan Abas W, Bayat M
    Clinics (Sao Paulo), 2013 Sep;68(9):1180-8.
    PMID: 24141832 DOI: 10.6061/clinics/2013(09)02
    This study provides an experimental and finite element analysis of knee-joint structure during extended-knee landing based on the extracted impact force, and it numerically identifies the contact pressure, stress distribution and possibility of bone-to-bone contact when a subject lands from a safe height.
    Matched MeSH terms: Range of Motion, Articular/physiology
  10. Haflah NH, Jaarin K, Abdullah S, Omar M
    Saudi Med J, 2009 Nov;30(11):1432-8.
    PMID: 19882056
    OBJECTIVE: To assess the efficacy of oral palm vitamin E in reducing symptoms of patients with osteoarthritis (OA) of the knee compared to oral glucosamine sulphate.
    METHODS: This open study was carried out at the Universiti Kebangsaan Malaysia Medical Center, Kuala Lumpur, Malaysia between March 2006 and November 2007. Seventy-nine patients were recruited to receive either 1.5 g oral glucosamine sulphate or 400 mg oral palm vitamin E for 6 months. Symptoms were assessed using the Western Ontario and McMaster Universities (WOMAC) osteoarthritis index and visual analogue scale (VAS).
    RESULTS: Sixty-four patients completed the trial (vitamin E n=33, glucosamine sulfate n=31). After 6 months of treatment, both groups showed a significant improvement in WOMAC scale and significant reduction in the VAS score during standing and walking. There was no significant difference in WOMAC scale and VAS score between the 2 groups. Except for mild allergic reaction and abdominal discomfort in one patient, there were no other serious adverse effects reported. Serum malondialdehyde was significantly higher in the glucosamine group compared to palm vitamin E treated group at the end of the study. Serum of vitamin E was significantly higher in the palm vitamin E group compared to glucosamine.
    CONCLUSION: The finding of this study suggests that oral palm vitamin E in a dose of 400 mg taken daily has a potential role in reducing symptoms of patients with OA of the knee. It may be just as effective as glucosamine sulphate in reducing the symptoms and free from serious side effects. Further study is required to ascertain the mechanism of action beside its antioxidant effect.
    Matched MeSH terms: Range of Motion, Articular/physiology
  11. Devnani AS
    Singapore Med J, 2004 Jan;45(1):14-9.
    PMID: 14976577
    To study the long term result of open reduction of longstanding dislocated elbows with regard to stability, avascular necrosis of the distal humerus and degenerative changes of the joint.
    Matched MeSH terms: Range of Motion, Articular/physiology
  12. Ajit Singh V, Earnest Kunasingh D, Haseeb A, Yasin NF
    J Orthop Surg (Hong Kong), 2019 5 30;27(2):2309499019850313.
    PMID: 31138060 DOI: 10.1177/2309499019850313
    PURPOSE: Expandable endoprosthesis allows limb salvage in children with an option to leading a better life. However, the revision rate and implant-related complications impose as a limitation in the skeletal immature. This study investigates the functional outcomes and complications related to expandable endoprosthesis in our centre.

    MATERIALS AND METHODS: Twenty surviving patients with expandable endoprosthesis from 2006 till 2015 were scored using Musculoskeletal Tumour Society (MSTS) outcomes instrument and reviewed retrospectively for range of motion of respected joints, limb length discrepancy, number of surgeries performed, complications and oncological outcomes. Patients with less than 2 years of follow-up were excluded from this study.

    RESULTS: Forty-five percentage patients reached skeletal maturity with initial growing endoprosthesis and 25% of patients were revised to adult modular prosthesis. One hundred fifty-seven surgeries were performed over the 9-year period. The average MSTS score was 90.83%. The mortality rate was 10% within 5 years due to advanced disease. Infection and implant failure rate was 15% each. The event-free survival was 50% and overall survival rate was 90%.

    CONCLUSION: There is no single best option for reconstruction in skeletally immature. This study demonstrates a favourable functional and survival outcome of paediatric patients with expandable endoprosthesis. The excellent MSTS functional scores reflect that patients were satisfied and adjusted well to activities of daily living following surgery despite the complications.

    Matched MeSH terms: Range of Motion, Articular/physiology*
  13. Wahab AH, Kadir MR, Harun MN, Kamarul T, Syahrom A
    Med Biol Eng Comput, 2017 Mar;55(3):439-447.
    PMID: 27255451 DOI: 10.1007/s11517-016-1525-6
    The present study was conducted to compare the stability of four commercially available implants by investigating the focal stress distributions and relative micromotion using finite element analysis. Variations in the numbers of pegs between the implant designs were tested. A load of 750 N was applied at three different glenoid positions (SA: superior-anterior; SP: superior-posterior; C: central) to mimic off-center and central loadings during activities of daily living. Focal stress distributions and relative micromotion were measured using Marc Mentat software. The results demonstrated that by increasing the number of pegs from two to five, the total focal stress volumes exceeding 5 MPa, reflecting the stress critical volume (SCV) as the threshold for occurrence of cement microfractures, decreased from 8.41 to 5.21 % in the SA position and from 9.59 to 6.69 % in the SP position. However, in the C position, this change in peg number increased the SCV from 1.37 to 5.86 %. Meanwhile, micromotion appeared to remain within 19-25 µm irrespective of the number of pegs used. In conclusion, four-peg glenoid implants provide the best configuration because they had lower SCV values compared with lesser-peg implants, preserved more bone stock, and reduced PMMA cement usage compared with five-peg implants.
    Matched MeSH terms: Range of Motion, Articular/physiology*
  14. Islam MA, Sundaraj K, Ahmad RB, Sundaraj S, Ahamed NU, Ali MA
    PLoS One, 2014;9(8):e104280.
    PMID: 25090008 DOI: 10.1371/journal.pone.0104280
    In mechanomyography (MMG), crosstalk refers to the contamination of the signal from the muscle of interest by the signal from another muscle or muscle group that is in close proximity.
    Matched MeSH terms: Range of Motion, Articular/physiology
  15. Yeap JS, Birch R, Singh D
    Int Orthop, 2001;25(2):114-8.
    PMID: 11409449
    Twelve patients with drop-foot secondary to sciatic or common peroneal nerve palsy treated with transfer of the tibialis posterior tendon were followed-up for a mean of 90 (24-300) months. In 10 patients the results were 'excellent' or 'good'. In 11 patients grade 4 or 5 power of dorsiflexion was achieved, although the torque, as measured with a Cybex II dynamometer, and generated by the transferred tendon, was only about 30% of the normal side. Seven patients were able to dorsiflex their foot to the neutral position and beyond. The results appeared to be better in men under 30 years of age with common peroneal palsies. A painful flatfoot acquired in adulthood does not appear to be a significant long-term complication despite the loss of a functioning tibialis posterior tendon.
    Matched MeSH terms: Range of Motion, Articular/physiology
  16. Abd Razak NA, Abu Osman NA, Wan Abas WA
    Disabil Rehabil Assist Technol, 2013 May;8(3):255-60.
    PMID: 22830946 DOI: 10.3109/17483107.2012.704654
    This study examined the kinematic differences between a body-powered prosthesis and a biomechatronics prosthesis as a transradial amputee performed activities that involve flexion/extension and supination/pronation of the wrist.
    Matched MeSH terms: Range of Motion, Articular/physiology*
  17. Bajuri MY, Maidin S, Rauf A, Baharuddin M, Harjeet S
    Clinics (Sao Paulo), 2011;66(4):635-9.
    PMID: 21655759
    OBJECTIVE: The main aim of the study was to analyze the outcomes of clavicle fractures in adults treated non-surgically and to evaluate the clinical effects of displacement, fracture patterns, fracture location, fracture comminution, shortening and fracture union on shoulder function.

    METHODS: Seventy clavicle fractures were non-surgically treated in the Orthopedics Department at the Tuanku Ja'afar General Hospital, a tertiary care hospital in Seremban, Malaysia, an average of six months after injury. The clavicle fractures were treated conservatively with an arm sling and a figure-eight splint for three weeks. No attempt was made to reduce displaced fractures, and the patients were allowed immediate free-shoulder mobilization, as tolerated. They were prospectively evaluated clinically and radiographically. Shoulder function was evaluated using the Constant scoring technique.

    RESULTS: There were statistically significant functional outcome impairments in non-surgically treated clavicle fractures that correlated with the fracture type (comminution), the fracture displacement (21 mm or more), shortening (15 mm or more) and the fracture union (malunion).

    CONCLUSION: This article reveals the need for surgical intervention to treat clavicle fractures and improve shoulder functional outcomes.

    Matched MeSH terms: Range of Motion, Articular/physiology*
  18. Ling XF, Peng X, Samman N
    J Oral Maxillofac Surg, 2013 Sep;71(9):1604-12.
    PMID: 23810616 DOI: 10.1016/j.joms.2013.03.006
    This study evaluated and compared the long-term donor-site morbidity of the free fibula flap with the deep circumflex iliac artery (DCIA) flap in maxillofacial reconstruction.
    Matched MeSH terms: Range of Motion, Articular/physiology
  19. Chan SC, Patrick Engkasan J
    Int J Rheum Dis, 2020 Dec;23(12):1741-1743.
    PMID: 33118670 DOI: 10.1111/1756-185X.13948
    Matched MeSH terms: Range of Motion, Articular/physiology*
  20. Chiu CK, Lisitha KA, Elias DM, Yong VW, Chan CYW, Kwan MK
    J Orthop Surg (Hong Kong), 2018 10 26;26(3):2309499018806700.
    PMID: 30352524 DOI: 10.1177/2309499018806700
    BACKGROUND: This prospective clinical-radiological study was conducted to determine whether the dynamic mobility stress radiographs can predict the postoperative vertebral height restoration, kyphosis correction, and cement volume injected after vertebroplasty.

    METHODS: Patients included had the diagnosis of significant back pain caused by osteoporotic vertebral compression fracture secondary to trivial injury. All the patients underwent routine preoperative sitting lateral spine radiograph, supine stress lateral spine radiograph, and supine anteroposterior spine radiograph. The radiological parameters recorded were anterior vertebral height (AVH), middle vertebral height (MVH), posterior vertebral height (PVH), MVH level below, wedge endplate angle (WEPA), and regional kyphotic angle (RKA). The supine stress versus sitting difference (SSD) for all the above parameters were calculated.

    RESULTS: A total of 28 patients (4 males; 24 females) with the mean age of 75.6 ± 7.7 years were recruited into this study. The mean cement volume injected was 5.5 ± 1.8 ml. There was no difference between supine stress and postoperative radiographs for AVH ( p = 0.507), PVH ( p = 0.913) and WEPA ( p = 0.379). The MVH ( p = 0.026) and RKA ( p = 0.005) were significantly less in the supine stress radiographs compared to postoperative radiographs. There was significant correlation ( p < 0.05) between supine stress and postoperative AVH, MVH, PVH, WEPA, and RKA. The SSD for AVH, PVH, WEPA, and RKA did not have significant correlation with the cement volume ( p > 0.05). Only the SSD-MVH had significant correlation with cement volume, but the correlation was weak ( r = 0.39, p = 0.04).

    CONCLUSIONS: Dynamic mobility stress radiographs can predict the postoperative vertebral height restoration and kyphosis correction after vertebroplasty for thoracolumbar osteoporotic fracture with intravertebral clefts. However, it did not reliably predict the amount of cement volume injected as it was affected by other factors.

    Matched MeSH terms: Range of Motion, Articular/physiology
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links