Displaying publications 1 - 20 of 67 in total

Abstract:
Sort:
  1. Lewthwaite P, Shankar MV, Tio PH, Daly J, Last A, Ravikumar R, et al.
    Trop Med Int Health, 2010 Jul;15(7):811-8.
    PMID: 20487425 DOI: 10.1111/j.1365-3156.2010.02537.x
    OBJECTIVE: To compare two commercially available kits, Japanese Encephalitis-Dengue IgM Combo ELISA (Panbio Diagnostics) and JEV-CheX IgM capture ELISA (XCyton Diagnostics Limited), to a reference standard (Universiti Malaysia Sarawak - Venture Technologies VT ELISA).

    METHODS: Samples were obtained from 172/192 children presenting to a site in rural India with acute encephalitis syndrome.

    RESULTS: Using the reference VT ELISA, infection with Japanese encephalitis virus (JEV) was confirmed in 44 (26%) patients, with central nervous system infection confirmed in 27 of these; seven patients were dengue seropositive. Of the 121 remaining patients, 37 (31%) were JEV negative and 84 (69%) were JEV unknown because timing of the last sample tested was <10 day of illness or unknown. For patient classification with XCyton, using cerebrospinal fluid alone (the recommended sample), sensitivity was 77.8% (59.2-89.4) with specificity of 97.3% (90.6-99.2). For Panbio ELISA, using serum alone (the recommended sample), sensitivity was 72.5% (57.2-83.9) with specificity of 97.5% (92.8-99.1). Using all available samples for patient classification, sensitivity and specificity were 63.6% (95% CI: 48.9-76.2) and 98.4% (94.5-99.6), respectively, for XCyton ELISA and 75.0% (59.3-85.4) and 97.7% (93.3-99.2) for Panbio ELISA.

    CONCLUSION: The two commercially available ELISAs had reasonable sensitivities and excellent specificities for diagnosing JEV.

    Matched MeSH terms: Reagent Kits, Diagnostic
  2. Jamail M, Andrew K, Junaidi D, Krishnan AK, Faizal M, Rahmah N
    Trop Med Int Health, 2005 Jan;10(1):99-104.
    PMID: 15655019
    We conducted a field study of a rapid test (Brugia Rapid) for detection of Brugia malayi infection to validate its sensitivity and specificity under operational conditions. Seven districts in the state of Sarawak, Malaysia, which are endemic for brugian filariasis, were used to determine the test sensitivity. Determination of specificity was performed in another state in Malaysia (Bachok, Kelantan) which is non-endemic for filariasis but endemic for soil-transmitted helminths. In Sarawak both the rapid test and thick blood smear preparation were performed in the field. The rapid test was interpreted on site, whereas blood smears were taken to the district health centres for staining and microscopic examination. Sensitivity of Brugia Rapid dipstick as compared with microscopy of thick blood smears was 87% (20/23; 95% CI: 66.4-97.2) whereas the specificity was 100% (512/512). The lower sensitivity of the test in the field than in laboratory evaluations (> or =95%), was probably due to the small number of microfilaraemic individuals, in addition to difficulties in performing the test in remote villages by field personnel. The overall prevalence of brugian filariasis as determined by the dipstick is 9.4% (95% CI: 8.2-0.5) while that determined by microscopy is 0.90% (95% CI: 0.5-1.3) thus the dipstick detected about 10 times more cases than microscopy. Equal percentages of adults and children were found to be positive by the dipstick whereas microscopy showed that the number of infected children was seven times less than infected adults. The rapid dipstick test was useful as a diagnostic tool for mapping and certification phases of the lymphatic filariasis elimination programme in B. malayi-endemic areas.
    Matched MeSH terms: Reagent Kits, Diagnostic
  3. Rahmah N, Shenoy RK, Nutman TB, Weiss N, Gilmour K, Maizels RM, et al.
    Trop Med Int Health, 2003 Oct;8(10):895-900.
    PMID: 14516300
    A multicentre evaluation of the Brugia Rapid dipstick test was performed using 1263 serum samples in four international laboratories, i.e. T.D. Medical College (TDMC, India), National Institutes of Health (NIH, USA), Swiss Tropical Institute (STI, Switzerland) and Leiden University Medical Centre (LUMC, Netherlands). In comparison with microscopy, the dipstick demonstrated sensitivities of 97.2% (70 of 72) at TDMC, 91.6% (175 of 191) at LUMC and 100% (six of six) at STI. Sera of chronic patients showed a positivity rate of 11.3% (19 of 168) and 61.2% (71of 116) at TDMC and LUMC, respectively. All 266 sera of non-endemic normals from STI, NIH and LUMC tested negative with the dipstick. At LUMC, sera of 'endemic normals' (amicrofilaraemics with no clinical disease) from an area with approximately 35% microfilaria positivity showed 60.8% positive results (31 of 51), thus demonstrating the likelihood of many cryptic infections occurring in this population. Specificities of the test with Onchocerca volvulus sera were 98.8% (80 of 81) and 100% (10 of 10) at the NIH and STI, respectively; while specificity with Loa loa sera at the NIH was 84.6% (44 of 52). At the STI, the dipstick test also demonstrated 100% specificity when tested with 75 sera from various protozoan and helminthic infections.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  4. Ng KL, Lee EL, Sani RA
    Trop Biomed, 2012 Mar;29(1):187-90.
    PMID: 22543620 MyJurnal
    This study was conducted to investigate the low prevalence of Dirofilaria immitis in dogs in Johor Bahru as reported by veterinary practitioners, using wet blood mount, Knott's Concentration Test and two heartworm antigen test kits (IDEXX Canine SNAP® 4Dx and RapiGEN®). This study also compared the two test kits used and determined the microfilaria species. Blood were collected from 100 owned dogs and 50 stray dogs in Johor Bahru via cephalic venipuncture. A thick blood smear was done and examined for samples that were positive for microfilaria species identification. The overall prevalence of D. immitis in dogs in Johor Bahru was 1.33% (2/150) and the microfilaria identified was D. immitis. The prevalence of heartworm in owned and stray dogs in this study was 1% and 2% respectively. With only one false negative result from RapiGEN® test kit, comparing the sensitivity between the two test kits could not be achieved. The low prevalence of D. immitis found in this study confirmed anecdotal evidence that prevalence of dirofilariasis is indeed low in Johor Bahru. Additionally, we speculate that dirofilariasis in dogs might be considered as an indicator of vector availability.
    Matched MeSH terms: Reagent Kits, Diagnostic
  5. Lee SV, Tai ES, Mutalib AR, Khairani-Bejo S, Bahaman AR
    Trop Biomed, 2011 Dec;28(3):497-505.
    PMID: 22433877 MyJurnal
    A simple and reliable tool for the early diagnosis of leptospirosis is urgently needed. We report the development of a lyophilized reagent-based polymerase chain reaction (PCR) assay targeting lipL32 gene, which is present only in pathogenic leptospires. To determine the effectiveness of the newly developed assay in the early diagnosis of leptospirosis, the sensitivity and specificity was evaluated. In simulated clinical samples, the assay was able to detect 10² and 10³ leptospires/ml in spiked urine and blood samples, respectively. In experimentally infected animals, leptospiral DNA could be detected in blood and lung samples as early as Day 1 post infection. This assay was also shown to be stable and remained sensitive for up to five months at ambient temperature. Hence, this lyophilized reagent-based PCR assay with high specificity, sensitivity and stability would provide a simple, rapid and reliable method in diagnosing acute leptospirosis, especially in the field of veterinary medicine.
    Matched MeSH terms: Reagent Kits, Diagnostic
  6. Zeehaida M, Wan Nor Amilah WA, Amry AR, Hassan S, Sarimah A, Rahmah N
    Trop Biomed, 2008 Dec;25(3):209-16.
    PMID: 19287359
    Amoebic serodiagnosis at Hospital Universiti Sains Malaysia (HUSM), Kelantan employs an indirect haemagglutination assay (IHA) which detects anti-Entamoeba histolytica antibodies in patients' serum samples. In an amoebiasis endemic area such as Kelantan, interpretation of a positive IHA result can be problematic due to the high background antibody levels. The TechLab E. histolytica II ELISA is a commercial kit for detection of specific Gal/GalNAc lectin antigen in stool samples, and has been reported to be able to detect the antigen in serum samples from patients with amoebic liver abscess (ALA). Thus in this study we investigated the usefulness of TechLab E. histolytica II ELISA for diagnosis of ALA by comparing it with IHA. This is a cross sectional study involving 58 suspected ALA patients who were admitted to the surgical ward, HUSM, Kelantan. The diagnosis of ALA was established based on clinical symptoms and signs, ultrasound and/or CT scan results. The serum specimens obtained from the patients were tested with IHA (Dade Behring Diagnostics, Marburg, Germany) and TechLab E. histolytica II ELISA (Techlab, Blacksburg, Virginia, USA) according to the manufacturers' instructions. Of the 58 patients, 72.4% (42) were positive by IHA and only 8.6% (5) were positive by the TechLab E. histolytica II ELISA. Agreement between the IHA and ELISA was poor (kappa value 0.019, p=0.691). There was also no correlation between ELISA results and IHA antibody titers. The TechLab E. histolytica II ELISA was not sensitive in detecting amoebic antigen in samples from ALA patients. In addition the results of the test did not correlate with the IHA anti-E. histolytica antibody titres. Therefore, the TechLab E. histolytica II ELISA was found not to be useful for serological diagnosis of ALA at HUSM.
    Matched MeSH terms: Reagent Kits, Diagnostic
  7. Rajan S, Shen TH, Santhanam J, Othman NH, Othman N, Hock TT
    Trop Biomed, 2007 Jun;24(1):17-22.
    PMID: 17568373
    Human papillomavirus (HPV) is well known as an etiological factor for the development of anogenital carcinomas. The aim of our study was to compare the performance of USFDA approved Hybrid II (HCII) Assay and recently introduced DR. HPV Chip Kit for the detection of HPV DNA in clinical cervical scrapings from 40 patients. HPV DNA testing was performed using the automated HCII Assay system and DR. HPV Chip Kit. Taking cytological results as gold standard, it was found that HCII was more sensitive (36.4%) than DR. HPV Chip Kit (18.2%) although specificity was 100% with the latter method. In addition, both these molecular methods had comparable negative and positive predictive values. It was concluded that both HCII and DR. HPV Chip Kit have comparable specificity. However, sensitivity for detection of HPV in clinical samples with HCII is almost double as compared to DR. HPV Chip Kit.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  8. Ooi CP, Rohani A, Zamree I, Lee HL
    Trop Biomed, 2005 Jun;22(1):73-6.
    PMID: 16880757
    The rapid detection of dengue infection in mosquito vectors is important for early warning to forestall an outbreak. Reverse Transcriptase-Polymerase Chain Reaction (RT-PCR) provides a rapid method for dengue detection in man and mosquitoes. An RT-PCR kit developed by the Medical Entomology Unit, Institute for Medical Research to detect dengue infection in mosquitoes, was tested for its shelf life at 3 storage temperatures: room temperature, refrigerator and freezer. Test kits were tested once every 3 days for kits stored at room temperature, and once every week for those stored at refrigerator and freezer temperatures. The results showed that the test kit could only be stored above its recommended storage temperature of -20 degrees C for not more than 3 days. DNA 100 bp markers in the kits appeared to be stable at the tested temperatures and were usable up to the 20th day when stored at 2 degrees C and below.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  9. Rahmah N, Taniawati S, Shenoy RK, Lim BH, Kumaraswami V, Anuar AK, et al.
    Trans R Soc Trop Med Hyg, 2002 1 31;95(6):601-4.
    PMID: 11816429
    A total of 753 serum samples from 6 institutions in 3 countries (Malaysia, Indonesia and India) were used to evaluate an immunochromatographic rapid dipstick test, Brugia Rapid, for diagnosis of Brugia malayi infection. The samples comprised sera from 207 microfilaria-positive individuals and 546 individuals from filaria non-endemic areas. The latter consisted of 70 individuals with soil-transmitted helminth infections, 68 with other helminth infections, 238 with protozoan infections, 12 with bacterial and viral infections and 158 healthy individuals. The dipstick is prepared with a goat anti-mouse antibody control line and a B. malayi recombinant-antigen test line. First, the dipstick is dipped into a well containing diluted patient serum, thus allowing specific anti-filarial antibody in the serum to react with the recombinant antigen. Then the dipstick is placed into an adjacent well containing reconstituted anti-human IgG4-gold. After 10 min, development of 2 red-purplish lines denotes a positive result and one line indicates a negative reaction. The overall results of the evaluation showed 97% sensitivity, 99% specificity, 97% positive predictive value and 99% negative predictive value. Brugia Rapid is thus a promising diagnostic tool for detection of B. malayi infection, and would be especially useful for the brugian filariasis elimination programme.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  10. Arifin N, Basuni M, Lan CA, Yahya AR, Noordin R
    Protein J, 2010 Oct;29(7):509-15.
    PMID: 20845068 DOI: 10.1007/s10930-010-9281-1
    This paper describes a refinement in the purification step that facilitated the downstream recovery of high purity BmR1 recombinant protein, which is a protein used as a test reagent in the commercialized rapid tests for detection of lymphac filariasis i.e. Brugia Rapid™ and panLF rapid™. Purification was performed by immobilized metal affinity chromatography (IMAC), followed by ion exchange chromatography (IEX). Results showed that a total of 10.27 mg of BmR1 was obtained when IMAC was performed using 20 mM of imidazole and 5 column volume of wash buffer containing 500 mM of NaCl. Purity of the target protein was enhanced when buffer at pH 5.8 was used during the IEX. Two proteins that recurrently appeared below the BmR1 recombinant protein were identified by mass-spectrometry analysis as the same protein, thus they were probably degradation products of BmR1. These strategies improve purity of the target protein to be used in applications such as production of aptamers and monoclonal antibodies.
    Matched MeSH terms: Reagent Kits, Diagnostic
  11. Rafiza S, Rampal KG
    Int J Tuberc Lung Dis, 2012 Feb;16(2):163-8.
    PMID: 22236915 DOI: 10.5588/ijtld.11.0364
    BACKGROUND: Serial testing for tuberculosis (TB) exposure has been advocated among health care workers (HCWs) at risk of nosocomial infection.
    OBJECTIVE: To determine the incidence and factors associated with TB infection among selected HCWs in Malaysia and to determine interferon-gamma response in serial testing.
    DESIGN: A cohort of 769 HCWs were retested after 1 year using QuantiFERON®-TB Gold In-Tube. Incidence of TB infection was determined among HCWs who previously tested negative. Conversion and reversion rates using several definitions were explored.
    RESULTS: Incidence of TB infection was 9.9 per 100 workers per year (95%CI 7.9-12.3). Working in the Emergency Department (ED; RR 2.18, 95%CI 1.07-4.43) was significantly associated with risk of TB infection. Reversion and conversion occurred frequently, with 46.7% reversion among HCWs with baseline interferon-gamma (IFN-γ) levels of 0.35-0.70 international units (IU)/ml, and 23.8% conversion among HCWs with baseline IFN-γ levels of 0.20-0.34 IU/ml.
    CONCLUSIONS: TB infection control measures need to be strengthened, particularly in the ED, as the incidence of TB was high. Conversion and reversion rates in serial testing were high, and further studies are needed to facilitate its interpretation.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  12. Azma RZ, Hidayati N, Farisah NR, Hamidah NH, Ainoon O
    PMID: 21073074
    Glucose-6-phosphate dehydrogenase (G6PD) deficiency is one of the commonest causes of neonatal jaundice in Malaysia. Screening of cord blood for G6PD deficiency by the semiquantitative fluorescent spot test (FST) is performed in Malaysia but this test can miss cases of partial G6PD deficiency. The OSMMR-D kit assay measures G6PD activity and hemoglobin (Hb) concentration, allowing direct expression of results in U/gHb. We evaluated this method and established the normal range for G6PD activity in normal term neonates and adults. EDTA blood from 94 neonates and 295 adults (age 15-59 years old) with normal Hb and FST were selected. The normal means for G6PD activity for neonates and adults were 12.43 +/- 2.28 U/gHb and 9.21 +/- 2.6 U/gHb, respectively; the reference ranges for normal G6PD activity in neonates and adults were 10.15-14.71 U/gHb and 6.61-11.81 U/gHb respectively. There were no significant differences in mean normal G6PD activity between the Malays and Chinese racial groups or between genders. The upper and lower limit cut-off points for partial deficiency in neonates were 7.4 U/gHb (60% of the normal mean) and 2.5 U/gHb (20% of the normal mean), respectively. For adults, the upper and lower limit cut-off points for partial deficiency in adults were 5.52 U/gHb (60% of the normal mean) and 1.84 U/gHb (20% of the normal mean), respectively. The quantitation of G6PD enzymes using this OSMMR-D kit with Hb normalization was simple since the Hb was analyzed simultaneously and the results were reproducible with a CV of less than 5%.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  13. Muniandy S, Qvist R, Zaini A, Chinna K, Ismail IS
    PMID: 16295560
    The concentration of plasma sialic acid was estimated using the modified chemical method and the more sensitive enzymatic method in 20 subjects with impaired glucose tolerance and 20 control subjects. The mean sialic acid concentration values of the control subjects and subjects with impaired glucose tolerance using the enzymatic method were 1.747 +/- 0.047 and 2.583 +/- 0.070 mmole/l and 1.753 +/- 0.067 and 2.591 +/- 1.02 mmole/l for the chemical method. The intra-assay coefficient of variation for the control subjects and for the subjects with impaired glucose tolerance were 1.963% and 1.583%, respectively, for the enzymatic assay and 2.728% and 2.431%, respectively, for the chemical assay. The inter-assay coefficient of variation for the control subjects and for the subjects with impaired glucose tolerance were 2.686% and 2.723% for the enzymatic assay, and 3.819% and 3.95% for the chemical assay. Since the values do not differ significantly, the chemical assay is a cost effective method that can be used in large epidemiological studies.
    Matched MeSH terms: Reagent Kits, Diagnostic
  14. Uyub AM, Anuar AK, Aiyar S
    PMID: 7855648
    Two commercial serological kits, Pylori-set (Orion Diagnostica, Finland) and Helico-G (Cambridge Biomedical Ltd, UK), and an in-house ELISA were evaluated with sera from 24 Helicobacter pylori-positive and 146 H. pylori-negative dyspeptic patients. Sensitivity, specificity, positive and negative predictive values of Pylori-set were lower than that of Helico-G and in-house ELISA. Helico-G was more sensitive (91.7%) than in-house ELISA (83.3%) and both had comparable negative predictive values of 98.3% and 97.3%, respectively. However, specificity (97.9%) and positive predictive value (86.9%) of an in-house ELISA were much higher than specificity (80.1%) and positive predictive value (43.1%) of Helico-G. Kappa index of agreement between the three serological tests (Pylori-set, Helico-G or in-house ELISA) and the presence of H. pylori in antral biopsies was very low (k = 0.13; z = 1.9; p > 0.05), moderate (k = 0.49; z = 7.1; p < 0.0001), or substantial (k = 0.82; z = 10.8; p < 0.0001), respectively. Overall, statistical evaluations demonstrated that both commercial kits were not as reliable as the in-house ELISA for serodiagnosing H. pylori infection.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  15. Khairullah NS, Lam SK
    PMID: 8629057
    In 1990 and 1991, six laboratories located in the WHO Western Pacific Region (WPR) and South East Asian Region (SEAR) were selected, based on their experience in the immunofluorescence antibody technique (IFAT), to participate in the evaluation of a WHO monoclonal antibody (Mab) kit to detect respiratory syncytial (RS) virus, influenza A virus, influenza B virus, parainfluenza virus and adenovirus. Despite differences in the initial standardization procedures, the WHO monoclonal antibodies were found to be of high quality, sensitivity and specificity when tested on clinical specimens. The constant supply of affordable high quality reagents from WHO would enable their use in clinical virological laboratories in the developing countries as well as promote the utilization of IFAT as an adjunct to cell culture isolation in the diagnosis of acute respiratory viral infections.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  16. Noordin R, Shenoy RK, Rahman RA
    PMID: 15115085
    Brugia malayi infection is endemic in several Asian countries. Filaria-specific IgG4 antibody detection based on BmR1 recombinant antigen has been shown to be sensitive and specific for the diagnosis of brugian filariasis. Two formats of the test has been reported ie indirect ELISA (BE) and rapid dipstick test (BR). Since different test formats use different amounts of sample and reagents which may affect its sensitivity and specificity, this study was performed to compare these two test formats in the detection of B. malayi. A total of 264 blinded serum samples from India and Malaysia were employed. Group 1 comprised 164 samples from actively infected individuals and group 2 comprised 100 samples from filaria non-endemic areas. Sensitivity was 96.3% (158/164) and 90.8% (149/164) for rapid test and ELISA respectively; chi-square p=0.00. Both test formats demonstrated 100% specificity. Therefore the rapid test format was equally specific but more sensitive than the ELISA format. The ELISA format would be able to demonstrate decline in IgG4 titer post-treatment while the rapid test would be very useful for screening and diagnosis in the field.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  17. Kumarasamy V, Zuridah H, Hani AW, Mariam M, Chua KB
    Med J Malaysia, 2007 Mar;62(1):85-6.
    PMID: 17682584 MyJurnal
    The performance of a commercial rapid immunochromatographic dengue IgG/IgM assay device was evaluated against an in-place dengue IgM-capture ELISA in the National Public Health laboratory. Of the 239 serum samples from patients with clinical diagnosis of acute dengue illness, 140 and 99 samples were tested positive and negative respectively for anti-dengue IgM by the in-placed ELISA. Comparatively, 72 and 76 samples were tested positive and negative respectively, and 91 samples gave equivocal results by the rapid dengue test device. The rapid immunochromatographic assay device gave a relative sensitivity of 49.3% and a relative specificity of 62.6%. Though the rapid immunochromatographic assay device has the advantages of rapid testing which simultaneously detects both IgG and IgM and can also be performed with whole blood, serum or plasma, the user has to exercise extreme caution with the interpretation of the test result.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  18. Musalmah M, Normah J, Wan Mohamad WB, Salwah ON, Fatah HA, Nik Zahari NA
    Med J Malaysia, 2000 Sep;55(3):352-6.
    PMID: 11200716
    The effect of HbE, a hemoglobin variant, on the determination of HbA1/HbA1c using 4 commercial kits based on cation-exchange resin, cation-exchange column chromatography and specific antibody techniques was studied. Fifty-eight normal and 63 HbE heterozygous subjects were tested for HbA1 and HbA1c using 4 commercial kits i.e. Eagles Diagnostics, Boehringer Mannehim (BM), Diastat and Ames DCA 2000. Analyses of the samples by the 4 kits were done within one week and samples were stored at 4 degrees C before analysis. The results showed that HbE affects the determination of glycosylated hemoglobin using cation-exchange based and not kits based on specific antibody techniques.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  19. Mak JW, Khalid BA
    Med J Malaysia, 1992 Dec;47(4):235-7.
    PMID: 1303475
    Matched MeSH terms: Reagent Kits, Diagnostic