Displaying publications 1 - 20 of 286 in total

Abstract:
Sort:
  1. Zyoud SH, Daraghmeh DN, Mezyed DO, Khdeir RL, Sawafta MN, Ayaseh NA, et al.
    BMC Nephrol, 2016 04 27;17(1):44.
    PMID: 27117687 DOI: 10.1186/s12882-016-0257-z
    BACKGROUND: Haemodialysis (HD) is a life-sustaining treatment for patients with end-stage renal disease (ESRD). HD can bring about significant impairment in health-related quality of life (HRQOL) and outcomes. Therefore, we sought to describe the patterns of HRQOL and determine the independent factors associated with poor HRQOL in Palestinian patients on HD.

    METHODS: A multicenter cross-sectional study was performed from June 2014 to January 2015 using the EuroQOL-5 Dimensions instrument (EQ-5D-5L) for the assessment of HRQOL. ESRD patients undergoing HD in all dialysis centres in the West Bank of Palestine were approached and recruited for this study. Multiple linear regression was carried out to identify factors that were significantly associated with HRQOL.

    RESULTS: Two hundred and sixty-seven patients were participated in the current study giving response rate of 96 %. Overall, 139 (52.1 %) were male, and the mean ± standard deviation age was 53.3 ± 16.2 years. The reported HRQOL as measured by mean EQ-5D-5L index value and Euro QOL visual analogue scale (EQ-VAS) score was 0.37 ± 0.44 and 59.38 ± 45.39, respectively. There was a moderate positive correlation between the EQ-VAS and the EQ-5D-5L index value (r = 0.42, p 

    Matched MeSH terms: Renal Dialysis/psychology*; Renal Dialysis/trends
  2. Zyoud SH, Al-Jabi SW, Sweileh WM, Tabeeb GH, Ayaseh NA, Sawafta MN, et al.
    BMC Complement Altern Med, 2016 Jul 11;16:204.
    PMID: 27400742 DOI: 10.1186/s12906-016-1196-8
    Complementary and alternative medicine (CAM), and herbal therapies, are accepted worldwide, and have been important from medical, sociological and economic perspectives, among haemodialysis (HD) patients. The primary aim of this study was to evaluate the use of CAM among patients with end-stage renal disease (ESRD) who are undergoing HD.
    Matched MeSH terms: Renal Dialysis/statistics & numerical data*
  3. Zare-Zardini H, Amiri A, Shanbedi M, Taheri-Kafrani A, Kazi SN, Chew BT, et al.
    J Biomed Mater Res A, 2015 Sep;103(9):2959-65.
    PMID: 25690431 DOI: 10.1002/jbm.a.35425
    One of the novel applications of the nanostructures is the modification and development of membranes for hemocompatibility of hemodialysis. The toxicity and hemocompatibility of Ag nanoparticles and arginine-treated multiwalled carbon nanotubes (MWNT-Arg) and possibility of their application in membrane technology are investigated here. MWNT-Arg is prepared by amidation reactions, followed by characterization by FTIR spectroscopy, Raman spectroscopy, and thermogravimetric analysis. The results showed a good hemocompatibility and the hemolytic rates in the presence of both MWNT-Arg and Ag nanoparticles. The hemolytic rate of Ag nanoparticles was lower than that of MWNT-Arg. In vivo study revealed that Ag nanoparticle and MWNT-Arg decreased Hematocrit and mean number of red blood cells (RBC) statistically at concentration of 100 µg mL(-1) . The mean decrease of RBC and Hematocrit for Ag nanoparticles (18% for Hematocrit and 5.8 × 1,000,000/µL) was more than MWNT-Arg (20% for Hematocrit and 6 × 1000000/µL). In addition, MWNT-Arg and Ag nanoparticles had a direct influence on the White Blood Cell (WBC) drop. Regarding both nanostructures, although the number of WBC increased in initial concentration, it decreased significantly at the concentration of 100 µg mL(-1) . It is worth mentioning that the toxicity of Ag nanoparticle on WBC was higher than that of MWNT-Arg. Because of potent antimicrobial activity and relative hemocompatibility, MWNT-Arg could be considered as a new candidate for biomedical applications in the future especially for hemodialysis membranes.
    Matched MeSH terms: Renal Dialysis/adverse effects; Renal Dialysis/instrumentation
  4. Zamiah SAKS, Draman CR, Seman MR, Safhan AF, Rozalina R, Nik Ruzni NI
    Saudi J Kidney Dis Transpl, 2018 2 20;29(1):114-119.
    PMID: 29456216 DOI: 10.4103/1319-2442.225185
    Cardiovascular (CV) event is the most common cause of death in dialysis patients. Both traditional and nontraditional CV risk factors related to malnutrition, inflammation, and anemia are commonly found in this population. This study was conducted to evaluate the burden factors of CV risk factors and its management in our regularly dialyzed patients. It was a single-center, cross-sectional analysis of prevalent intermittent hemodialysis (IHD) and continuous ambulatory peritoneal dialysis (CAPD) patients followed up in our hospital. Both the traditional and non-traditional CV risk factors were recorded and compared between the two groups. Eighty-eight patients were recruited. Forty-five were treated with CAPD and 43 patients were treated with IHD. The mean age was 49.5 ± 15.17 years old and 54.5% were females. Eighty percent were Malay followed by Chinese (14.7%) and Indian (5.7%). Thirty-eight percent were hypertensive and 17% were diabetic. The mean age of CAPD patients was 48.9 ± 16.9 compared to 50 ± 13.5 years old for IHD patients (P > 0.05). The body mass index (BMI) of CAPD patients was 23.9 kg/m2 versus 21.7 kg/m2 of the IHD (P = 0.04). The systolic and diastolic blood pressure of CAPD patients were 158 and 89 mm Hg in comparison to 141 and 72 mm Hg in IHD patients (P <0.001) and their total and low-density lipoprotein cholesterol level were 5.93 mmol/L and 3.84 mmol/L versus 4.79 mmol/L and 2.52 mmol/L, respectively (P≤0.001). The CAPD patients were hyperglycemic more than IHD patients, although it was not statistically significant. All the nontraditional CV risk factors except serum albumin were comparable between the two groups. Serum albumin in CAPD patients was 35.5 g/L compared to 40.8 g/L in the IHD patients (P <0.001). In our prevalent dialysis-dependent patients, both traditional and non-traditional CV risk factors are common. Due to the prolonged and continuous glucose exposure from the peritoneal dialysis fluid, the CAPD patients had highly atherogenic serum, higher BMI, and intensified inflammation which pre-disposed them to higher CV events.
    Matched MeSH terms: Renal Dialysis/adverse effects*
  5. Zaman SU, Saif-Ur-Rehman, Zaman MKU, Rafiq S, Arshad A, Khurram MS, et al.
    Artif Organs, 2021 Nov;45(11):1377-1390.
    PMID: 34152645 DOI: 10.1111/aor.14020
    In the current study, a phase inversion scheme was employed to fabricate hydroxyapatite (HA)/polysulfone (PSF)-based asymmetric membranes using a film applicator with water as a solvent and nonsolvent exchanging medium. Fourier Transform Infrared (FTIR) and X-ray diffraction (XRD) spectroscopic studies were conducted to confirm the bonding chemistry and purity of filler. The inherent thick nature of PSF generated sponge-like shape while the instantaneous demixing process produced finger-like pore networks in HA/PSF-based asymmetric membranes as exhibited by scanning electron microscope (SEM) micrographs. The FTIR spectra confirmed noncovalent weak attractions toward the polymer surface. The leaching ratio was evaluated to observe the dispersion behavior of HA filler in membrane composition. Hydrophilicity, pore profile, pure water permeation (PWP) flux, and molecular weight cutoff (MWCO) values of all formulated membranes were also calculated. Antifouling results revealed that HA modified PSF membranes exhibited 43% less adhesion of bovine serum albumin (BSA) together with >86% recovery of flux. Membrane composition showed 74% total resistance, out of which 60% was reversible resistance. Biocompatibility evaluation revealed that the modified membranes exhibited prothrombin time (PT), and thrombin time (TT) comparable with typical blood plasma, whereas proliferation of living cells over membrane surface proved its nontoxic behavior toward biomedical application. The urea and creatinine showed effective adsorption aptitude toward HA loaded PSF membranes.
    Matched MeSH terms: Renal Dialysis/instrumentation
  6. Zakaria NF, Mohd Noor MT, Abdullah R
    BMC Complement Med Ther, 2021 Mar 16;21(1):94.
    PMID: 33726722 DOI: 10.1186/s12906-021-03268-4
    BACKGROUND: In the era of digital and improved conventional medicine, many continue to use traditional and complementary medicine (TCM). The prevalence of its usage is not well reported, especially in patients with end-stage kidney disease (ESKD) receiving haemodialysis, thus its benefits and adverse effects are not widely known. This study determines the prevalence, types, perceptions and factors associated with TCM use by chronic haemodialysis patients in Malaysia.

    METHODS: This is a multi-centre cross-sectional study involving patients undergoing haemodialysis treatment in Malaysia. A validated face-to-face questionnaire-based interview was conducted. Sociodemographic and clinical profiles of the patients, factors associated with TCM use, perceptions, sources of information, and disclosures to treating doctors were obtained. Data were analysed using SPSS software.

    RESULTS: A total of n = 329 participants were recruited. The mean age of the participants was 54.9 ± 12.5 years. The majority were Malays (72%) and females (54.7%). A total of 64.7% (n = 213) reported TCM use; n = 132 used TCM before the initiation of dialysis, while n = 81 used TCM after initiation. In the post-hoc analysis, patients who had never used TCM had a higher mean age (56.7 ± 12.3 years) than the patients who used TCM (51.1 ± 13.1) (p = 0.015) and were likely to have received primary education (p = 0.011). Unemployment was more likely to be associated with non-TCM use; with odds ratio 1.85 (95% CI: 1.15, 2.98). Biologically based therapy was found to be the most popular (97.2%) type of TCM, including herbal medicine (67.6%) and supplements (58.0%). Most respondents did not disclose their TCM use to their doctors (72.3%), and 41.8% had the perception that they felt better.

    CONCLUSIONS: TCM is widely used among chronic haemodialysis patients in Malaysia, mainly herbal medicine and supplements. Non-disclosure to healthcare professionals and a poor monitoring and regulation of its use in ESKD patients could be detrimental. Awareness needs to be raised among healthcare professionals and the general population.

    TRIAL REGISTRATION: The Ethics Committee for Research, University Putra Malaysia (13th March 2019). Reference: UPM/TNCPI/RMC/1.4.18.2 ( JKEUPM ).

    Matched MeSH terms: Renal Dialysis*
  7. Zailani MZ, Ismail AF, Sheikh Abdul Kadir SH, Othman MH, Goh PS, Hasbullah H, et al.
    J Biomed Mater Res A, 2017 05;105(5):1510-1520.
    PMID: 28000366 DOI: 10.1002/jbm.a.35986
    In this study, poly (1,8-octanediol citrate) (POC) was used to modify polyethersulfone (PES)-based membrane to enhance its hemocompatibility. Different compositions of POC (0-3%) were added into the polyethersulfone (PES) dope solutions and polyvinylpyrrolidone (PVP) was used as pore forming agent. The hemocompatible POC modified PES membranes were fabricated through phase-inversion technique. The prepared membranes were characterized using attenuated total reflectance-Fourier transform infrared (ATR-FTIR), thermogravimetric analysis (TGA), scanning electron microscopy (SEM), Atomic-force microscopy (AFM), contact angle, Zeta-potential, membrane porosity and pore size and pure water flux (PWF) and BSA rejection. The hemocompatibility of the modified PES membranes was evaluated by human serum fibrinogen (FBG) protein adsorption, platelet adhesion, activated partial thromboplastin time (APTT) and prothrombin time (PT), and thrombin-antithrombin III (TAT), complement (C3a and C5a) activation and Ca2+ absorption on membrane. Results showed that by increasing POC concentration, FBG adsorption was reduced, less platelets adhesion, prolonged APTT and PT, lower TAT, C5a and C3a activation and absorb more Ca2+ ion. These results indicated that modification of PES with POC has rendered improved hemocompatibility properties for potential application in the field of blood purification, especially in hemodialysis. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 1510-1520, 2017.
    Matched MeSH terms: Renal Dialysis/instrumentation; Renal Dialysis/methods
  8. Zahari KM, Mohamad Hatta NS, Ain Masnon N, Ch'ng LS
    BMJ Case Rep, 2023 Aug 29;16(8).
    PMID: 37643820 DOI: 10.1136/bcr-2023-254999
    We report a rare, potentially sight-threatening ocular complication due to central venous stenosis related to a previous site of haemodialysis catheter. A dialysis-dependent woman in her 60s presented with left eye redness for 1 month followed by a remarkably prominent vessel on the left upper eyelid for 2 weeks. Examinations found left eyelid oedema with prominent venous dilatation on the upper eyelid as well as left eye mild proptosis, conjunctiva injection with corkscrew vessels, raised intraocular pressure, and dilated and tortuous retina vessels. Central thoracic venogram showed total occlusion on the left brachiocephalic vein with retrograde reflux to the jugular vein. An endovascular percutaneous transluminal balloon angioplasty was performed for the left brachiocephalic vein stenosis, which resolved the orbital, facial and neck venous congestion. The patient remained asymptomatic after 1 year.
    Matched MeSH terms: Renal Dialysis
  9. Yusof Khan AHK, Zakaria NF, Zainal Abidin MA, Kamaruddin NA
    Medicine (Baltimore), 2021 Jul 30;100(30):e26729.
    PMID: 34397709 DOI: 10.1097/MD.0000000000026729
    Glycemic variability (GV) confers a significantly higher risk of diabetic-related complications, especially cardiovascular. Despite extensive research in this area, data on end-stage kidney disease (ESKD) patients on chronic hemodialysis are scarce. This study aims to determine the magnitude of GV among ESKD (diabetic vs nondiabetic) patients and its associated factors on hemodialysis days (HDD) and non-hemodialysis days (NHDD) where postulation of a higher GV observed among diabetic on HDD.We recruited 150 patients on hemodialysis, 93 patients with type 2 diabetic (DM-ESKD), and 57 with nondiabetic (NDM-ESKD). The GV indices (standard deviation [SD] and percentage coefficient variant [%CV]) were obtained from 11-point and 7-point self-monitoring blood glucose (fasting to post-meal) (SMBG) profiles on HDD and NHDD. The GV indices and its associated factors of both DM-ESKD and NDM-ESKD were analyzed to compare HDD vs NHDD.Mean blood glucose on HDD was 9.33 [SD 2.7, %CV 30.6%] mmol/L in DM-ESKD compared with 6.07 [SD 0.85, %CV 21.3%] mmol/L in NDM-ESKD (P = 
    Matched MeSH terms: Renal Dialysis*
  10. Yusof FA, Goh A, Azmi S
    Value Health, 2012 Jan-Feb;15(1 Suppl):S85-90.
    PMID: 22265073 DOI: 10.1016/j.jval.2011.11.024
    OBJECTIVES: To estimate a EQ-5D value set for Malaysia by using time trade-off (TTO) and visual analogue scale (VAS) valuation methods.
    METHODS: TTO and VAS valuations were obtained from face-to-face surveys of a convenience sample of patients, caregivers, and health professionals conducted at nine government hospitals in 2004 and 2005. Forty-five EQ-5D questionnaire health states were valued, divided into five sets of 15 health states. Analysis was conducted by using linear additive regression models applying N3 and D1 specifications. Model selection was based on criteria of coefficient properties, statistical significance, and goodness of fit.
    RESULTS: One hundred fifty-two respondents were interviewed, yielding 2174 TTO and 2265 VAS valuations. Respondents found TTO valuations to be more difficult than VAS valuations, and there were more inconsistencies in TTO valuations. All the independent variables in the models were statistically significant and consistent with expected signs and magnitude, except for the D1 specification modeled on TTO valuations. The N3 model provided the best fit for the VAS valuation data, with a mean absolute error of 0.032.
    CONCLUSION: This study provides a Malaysian EQ-5D questionnaire value set that can be used for cost-utility studies despite survey limitations.
    Study site: convenience sampling from three categories of respondents (patients undergoing dialysis, patients’ carers, and dialysis center staff) from public hospitals
    Matched MeSH terms: Renal Dialysis
  11. Yew KL, Anderson S, Farah R, Lim SH
    Asian Cardiovasc Thorac Ann, 2014 Oct;22(8):979-80.
    PMID: 24887840 DOI: 10.1177/0218492313491583
    Central vein stenosis is not uncommon in hemodialysis-dependent patients as a result of mechanical damage to the vessel walls from prior cannulation. It can cause ipsilateral upper limb swelling and pain, resulting in suboptimal hemodialysis. It is unfortunate for bilateral central vein stenosis to develop concomitantly, and rare in the setting of an in-situ pacemaker. This case illustrates the successful ligation of a nondependent left arteriovenous fistula and stenting of the right subclavian vein with functioning ipsilateral arteriovenous fistula, to overcome the problem of symptomatic bilateral upper limb swelling.
    Matched MeSH terms: Renal Dialysis*
  12. Yang SC, Mustafar R, Kamaruzaman L, Wei Yen K, Mohd R, Cader R
    Acta Med Indones, 2019 Oct;51(4):338-343.
    PMID: 32041918
    A 59-year-old lady with underlying hypothyroidism presented with acute contact dermatitis progressed to cellulitis with superimposed bacterial infection and acute kidney injury. She responded to initial management with antibiotics, but a week later, she had cutaneous and systemic vasculitis. Her skin biopsy consistent with immune-mediated leuko-cytoclastic vasculitis and her blood test was positive for cytoplasmic-anti-neutrophil cytoplasmic antibody (c-ANCA). A diagnosis of ANCA-associated vasculitis was made and she was treated with immunosuppressant with plasmapheresis and hemodialysis support for her kidney failure. Despite aggressive measures, the patient succumbed to her illness. This case report demonstrates that soft tissue infection could trigger the development of ANCA-associated vasculitis whilst a background of hypothyroidism serves as a predisposing factor as both condition were reported separately in a couple of case studies before.
    Matched MeSH terms: Renal Dialysis
  13. Xue Meng Lim, Christopher Thiam Seong Lim
    MyJurnal
    Diabetic ketoacidosis (DKA) is a medical emergency which requires prompt management to prevent mortality. Treat- ment is complicated in end stage renal failure (ESRF) patients due to their altered physiology in sugar metabolism and fluid haemodynamics. To date, there are only a few case reports illustrating the presentation and management of DKA in ESRF patients and a definite guideline on treatment of DKA in ESRF is seriously lacking. We report here a case of an ESRF patient on maintenance haemodialysis, who develops DKA due to missed insulin, and outline our successful treatment plan. We hope our reported case report research can further contribute to the knowledge of DKA management in ESRF.
    Matched MeSH terms: Renal Dialysis
  14. Xiao Hong C, Abd Wahab S, Azman M
    BMJ Case Rep, 2020 Oct 27;13(10).
    PMID: 33109696 DOI: 10.1136/bcr-2020-236484
    Penetrating foreign body in the head and neck can be catastrophic from injury to the constellation of vascular and neural structures in the neck. Early recognition and prompt surgical intervention is imperative to save lives. Herein, we present an unusual case of iatrogenic foreign body-a coiled guidewire embedded in the deep neck space. The complications, radiological investigation and multidisciplinary surgical management are further discussed.
    Matched MeSH terms: Renal Dialysis/adverse effects*
  15. Wong XZ, Gan CC, Mohamed R, Yahya R, Ganapathy S, Tan SS, et al.
    BMC Nephrol, 2020 11 13;21(1):480.
    PMID: 33187498 DOI: 10.1186/s12882-020-02154-4
    BACKGROUND: Hepatitis C virus (HCV) infects more than 71 million people worldwide and chronic HCV infection increases the risk of liver cirrhosis and failure. Haemodialysis (HD) is one of the renal replacement therapies with risk of HCV transmission. Anti-HCV antibodies are the serological screening test for HCV infection that does not detect active phase of infection. Majority HCV infected HD patients in Malaysia do not have further HCV RNA performed due to high cost and thus HCV treatment is less frequently offered. HCV Core Antigen (HCV Ag) can potentially be used to diagnose active HCV infection in HD population in comparison to HCV RNA, at lower cost.

    METHODS: We conducted a cross-sectional study to assess the correlation between HCV Ag and HCV RNA and to identify the prevalence of active HCV infection among HCV seropositive HD patients from dialysis centres across West Malaysia from July 2019 to May 2020. Pre-dialysis blood was taken and tested for both HCV Ag and HCV RNA tests. HCV Ag was tested with Abbott ARCHITECT HCV Ag test.

    RESULTS: We recruited 112 seropositive HD patients from 17 centres with mean age of 54.04 ± 11.62 years, HD vintage of 14.1 ± 9.7 years, and male constitute 59.8% (67) of the study population. HCV Ag correlates well with HCV RNA (Spearman test coefficient 0.833, p  3000 IU/mL, HCV Ag had a higher sensitivity of 95.1% and greater correlation (Spearman test coefficient 0.897, p 

    Matched MeSH terms: Renal Dialysis
  16. Wong XZ, Amirah A, Gan CC, Fatiha S, Maznah D, Yahya R, et al.
    Nephrology (Carlton), 2021 May;26(5):463-470.
    PMID: 33580732 DOI: 10.1111/nep.13862
    AIMS: In Malaysia, majority anti-HCV positive haemodialysis patients do not undergo hepatitis C confirmation due to the high cost of HCV RNA. HCV Core Antigen might be a cost-effective diagnostic test to identify HD patients who have active HCV infection eligible for Direct Acting Anti-viral therapy.

    METHODS: A cross-sectional study was conducted to assess the correlation between HCV Ag and HCV RNA and the cost implications of different diagnostic algorithms to diagnose active HCV infection using Anti-HCV, HCV Ag, and HCV RNA. Pre-dialysis blood was tested for both HCV Ag and HCV RNA. HCV Ag was tested with Abbott ARCHITECT HCV Ag test.

    RESULTS: Two-hundred twenty-seven haemodialysis patients were recruited from 20 centres with mean age of 57.68 ± 12.48 years, and male constitutes 56.8% (129) of the study population. HCV Ag correlated well with HCV RNA (Spearman test coefficient 0.943, p 

    Matched MeSH terms: Renal Dialysis*
  17. Wong WK, Chan WK, Ganapathy SS, Lim SK
    Semin Dial, 2023 Mar;36(2):107-116.
    PMID: 35821201 DOI: 10.1111/sdi.13117
    BACKGROUND: Metabolic-dysfunction-associated fatty liver disease (MAFLD) and end stage kidney disease (ESKD) are complications of the metabolic syndrome. Our aim is to study the prevalence of MAFLD and advanced liver fibrosis and the associated factors among hemodialysis patients in a multiracial urban population in Malaysia.

    METHODS: A cross-sectional study of hemodialysis patients from 10 hemodialysis centers was used. FibroTouch examination was performed on all patients. Fatty liver was diagnosed based on ultrasound attenuation parameter ≥248 dB/m while advanced liver fibrosis was diagnosed based on liver stiffness measurement ≥10 kPa.

    RESULTS: This study included 447 hemodialysis patients (median age 59 [50-67], male 55%, Chinese 61%, Malay 20%, Indian 18%). Dialysis vintage was 49 (22-93) months. The prevalence of MAFLD was 43.4%. Independent factors associated with MAFLD were elevated waist circumference (aOR = 10.1, 95% CI = 5.3-19.4, p 

    Matched MeSH terms: Renal Dialysis*
  18. Wong WK, Chan WK, Ganapathy S, Lim SK
    Nephrology (Carlton), 2023 Aug;28(8):425-433.
    PMID: 37269220 DOI: 10.1111/nep.14186
    AIM: This study aims to determine if metabolic-dysfunction-associated fatty liver disease (MAFLD) or advanced liver fibrosis is associated with erythropoietin stimulating agent (ESA) hypo-responsiveness in hemodialysis patients.

    METHODS: In a cross-sectional study of 379 hemodialysis patients, FibroTouch transient elastography was performed on all patients. Erythropoeitin resistance index (ERI) was used to measure the responsiveness to ESA. Patients in the highest tertile of ERI were considered as having ESA hypo-responsiveness.

    RESULTS: The percentage of patients with ESA hypo-responsiveness who had MAFLD was lower than patients without ESA hypo-responsiveness. FIB-4 index was significantly higher in ESA hypo-responsive patients. In multivariate analysis, female gender (aOR = 3.4, 95% CI = 1.9-6.2, p < 0.001), dialysis duration ≥50 months (aOR = 1.8, 95% CI = 1.1-2.9, p < 0.05), elevated waist circumference (aOR = 0.4, 95% CI = 0.2-0.8, p = 0.005), low platelet (aOR = 2.6, 95% CI 1.3-5.1, p < 0.01), elevated total cholesterol (aOR = 0.5, 95% CI 0.3-0.9, p < 0.05) and low serum iron (aOR = 3.8, 95% CI = 2.3-6.5, p < 0.001) were found to be independent factors associated with ESA hypo-responsiveness. Neither MAFLD nor advanced liver fibrosis was independently associated with ESA hypo-responsiveness. However, every 1 kPA increase in LSM increased the chance of ESA-hyporesponsiveness by 13% (aOR = 1.1, 95% CI =  1.0-1.2, p = 0.002) when UAP and LSM were used instead of presence of MAFLD and advanced liver fibrosis, respectively.

    CONCLUSION: MAFLD and advanced liver fibrosis were not independently associated with ESA hypo-responsiveness. Nevertheless, higher FIB-4 score in ESA hypo-responsive group and significant association between LSM and ESA hypo-responsiveness suggest that liver fibrosis may be a potential clinical marker of ESA hypo-responsiveness.

    Matched MeSH terms: Renal Dialysis/adverse effects
  19. Wong SW, Chan YM, Lim TS
    Malays J Nutr, 2011 Dec;17(3):277-86.
    PMID: 22655450 MyJurnal
    There is mounting evidence demonstrating the importance of adequate physical activity to promote better well-being among hemodialysis patients. Available data pertaining to the levels of physical activity and its determinants among hemodialysis patients is, however, scarce in Malaysia. The objectives of this study are hence to determine the levels of physical activity and it associated factors among hemodialysis patients.
    Matched MeSH terms: Renal Dialysis*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links