BACKGROUND: AVFs are preferred for haemodialysis access but are limited by high rates of early failure.
METHODS: A post hoc analysis of 353 participants from ANZ and Malaysia included in the FAVOURED randomised-controlled trial undergoing de novo AVF surgery was performed. Composite AVF failure (thrombosis, abandonment, cannulation failure) and its individual components were compared between ANZ (n = 209) and Malaysian (n = 144) participants using logistic regression adjusted for patient- and potentially modifiable clinical factors.
RESULTS: Participants' mean age was 55 ± 14.3 years and 64% were male. Compared with ANZ participants, Malaysian participants were younger with lower body mass index, higher prevalence of diabetes mellitus and lower prevalence of cardiovascular disease. AVF failure was less frequent in the Malaysian cohort (38% vs 54%; adjusted odds ratio (OR) 0.53, 95% confidence interval (CI) 0.31-0.93). This difference was driven by lower odds of cannulation failure (29% vs 47%, OR 0.45, 95% CI 0.25-0.80), while the odds of AVF thrombosis (17% vs 20%, OR 1.24, 95% CI 0.62-2.48) and abandonment (25% vs 23%, OR 1.17, 95% CI 0.62-2.16) were similar.
CONCLUSIONS: The risk of AVF failure was significantly lower in Malaysia compared to ANZ and driven by a lower risk of cannulation failure. Differences in practice patterns, including patient selection, surgical techniques, anaesthesia or cannulation techniques may account for regional outcome differences and warrant further investigation.
METHODS: A multicentered, open-label, parallel group, prospective randomized controlled trial among patients suffering from CKD-associated pruritus with sleep disturbance, after randomization into control, and intervention group to be held at North West General Hospital and Research Center Peshawar, Pakistan and Institute of Kidney Diseases Peshawar, Pakistan.
RESULTS: The primary outcome is to investigate the effectiveness of zolpidem 10 mg and acupressure therapy on foot acupoints to improve the sleep quality and overall quality of life among hemodialysis patients suffering from CKD-associated pruritus. After baseline assessment by Urdu version of 5D itch scale and Urdu version of Pittsburgh Sleep Quality Index (PSQI) and Urdu EQ-5D 3L, the intervention group will be given zolpidem 10 mg oral tablets and control group with acupressure on both foots on KI-1 acupoints for total of 6 minutes. Assessment will be done at weeks 4 and 8 from baseline by using Urdu version of 5D itch scale and Urdu version of PSQI and Urdu EQ-5D 3L, whereas safety profiling of zolpidem 10 mg tablet at week 6 from baseline and acupressure acceptability at week 6 from baseline. Analysis of covariance will be used to examine the differences in treatment effects between the intervention and control groups.
CONCLUSION: Improvement of sleep quality and quality of life among patients with CKD-associated pruritus requires great importance. This study aims to improve the quality of sleep and quality of life among patients with hemodialysis suffering from CKD-associated pruritus.
METHODS: We conducted an 8-week randomized crossover study on 16 Hemodialysis machines to compare CCS versus PPC. Performance is assessed by solute concentrations while safety is assessed by microbial count, endotoxin level and adverse event reporting.
RESULTS: Microbial counts and endotoxin levels were monitored on 48 occasions during the 8-week study for the CCS arm of the study. The levels were all below the action limit during the study. No patient reported any adverse events. Dialysate Sodium, Chloride and Bicarbonate concentrations were measured on a total of 128 occasions for each arm of the study. The relative deviations of Sodium, Chloride and Bicarbonate concentration were within ±5% of their nominal values for both. The 95% Confidence Intervals for the ratio of the mean solute concentrations on the CCS to PPC lie within the tolerance limit of ±5%.
CONCLUSION: Modern CCS is bacteriologically safe and its performance statistically equivalent to PPC.
METHODS AND MATERIALS: A retrospective cross-sectional study involving 80 haemodialysis (HD) patients recruited from March 2020 till March 2021. Patients' information and results was retrieved and evaluated. Risk factors affecting the COVID-19 mortality were analysed using a one-way analysis of variance (ANOVA) and binary logistic regression.
RESULTS: The mean age of the patients was 54 years who were predominantly Malays (87.5%) and living in rural areas. Majority of them had comorbidities such as diabetes mellitus (71%) and hypertension (90%). The most common presentations were fever (46%) and cough (54%) with chest radiographs showing bilateral lower zone ground glass opacities (45%). A quarter of the study population were admitted to the intensive care unit, necessitating mechanical ventilation. This study found that 51% of the patients were given steroids and 45% required oxygen supplementation. The COVID-19 infection mortality among the study population was 12.5%. Simple logistic regression analysis showed that albumin, Odd Ratio, OR=0.85 (95% Confidence Interval, 95%CI: 0.73, 0.98)) and absolute lymphocyte count OR=0.08 (95%CI: 0.11, 0.56) have inverse association with COVID-19 mortality. C-reactive protein OR=1.02 (95%CI: 1.01, 1.04), lactate dehydrogenase OR=1.01 (95%CI: 1.00, 1.01), mechanical ventilation OR=17.21 (95%CI: 3.03, 97.67) and high dose steroids OR=15.71 (95%CI: 1.80, 137.42) were directly associated with COVID-19 mortality.
CONCLUSION: The high mortality rate among ESKD patients receiving HD was alarming. This warrants additional infection control measures to prevent the spread of COVID- 19 infection among this vulnerable group of patients. Expediting vaccination efforts in this group of patients should be advocated to reduce the incidence of complications from COVID-19 infection.