Displaying publications 1 - 20 of 67 in total

Abstract:
Sort:
  1. Ch'ng SL
    Med J Malaysia, 1987 Dec;42(4):225-9.
    PMID: 3454393
    Matched MeSH terms: Reagent Kits, Diagnostic*
  2. Ganatra R, Gembicki M, Nofal M
    Nucl Med Commun, 1988 Feb;9(2):131-9.
    PMID: 3386976
    The third and final meeting of a coordinated research programme on the diagnosis and management of thyroid disorders was held in Vienna from 15 to 17 December 1986. The participants were from Czechoslovakia, Egypt, Israel, Malaysia and Thailand. Each participant had studied between 500 and 1000 patients for thyroid function evaluation by performing T3, T4 and TSH radioimmunoassays. Each had also used the newly available supersensitive immunoradiometric (IRMA) assay in a group of patients to compare the efficiency of the new assay with that of the conventional assay. A microcomputer was provided to each participant for data analysis. Internal quality control was studied by establishing precision profiles and external quality control was on the basis of pooled standard sera in different ranges. Recommendation for the strategy suggested T4 RIA as the test of first choice in each category of thyroid function. IRMA TSH was suggested as a second test in borderline cases.
    Matched MeSH terms: Reagent Kits, Diagnostic
  3. Cheong YM, Jegathesan M, Ansary A, Othman M
    Med J Malaysia, 1990 Mar;45(1):42-8.
    PMID: 2152068
    The prevalence of Enterotoxigenic Escherichia coli (ETEC) in 433 stool samples from diarrhoeal cases of all ages was studied using two commercially available test kits for the detection of heat labile toxin (LT) and the infant mouse assay for the heat stable toxin (ST). 16 samples (3.7%) were positive for ETEC, of which nine were producing ST alone, six LT alone and only one was producing both LT and ST. Although the percentage of isolation rate was low, its occurrence was almost as common as the Shigella spp and Salmonella spp in the same study. Of the two test kits examined, the Phadebact ETEC-LT Test 50 (Pharmacia Diagnostics, Uppsala, Sweden) was found to be more suitable for use in a routine diagnostic laboratory. Ten out of 12 (83%) of the strains tested were resistant to one or more antibiotics.
    Matched MeSH terms: Reagent Kits, Diagnostic
  4. Wan Nazaimoon WM, Satgunasingam N, Khalid B
    Malays J Pathol, 1990 Jun;12(1):13-20.
    PMID: 2090885
    A simple and sensitive double-antibody radioimmunoassay for human growth hormone (HGH) was developed, optimised and validated. The anti-hGH sera raised in 2 rabbits were highly specific with low cross-reactions of 0.19% and 0.3% with human placental lactogen and 0.21% and 0.13% with human prolactin. The mean sensitivity of the assay determined from 28 assays was found to be 0.4 +/- 0.2 mIU/L. Mean recovery of added exogenous hGH was 98.8 +/- 6.8%. Linearity studies of samples diluted at 1:2, 1:4 and 1:8 gave values of 101.3 +/- 5.3%, 109.6 +/- 13.4% and 97.3 +/- 13% respectively of those expected. The reproducibility of the assay was good; within assay coefficient of variation for serum samples with GH concentrations of 2.7, 13.6 and 28.2 mU/l ranged from 5.1 to 8.3% while the inter-assay precision varied from 4.9 to 10.3%. The in-house assay showed good correlation (r = 0.96, p less than 0.001) with a commercial HGH RIA kit (Dainabot, Japan). A reference normal adult fasting GH level of less than 7 mIU/l was established from 95 samples assayed by this method.
    Matched MeSH terms: Reagent Kits, Diagnostic
  5. Kelly DJ, Wong PW, Gan E, Chye CT, Cowan D, Lewis GE
    Am J Trop Med Hyg, 1990 Sep;43(3):301-7.
    PMID: 2121057
    Scrub typhus is a major cause of febrile illness throughout the Asia-Pacific region. It is commonly undiagnosed, partly because of the lack of a simple, reliable diagnostic test which can be used in clinical laboratories. The indirect immunoperoxidase technique, configured into a test kit, was provided to technicians who were trained in its use. They used the kit during a 2 year field trial in their respective clinical hospital laboratories throughout Malaysia. In an evaluation using 1,722 consecutive sera tested in those laboratories, the kit was found to have a median sensitivity for IgG detection of 0.85 (range 0.33-0.95), a median specificity of 0.94 (range 0.88-1.00), reproducibility of 0.86, and efficiency of 0.92 when compared to the reference laboratory. In a proficiency survey in which 10 laboratories received 3 coded test samples, all but 2 laboratories had results within 1 dilution of the reference laboratory in quantitating specific IgG, whereas 7 laboratories were within 1 dilution in quantitating IgM. The shelf life of the kit was at least 1 year at 4 degrees C.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  6. Fang R, Sinniah M, Kuen LS
    Malays J Pathol, 1992 Dec;14(2):117-20.
    PMID: 1304624
    Dengue fever/Dengue haemorrhagic fever (DF/DHF) has been a public health problem in Malaysia with an endemic level of about 7 per 100,000 population per year. In 1990, Malaysia experienced its most severe outbreak of DF/DHF with a record total of 5,590 cases referred to the Division of Virology, Institute for Medical Research (IMR). Of these, 1,880 were confirmed serologically to be DF/DHF. The conventional serological procedure, the Haemagglutination Inhibition (HI) test, for the diagnosis of DF/DHF is cumbersome and causes delay in diagnosis. Another problem associated with the HI test has been that it has often been difficult to obtain a second convalescent serum sample for an accurate diagnosis. This has raised an urgent need to establish a "rapid" test for diagnosis of DF/DHF. As such the authors recently carried out an evaluation of a newly available commercial rapid test, namely, the Dengue Blot Assay (Diagnostic Biotechnology Singapore Pte Ltd). The test is intended for use in laboratory confirmation of dengue virus infection. The evaluation was to determine if the test could be utilised as a routine laboratory test and to establish its sensitivity and specificity. Over 400 samples were tested against the Dengue Blot Assay. Results were checked against an in-house Dengue IgM ELISA and HI assay. Preliminary results indicate that the sensitivity and specificity of the Dengue Blot is satisfactory. Our results also indicate that the Dengue Blot has a useful role to play in a routine laboratory especially since it provides rapid results on single serum samples thereby reducing the workload in a busy diagnostic laboratory.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  7. Mak JW, Khalid BA
    Med J Malaysia, 1992 Dec;47(4):235-7.
    PMID: 1303475
    Matched MeSH terms: Reagent Kits, Diagnostic
  8. Lam SK
    Malays J Pathol, 1993 Jun;15(1):9-12.
    PMID: 8277797
    Matched MeSH terms: Reagent Kits, Diagnostic
  9. Koay AS, Cheong YM
    Malays J Pathol, 1993 Jun;15(1):69-73.
    PMID: 8277794
    Forty-four serum samples of various reactivities to rickettsial antigens demonstrated by the indirect immunoperoxidase technique were tested with INDX Dip-S-Ticks (INDX Integrated Diagnostics Inc., USA) Kit for the detection of tick borne diseases. The kit utilised Rickettsia rickettsii the causative agent of Rocky Mountain spotted fever (RMSF) as antigens. The samples positive for endemic typhus were also tested against R. typhi, the agent for endemic typhus by the same method. The aim of this study was to determine the extent of cross-reactivity of R. rickettsii with rickettsial infections in Malaysia. Nine out of 12 tick typhus, 4 out of 10 scrub typhus and 4 out of 12 endemic typhus samples cross reacted with R. rickettsii. Ten out of 12 endemic samples were positive with R. typhi by the same method. From the study, we concluded that the INDX Dip-S-Ticks Kit can be used as a rapid screening test to detect endemic and tick-borne rickettsial infections in Malaysia but a second serological test is strongly recommended on all weakly reactive cases.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  10. Uyub AM, Anuar AK, Aiyar S
    PMID: 7855648
    Two commercial serological kits, Pylori-set (Orion Diagnostica, Finland) and Helico-G (Cambridge Biomedical Ltd, UK), and an in-house ELISA were evaluated with sera from 24 Helicobacter pylori-positive and 146 H. pylori-negative dyspeptic patients. Sensitivity, specificity, positive and negative predictive values of Pylori-set were lower than that of Helico-G and in-house ELISA. Helico-G was more sensitive (91.7%) than in-house ELISA (83.3%) and both had comparable negative predictive values of 98.3% and 97.3%, respectively. However, specificity (97.9%) and positive predictive value (86.9%) of an in-house ELISA were much higher than specificity (80.1%) and positive predictive value (43.1%) of Helico-G. Kappa index of agreement between the three serological tests (Pylori-set, Helico-G or in-house ELISA) and the presence of H. pylori in antral biopsies was very low (k = 0.13; z = 1.9; p > 0.05), moderate (k = 0.49; z = 7.1; p < 0.0001), or substantial (k = 0.82; z = 10.8; p < 0.0001), respectively. Overall, statistical evaluations demonstrated that both commercial kits were not as reliable as the in-house ELISA for serodiagnosing H. pylori infection.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  11. Khairullah NS, Lam SK
    PMID: 8629057
    In 1990 and 1991, six laboratories located in the WHO Western Pacific Region (WPR) and South East Asian Region (SEAR) were selected, based on their experience in the immunofluorescence antibody technique (IFAT), to participate in the evaluation of a WHO monoclonal antibody (Mab) kit to detect respiratory syncytial (RS) virus, influenza A virus, influenza B virus, parainfluenza virus and adenovirus. Despite differences in the initial standardization procedures, the WHO monoclonal antibodies were found to be of high quality, sensitivity and specificity when tested on clinical specimens. The constant supply of affordable high quality reagents from WHO would enable their use in clinical virological laboratories in the developing countries as well as promote the utilization of IFAT as an adjunct to cell culture isolation in the diagnosis of acute respiratory viral infections.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  12. Khairullah NS
    Malays J Pathol, 1996 Jun;18(1):27-30.
    PMID: 10879221
    Two different preparations of monoclonal antibodies developed against respiratory viruses have been evaluated by the immunofluorescence antibody technique. The Chemicon monoclonal antibodies were found to be more efficient at picking up positive specimens with a high sensitivity and specificity than Imagen monoclonal antibodies. However, the overall concordance rate of the monoclonal antibodies was 92.3%-100%. Generally, when compared with cell culture isolation, the immunofluorescence antibody technique was found to be more sensitive. The high quality of the Chemicon monoclonal antibodies contribute to their value in providing definitive diagnosis, within a few hours of specimen collection, thus allowing early management of patients, their contacts and control of hospital infection.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  13. Lam SK, Fong MY, Chungue E, Doraisingham S, Igarashi A, Khin MA, et al.
    Clin Diagn Virol, 1996 Nov;7(2):93-8.
    PMID: 9137865 DOI: 10.1016/S0928-0197(96)00257-7
    The traditional methods used in the diagnosis of dengue infection do not lend themselves to field application. As such, clinical specimens have to be sent to a central laboratory for processing which invariably leads to delay. This affects patient management and disease control. The development of the dengue IgM dot enzyme immunoassay has opened up the possibility of carrying out the test in peripheral health settings.
    Matched MeSH terms: Reagent Kits, Diagnostic
  14. Ooi BG, Sinniah M, Ismail S, Baharuddin R
    Malays J Pathol, 1996 Dec;18(2):89-93.
    PMID: 10879228
    The Serodia-HCV Particle Agglutination (HCV-PA) for the detection of HCV antibodies was compared with the Enzyme Immunoassay Test (UBI HCV EIA) for possible in-house use. A total of 150 specimens were analysed using UBI HCV EIA and Serodia-HCV PA. Of these, 80 (53.3%) were both PA and EIA positive and 59 (39.3%) were negative by both techniques. Eleven sera (7.4%) were found to be EIA-positive but PA-negative. These 11 discordant sera were further tested by the LiaTek-HCV III Immunoassay (Organon Teknika). Ten were found to be line immunoassay negative and one was line immunoassay positive. Failure of the PA to detect the HCV positive serum meant that a small proportion of HCV antibody positives may be missed by the PA test. We conclude that (i) EIA should continue to be the first line screening test in our laboratory, (ii) PA with its 100% specificity could be a useful supplementary screen for all EIA-positive sera and finally (iii) line immunoassay could be used on sera to resolve discordant results in the EIA and PA assays.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  15. Lam SK, Devine PL
    Clin Diagn Virol, 1998 May 1;10(1):75-81.
    PMID: 9646004
    Rapid diagnosis of dengue infection is essential to patient management and disease control. The development of a rapid (5 min) immunochromatographic test and a 2 h commercial capture enzyme linked immunosorbent assay (ELISA) for anti-dengue IgM and IgG antibodies may lead to more rapid and accurate testing in peripheral health settings and diagnostic laboratories.
    Matched MeSH terms: Reagent Kits, Diagnostic
  16. Hamilton RG, Adkinson NF
    J Allergy Clin Immunol, 1998 Sep;102(3):482-90.
    PMID: 9768592
    BACKGROUND: No characterized diagnostic natural rubber latex skin testing material is licensed for use in the United States.

    OBJECTIVE: We have conducted a multicenter clinical skin testing study to document the safety and diagnostic sensitivity and specificity of a candidate Hevea brasiliensis nonammoniated latex (NAL) extract. These data are intended to support the licensing of this reagent for the diagnosis of latex allergy in high-risk populations.

    METHODS: Three hundred twenty-four subjects (304 adults and 20 children) were classified by their clinical history as having latex allergy (LA group, 124 adults and 10 children) or having no latex allergy (NLA group, 180 adults and 10 children). All subjects provided blood samples and then received sequential puncture skin tests (PSTs) at 1, 100, or 1000 microg/mL protein with a bifurcated needle and NAL (Greer Laboratories) from Malaysian Hevea brasiliensis (clone 600) sap. A 2-stage glove provocation test was used to clarify latex allergy status of individuals with positive history/negative PST result and negative history/positive PST result mismatches.

    RESULTS: Twenty-four subjects (15%) originally designated as having LA on the basis of their initial clinical history were reclassified to the NLA group on the basis of a negative glove provocation test result. Of the 134 subjects with LA, 54 (40%) were highly sensitive to latex, with a positive PST result at 1 microg/mL NAL. The Greer NAL reagent produced a positive PST rate (sensitivity) of 95% and 99% in subjects with LA at 100 microg/mL and 1 mg/mL, respectively. The negative PST rate (specificity) in 190 subjects with a negative history with the NAL extract at 100 microg/mL and 1 mg/mL, was 100% and 96%, respectively. Immediately after the PST, mild systemic reactions (mainly pruritus) were recorded in 16.1 % of the adults in the LA group and 4.4% of the adults in the NLA group. No reactions required treatment with epinephrine. Only mild delayed reactions were observed in 9.6% (LA group) and 2.8% (NLA group) of subjects 24 to 48 hours after PST. Mean wheal and erythema diameters measured in the 10 children in the LA group with spina bifida at 100 microg/mL and 1 mg/mL were similar to those observed in the adults in the LA group, suggesting that children are not at increased risk for systemic reactions compared with adults.

    CONCLUSIONS: A suggestive clinical history is necessary but not sufficient for a definitive diagnosis of IgE-dependent latex allergy. These data support the safety and diagnostic efficacy of the Greer NAL, skin test reagent at 100 micro/mL and 1 mg/mL for confirmatory PSTs.

    Matched MeSH terms: Reagent Kits, Diagnostic
  17. Wu LL, Sazali BS, Adeeb N, Khalid BA
    Singapore Med J, 1999 Jan;40(1):23-6.
    PMID: 10361481
    Clinical diagnosis of congenital hypothyroidism (CH) is difficult at birth without neonatal screening. In line with the priorities of the national health services in Malaysia towards preventive medicine, early diagnosis and treatment of CH is emphasised. We conducted a pilot study at Kuala Lumpur's Maternity Hospital between April 1995 and November 1995 to estimate the incidence of CH and also evaluated the problems associated with large-scale neonatal screening using a commercial TSH kit on cord bloodspots.
    Matched MeSH terms: Reagent Kits, Diagnostic
  18. Choo KE, Davis TM, Ismail A, Tuan Ibrahim TA, Ghazali WN
    Acta Trop, 1999 Mar 15;72(2):175-83.
    PMID: 10206117
    The Typhidot test, which detects IgM and IgG antibodies to a Salmonella typhi-specific outer membrane protein, is as sensitive as, and more specific than, the Widal test in the diagnosis of enteric fever in Malaysian children. It is easier and quicker to perform. In order to increase diagnostic accuracy in an area of high endemicity, the Typhidot-M test has been developed in which IgG is first removed. This theoretically allows improved detection of IgM, and thus would differentiate new from recent infections. We evaluated both tests in 134 unselected febrile children admitted to the General Hospital Kota Bharu, Malaysia. The children were divided into two groups: (i) those who were blood and/or stool culture positive for S. typhi and/or who had clinical features strongly suggestive of enteric fever (n = 62); and (ii) those who were both culture-negative and had clinical evidence of another diagnosis (n = 72). The sensitivity and specificity of the Typhidot and Typhidot-M tests were identical at 90.3 and 93.1%, respectively. Both tests had comparable sensitivity but greater specificity than those of the Widal test (91.9 and 80.6%, respectively). When used together, a positive result for Typhidot and/or Typhidot-M was more specific than either test alone (95.2%) but specificity was lower (87.5%). We conclude that the Typhidot and Typhidot-M tests have comparatively high diagnostic accuracy, suggesting that IgM can be detected in children who may have a predominant IgG response to S. typhi. Using these tests in combination increases the negative predictive value but at the cost of a lower positive predictive value.
    Matched MeSH terms: Reagent Kits, Diagnostic
  19. Bhutta ZA, Mansurali N
    Am J Trop Med Hyg, 1999 Oct;61(4):654-7.
    PMID: 10548305
    We evaluated the diagnostic sensitivity and specificity of two dot-enzyme-linked immunoassays (Typhidot and Typhidot-M; Malaysian Biodiagnostic Research SDN BHD, Kuala Lumpur, Malaysia), assessing IgG and IgM antibodies against the outer membrane protein (OMP) of Salmonella typhi, and the Widal test in comparison with blood culture in a consecutive group of children with suspected typhoid fever. Of 97 children with suspected typhoid fever, the disease was confirmed bacteriologically in 46 (47%), whereas 25 (26%) were considered to have typhoid fever on clinical grounds. An alternative diagnosis was made in 26 (27%). The Typhidot and Typhidot-M were superior to the Widal test in their diagnostic sensitivity and specificity, although values (sensitivity = 85-94% and specificity = 77-89%) were significantly lower than in other regional reports. The lower specificity of the Typhidot in our series may represent regional differences in the genomic structure and plasticity of the OMP of S. typhi and merits further evaluation of these tests in diverse geographic locations.
    Matched MeSH terms: Reagent Kits, Diagnostic