Displaying publications 1 - 20 of 67 in total

Abstract:
Sort:
  1. Saville M, Hawkes D, Keung M, Ip E, Silvers J, Sultana F, et al.
    J Clin Virol, 2020 06;127:104375.
    PMID: 32361328 DOI: 10.1016/j.jcv.2020.104375
    BACKGROUND: In the last decade, human papillomavirus (HPV) testing has been evaluated extensively for cervical screening, with studies finding increased sensitivity compared to cytology. Another advantage of HPV based-screening is the ability to test vaginal samples that can be collected by women themselves. Self-collection has the potential to extend cervical screening coverage by increasing participation rates, particularly among women who are under-screened or have never screened. This could have a significant impact on cervical cancer prevention, as the majority of invasive cervical cancer cases occur among under-screened women. Both the Netherlands and Australia have transitioned their national programs from cytology to HPV as the primary screening test and both countries include a pathway for self-collection.

    OBJECTIVES: We evaluated the relative sensitivity for HPV detection of self-collection compared with practitioner-collected cervical specimens in the context of the Australian National Cervical Screening Program (NCSP).

    STUDY DESIGN: 303 women aged ≥18 years attending a single tertiary referral centre took their own sample using a flocked-swab, and then had a practitioner-collected sample taken at colposcopy. All samples were tested at a single laboratory on the six PCR-based HPV assays which can be utilised in the NCSP; Roche cobas 4800 and cobas, Abbott RealTime, BD Onclarity, Cepheid Xpert, and Seegene Anyplex.

    RESULTS: HPV16/18 results had high observed agreement between self- and practitioner-collected samples on all assays (range: 0.94-0.99), with good agreement for non-HPV16/18 oncogenic HPV types (range: 0.64-0.73).

    CONCLUSIONS: Self-collection for HPV-based cervical screening shows good concordance and relative sensitivity when compared to practitionercollected samples across assays in the NCSP.

    Matched MeSH terms: Reagent Kits, Diagnostic
  2. Zainol Rashid Z, Othman SN, Abdul Samat MN, Ali UK, Wong KK
    Malays J Pathol, 2020 Apr;42(1):13-21.
    PMID: 32342927
    INTRODUCTION: The World Health Organization (WHO) declared COVID-19 outbreak as a world pandemic on 12th March 2020. Diagnosis of suspected cases is confirmed by nucleic acid assays with real-time PCR, using respiratory samples. Serology tests are comparatively easier to perform, but their utility may be limited by the performance and the fact that antibodies appear later during the disease course. We aimed to describe the performance data on serological assays for COVID-19.

    MATERIALS AND METHODS: A review of multiple reports and kit inserts on the diagnostic performance of rapid tests from various manufacturers that are commercially available were performed. Only preliminary data are available currently.

    RESULTS: From a total of nine rapid detection test (RDT) kits, three kits offer total antibody detection, while six kits offer combination SARS-CoV-2 IgM and IgG detection in two separate test lines. All kits are based on colloidal gold-labeled immunochromatography principle and one-step method with results obtained within 15 minutes, using whole blood, serum or plasma samples. The sensitivity for both IgM and IgG tests ranges between 72.7% and 100%, while specificity ranges between 98.7% to 100%. Two immunochromatography using nasopharyngeal or throat swab for detection of COVID-19 specific antigen are also reviewed.

    CONCLUSIONS: There is much to determine regarding the value of serological testing in COVID-19 diagnosis and monitoring. More comprehensive evaluations of their performance are rapidly underway. The use of serology methods requires appropriate interpretations of the results and understanding the strengths and limitations of such tests.

    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  3. Ding CH, Situ SF, Steven A, Razak MFA
    Ann Clin Lab Sci, 2019 09;49(4):546-549.
    PMID: 31471347
    Candida auris is an emerging pathogenic yeast responsible for nosocomial infections with high mortality, on a global scale. A 65-year-old woman with hypovolemic shock and severe metabolic acidosis was intubated and admitted to the intensive care unit (ICU). Shortly after admission, she developed ventilator-associated pneumonia caused by multidrug-resistant Acinetobacter baumannii, which necessitated treatment with high-dose ampicillin-sulbactam. Two weeks later, a yeast was cultured from her blood. It formed pale pink colonies on CHROMagar Candida medium and produced predominantly oval budding yeast cells with the occasional rudimentary pseudohyphae on cornmeal agar. ID 32 C identified the yeast as Candida sake However, matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) and sequencing of the D1/D2 region of the 28S rRNA gene identified the yeast as C. auris.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  4. Chia WC, Khoo TS, Abdul Wahid SFS, Razak NFA, Alauddin H, Raja Sabudin RZA, et al.
    Ann Hematol, 2019 May;98(5):1279-1291.
    PMID: 30783731 DOI: 10.1007/s00277-019-03626-w
    Short tandem repeat (STR) analysis is used in chimerism monitoring after allogeneic hematopoietic stem cell transplantation (HSCT) for patients with various hematologic malignancies. Commercial forensic STR kits often contain loci with huge differences in power of discrimination (PD) across populations, causing some loci to be less informative for chimerism analysis in certain populations. This study aimed to construct a new STR multiplex panel with highly informative loci for efficient chimerism analysis. Thirteen STR markers which exhibit high PD (> 0.9) in at least 80% of 50 populations globally were selected to form a new panel and used in STR analysis of 253 Malaysian subjects. Cumulative power of discrimination (CPD) and combined power of exclusion (CPE) were determined from 253 Malaysian individuals. Loci informativity was assessed and compared to the commercial AmpFLSTR Identifiler PCR Amplification kit in 14 donor-recipient pairs. The new panel had detected 202 unique alleles including five novel alleles from the 253 individuals with high CPD and CPE (> 0.99999999999999999 and > 0.999999997 respectively). All loci from the new panel in the donor-recipient pair analysis showed higher than 50% informativity, while five loci from the commercial kit demonstrated lower than 50% informativity. Four loci from the new panel ranked the highest informativity. A sequenced allelic ladder which consists of 202 unique alleles from the 253 subjects was also developed to ensure accurate allele designation. The new 13-loci STR panel, thus, could serve as an additional powerful, accurate, and highly informative panel for chimerism analysis for HSCT patients.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  5. Amran F, Liow YL, Halim NAN
    J Korean Med Sci, 2018 Apr 23;33(17):e131.
    PMID: 29686599 DOI: 10.3346/jkms.2018.33.e131
    Leptospirosis is a febrile zoonotic disease. Routine diagnosis of leptospirosis is based on the detection of specific antibodies with serological tests. The aim of our study was to determine the usefulness of immunochromatographic assay (ICA), ImmuneMed Leptospira IgM Duo Rapid test kit from Korea, in rapid screening of acute leptospirosis in emergency cases with limited expertise. A total of 197 serum samples (93 positive, 104 negative) were selected randomly. The test has good diagnostic sensitivity 73% and specificity 90%. With positive predictive value of 87% and negative predictive value of 79%, this reassures patients have higher chance of correct diagnosis. This ICA is acceptable for screening of leptospirosis but confirmation with microscopic agglutination test should follow.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  6. Qin X, Rui J, Xia Y, Mu H, Song SH, Raja Aziddin RE, et al.
    Ann Lab Med, 2018 Mar;38(2):85-94.
    PMID: 29214751 DOI: 10.3343/alm.2018.38.2.85
    BACKGROUND: The immunosuppressant drugs (ISDs), tacrolimus and cyclosporine, are vital for solid organ transplant patients to prevent rejection. However, toxicity is a concern, and absorption is highly variable across patients; therefore, ISD levels need to be precisely monitored. In the Asia-Pacific (APAC) region, tacrolimus and cyclosporine concentrations are typically measured using immunoassays. The objective of this study was to assess the analytical performance of Roche Elecsystacrolimus and cyclosporinee electrochemiluminescence immunoassays (ECLIAs).

    METHODS: This evaluation was performed in seven centers across China, South Korea, and Malaysia. Imprecision (repeatability and reproducibility), assay accuracy, and lot-to-lot reagent variability were tested. The Elecsys ECLIAs were compared with commercially available immunoassays (Architect, Dimension, and Viva-E systems) using whole blood samples from patients with various transplant types (kidney, liver, heart, and bone marrow).

    RESULTS: Coefficients of variation for repeatability and reproducibility were ≤5.4% and ≤12.4%, respectively, for the tacrolimus ECLIA, and ≤5.1% and ≤7.3%, respectively, for the cyclosporine ECLIA. Method comparisons of the tacrolimus ECLIA with Architect, Dimension, and Viva-E systems yielded slope values of 1.01, 1.14, and 0.897, respectively. The cyclosporine ECLIA showed even closer agreements with the Architect, Dimension, and Viva-E systems (slope values of 1.04, 1.04, and 1.09, respectively). No major differences were observed among the different transplant types.

    CONCLUSIONS: The tacrolimus and cyclosporine ECLIAs demonstrated excellent precision and close agreement with other immunoassays tested. These results show that both assays are suitable for ISD monitoring in an APAC population across a range of different transplant types.

    Matched MeSH terms: Reagent Kits, Diagnostic
  7. Yunus MH, Tan Farrizam SN, Abdul Karim IZ, Noordin R
    Am J Trop Med Hyg, 2018 Jan;98(1):32-38.
    PMID: 29141740 DOI: 10.4269/ajtmh.17-0632
    Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara-positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.
    Matched MeSH terms: Reagent Kits, Diagnostic
  8. Situ SF, Ding CH, Nawi S, Johar A, Ramli R
    Malays J Pathol, 2017 Apr;39(1):25-31.
    PMID: 28413202 MyJurnal
    BACKGROUND: Chlamydia trachomatis and Neisseria gonorrhoeae are important bacterial pathogens of sexually transmitted infections (STIs) worldwide. This study sought to compare the analytical sensitivity and specificity of conventional methods against a rapid molecular method in detecting STIs caused by these bacteria.

    METHODS: Ninety five first-time male attendees of the Genito-urinary Medicine Clinic in Hospital Kuala Lumpur were included in this cross-sectional study. The detection of C. trachomatis was achieved through direct fluorescence antibody (DFA) staining of urethral swabs and real-time polymerase chain reaction testing (Xpert® CT/NG assay) on urine specimens. N. gonorrhoeae was detected through Gram staining and culture of urethral swabs and Xpert® CT/ NG assay on urine specimens.

    RESULTS: From the Xpert® CT/NG results, 11 (11.6%) attendees had chlamydia, 23 (24.2%) had gonorrhoea and 8 (8.4%) had both STIs. The sensitivity and specificity of DFA in detecting chlamydia compared to Xpert® CT/NG were 5.3% (95% CI: 0-28) and 94.7% (95% CI: 86-98), respectively. For gonorrhoea, the sensitivity and specificity of Gram staining were 90.3% (95% CI: 73-98) and 95.3% (86-99), respectively, whereas the sensitivity and specificity of culture compared to Xpert® CT/NG were 32.2% (95% CI: 17-51) and 100% (95% CI: 93-100), respectively.

    CONCLUSION: Although Gram-stained urethral swab smears are sensitive enough to be retained as a screening tool for gonorrhoea, culture as well as DFA lack sensitivity and are poorly suited to screen for gonorrhoea and chlamydia, respectively. However, owing to their high specificity, conventional detection methods are still suitable as confirmatory tests for gonorrhoea and chlamydia.

    Matched MeSH terms: Reagent Kits, Diagnostic
  9. Jahanshahi P, Sekaran SD, Adikan FR
    Med Biol Eng Comput, 2015 Aug;53(8):679-87.
    PMID: 25791696 DOI: 10.1007/s11517-015-1262-2
    Evaluation of binding between analytes and its relevant ligands on surface plasmon resonance (SPR) biosensor is of considerable importance for accurate determination and screening of an interference in immunosensors. Dengue virus serotype 2 was used as a case study in this investigation. This research work compares and interprets the results obtained from analytical analysis with the experimental ones. Both the theoretical calculations and experimental results are verified with one sample from each category of dengue serotypes 2 (low, mid, and high positive), which have been examined in the database of established laboratorial diagnosis. In order to perform this investigation, the SPR angle variations are calculated, analyzed, and then validated via experimental SPR angle variations. Accordingly, the error ratios of 5.35, 6.54, and 3.72% were obtained for the low-, mid-, and high-positive-specific immune globulins of patient serums, respectively. In addition, the magnetic fields of the biosensor are numerically simulated to show the effect of different binding mediums.
    Matched MeSH terms: Reagent Kits, Diagnostic/virology*
  10. Yoo SJ, Wang LL, Ning HC, Tao CM, Hirankarn N, Kuakarn S, et al.
    J Clin Virol, 2015 Mar;64:20-7.
    PMID: 25728074 DOI: 10.1016/j.jcv.2014.12.015
    Early diagnosis of hepatitis C virus (HCV) infection is essential to allow appropriate treatment and prevent transmission.
    Matched MeSH terms: Reagent Kits, Diagnostic
  11. Yatabe Y, Kerr KM, Utomo A, Rajadurai P, Tran VK, Du X, et al.
    J Thorac Oncol, 2015 Mar;10(3):438-45.
    PMID: 25376513 DOI: 10.1097/JTO.0000000000000422
    The efficacy of epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors in EGFR mutation-positive non-small-cell lung cancer (NSCLC) patients necessitates accurate, timely testing. Although EGFR mutation testing has been adopted by many laboratories in Asia, data are lacking on the proportion of NSCLC patients tested in each country, and the most commonly used testing methods.
    Matched MeSH terms: Reagent Kits, Diagnostic
  12. Jamaludin S, Mustaffa N, Che Hamzah NA, Syed Abdul Aziz SH, Lee YY
    BMC Gastroenterol, 2015;15:101.
    PMID: 26264957 DOI: 10.1186/s12876-015-0332-0
    Unchanged substrate in a negative rapid urease test may be reused to detect Helicobacter pylori (H. pylori). This could potentially reduce costs and wastage in low prevalence and resource-poor settings. We thus aimed to investigate the diagnostic accuracy of reused Pronto Dry and CLOtest kits, comparing this to the use of new Pronto Dry test kits and histopathological evaluation of gastric mucosal biopsies.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  13. Tan GW, Khoo AS, Tan LP
    Sci Rep, 2015;5:9430.
    PMID: 25800946 DOI: 10.1038/srep09430
    MicroRNAs regulate gene expression at the post-transcriptional level. Differential expression of miRNAs can potentially be used as biomarkers for early diagnosis and prediction for outcomes. Failure in validation of miRNA profiles is often caused by variations in experimental parameters. In this study, the performance of five extraction kits and three RT-qPCR systems were evaluated using BioMark high-throughput platform and the effects of different experimental parameters on circulating miRNA levels were determined. Differences in the performance of extraction kits as well as varying accuracy, sensitivity and reproducibility in qPCR systems were observed. Normalisation of RT-qPCR data to spike-in controls can reduce extraction bias. However, the extent of correlation for different qPCR systems varies in different assays. At different time points, there was no significant fold change in eight of the plasma miRNAs that we evaluated. Higher level of miRNAs was detected in plasma as compared to serum of the same cohort. In summary, we demonstrated that high-throughput RT-qPCR with pre-amplification step had increased sensitivity and can be achieved with accuracy and high reproducibility through stringent experimental controls. The information provided here is useful for planning biomarker validation studies involving circulating miRNAs.
    Matched MeSH terms: Reagent Kits, Diagnostic
  14. Hunsperger EA, Yoksan S, Buchy P, Nguyen VC, Sekaran SD, Enria DA, et al.
    PLoS Negl Trop Dis, 2014 Oct;8(10):e3171.
    PMID: 25330157 DOI: 10.1371/journal.pntd.0003171
    Commercially available diagnostic test kits for detection of dengue virus (DENV) non-structural protein 1 (NS1) and anti-DENV IgM were evaluated for their sensitivity and specificity and other performance characteristics by a diagnostic laboratory network developed by World Health Organization (WHO), the UNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (TDR) and the Pediatric Dengue Vaccine Initiative (PDVI). Each network laboratory contributed characterized serum specimens for the panels used in the evaluation. Microplate enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT formats) were represented by the kits. Each ELISA was evaluated by 2 laboratories and RDTs were evaluated by at least 3 laboratories. The reference tests for IgM anti-DENV were laboratory developed assays produced by the Armed Forces Research Institute for Medical Science (AFRIMS) and the Centers for Disease Control and Prevention (CDC), and the NS1 reference test was reverse transcriptase polymerase chain reaction (RT-PCR). Results were analyzed to determine sensitivity, specificity, inter-laboratory and inter-reader agreement, lot-to-lot variation and ease-of-use. NS1 ELISA sensitivity was 60-75% and specificity 71-80%; NS1 RDT sensitivity was 38-71% and specificity 76-80%; the IgM anti-DENV RDTs sensitivity was 30-96%, with a specificity of 86-92%, and IgM anti-DENV ELISA sensitivity was 96-98% and specificity 78-91%. NS1 tests were generally more sensitive in specimens from the acute phase of dengue and in primary DENV infection, whereas IgM anti-DENV tests were less sensitive in secondary DENV infections. The reproducibility of the NS1 RDTs ranged from 92-99% and the IgM anti-DENV RDTs from 88-94%.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  15. Andiappan H, Nissapatorn V, Sawangjaroen N, Chemoh W, Lau YL, Kumar T, et al.
    Parasit Vectors, 2014;7:239.
    PMID: 24886651 DOI: 10.1186/1756-3305-7-239
    Toxoplasmosis, being one of the TORCH's infections in pregnant women, is caused by Toxoplasma gondii, an obligate intracellular protozoan parasite. This parasitic infection in pregnancy congenitally causes severe outcomes to their fetus and newborn. This study aimed to determine the seroprevalence and stages of Toxoplasma infection in pregnant women and its associated risks exposures.
    Matched MeSH terms: Reagent Kits, Diagnostic
  16. Hussein NS, Sadiq SM, Kamaliah MD, Norakmal AW, Gohar MN
    Saudi J Kidney Dis Transpl, 2013 May;24(3):630-7.
    PMID: 23640651
    Urolithiasis is a common disease with increasing incidence and prevalence world-wide, probably more common in industrialized countries. The metabolic evaluation of 24-h urine collection has been considered as part of the management of urinary stone patients. The aim of this study was to evaluate the 24-h urine constituents in stone formers and its relation to demographic data in the northeast part of Peninsular Malaysia. One hundred and six patients were recruited in this study from two hospitals in the same geographical region; 96 patients fulfilled the inclusion criteria and an informed consent was obtained from all subjects. The 24-h urine was collected in sterile bottles with a preservative agent and calcium, oxalate, citrate, uric acid, magnesium and phosphate were tested using commercial kits on a Roche Hitachi 912 chemistry analyzer. The age (mean ± SD) of 96 patients was 56.45 ± 13.43 years and 82.3% of the patients were male while 17.7% were female. The 24-h urine abnormalities were hypercalciuria (14.5%), hyperoxaluria (61.4%), hypocitraturia (57.2%), hyperuricouria (19.7%), hypomagnesuria (59.3%) and hyperphosphaturia (12.5%). Hyperoxaluria (61.4%) was the most common abnormality detected during the analysis of 24-h urine constituents in contradiction to industrial countries, where hypercalciuria was the most common finding. The high frequencies of hypomagnesuria and hypocitraturia reflect the important role of magnesium and citrate in stone formation and their prophylactic role in the treatment of urinary stone disease in the given population.
    Matched MeSH terms: Reagent Kits, Diagnostic
  17. Loganathan R, Selvaduray KR, Nesaretnam K, Radhakrishnan AK
    Cell Prolif, 2013 Apr;46(2):203-13.
    PMID: 23510475 DOI: 10.1111/cpr.12014
    OBJECTIVES: Tocotrienols and tocopherols are members of the vitamin E family, with similar structures; however, only tocotrienols have been reported to achieve potent anti-cancer effects. The study described here has evaluated anti-cancer activity of vitamin E to elucidate mechanisms of cell death, using human breast cancer cells.

    MATERIALS AND METHODS: Anti-cancer activity of a tocotrienol-rich fraction (TRF) and a tocotrienol-enriched fraction (TEF) isolated from palm oil, as well as pure vitamin E analogues (α-tocopherol, α-, δ- and γ-tocotrienols) were studied using highly aggressive triple negative MDA-MB-231 cells and oestrogen-dependent MCF-7 cells, both of human breast cancer cell lines. Cell population growth was evaluated using a Coulter particle counter. Cell death mechanism, poly(ADP-ribose) polymerase cleavage and levels of NF-κB were determined using commercial ELISA kits.

    RESULTS: Tocotrienols exerted potent anti-proliferative effects on both types of cell by inducing apoptosis, the underlying mechanism of cell death being ascertained using respective IC50 concentrations of all test compounds. There was marked induction of apoptosis in both cell lines by tocotrienols compared to treatment with Paclitaxel, which was used as positive control. This activity was found to be associated with cleavage of poly(ADP-ribose) polymerase (a DNA repair protein), demonstrating involvement of the apoptotic cell death signalling pathway. Tocotrienols also inhibited expression of nuclear factor kappa-B (NF-κB), which in turn can increase sensitivity of cancer cells to apoptosis.

    CONCLUSION: Tocotrienols induced anti-proliferative and apoptotic effects in association with DNA fragmentation, poly(ADP-ribose) polymerase cleavage and NF-κB inhibition in the two human breast cancer cell lines.

    Matched MeSH terms: Reagent Kits, Diagnostic
  18. Hawkins R
    Ann Lab Med, 2013 Mar;33(2):156-8.
    PMID: 23479565 DOI: 10.3343/alm.2013.33.2.156
    Matched MeSH terms: Reagent Kits, Diagnostic
  19. Ng BK, Lim PS, Shafiee MN, Ghani NA, Ismail NA, Omar MH, et al.
    Biomed Res Int, 2013;2013:587438.
    PMID: 24073412 DOI: 10.1155/2013/587438
    Objective. To determine the diagnostic accuracy of placental alpha microglobulin-1 assay and standard diagnostic methods for detecting rupture of membrane. Study Design. Prospective diagnostic study, between June 2011 to November 2011 at a tertiary centre. Initial evaluation included both the standard diagnostic methods for rupture of membranes and placental alpha microglobulin-1 immunoassay. The actual rupture of membranes was diagnosed on review of the medical records after delivery (absence of membrane or a positive pad chart). Main Outcome Measures. Placental alpha microglobulin-1 immunoassay and standard diagnostic methods for diagnosis of rupture of membrane. Results. A total of 211 patients were recruited. At initial presentation, 187 patients (88.6%) had ruptured membranes, while 24 patients (11.4%) had intact membranes. Placental alpha microglobulin-1 immunoassay confirmed rupture of membranes at initial presentation with a sensitivity of 95.7% (179 of 187), specificity of 100% (24 of 24), positive predictive value of 100% (179 of 179), and negative predictive value of 75.0% (24 of 32). By comparison, the conventional standard diagnostic methods had a sensitivity of 78.1% (146 of 187), specificity of 100% (24 of 24), positive predictive value of 100% (146 of 146), and negative predictive value of 36.9% (24 of 65) in diagnosing rupture of membrane. Conclusion. Placental alpha-microglobulin-1 immunoassay is a rapid and accurate method for confirming the diagnosis of rupture of membrane. It was superior to conventional standard diagnostic methods (pooling, nitrazine, and ferning), the nitrazine test alone or fern test alone.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  20. Ng KL, Lee EL, Sani RA
    Trop Biomed, 2012 Mar;29(1):187-90.
    PMID: 22543620 MyJurnal
    This study was conducted to investigate the low prevalence of Dirofilaria immitis in dogs in Johor Bahru as reported by veterinary practitioners, using wet blood mount, Knott's Concentration Test and two heartworm antigen test kits (IDEXX Canine SNAP® 4Dx and RapiGEN®). This study also compared the two test kits used and determined the microfilaria species. Blood were collected from 100 owned dogs and 50 stray dogs in Johor Bahru via cephalic venipuncture. A thick blood smear was done and examined for samples that were positive for microfilaria species identification. The overall prevalence of D. immitis in dogs in Johor Bahru was 1.33% (2/150) and the microfilaria identified was D. immitis. The prevalence of heartworm in owned and stray dogs in this study was 1% and 2% respectively. With only one false negative result from RapiGEN® test kit, comparing the sensitivity between the two test kits could not be achieved. The low prevalence of D. immitis found in this study confirmed anecdotal evidence that prevalence of dirofilariasis is indeed low in Johor Bahru. Additionally, we speculate that dirofilariasis in dogs might be considered as an indicator of vector availability.
    Matched MeSH terms: Reagent Kits, Diagnostic