Displaying publications 1 - 20 of 67 in total

Abstract:
Sort:
  1. Choo KE, Davis TM, Ismail A, Tuan Ibrahim TA, Ghazali WN
    Acta Trop, 1999 Mar 15;72(2):175-83.
    PMID: 10206117
    The Typhidot test, which detects IgM and IgG antibodies to a Salmonella typhi-specific outer membrane protein, is as sensitive as, and more specific than, the Widal test in the diagnosis of enteric fever in Malaysian children. It is easier and quicker to perform. In order to increase diagnostic accuracy in an area of high endemicity, the Typhidot-M test has been developed in which IgG is first removed. This theoretically allows improved detection of IgM, and thus would differentiate new from recent infections. We evaluated both tests in 134 unselected febrile children admitted to the General Hospital Kota Bharu, Malaysia. The children were divided into two groups: (i) those who were blood and/or stool culture positive for S. typhi and/or who had clinical features strongly suggestive of enteric fever (n = 62); and (ii) those who were both culture-negative and had clinical evidence of another diagnosis (n = 72). The sensitivity and specificity of the Typhidot and Typhidot-M tests were identical at 90.3 and 93.1%, respectively. Both tests had comparable sensitivity but greater specificity than those of the Widal test (91.9 and 80.6%, respectively). When used together, a positive result for Typhidot and/or Typhidot-M was more specific than either test alone (95.2%) but specificity was lower (87.5%). We conclude that the Typhidot and Typhidot-M tests have comparatively high diagnostic accuracy, suggesting that IgM can be detected in children who may have a predominant IgG response to S. typhi. Using these tests in combination increases the negative predictive value but at the cost of a lower positive predictive value.
    Matched MeSH terms: Reagent Kits, Diagnostic
  2. Ding CH, Situ SF, Steven A, Razak MFA
    Ann Clin Lab Sci, 2019 09;49(4):546-549.
    PMID: 31471347
    Candida auris is an emerging pathogenic yeast responsible for nosocomial infections with high mortality, on a global scale. A 65-year-old woman with hypovolemic shock and severe metabolic acidosis was intubated and admitted to the intensive care unit (ICU). Shortly after admission, she developed ventilator-associated pneumonia caused by multidrug-resistant Acinetobacter baumannii, which necessitated treatment with high-dose ampicillin-sulbactam. Two weeks later, a yeast was cultured from her blood. It formed pale pink colonies on CHROMagar Candida medium and produced predominantly oval budding yeast cells with the occasional rudimentary pseudohyphae on cornmeal agar. ID 32 C identified the yeast as Candida sake However, matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) and sequencing of the D1/D2 region of the 28S rRNA gene identified the yeast as C. auris.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  3. Chia WC, Khoo TS, Abdul Wahid SFS, Razak NFA, Alauddin H, Raja Sabudin RZA, et al.
    Ann Hematol, 2019 May;98(5):1279-1291.
    PMID: 30783731 DOI: 10.1007/s00277-019-03626-w
    Short tandem repeat (STR) analysis is used in chimerism monitoring after allogeneic hematopoietic stem cell transplantation (HSCT) for patients with various hematologic malignancies. Commercial forensic STR kits often contain loci with huge differences in power of discrimination (PD) across populations, causing some loci to be less informative for chimerism analysis in certain populations. This study aimed to construct a new STR multiplex panel with highly informative loci for efficient chimerism analysis. Thirteen STR markers which exhibit high PD (> 0.9) in at least 80% of 50 populations globally were selected to form a new panel and used in STR analysis of 253 Malaysian subjects. Cumulative power of discrimination (CPD) and combined power of exclusion (CPE) were determined from 253 Malaysian individuals. Loci informativity was assessed and compared to the commercial AmpFLSTR Identifiler PCR Amplification kit in 14 donor-recipient pairs. The new panel had detected 202 unique alleles including five novel alleles from the 253 individuals with high CPD and CPE (> 0.99999999999999999 and > 0.999999997 respectively). All loci from the new panel in the donor-recipient pair analysis showed higher than 50% informativity, while five loci from the commercial kit demonstrated lower than 50% informativity. Four loci from the new panel ranked the highest informativity. A sequenced allelic ladder which consists of 202 unique alleles from the 253 subjects was also developed to ensure accurate allele designation. The new 13-loci STR panel, thus, could serve as an additional powerful, accurate, and highly informative panel for chimerism analysis for HSCT patients.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  4. Hawkins R
    Ann Lab Med, 2013 Mar;33(2):156-8.
    PMID: 23479565 DOI: 10.3343/alm.2013.33.2.156
    Matched MeSH terms: Reagent Kits, Diagnostic
  5. Qin X, Rui J, Xia Y, Mu H, Song SH, Raja Aziddin RE, et al.
    Ann Lab Med, 2018 Mar;38(2):85-94.
    PMID: 29214751 DOI: 10.3343/alm.2018.38.2.85
    BACKGROUND: The immunosuppressant drugs (ISDs), tacrolimus and cyclosporine, are vital for solid organ transplant patients to prevent rejection. However, toxicity is a concern, and absorption is highly variable across patients; therefore, ISD levels need to be precisely monitored. In the Asia-Pacific (APAC) region, tacrolimus and cyclosporine concentrations are typically measured using immunoassays. The objective of this study was to assess the analytical performance of Roche Elecsystacrolimus and cyclosporinee electrochemiluminescence immunoassays (ECLIAs).

    METHODS: This evaluation was performed in seven centers across China, South Korea, and Malaysia. Imprecision (repeatability and reproducibility), assay accuracy, and lot-to-lot reagent variability were tested. The Elecsys ECLIAs were compared with commercially available immunoassays (Architect, Dimension, and Viva-E systems) using whole blood samples from patients with various transplant types (kidney, liver, heart, and bone marrow).

    RESULTS: Coefficients of variation for repeatability and reproducibility were ≤5.4% and ≤12.4%, respectively, for the tacrolimus ECLIA, and ≤5.1% and ≤7.3%, respectively, for the cyclosporine ECLIA. Method comparisons of the tacrolimus ECLIA with Architect, Dimension, and Viva-E systems yielded slope values of 1.01, 1.14, and 0.897, respectively. The cyclosporine ECLIA showed even closer agreements with the Architect, Dimension, and Viva-E systems (slope values of 1.04, 1.04, and 1.09, respectively). No major differences were observed among the different transplant types.

    CONCLUSIONS: The tacrolimus and cyclosporine ECLIAs demonstrated excellent precision and close agreement with other immunoassays tested. These results show that both assays are suitable for ISD monitoring in an APAC population across a range of different transplant types.

    Matched MeSH terms: Reagent Kits, Diagnostic
  6. Jamaludin S, Mustaffa N, Che Hamzah NA, Syed Abdul Aziz SH, Lee YY
    BMC Gastroenterol, 2015;15:101.
    PMID: 26264957 DOI: 10.1186/s12876-015-0332-0
    Unchanged substrate in a negative rapid urease test may be reused to detect Helicobacter pylori (H. pylori). This could potentially reduce costs and wastage in low prevalence and resource-poor settings. We thus aimed to investigate the diagnostic accuracy of reused Pronto Dry and CLOtest kits, comparing this to the use of new Pronto Dry test kits and histopathological evaluation of gastric mucosal biopsies.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  7. Ng BK, Lim PS, Shafiee MN, Ghani NA, Ismail NA, Omar MH, et al.
    Biomed Res Int, 2013;2013:587438.
    PMID: 24073412 DOI: 10.1155/2013/587438
    Objective. To determine the diagnostic accuracy of placental alpha microglobulin-1 assay and standard diagnostic methods for detecting rupture of membrane. Study Design. Prospective diagnostic study, between June 2011 to November 2011 at a tertiary centre. Initial evaluation included both the standard diagnostic methods for rupture of membranes and placental alpha microglobulin-1 immunoassay. The actual rupture of membranes was diagnosed on review of the medical records after delivery (absence of membrane or a positive pad chart). Main Outcome Measures. Placental alpha microglobulin-1 immunoassay and standard diagnostic methods for diagnosis of rupture of membrane. Results. A total of 211 patients were recruited. At initial presentation, 187 patients (88.6%) had ruptured membranes, while 24 patients (11.4%) had intact membranes. Placental alpha microglobulin-1 immunoassay confirmed rupture of membranes at initial presentation with a sensitivity of 95.7% (179 of 187), specificity of 100% (24 of 24), positive predictive value of 100% (179 of 179), and negative predictive value of 75.0% (24 of 32). By comparison, the conventional standard diagnostic methods had a sensitivity of 78.1% (146 of 187), specificity of 100% (24 of 24), positive predictive value of 100% (146 of 146), and negative predictive value of 36.9% (24 of 65) in diagnosing rupture of membrane. Conclusion. Placental alpha-microglobulin-1 immunoassay is a rapid and accurate method for confirming the diagnosis of rupture of membrane. It was superior to conventional standard diagnostic methods (pooling, nitrazine, and ferning), the nitrazine test alone or fern test alone.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  8. Loganathan R, Selvaduray KR, Nesaretnam K, Radhakrishnan AK
    Cell Prolif, 2013 Apr;46(2):203-13.
    PMID: 23510475 DOI: 10.1111/cpr.12014
    OBJECTIVES: Tocotrienols and tocopherols are members of the vitamin E family, with similar structures; however, only tocotrienols have been reported to achieve potent anti-cancer effects. The study described here has evaluated anti-cancer activity of vitamin E to elucidate mechanisms of cell death, using human breast cancer cells.

    MATERIALS AND METHODS: Anti-cancer activity of a tocotrienol-rich fraction (TRF) and a tocotrienol-enriched fraction (TEF) isolated from palm oil, as well as pure vitamin E analogues (α-tocopherol, α-, δ- and γ-tocotrienols) were studied using highly aggressive triple negative MDA-MB-231 cells and oestrogen-dependent MCF-7 cells, both of human breast cancer cell lines. Cell population growth was evaluated using a Coulter particle counter. Cell death mechanism, poly(ADP-ribose) polymerase cleavage and levels of NF-κB were determined using commercial ELISA kits.

    RESULTS: Tocotrienols exerted potent anti-proliferative effects on both types of cell by inducing apoptosis, the underlying mechanism of cell death being ascertained using respective IC50 concentrations of all test compounds. There was marked induction of apoptosis in both cell lines by tocotrienols compared to treatment with Paclitaxel, which was used as positive control. This activity was found to be associated with cleavage of poly(ADP-ribose) polymerase (a DNA repair protein), demonstrating involvement of the apoptotic cell death signalling pathway. Tocotrienols also inhibited expression of nuclear factor kappa-B (NF-κB), which in turn can increase sensitivity of cancer cells to apoptosis.

    CONCLUSION: Tocotrienols induced anti-proliferative and apoptotic effects in association with DNA fragmentation, poly(ADP-ribose) polymerase cleavage and NF-κB inhibition in the two human breast cancer cell lines.

    Matched MeSH terms: Reagent Kits, Diagnostic
  9. Kit Lam S, Lan Ew C, Mitchell JL, Cuzzubbo AJ, Devine PL
    Clin Diagn Lab Immunol, 2000 Sep;7(5):850-2.
    PMID: 10973469
    A commercially available enzyme-linked immunosorbent assay (ELISA) (PanBio Dengue Screening ELISA) that utilized both immunoglobulin M (IgM) and IgG capture in the same microtiter well for the diagnosis of dengue infection was evaluated. Sensitivity in primary and secondary dengue was 95%, while specificity was 94%.
    Matched MeSH terms: Reagent Kits, Diagnostic
  10. Lam SK, Devine PL
    Clin Diagn Virol, 1998 May 1;10(1):75-81.
    PMID: 9646004
    Rapid diagnosis of dengue infection is essential to patient management and disease control. The development of a rapid (5 min) immunochromatographic test and a 2 h commercial capture enzyme linked immunosorbent assay (ELISA) for anti-dengue IgM and IgG antibodies may lead to more rapid and accurate testing in peripheral health settings and diagnostic laboratories.
    Matched MeSH terms: Reagent Kits, Diagnostic
  11. Lam SK, Fong MY, Chungue E, Doraisingham S, Igarashi A, Khin MA, et al.
    Clin Diagn Virol, 1996 Nov;7(2):93-8.
    PMID: 9137865 DOI: 10.1016/S0928-0197(96)00257-7
    The traditional methods used in the diagnosis of dengue infection do not lend themselves to field application. As such, clinical specimens have to be sent to a central laboratory for processing which invariably leads to delay. This affects patient management and disease control. The development of the dengue IgM dot enzyme immunoassay has opened up the possibility of carrying out the test in peripheral health settings.
    Matched MeSH terms: Reagent Kits, Diagnostic
  12. Looi ML, Zakaria H, Osman J, Jamal R
    Clin. Lab., 2012;58(3-4):307-12.
    PMID: 22582505
    Saliva has been suggested as an attractive resource for evaluating physiological and pathological conditions in humans. This study aims to evaluate saliva sampling as an alternative to blood sampling for molecular testing.
    Matched MeSH terms: Reagent Kits, Diagnostic
  13. Mohd-Hairul AR, Sade AB, Yiap BC, Raha AR
    Genet. Mol. Res., 2011;10(4):2757-64.
    PMID: 22095601 DOI: 10.4238/2011.November.8.1
    DNA extraction was carried out on 32 medicinal plant samples available in Malaysia using the TriOmic(TM) extraction kit. Amounts of 0.1 g flowers or young leaves were ground with liquid nitrogen, lysed at 65°C in RY1(plus) buffer and followed by RNAse treatment. Then, RY2 buffer was added to the samples and mixed completely by vortexing before removal of cell debris by centrifugation. Supernatants were transferred to fresh microcentrifuge tubes and 0.1 volume RY3 buffer was added to each of the transferred supernatant. The mixtures were applied to spin columns followed by a centrifugation step to remove buffers and other residues. Washing step was carried out twice by applying 70% ethanol to the spin columns. Genomic DNA of the samples was recovered by applying 50 μL TE buffer to the membrane of each spin column, followed by a centrifugation step at room temperature. A modification of the TriOmic(TM) extraction procedure was carried out by adding chloroform:isoamyl alcohol (24:1) steps in the extraction procedure. The genomic DNA extracted from most of the 32 samples showed an increase of total yield when chloroform:isoamyl alcohol (24:1) steps were applied in the TriOmicTM extraction procedure. This preliminary study is very important for molecular studies of medicinal plants available in Malaysia since the DNA extraction can be completed in a shorter period of time (within 1 h) compared to manual extraction, which entails applying phenol, chloroform and ethanol precipitation, and requires 1-2 days to complete.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  14. Ismail NM, Abdul Ghafar N, Jaarin K, Khine JH, Top GM
    Int J Food Sci Nutr, 2000;51 Suppl:S79-94.
    PMID: 11271860
    The present study aims to examine the effects of a palm-oil-derived vitamin E mixture containing tocotrienol (approximately 70%) and tocopherol (approximately 30%) on plasma lipids and on the formation of atherosclerotic plaques in rabbits given a 2% cholesterol diet. Eighteen New Zealand White rabbits (2.2-2.8 kg) were divided into three groups; group 1 (control) was fed a normal diet, group 2 (AT) was fed a 2% cholesterol diet and group 3 (PV) was fed a 2% cholesterol diet with oral palm vitamin E (60 mg/kg body weight) given daily for 10 weeks. There were no differences in the total cholesterol and triacylglycerol levels between the AT and PV groups. The PV group had a significantly higher concentrations of HDL-c and a lower TC/HDL-c ratio compared to the AT group (P < 0.003). The aortic tissue content of cholesterol and atherosclerotic lesions were comparable in both the AT and PV groups. However, the PV group had a lower content of plasma and aortic tissue malondialdehyde (P < 0.005). Our findings suggest that despite a highly atherogenic diet, palm vitamin E improved some important plasma lipid parameters, reduced lipid peroxidation but did not have an effect on the atherosclerotic plaque formation.
    Matched MeSH terms: Reagent Kits, Diagnostic
  15. Amran F, Liow YL, Halim NAN
    J Korean Med Sci, 2018 Apr 23;33(17):e131.
    PMID: 29686599 DOI: 10.3346/jkms.2018.33.e131
    Leptospirosis is a febrile zoonotic disease. Routine diagnosis of leptospirosis is based on the detection of specific antibodies with serological tests. The aim of our study was to determine the usefulness of immunochromatographic assay (ICA), ImmuneMed Leptospira IgM Duo Rapid test kit from Korea, in rapid screening of acute leptospirosis in emergency cases with limited expertise. A total of 197 serum samples (93 positive, 104 negative) were selected randomly. The test has good diagnostic sensitivity 73% and specificity 90%. With positive predictive value of 87% and negative predictive value of 79%, this reassures patients have higher chance of correct diagnosis. This ICA is acceptable for screening of leptospirosis but confirmation with microscopic agglutination test should follow.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  16. Yoo SJ, Wang LL, Ning HC, Tao CM, Hirankarn N, Kuakarn S, et al.
    J Clin Virol, 2015 Mar;64:20-7.
    PMID: 25728074 DOI: 10.1016/j.jcv.2014.12.015
    Early diagnosis of hepatitis C virus (HCV) infection is essential to allow appropriate treatment and prevent transmission.
    Matched MeSH terms: Reagent Kits, Diagnostic
  17. Saville M, Hawkes D, Keung M, Ip E, Silvers J, Sultana F, et al.
    J Clin Virol, 2020 06;127:104375.
    PMID: 32361328 DOI: 10.1016/j.jcv.2020.104375
    BACKGROUND: In the last decade, human papillomavirus (HPV) testing has been evaluated extensively for cervical screening, with studies finding increased sensitivity compared to cytology. Another advantage of HPV based-screening is the ability to test vaginal samples that can be collected by women themselves. Self-collection has the potential to extend cervical screening coverage by increasing participation rates, particularly among women who are under-screened or have never screened. This could have a significant impact on cervical cancer prevention, as the majority of invasive cervical cancer cases occur among under-screened women. Both the Netherlands and Australia have transitioned their national programs from cytology to HPV as the primary screening test and both countries include a pathway for self-collection.

    OBJECTIVES: We evaluated the relative sensitivity for HPV detection of self-collection compared with practitioner-collected cervical specimens in the context of the Australian National Cervical Screening Program (NCSP).

    STUDY DESIGN: 303 women aged ≥18 years attending a single tertiary referral centre took their own sample using a flocked-swab, and then had a practitioner-collected sample taken at colposcopy. All samples were tested at a single laboratory on the six PCR-based HPV assays which can be utilised in the NCSP; Roche cobas 4800 and cobas, Abbott RealTime, BD Onclarity, Cepheid Xpert, and Seegene Anyplex.

    RESULTS: HPV16/18 results had high observed agreement between self- and practitioner-collected samples on all assays (range: 0.94-0.99), with good agreement for non-HPV16/18 oncogenic HPV types (range: 0.64-0.73).

    CONCLUSIONS: Self-collection for HPV-based cervical screening shows good concordance and relative sensitivity when compared to practitionercollected samples across assays in the NCSP.

    Matched MeSH terms: Reagent Kits, Diagnostic
  18. Goh KL, Cheah PL, Navaratnam P, Chin SC, Xiao SD
    J Dig Dis, 2007 Aug;8(3):139-42.
    PMID: 17650225
    The gastric biopsy urease test is an accurate and robust diagnostic test for Helicobacter pylori infection. Large endoscopy units use their own homemade unbuffered ultra-rapid urease test for diagnosis of H. pylori infection but several commercial rapid urease tests are available.
    Matched MeSH terms: Reagent Kits, Diagnostic/microbiology
  19. Yatabe Y, Kerr KM, Utomo A, Rajadurai P, Tran VK, Du X, et al.
    J Thorac Oncol, 2015 Mar;10(3):438-45.
    PMID: 25376513 DOI: 10.1097/JTO.0000000000000422
    The efficacy of epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors in EGFR mutation-positive non-small-cell lung cancer (NSCLC) patients necessitates accurate, timely testing. Although EGFR mutation testing has been adopted by many laboratories in Asia, data are lacking on the proportion of NSCLC patients tested in each country, and the most commonly used testing methods.
    Matched MeSH terms: Reagent Kits, Diagnostic
  20. Kumarasamy V, Wahab AH, Chua SK, Hassan Z, Chem YK, Mohamad M, et al.
    J Virol Methods, 2007 Mar;140(1-2):75-9.
    PMID: 17140671
    A commercial dengue NS1 antigen-capture ELISA was evaluated to demonstrate its potential application for early laboratory diagnosis of acute dengue virus infection. Dengue virus NS1 antigen was detected in 199 of 213 acute serum samples from patients with laboratory confirmation of acute dengue virus infection but none of the 354 healthy blood donors' serum specimens. The dengue NS1 antigen-capture ELISA gave an overall sensitivity of 93.4% (199/213) and a specificity of 100% (354/354). The sensitivity was significantly higher in acute primary dengue (97.3%) than in acute secondary dengue (70.0%). The positive predictive value of the dengue NS1 antigen-capture ELISA was 100% and negative predictive value was 97.3%. Comparatively, virus isolation gave an overall positive isolation rate of 68.1% with a positive isolation rate of 73.9 and 31.0% for acute primary dengue and acute secondary dengue, respectively. Molecular detection of dengue RNA by RT-PCR gave an overall positive detection rate of 66.7% with a detection rate of 65.2 and 75.9% for acute primary dengue and acute secondary dengue, respectively. The results indicate that the commercial dengue NS1 antigen-capture ELISA may be superior to virus isolation and RT-PCR for the laboratory diagnosis of acute dengue infection based on a single serum sample.
    Matched MeSH terms: Reagent Kits, Diagnostic*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links