Displaying publications 1 - 20 of 1991 in total

Abstract:
Sort:
  1. Zanudin A, Mercer TH, Jagadamma KC, van der Linden ML
    Gait Posture, 2017 10;58:30-40.
    PMID: 28711651 DOI: 10.1016/j.gaitpost.2017.07.005
    Availability of outcome measures (OMs) with robust psychometric properties is an essential prerequisite for the evaluation of interventions designed to address gait deterioration in young people with Cerebral Palsy (CP). This review evaluates evidence for the reliability, validity and responsiveness of outcome measures of gait quality and walking performance in young people with CP. A systematic search was performed in MEDLINE, CINAHL, PubMed and Scopus. Articles that met the eligibility criteria were selected. Methodological quality of studies was independently rated by two raters using the modified COnsensus-based Standard for the selection of health status Measurement INstruments checklist. Strength of evidence was rated using standardised guidelines. Best evidence synthesis was scored according to Cochrane criteria. Fifty-one articles reporting on 18 distinct OMs were included for review. Best evidence synthesis indicated a moderate to strong evidence for the reliability for OMs of walking performance but conflicting evidence for the reliability of OMs of gait quality. The evidence for responsiveness for all OMs included in this review was rated as 'unknown'. The limitations of using the modified COSMIN scoring for small sample sizes are acknowledged. Future studies of high methodological quality are needed to explore the responsiveness of OMs assessing gait quality and walking performance in young people with CP.
    Matched MeSH terms: Reproducibility of Results
  2. Whitton C, Ho JCY, Tay Z, Rebello SA, Lu Y, Ong CN, et al.
    Nutrients, 2017 Sep 25;9(10).
    PMID: 28946670 DOI: 10.3390/nu9101059
    The assessment of diets in multi-ethnic cosmopolitan settings is challenging. A semi-quantitative 163-item food frequency questionnaire (FFQ) was developed for the adult Singapore population, and this study aimed to assess its reproducibility and relative validity against 24-h dietary recalls (24 h DR) and biomarkers. The FFQ was administered twice within a six-month interval in 161 adults (59 Chinese, 46 Malay, and 56 Indian). Fasting plasma, overnight urine, and 24 h DR were collected after one month and five months. Intra-class correlation coefficients between the two FFQ were above 0.70 for most foods and nutrients. The median correlation coefficient between energy-adjusted deattenuated FFQ and 24 h DR nutrient intakes was 0.40 for FFQ1 and 0.39 for FFQ2, highest for calcium and iron, and lowest for energy and carbohydrates. Significant associations were observed between urinary isoflavones and soy protein intake (r = 0.46), serum carotenoids and fruit and vegetable intake (r = 0.34), plasma eicosapentaenoic acid and docosahexaenoic acid (EPA + DHA) and fish/seafood intake (r = 0.36), and plasma odd chain saturated fatty acids (SFA) and dairy fat intake (r = 0.25). Associations between plasma EPA + DHA and fish/seafood intake were consistent across ethnic groups (r = 0.28-0.49), while differences were observed for other associations. FFQ assessment of dietary intakes in modern cosmopolitan populations remains feasible for the purpose of ranking individuals' dietary exposures in epidemiological studies.
    Matched MeSH terms: Reproducibility of Results
  3. Vaingankar JA, Subramaniam M, Tan LWL, Abdin E, Lim WY, Wee HL, et al.
    BMC Med Res Methodol, 2018 03 15;18(1):29.
    PMID: 29544448 DOI: 10.1186/s12874-018-0487-9
    BACKGROUND: Measures of mental well-being and positive mental health (PMH) have been largely developed and used in Western populations, however, data on representative Asian communities are lacking. Using data from a population sample, this study sought to establish psychometric properties and norms of the PMH Instrument (PMH-I), a measure of positive mental health developed in Singapore.

    METHODS: We conducted a nationally representative survey among 1925 adults aged 18-79 years of Chinese, Malay, Indian or other ethnicity. Participants reported socio-demographic characteristics and completed the PMH-I along with measures of health-related quality of life (HRQoL) and psychological distress. Construct validity of the PMH-I was assessed using confirmatory factor analysis and concurrent validity was tested through correlation with other psychological measures. Normative PMH values and differences in population subgroups were estimated.

    RESULTS: The six-factor-higher-order structure of the PMH-I comprising six subscales of general coping, emotional support, spirituality, interpersonal skills, personal growth and autonomy and global affect was confirmed. Concurrent validity was shown through significant positive correlation of the total PMH score and its subscales with HRQoL and an inverse correlation with psychological distress. Weighted age, gender and ethnicity-specific norms were derived for the Singapore population. Total PMH was significantly higher in participants aged over 40 years as compared with 18-29 year olds and in non-Chinese ethnic groups as compared with Chinese. These differences were observed for all PMH-I subscales, with the exception of emotional support and interpersonal skills score differences by age. In contrast, gender, marital status, and education level were significantly associated with some of the subscales, but not with total PMH.

    CONCLUSIONS: These results support the psychometric properties of the PMH-I in a multi-ethnic Asian population sample. The generalizable population-based norms support the application of the PMH-I for measuring mental health and assessing its determinants within the Singapore general population.

    Matched MeSH terms: Reproducibility of Results
  4. Maiwall R, Sarin SK, Kumar S, Jain P, Kumar G, Bhadoria AS, et al.
    Liver Int, 2017 Oct;37(10):1497-1507.
    PMID: 28393476 DOI: 10.1111/liv.13443
    BACKGROUND AND AIM: There is limited data on predictors of acute kidney injury in acute on chronic liver failure. We developed a PIRO model (Predisposition, Injury, Response, Organ failure) for predicting acute kidney injury in a multicentric cohort of acute on chronic liver failure patients.

    PATIENTS AND METHODS: Data of 2360 patients from APASL-ACLF Research Consortium (AARC) was analysed. Multivariate logistic regression model (PIRO score) was developed from a derivation cohort (n=1363) which was validated in another prospective multicentric cohort of acute on chronic liver failure patients (n=997).

    RESULTS: Factors significant for P component were serum creatinine[(≥2 mg/dL)OR 4.52, 95% CI (3.67-5.30)], bilirubin [(<12 mg/dL,OR 1) vs (12-30 mg/dL,OR 1.45, 95% 1.1-2.63) vs (≥30 mg/dL,OR 2.6, 95% CI 1.3-5.2)], serum potassium [(<3 mmol/LOR-1) vs (3-4.9 mmol/L,OR 2.7, 95% CI 1.05-1.97) vs (≥5 mmol/L,OR 4.34, 95% CI 1.67-11.3)] and blood urea (OR 3.73, 95% CI 2.5-5.5); for I component nephrotoxic medications (OR-9.86, 95% CI 3.2-30.8); for R component,Systemic Inflammatory Response Syndrome,(OR-2.14, 95% CI 1.4-3.3); for O component, Circulatory failure (OR-3.5, 95% CI 2.2-5.5). The PIRO score predicted acute kidney injury with C-index of 0.95 and 0.96 in the derivation and validation cohort. The increasing PIRO score was also associated with mortality (P

    Matched MeSH terms: Reproducibility of Results
  5. van Langeveld AWB, Teo PS, Mars M, Feskens EJM, de Graaf C, de Vries JHM
    Eur J Clin Nutr, 2019 01;73(1):132-140.
    PMID: 30254242 DOI: 10.1038/s41430-018-0300-1
    BACKGROUND/OBJECTIVE: Taste is of key importance in food choice and dietary patterns, but studies on taste profiles are limited. We previously assessed dietary taste patterns by 24 h recalls (24hR), but for epidemiological studies food frequency questionnaires (FFQ) may also be suitable. This study compared dietary taste patterns based on FFQ against 24hR and biomarkers of exposure.

    SUBJECTS/METHODS: A taste database including 467 foods' sweet, sour, bitter, salt, umami and fat sensation values was combined with food intake data to assess dietary taste patterns: the contribution to energy intake of 6 taste clusters. The FFQ's reliability was assessed against 3-d 24hR and urinary biomarkers for sodium (Na) and protein intake (N) in Dutch men (n = 449) and women (n = 397) from the NQplus validation study (mean age 53 ± 11 y, BMI 26 ± 4 kg/m2).

    RESULTS: Correlations of dietary taste patterns ranged from 0.39-0.68 between FFQ and 24hR (p 

    Matched MeSH terms: Reproducibility of Results
  6. Ebrahimkhani S, Jaward MH, Cicuttini FM, Dharmaratne A, Wang Y, de Herrera AGS
    Artif Intell Med, 2020 06;106:101851.
    PMID: 32593389 DOI: 10.1016/j.artmed.2020.101851
    In this paper, we review the state-of-the-art approaches for knee articular cartilage segmentation from conventional techniques to deep learning (DL) based techniques. Knee articular cartilage segmentation on magnetic resonance (MR) images is of great importance in early diagnosis of osteoarthritis (OA). Besides, segmentation allows estimating the articular cartilage loss rate which is utilised in clinical practice for assessing the disease progression and morphological changes. It has been traditionally applied in quantifying longitudinal knee OA progression pattern to detect and assess the articular cartilage thickness and volume. Topics covered include various image processing algorithms and major features of different segmentation techniques, feature computations and the performance evaluation metrics. This paper is intended to provide researchers with a broad overview of the currently existing methods in the field, as well as to highlight the shortcomings and potential considerations in the application at clinical practice. The survey showed that state-of-the-art techniques based on DL outperform the other segmentation methods. The analysis of the existing methods reveals that integration of DL-based algorithms with other traditional model-based approaches has achieved the best results (mean Dice similarity coefficient (DSC) between 85.8% and 90%).
    Matched MeSH terms: Reproducibility of Results
  7. Shanmugam S, Nathan AM, Zaki R, Tan KE, Eg KP, Thavagnanam S, et al.
    BMC Pediatr, 2016 06 23;16:80.
    PMID: 27339265 DOI: 10.1186/s12887-016-0616-8
    BACKGROUND: Noisy breathing is a common presenting symptom in children. The purpose of this study is to (a) assess parental ability to label wheeze, (b) compare the ability of parents of children with and without asthma to label wheeze and (c) determine factors affecting parental ability to label wheeze correctly.

    METHODS: This cross-sectional study in a tertiary hospital in Kuala Lumpur, Malaysia involved parents of children with asthma. Parents of children without asthma were the control group. Eleven validated video clips showing wheeze, stridor, transmitted noises, snoring or normal breathing were shown to the parents. Parents were asked, in English or Malay, "What do you call the sound this child is making?" and "Where do you think the sound is coming from?"

    RESULTS: Two hundred parents participated in this study: 100 had children with asthma while 100 did not. Most (71.5 %) answered in Malay. Only 38.5 % of parents correctly labelled wheeze. Parents were significantly better at locating than labelling wheeze (OR 2.4, 95 % CI 1.64-3.73). Parents with asthmatic children were not better at labelling wheeze than those without asthma (OR1.04, 95 % CI 0.59-1.84). Answering in English (OR 3.4, 95 % CI 1.69-7.14) and having older children with asthma (OR 9.09, 95 % CI 3.13-26.32) were associated with correct labelling of wheeze. Other sounds were mislabelled as wheeze by 16.5 % of respondents.

    CONCLUSION: Parental labelling of wheeze was inaccurate especially in the Malay language. Parents were better at identifying the origin of wheeze rather than labelling it. Physicians should be wary about parental reporting of wheeze as it may be inaccurate.

    Matched MeSH terms: Reproducibility of Results
  8. Nathan AM, Zaki R, Rozario R, Dhania N, Mohd Hamirudin SN, Eg KP, et al.
    PMID: 26338016 DOI: 10.1186/s12955-015-0336-z
    The Canadian Acute Respiratory Illness and Flu Scale (CARIFS) is a parent-proxy questionnaire that assesses severity of acute respiratory infections in children. The aim was to (a) perform a cross-cultural adaptation and (b) prove that the Malay CARIFS is a reliable tool.
    Matched MeSH terms: Reproducibility of Results
  9. Gan HS, Tan TS, Wong LX, Tham WK, Sayuti KA, Abdul Karim AH, et al.
    Biomed Mater Eng, 2014;24(6):3145-57.
    PMID: 25227024 DOI: 10.3233/BME-141137
    In medical image segmentation, manual segmentation is considered both labor- and time-intensive while automated segmentation often fails to segment anatomically intricate structure accordingly. Interactive segmentation can tackle shortcomings reported by previous segmentation approaches through user intervention. To better reflect user intention, development of suitable editing functions is critical. In this paper, we propose an interactive knee cartilage extraction software that covers three important features: intuitiveness, speed, and convenience. The segmentation is performed using multi-label random walks algorithm. Our segmentation software is simple to use, intuitive to normal and osteoarthritic image segmentation and efficient using only two third of manual segmentation's time. Future works will extend this software to three dimensional segmentation and quantitative analysis.
    Matched MeSH terms: Reproducibility of Results
  10. Ali AQ, Md Sultan AB, Abd Ghani AA, Zulzalil H
    PeerJ Comput Sci, 2020;6:e294.
    PMID: 33816945 DOI: 10.7717/peerj-cs.294
    Despite the benefits of standardization, the customization of Software as a Service (SaaS) application is also essential because of the many unique requirements of customers. This study, therefore, focuses on the development of a valid and reliable software customization model for SaaS quality that consists of (1) generic software customization types and a list of common practices for each customization type in the SaaS multi-tenant context, and (2) key quality attributes of SaaS applications associated with customization. The study was divided into three phases: the conceptualization of the model, analysis of its validity using SaaS academic-derived expertise, and evaluation of its reliability by submitting it to an internal consistency reliability test conducted by software-engineer researchers. The model was initially devised based on six customization approaches, 46 customization practices, and 13 quality attributes in the SaaS multi-tenant context. Subsequently, its content was validated over two rounds of testing after which one approach and 14 practices were removed and 20 practices were reformulated. The internal consistency reliability study was thereafter conducted by 34 software engineer researchers. All constructs of the content-validated model were found to be reliable in this study. The final version of the model consists of 6 constructs and 44 items. These six constructs and their associated items are as follows: (1) Configuration (eight items), (2) Composition (four items), (3) Extension (six items), 4) Integration (eight items), (5) Modification (five items), and (6) SaaS quality (13 items). The results of the study may contribute to enhancing the capability of empirically analyzing the impact of software customization on SaaS quality by benefiting from all resultant constructs and items.
    Matched MeSH terms: Reproducibility of Results
  11. Mohd Aizam Talib, Nor Asiah Muhamad, Zulkurnain Abdul Malek
    MyJurnal
    Preventive tests and diagnosis of in-service power transformer are important for early fault prediction and increased reliability of electricity supply. However, some existing diagnostic techniques require transformer outage before the measurement can be performed and need expert knowledge and experiences to interpret the measurement results. Other measurement techniques such as chemical analyses of insulating oil may cause significant variance to measurement results due to different practices in oil sampling, storage, handling and transportation of oil. A cost-effective measuring technique, which is simple, providing fast and an accurate measurement results, is therefore highly required. The extended application of Polarisation and Depolarisation (PDC) measurement for characterisation of different faults conditions in-service power transformer has been presented in this paper. Earlier studies on polarisation and depolarisation current of oil samples from in-service power transformer shows that depolarisation has provided significant information about the change of material properties due to faults in power transformer. In this paper, a new approach based on Depolarisation Current Ratio Index (DRI) was developed for identifying and classifying different transformer fault conditions. The DRI at time interval of 4s to 100s was analysed and the results show that DRI of depolarisation current between 5/100s and 10/100s provides higher correlation on the incipient faults in power transformer.
    Matched MeSH terms: Reproducibility of Results
  12. Hamzah H, Tan CS, Ramlee F, Zulkifli SS
    BMC Psychol, 2023 Nov 13;11(1):392.
    PMID: 37957763 DOI: 10.1186/s40359-023-01435-5
    BACKGROUND: The original Family Resilience Scale (FRS) is a reliable tool to assess family resilience. However, the FRS is based on the United States and parental context. Thus, the usefulness of the FRS for the adolescent and young adult population in Asian countries, particularly Malaysia remains unknown. This study translated the FRS into the Malay language and validated it on Malaysian adolescents and young adults to identify its potential as a self-report tool to assess the resilience level of their family.

    METHODS: A total of 351 participants (Mage = 19.75, SDage = 3.29) were recruited in the study using purposive sampling. Confirmatory factor analysis was conducted to examine the factorial structure of the Family Resilience Scale-Malay (FRS-Malay) and measurement invariance between adolescents and young adults. Then, the scale's reliability was investigated using Cronbach's alpha, McDonald's omega coefficients, and composite reliability index. Finally, we examined the discriminant validity of the FRS-Malay by correlating its score with individual resilience score and examined the incremental validity of the scale using hierarchical multiple regression analysis to test if family resilience can explain individual well-being levels beyond and above individual resilience.

    RESULTS: The findings of the confirmatory factor analysis suggest that a single-factor model is supported for both age groups. Furthermore, the scale exhibited scalar invariance between adolescents and young adults. The scale also exhibited good reliability, as the value of Cronbach's alpha, McDonald omega coefficients, and composite reliability index were above 0.80. Additionally, the Pearson correlation analysis showed a positive correlation between the FRS-Malay and individual resilience scores, which supports the discriminant validity of the scale. Similarly, the incremental validity of the scale is also supported. Specifically, family resilience had a positive correlation with well-being, even after controlling for individual resilience in the regression analysis.

    CONCLUSIONS: The FRS-Malay has demonstrated good reliability and validity. The scale measures the same construct of family resilience across adolescents and young adults, making it suitable for comparisons. Therefore, this unidimensional tool is appropriate for self-reporting their perceived level of family resilience. It is also useful for studying the development and fluctuation of family resilience in the Malaysian context.

    Matched MeSH terms: Reproducibility of Results
  13. Azizul Isha, Nor Azah Yusof, Musa Ahmad, Dedy Suhendra, Wan Md. Zin Wan Yunus, Zulkarnain Zainal
    MyJurnal
    An artificial neural network (ANN) was applied for the determination of V(V) based on immobilized fatty hydroxamic acid (FHA) in poly(methyl methacrylate) (PMMA). Spectra obtained from the V(V)-FHA complex at single wavelengths was used as the input data for the ANN. The V(V)-FHA complex shows a limited linear dynamic range of V(V) concentration of 10 - 100 mg/ L. After training with ANN, the linear dynamic range was extended with low calibration error. A three layer feed forward neural network using backpropagation (BP) algorithm was employed in this study. The input layer consisted of single neurons, 30 neurons in hidden a layer and one output neuron was found appropriate for the multivariate calibration used. The network were trained up to 10000 epochs with 0.003 % learning rate. This reagent also provided a good analytical pedormance with reproducibility characters of the method yielding relative standard deviation (RSD) of 9.29% and 7.09% for V(V) at concentrations of 50 mg/ L and 200 mg/ L, respectively. The limit of detection of the method was 8.4 mg/ L.
    Matched MeSH terms: Reproducibility of Results
  14. Boo NY, Cheong KB, Cheong SK, Lye MS, Zulfiqar MA
    J Paediatr Child Health, 1997 Aug;33(4):329-34.
    PMID: 9323622
    OBJECTIVES: To compare the overall accuracy of the stable microbubble test (SM test) with measurement of level of surfactant protein A (SP-A) of tracheal aspirate for the diagnosis of respiratory distress syndrome (RDS).

    METHODOLOGY: Tracheal aspirates were obtained from neonates on ventilatory support. The SM test was carried out on specimens of tracheal aspirate immediately after collection. Levels of SP-A in tracheal aspirates were determined by enzyme-linked immunosorbent assay (ELISA) method. The results of the SM test and SP-A level of the tracheal aspirates were compared against the clinical diagnosis of RDS based on clinical, radiological and bacteriological findings.

    RESULTS: Both the median microbubble counts (6 microbubbles/mm2, range = 0-90) and median SP-A levels (100 micrograms/L, range = 0-67447) of infants with RDS were significantly lower than those of infants with no obvious lung pathology (P < 0.0001), and pneumonia (P < 0.0001). The SM test of tracheal aspirates had higher overall accuracy for the diagnosis of RDS than measurement of SP-A levels (94.6% vs 82.4%). When the receiver operating characteristic (ROC) curves of both tests for RDS were compared, the area under the ROC curve of the SM test was larger (0.9689) than that of the SP-A method (0.8965).

    CONCLUSIONS: This study showed that the SM test of tracheal aspirate was a useful bedside diagnostic test for RDS. It could be carried out at any time after birth on infants requiring ventilatory support.

    Matched MeSH terms: Reproducibility of Results
  15. Hasni H, Meah FA, Norlia A, Sharifah NA, Zulfiqar A
    Med J Malaysia, 2004 Oct;59(4):486-94.
    PMID: 15779581
    The aim of the study was: to obtain the profile of patients (with regards to age and family history of breast cancer) with a palpable breast mass. To determine the validity of ultrasound in the assessment of the palpable breast mass by determining the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of ultrasound in distinguishing a malignant mass. To determine the most discriminating ultrasound characteristics for differentiating benign and malignant masses. Seventy patients who had fine needle aspiration cytology of a palpable breast mass were subjected to an ultrasound assessment of the mass. The ultrasound findings were classified as benign, indeterminate or malignant. These findings were then compared with either the cytology or histology results in cases that eventually had surgical excision. The age of the patients ranged from 15 to 66 years old The majority was in the third and fourth decades with an average age of 25 years. The 8 patients with a proven malignant breast mass were aged between 39 and 66 years old. They did not have any family history of breast cancer. Only 4 patients had a family history of breast carcinoma and all proved to have a benign breast lesion. Ultrasound had a sensitivity of 100%, specificity of 85.7%, positive predictive value of 50%, negative predictive value of 100% and accuracy of 87.5% for distinguishing a malignant mass. For benign masses: 93.7% had well-defined margins, 81.3% had homogenous internal echoes, 91.7% had depth-width ratio of less than 1.0 and 89% were compressible. For malignant masses: 87.5% had either ill-defined or irregular margins, 87.5% had inhomogenous internal echoes and mixed posterior echoes, and 100% were incompressible. The majority of patients with a palpable breast mass were aged below 40 years old. Most of the patients with a malignant breast mass were aged 40 years and older. Neither a positive nor a negative family history of breast cancer had any significance on outcome. Ultrasound had high sensitivity, specificity and accuracy in distinguishing a malignant mass. The most discriminating benign ultrasound characteristic was compressibility. The most discriminating malignant ultrasound characteristic was ill-defined and irregular margins.
    Matched MeSH terms: Reproducibility of Results
  16. Siddiqui MF, Sakinah M, Singh L, Zularisam AW
    J Biotechnol, 2012 Oct 31;161(3):190-7.
    PMID: 22796090 DOI: 10.1016/j.jbiotec.2012.06.029
    Exploring novel biological anti-quorum sensing (QS) agents to control membrane biofouling is of great worth in order to allow sustainable performance of membrane bioreactors (MBRs) for wastewater treatment. In recent studies, QS inhibitors have provided evidence of alternative route to control membrane biofouling. This study investigated the role of Piper betle extract (PBE) as an anti-QS agent to mitigate membrane biofouling. Results demonstrated the occurrence of the N-acyl-homoserine-lactone (AHL) autoinducers (AIs), correlate QS activity and membrane biofouling mitigation. The AIs production in bioreactor was confirmed using an indicator strain Agrobacterium tumefaciens (NTL4) harboring plasmid pZLR4. Moreover, three different AHLs were found in biocake using thin layer chromatographic analysis. An increase in extracellular polymeric substances (EPS) and transmembrane pressure (TMP) was observed with AHL activity of the biocake during continuous MBR operation, which shows that membrane biofouling was in close relationship with QS activity. PBE was verified to mitigate membrane biofouling via inhibiting AIs production. SEM analysis further confirmed the effect of PBE on EPS and biofilm formation. These results exhibited that PBE could be a novel agent to target AIs for mitigation of membrane biofouling. Further work can be carried out to purify the active compound of Piper betle extract to target the QS to mitigate membrane biofouling.
    Matched MeSH terms: Reproducibility of Results
  17. Basri KN, Yazid F, Megat Abdul Wahab R, Mohd Zain MN, Md Yusof Z, Zoolfakar AS
    PMID: 34634732 DOI: 10.1016/j.saa.2021.120464
    Caries is one of the non-communicable diseases that has a high prevalence trend. The current methods used to detect caries require sophisticated laboratory equipment, professional inspection, and expensive equipment such as X-ray imaging device. A non-invasive and economical method is required to substitute the conventional methods for the detection of caries. UV absorption spectroscopy coupled with chemometrics analysis has emerged as a good potential candidate for such an application. Data preprocessing methods such as mean centre, autoscale and Savitzky-Golay smoothing were implemented to enhance the signal-to-noise ratio of spectra data. Various classification algorithms namely K-nearest neighbours (KNN), logistic regression (LR) and linear discriminant analysis (LDA) were implemented to classify the severity of dental caries into International Caries Detection and Assessment System (ICDAS) scores. The performance of the prediction model was measured and comparatively analysed based on the accuracy, precision, sensitivity, and specificity. The LDA algorithm combined with the Savitzky-Golay preprocessing method had shown the best result with respect to the validation data accuracy, precision, sensitivity and specificity, where each had values of 0.90, 1.00, 0.86 and 1.00 respectively. The area under the curve of the ROC plot computed for the LDA algorithm was 0.95, which indicated that the prediction algorithm was capable of differentiating normal and caries teeth excellently.
    Matched MeSH terms: Reproducibility of Results
  18. Abubakar A, Shaukat SI, Karim NKA, Kassim MZ, Lim SY, Appalanaido GK, et al.
    Phys Eng Sci Med, 2023 Mar;46(1):339-352.
    PMID: 36847965 DOI: 10.1007/s13246-023-01227-6
    Deep inspiration breath-hold radiotherapy (DIBH-RT) reduces cardiac dose by over 50%. However, poor breath-hold reproducibility could result in target miss which compromises the treatment success. This study aimed to benchmark the accuracy of a Time-of-Flight (ToF) imaging system for monitoring breath-hold during DIBH-RT. The accuracy of an Argos P330 3D ToF camera (Bluetechnix, Austria) was evaluated for patient setup verification and intra-fraction monitoring among 13 DIBH-RT left breast cancer patients. The ToF imaging was performed simultaneously with in-room cone beam computed tomography (CBCT) and electronic portal imaging device (EPID) imaging systems during patient setup and treatment delivery, respectively. Patient surface depths (PSD) during setup were extracted from the ToF and the CBCT images during free breathing and DIBH using MATLAB (MathWorks, Natick, MA) and the chest surface displacement were compared. The mean difference ± standard deviation, correlation coefficient, and limit of agreement between the CBCT and ToF were 2.88 ± 5.89 mm, 0.92, and - 7.36, 1.60 mm, respectively. The breath-hold stability and reproducibility were estimated using the central lung depth extracted from the EPID images during treatment and compared with the PSD from the ToF. The average correlation between ToF and EPID was - 0.84. The average intra-field reproducibility for all the fields was within 2.70 mm. The average intra-fraction reproducibility and stability were 3.74 mm, and 0.80 mm, respectively. The study demonstrated the feasibility of using ToF camera for monitoring breath-hold during DIBH-RT and shows good breath-hold reproducibility and stability during the treatment delivery.
    Matched MeSH terms: Reproducibility of Results
  19. Blebil AQ, Sulaiman SA, Hassali MA, Dujaili JA, Zin AM
    J Epidemiol Glob Health, 2015 Mar;5(1):15-22.
    PMID: 25700919 DOI: 10.1016/j.jegh.2014.10.006
    This study aimed to evaluate the psychometric properties of Malay translated version of the brief questionnaire of smoking urges (QSU-Brief). The translation procedure was done following the standard guidelines. The reliability and validity of the Malaysian version scale were evaluated based on the data collected from 133 Malaysian smokers. The internal consistency was calculated to assess the reliability. Factor analysis and construct validity were performed to validate psychometric properties of the scale. Total Cronbach's alpha of the scale was 0.806. The exploratory factor analysis revealed two factors that accounted for 66.15% of the explained total variance. The first component consisted of items 1, 3, 6, 7, and 10, while the second component included the rest. The QSU-Brief total score had a significant positive relationship with exhaled CO level (r=0.24; P=0.005), number of cigarettes smoked per day (r=0.30; P<0.001) and other clinical factors. Items 2 and 5 loaded strongly on factor 2, whereas both items loaded ambivalently on two factors in the previous studies. This discrepancy might be clarified by language differences. The Malaysian QSU-Brief is a good candidate for evaluating urge to smoke in both clinical practice and clinical trials.
    Matched MeSH terms: Reproducibility of Results
  20. Blebil AQ, S Sulaiman SA, A Hassali M, Dujaili JA, Zin AM
    Value Health Reg Issues, 2014 May;3:19-23.
    PMID: 29702926 DOI: 10.1016/j.vhri.2013.09.001
    OBJECTIVES: Assessment of nicotine withdrawal symptoms is an essential part of tobacco dependence treatment. This study aimed to evaluate the psychometric properties of a Malay translated version of the Minnesota Nicotine Withdrawal Scale (MNWS).

    METHODS: The original scale was translated into Malay following the standard guidelines proposed for translation studies. The reliability and validity of the Malay version scale were evaluated on the basis of data collected from 133 participants. The Cronbach's alpha coefficient was calculated to assess the reliability. To validate the psychometric properties of the scale, factor analysis and construct validity were used. This study was conducted at the Quit Smoking Clinic at Penang General Hospital, Penang, Malaysia.

    RESULTS: The translated scale has excellent reliability, with total Cronbach's alpha of 0.91. The test-retest reliability for the scale presented an excellent reliability and stability of the translated scale with Spearman's rank correlation coefficient (r = 0.876; P < 0.001). There was a significant positive correlation between the exhaled carbon monoxide level, Fagerstrom Test for Nicotine Dependence total score, and number of cigarettes smoked per day and the MNWS total score (r = 0.72, 0.68, and 0.68, respectively; P < 0.001). A principal-components analysis with orthogonal rotation yielded a unidimensional model that includes all the items of the MNWS.

    CONCLUSIONS: The Malay version of the MNWS is a reliable and valid measure of withdrawal symptoms as well as the smoking urge, and it is applicable to clinical practice and research study.

    Study site: Quit Smoking Clinic at Penang General Hospital, Penang, Malaysia.
    Matched MeSH terms: Reproducibility of Results
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links