Displaying publications 1 - 20 of 1041 in total

Abstract:
Sort:
  1. Ng SF, Rouse JJ, Sanderson FD, Meidan V, Eccleston GM
    AAPS PharmSciTech, 2010 Sep;11(3):1432-41.
    PMID: 20842539 DOI: 10.1208/s12249-010-9522-9
    Over the years, in vitro Franz diffusion experiments have evolved into one of the most important methods for researching transdermal drug administration. Unfortunately, this type of testing often yields permeation data that suffer from poor reproducibility. Moreover, this feature frequently occurs when synthetic membranes are used as barriers, in which case biological tissue-associated variability has been removed as an artefact of total variation. The objective of the current study was to evaluate the influence of a full-validation protocol on the performance of a tailor-made array of Franz diffusion cells (GlaxoSmithKline, Harlow, UK) available in our laboratory. To this end, ibuprofen was used as a model hydrophobic drug while synthetic membranes were used as barriers. The parameters investigated included Franz cell dimensions, stirring conditions, membrane type, membrane treatment, temperature regulation and sampling frequency. It was determined that validation dramatically reduced derived data variability as the coefficient of variation for steady-state ibuprofen permeation from a gel formulation was reduced from 25.7% to 5.3% (n = 6). Thus, validation and refinement of the protocol combined with improved operator training can greatly enhance reproducibility in Franz cell experimentation.
    Matched MeSH terms: Sensitivity and Specificity
  2. AIDS Patient Care STDS, 2000 Apr;14(4):225-6.
    PMID: 10806645
    Matched MeSH terms: Sensitivity and Specificity
  3. Yuslina MY, Shahnaz M, Too CL, Hussein H, Wahinuddin S, Eashwary M, et al.
    APLAR Journal of Rheumatology, 2006;9 Suppl 1:A187-A188.
    Background: Anti-cyclic citrullinated peptide autoantibodies (anti-CCP) is a new serological test for the diagnosis of rheumatoid arthritis (RA). It is an enzyme immunoassay (EIA) for the detection of antibodies directed toward citrullinated peptides. Studies show this test has an improved diagnostic value compared to rheumatoid factor (RF). Objective: To determine the sensitivity and specificity of anti-CCP in patients with rheumatoid arthritis and other rheumatic diseases. Method: 227 serum samples for rheumatology clinics (Putrajaya, Taiping, and Ipoh Hospital) were tested for the presence of anti-CCP and rheumatoid factor (RF). These included 171 patients diagnosed with RA and 56 from other rheumatic diseases. Patient demographic data, clinical diagnosis, radiographic information and other laboratory data were obtained from the patients' clinical notes. Results: Anti-CCP antibodies were detected in 76.6% (131/171) patients with RA and 17.9% (10/56) patients with other arthritis. The sensitivity and specificity of anti-CCP reactivity at the optimal cut off values were 66.1% and 87.5% respectively. The sensitivity of anti-CCP was higher than that for RF (41.8%). However, the presence of either anti-CCP or RF improved the sensitivity to 76.2%. Conclusion: The detection of anti-CCP alone maybe useful in the diagnosis of RA. However, when used concomitantly with RF, it can improve the diagnostic ability significantly.
    Matched MeSH terms: Sensitivity and Specificity
  4. Ahmad Fuad Abdul Rahim, Mohd Jamil Yaacob, Muhamad Saiful Bahri Yusoff
    ASEAN Journal of Psychiatry, 2010;11(1):36-43.
    MyJurnal
    Objective: To determine the sensitivity, specificity and internal consistency of the Malay version GHQ-12 among medical student population. This study determined the appropriate GHQ-12 score to detect distressed medical students. Methods: The Malay version of GHQ-12 was derived based on two sources which were the original version GHQ-12 and the validated Malay version 30-items GHQ. The GHQ-12 and the Malay version Beck Depression Inventory-II (BDI-II) were administered to a total of 141 medical students. Distress diagnoses were made based on the Malay version BDI-II. ROC curve analysis was applied to determine the sensitivity and specificity of the GHQ-12 by testing against the BDI-II. Reliability analysis (Cronbach’s alpha and item total correlation) was applied to test internal consistency of the
    GHQ-12. The analysis was done using SPSS version 12.Results: The GHQ-12 sensitivity and specificity at cut-off point of 3/4 was 81.3% and 75.3% respectively with positive predictive value (PPV) of 62.9% as well as area under ROC curve more than 0.7. The Cronbach’s alpha value of the GHQ-12 was 0.85.Conclusion: This study showed the Malay version GHQ-12 is a valid and reliable screening tool in detecting distressed medical students. The
    GHQ-12 score equal to or more than 4 was considered as significant distress.
    Matched MeSH terms: Sensitivity and Specificity
  5. Mukhtar F, Abu Bakar AK, Mat Junus M, Awaludin A, Abdul Aziz S, Midin M, et al.
    ASEAN Journal of Psychiatry, 2012;13(2):157-164.
    MyJurnal
    Objective: The MINI International Neuropsychiatric Interview (MINI) is a short, structured diagnostic interview compatible with the Diagnostic and Statistical Manual of Mental Disorders-IV (DSM-IV). It was designed for clinical practice, research in psychiatric, primary care settings and epidemiological surveys. This preliminary study aims to evaluate the reliability and validity of the Malaysian Version of MINI for Major Depressive Disorder and Generalized Anxiety Disorder symptoms criteria only.

    Methods: Six hours of MINI training was given as part of a National Health Morbidity Survey training program for layman interviewers (n=229) and three videos were prepared by an expert psychiatrist for inter-rater reliability purposes. Meanwhile, for validity purposes, the MINI was administered to patients with Major Depressive Disorder (n=30), Generalized Anxiety Disorder (n=20) and to a normal population (n=60), to conform against the Diagnostic and Statistical Manual of Mental Disorder (DSM-IV) that was administered by psychiatrists.

    Results: Overall the inter-rater reliability was satisfactory (0.67 to 0.85) and the concordance between the MINI’s and expert diagnoses was good, with kappa values of greater than 0.88.

    Conclusions: The Malay version of the MINI is adjusted to the clinical setting and for the assessment of positive cases in a community setting. Modifications were highlighted to correct any identified problems and to improve the reliability of the MINI for future research and clinical use.
    Matched MeSH terms: Sensitivity and Specificity
  6. Siti Raudzah Ghazali, Elklit, Ask, Rekaya Vincent Balang, Ameenudeen Sultan, M., Yoke, Yong Chen
    ASEAN Journal of Psychiatry, 2014;15(2):146-152.
    MyJurnal
    Objective: The objective of this study is to determine the optimal cut-off score for the Centre for Epidemiologic Studies Depression scale (CESD) according to Malaysian adolescent norms. Methods: This is a cross-sectional study. Nine hundred and thirty-one adolescents aged 13 to 17 years-old completed the CESD and Hopkins Symptom Checklist-depression scale (HSCL-depression). Results: Results from the receiver operating characteristic (ROC) curve, kappa coefficients and odds ratio analysis showed that CESD cut-off score of 27 was suitable to be used according to Malaysian norms, demonstrating a specificity of 93%. Conclusion: The findings suggest a cut-off score 27 should be used for screening of depression for Malaysian adolescents using the CESD. ASEAN Journal of Psychiatry, Vol. 15 (2): July - December 2014: 146-152.
    Matched MeSH terms: Sensitivity and Specificity
  7. Hani AF, Kumar D, Malik AS, Walter N, Razak R, Kiflie A
    Acad Radiol, 2015 Jan;22(1):93-104.
    PMID: 25481518 DOI: 10.1016/j.acra.2014.08.008
    Quantitative assessment of knee articular cartilage (AC) morphology using magnetic resonance (MR) imaging requires an accurate segmentation and 3D reconstruction. However, automatic AC segmentation and 3D reconstruction from hydrogen-based MR images alone is challenging because of inhomogeneous intensities, shape irregularity, and low contrast existing in the cartilage region. Thus, the objective of this research was to provide an insight into morphologic assessment of AC using multilevel data processing of multinuclear ((23)Na and (1)H) MR knee images.
    Matched MeSH terms: Sensitivity and Specificity
  8. Wong SC, Nawawi O, Ramli N, Abd Kadir KA
    Acad Radiol, 2012 Jun;19(6):701-7.
    PMID: 22578227 DOI: 10.1016/j.acra.2012.02.012
    The aim of this study was to compare conventional two-dimensional (2D) digital subtraction angiography (DSA) with three-dimensional (3D) rotational DSA in the investigation of intracranial aneurysm in terms of detection, size measurement, neck diameter, neck delineation, and relationship with surrounding vessels. A further aim was to compare radiation dose, contrast volume, and procedural time between the two protocols.
    Matched MeSH terms: Sensitivity and Specificity
  9. Ngim CA, Abdul Rahman AR, Ibrahim A
    Acta Cardiol, 1999 Oct;54(5):277-82.
    PMID: 10596307
    BACKGROUND: Arterial stiffness, an aging process which is accelerated by hypertension, is emerging as a useful index of vascular health. There are evidences to suggest that hyperinsulinaemia may be an independent risk factor for coronary artery disease, besides its possible pathogenic role in essential hypertension. The main objectives of this study were to compare arterial stiffness between untreated hypertensives and normotensives and to investigate the relationship between fasting serum insulin and arterial stiffness.

    METHODS: A cross-sectional observational study was designed. Forty normotensive (median age 47 +/- 6 yrs.) and twenty untreated hypertensive Malay men (median age 50 +/- 7 yrs.) without clinical evidence of cardiovascular complications were selected. Pulse wave velocity measured using the automated Complior machine was used as an index of arterial stiffness. Other measurements obtained were blood pressure, body mass index, fasting insulin, cholesterol, HDL-cholesterol, LDL-cholesterol, triglycerides, glucose and creatinine level.

    RESULTS: The blood pressure and pulse wave velocity (PWV) were significantly higher in the hypertensives compared to the normotensives (blood pressure 169/100 mm Hg +/- 14/7 vs. 120/80 mm Hg +/- 10/4, p < 0.001; PWV 11.69 m/s +/- 1.12 vs. 8.83 m/s +/- 1.35, p < 0.001). Other variables such as body mass index, fasting insulin, cholesterol, HDL-cholesterol, LDL-cholesterol, triglycerides and haematocrit were comparable among the two groups. Within each group, there was a significant positive correlation between pulse wave velocity and systolic blood pressure (r = 0.76, p < 0.001 in normotensives; r = 0.73, p < 0.001 in hypertensives) and mean arterial pressure (r = 0.74, p < 0.001 in normotensives; r = 0.73, p < 0.001 in hypertensives). No correlation was noted between pulse wave velocity and diastolic blood pressure, age, body mass index, fasting insulin level, cholesterol, HDL-cholesterol, LDL-cholesterol or triglyceride levels.

    CONCLUSION: Arterial stiffness as determined by PWV is increased in newly diagnosed untreated hypertensive subjects even before clinically evident cardiovascular disease. However, arterial stiffness is not correlated with the fasting insulin level in normotensives and newly diagnosed hypertensives.

    Matched MeSH terms: Sensitivity and Specificity
  10. Jayaram G, Elsayed EM, Yaccob RB
    Acta Cytol., 2007 Jan-Feb;51(1):3-8.
    PMID: 17328487
    OBJECTIVE: To analyze the cytologic features of nipple discharge and fine needle aspiration (FNA) cytologic smears from breast lesions reported as showing papillary features and to correlate them with histopathologic features.

    STUDY DESIGN: The study group consisted of FNA smears and/or nipple discharge smears from 65 breast lesions diagnosed on cytology as duct papilloma, papillary lesion, fibrocystic condition, fibroadenoma, papillary neoplasm or papillary carcinoma. Cytomorphologic features assessed included cellularity, cell pattern (clusters, papillary, 3-dimensionality, etc.) and cell characteristics (monomorphism, pleomorphism, apocrine change, plasmacytoid features). Histological material was available for review and cytohistologic correlation in all cases.

    RESULTS: Forty-six specimens were FNA smears, and 16 were nipple discharge smears; in 3 cases FNA and nipple discharge cytologic smears were available for review. Cytologic study could predict the presence of a papillary pattern in all neoplasms with pure or focal papillary differentiation. There was an overlap in cytomorphologic features between papillary and nonpapillary benign lesions as well as between benign and malignant papillary neoplasms. Frank blood in the aspirate, cell dissociation and atypia, however, were more frequent in the last.

    CONCLUSION: Overlap of cytologic features in nonneoplastic and neoplastic benign papillary lesions and between benign and malignant papillary neoplasms necessitates histologic evaluation in all cases diagnosed as papillary on cytology. Since 49.2% of lesions showing papillary features on cytology prove to be malignant, all cases reported as papillary on cytology should be excised urgently for histologic assessment.
    Matched MeSH terms: Sensitivity and Specificity
  11. Jayaram G, Elsayed EM
    Acta Cytol., 2005 Nov-Dec;49(6):605-10.
    PMID: 16450899
    To type breast carcinomaon on fine needle aspiration cytology (FNAC) material and correlate the results with histologic typing, to grade breast carcinoma on FNAC material and correlate the findings with Bloom-Richardson histologic grading, and to determine the estrogen receptor (ER) status in cases of breast carcinoma by immunocytochemical (ICC) staining of FNA cytologic material and correlate the findings with ER status, as determined by immunohistochemical (IHC) staining of tissue sections.

    STUDY DESIGN: Seventy-seven cases of breast carcinoma diagnosed on FNAC formed the basis of this study. Typing was done in all cases on the basis of cytologic features and grading in 62. (Fifteen cases were special types of breast carcinoma). In all cases, ER status was determined by immunostaining of cytologic smears. Results of tumor typing, grading and ER status on cytologic material were compared with the results of histologic typing, grading and immunostaining of histologic material obtained from mastectomy or wide excision specimens.

    RESULTS: Tumor typing was accurate in 73 of 77 cases (94.8%). Fifteen of 18 cases that were cytologically grade 3 were confirmed on histology, while 3 proved to be grade 2. Of 40 cytologic grade 2 cases, 26 were confirmed on histology, while 14 cases were grade 3. Three of 4 cytologically grade 1 cases were confirmed on histology while 1 was grade 2. The overall accuracy for cytologic grading was 71% (44 of 62 cases). Thirty-seven of 40 ER-positive cases (92.5%) were labeled ER positive on ICC. One case was ER negative on cytology, while in 2 cases the cellularity of the cytologic smear was insufficient to assess ER expression. Thirty-seven cases were negativefor ER on IHC. Nine of these showed ER positivity on ICC, 26 were negative, and 2 had cellularity that was inadequate for assessment of ER. Sensitivity and specificity rates for ER detection on ICC were 97.4% and 74.3%, respectively.

    CONCLUSION: Tumor typing, grading and evaluation of ER status on FNA C material in breast carcinomas are simple, quick and moderately reliable techniques that compare and correlate favorably with histologic typing, grading and ER status on IHC.
    Matched MeSH terms: Sensitivity and Specificity
  12. Jayaram G, Jayalakshmi P, Yip CH
    Acta Cytol., 2005 Nov-Dec;49(6):656-60.
    PMID: 16450908
    BACKGROUND: Leiomyosarcoma of the breast is a rare neoplasm. We present a case of primary leiomyosarcoma of the breast in a middle-aged female in whom fine needle aspiration cytologic features suggested sarcoma.

    CASE: A 55-year-old female presented with a rapidly growing breast lump of 1 month's duration. On examination, an ulcerating, 12 x 10 cm tumor was seen involving the lower medial and lateral quadrants of the right breast. Fine needle aspiration cytology showed variably sized, dissociated and loosely clustered polygonal, plump and spindle cells with pale blue cytoplasm and vesicular nuclei that were round, oval or irregular. Occasional giant forms and nucleolated and mitotic cells were present. A single cluster of benign ductal cells was seen. The tumor cells did not express immunocytologic reactivity to estrogen receptor protein. A cytologic diagnosis of sarcoma was given with differential diagnoses of metaplastic carcinoma and malignant phyllodes tumor. Histologic study established the diagnosis of leiomyosarcoma. Leiomyosarcoma of the breast shows fine needle aspiration cytologic features of sarcoma, but specific tumor typing may not be possible, especially when the cytologic material is inadequate for ancillary staining required to distinguish leiomyosarcoma from metaplastic carcinoma and malignant phyllodes tumor.
    Matched MeSH terms: Sensitivity and Specificity
  13. Abdullah J, Zamzuri I, Awang S, Sayuthi S, Ghani A, Tahir A, et al.
    Acta Neurochir. Suppl., 2005;95:311-4.
    PMID: 16463872
    The monitoring of craniospinal compliance is uncommonly used clinically despite it's value. The Spiegelberg compliance monitor calculates intracranial compliance (C = deltaV/deltaP) from a moving average of small ICP perturbations (deltaP) resulting from a sequence of up to 200 pulses of added volume (deltaV = 0.1 ml, total V = 0.2 ml) made into a double lumen intraventricular balloon catheter. The objective of this study was thus to determine the effectiveness of the decompressive craniectomy done on the worst brain site with regard to compliance (Cl), pressure volume index (PVI), jugular oximetry (SjVo2), autoregulation abnormalties, brain tissue oxygen (TiO2) and cerebral blood flow (CBF). This is a prospective cohort study of 17 patients who were enrolled after consent and approval of the ethics committee between the beginning of the year 2001 and end of the year 2002. For pre and post assessment on compliance and PVI, all 12 patients who survived were reported to become normal after decompressive craniectomy. There is no significant association between pre and post craniectomy assessment in jugular oxymetry (p > 0.05), autoregulation (p > 0.05), intracranial brain oxymetry (p = 0.125) and cerebral blood flow (p = 0.375). Compliance and PVI improved dramatically in all alive patients who received decompressive craniectomy. Compliance and PVI monitoring may be crucial in improving the outcome of severe head injured patients after decompressive craniectomy.
    Matched MeSH terms: Sensitivity and Specificity
  14. Noordin R, Smith HV, Mohamad S, Maizels RM, Fong MY
    Acta Trop, 2005 Jan;93(1):57-62.
    PMID: 15589798
    Diagnosis of human toxocariasis, caused by Toxocara canis or Toxocara cati, normally relies on a combination of the presence of clinical signs and symptoms backed by positive serology. The use of Toxocara excretory-secretory antigen (TES) in ELISA assays increases the test specificity. However, in tropical countries where soil-transmitted helminths are endemic, cross-reactivity from antibodies to these intestinal parasites poses a significant limitation for Toxocara serodiagnosis. To increase the specificity of serodiagnosis, we compared the use of IgG-ELISA to the use of IgG4-ELISA using commercially manufactured TES-coated plates. The sensitivity of the IgG-ELISA was 97.1%, while that of the IgG4-ELISA was 45.7%; the specificities were 36.0 and 78.6%, respectively. The study shows that employing both assays can improve the serodiagnosis of toxocariasis. An IgG4 immunoassay would also be useful in the secondary screening of antigen clones in the effort to develop improved serological tests for toxocariasis.
    Matched MeSH terms: Sensitivity and Specificity
  15. Lim PK, Yamasaki H, Mak JW, Wong SF, Chong CW, Yap IK, et al.
    Acta Trop, 2015 Aug;148:32-7.
    PMID: 25910623 DOI: 10.1016/j.actatropica.2015.04.011
    Human toxocariasis which is caused mainly by the larvae of Toxocara canis and Toxocara cati, is a worldwide zoonotic disease that can be a potentially serious human infection. The enzyme-linked immunosorbent assay (ELISA) using T. canis excretory-secretory (TES) antigens harvested from T. canis larvae is currently the serological test for confirming toxocariasis. An alternative to producing large amounts of Toxocara TES and improved diagnosis for toxocariasis is through the development of highly specific recombinant antigens such as the T. canis second stage larva excretory-secretory 30 kDa protein (recTES-30). The aim of this study was to evaluate the sensitivity and specificity of a rapid diagnostic kit (RDT, named as iToxocara kit) in comparison to recTES-30 ELISA in Serendah Orang Asli village in Selangor, Malaysia. A total of 133 subjects were included in the study. The overall prevalence rates by ELISA and RDT were 29.3% and 33.1%, respectively, with more positive cases detected in males than females. However, no association was found between toxocariasis and gender or age. The percentage sensitivity, specificity, positive predictive value and negative predictive value of RDT were 85.7%, 90.1%, 80% and 93.2%, respectively. The prevalence for toxocariasis in this population using both ELISA and RDT was 27.1% (36/133) and the K-concordance test suggested good agreement of the two tests with a Cohen's kappa of 0.722, P<0.01. In addition, the followed-up Spearman rank correlation showed a moderately high correlation at R=0.704 and P<0.01. In conclusion, the RDT kit was faster and easier to use than an ELISA and is useful for the laboratory diagnosis of hospitalized cases of toxocariasis.
    Matched MeSH terms: Sensitivity and Specificity
  16. Choo KE, Davis TM, Ismail A, Tuan Ibrahim TA, Ghazali WN
    Acta Trop, 1999 Mar 15;72(2):175-83.
    PMID: 10206117
    The Typhidot test, which detects IgM and IgG antibodies to a Salmonella typhi-specific outer membrane protein, is as sensitive as, and more specific than, the Widal test in the diagnosis of enteric fever in Malaysian children. It is easier and quicker to perform. In order to increase diagnostic accuracy in an area of high endemicity, the Typhidot-M test has been developed in which IgG is first removed. This theoretically allows improved detection of IgM, and thus would differentiate new from recent infections. We evaluated both tests in 134 unselected febrile children admitted to the General Hospital Kota Bharu, Malaysia. The children were divided into two groups: (i) those who were blood and/or stool culture positive for S. typhi and/or who had clinical features strongly suggestive of enteric fever (n = 62); and (ii) those who were both culture-negative and had clinical evidence of another diagnosis (n = 72). The sensitivity and specificity of the Typhidot and Typhidot-M tests were identical at 90.3 and 93.1%, respectively. Both tests had comparable sensitivity but greater specificity than those of the Widal test (91.9 and 80.6%, respectively). When used together, a positive result for Typhidot and/or Typhidot-M was more specific than either test alone (95.2%) but specificity was lower (87.5%). We conclude that the Typhidot and Typhidot-M tests have comparatively high diagnostic accuracy, suggesting that IgM can be detected in children who may have a predominant IgG response to S. typhi. Using these tests in combination increases the negative predictive value but at the cost of a lower positive predictive value.
    Matched MeSH terms: Sensitivity and Specificity
  17. Balachandra D, Rahumatullah A, Lim TS, Mustafa FH, Ahmad H, Anuar NS, et al.
    Acta Trop, 2021 Sep;221:105986.
    PMID: 34058161 DOI: 10.1016/j.actatropica.2021.105986
    Serodiagnosis is an essential component of the laboratory diagnosis of Strongyloides infection and is usually performed using an indirect IgG antibody test. A direct antigen detection method can complement the IgG assay, particularly for detecting early infection and post-treatment follow-up. In the present study, a recombinant scFv monoclonal antibody against NIE recombinant protein (rMAb23) that we had previously produced was used to develop a Strongyloides antigen detection ELISA (SsAg-ELISA). The assay is based on detecting immune complexes of circulating NIE antigens bound to Strongyloides-specific IgG antibodies. The optimized ELISA parameters were 10 µg/mL of rMAb23 coated on microtitre plate wells, 2% skim milk as blocking reagent, 1:100 serum dilution, and 1:1000 goat anti-human IgG F(ab')2 conjugated to horseradish peroxidase. Four groups of serum samples were used, i.e., Strongyloides-positive serum samples categorized into Groups IA and IB; the former were from probable chronic infections and the latter from probable early/acute infections. Strongyloides-negative samples comprising Groups II (healthy samples) and III (other infections); the latter were from eleven different types of other parasitic infections. The receiver operating characteristic (ROC) curve showed an area under the curve (AUC) of 1.00, cut-off optical density (OD405) of 0.5002, and 100% diagnostic sensitivity and specificity. The results of the commercial IgG-ELISA and SsAg-ELISA from Group IA were found to be moderately correlated (r = 0.416; p 
    Matched MeSH terms: Sensitivity and Specificity
  18. Wong WK, Foo PC, Olivos-Garcia A, Noordin R, Mohamed Z, Othman N, et al.
    Acta Trop, 2017 Aug;172:208-212.
    PMID: 28506795 DOI: 10.1016/j.actatropica.2017.05.017
    Crude soluble antigen (CSA) produced from Entamoeba histolytica trophozoite is conventionally used for serodiagnosis of invasive amoebiasis. However, high background seropositivities by CSA-assay in endemic areas complicate the interpretation of positive result in clinical settings. Instead, incorporating a second assay which indicates active or recent infection into the routine amoebic serology could possibly complement the limitations of CSA-assay. Hence, the present study aimed to evaluate the diagnostic efficacies of indirect ELISAs using CSA and excretory-secretory antigen (ESA) for serodiagnosis of amoebic liver abscess (ALA). Reference standard for diagnosis of ALA at Hospital Universiti Sains Malaysia is based on clinical presentation, radiological imaging and positive indirect haemagglutination assay (titer ≥256). Five groups of human serum samples collected from the hospital included Group I - ALA diagnosed by the reference standard and pus aspirate analysis using real-time PCR (n=10), Group II - ALA diagnosed by the reference standard only (n=41), Group III - healthy control (n=45), Group IV - other diseases control (n=51) and Group V - other infectious diseases control (n=31). For serodiagnosis of ALA serum samples (Group I and II), CSA-ELISA showed sensitivities of 100% for both groups, while ESA-ELISA showed sensitivities of 100% and 88%, respectively. For serodiagnosis of non-ALA serum samples (Group III, IV and V), CSA-ELISA showed specificities of 91%, 75% and 100%, respectively; while ESA-ELISA showed specificities of 96%, 98% and 100%, respectively. Indirect ELISAs using CSA and ESA have shown distinct strength for serodiagnosis of ALA, in terms of sensitivity and specificity, respectively. In conclusion, parallel analysis by both assays improved the overall efficacies of amoebic serology as compared to either single assay.
    Matched MeSH terms: Sensitivity and Specificity
  19. Khanbabaie S, Riazi M, Chang CH, Yunus MH, Noordin R
    Acta Trop, 2019 Feb;190:171-176.
    PMID: 30458123 DOI: 10.1016/j.actatropica.2018.11.018
    Cystic echinococcosis (CE) is a neglected zoonotic disease with a worldwide distribution and is a major public health problem in some areas. Diagnosis of CE is mainly based on clinical symptoms, imaging and serological testing, however, improvement in serodiagnosis is still needed. This study was aimed at detecting circulating Echinococcus antigen in CE patients using a lateral flow dipstick (LFD) assay. Three types of hydatid antigens i.e. hydatid cyst fluid (HCF), native antigen B (nAgB) and recombinant antigen B (rAgB) were prepared and polyclonal rabbit antiserum was raised against each antigen. Purified IgG fractions were prepared and a portion was conjugated to gold nanoparticles. After a series of optimizations, a final antigen detection LFD assay was developed using a combination of anti-nAgB-IgG and gold-conjugated anti-HCF-IgG. Evaluation of the assay showed that 27 out of 35 (77%) serum samples from CE patients gave positive results. Meanwhile, the test showed a diagnostic specificity of 82% when tested with sera from 38 healthy individuals and 13 patients with other parasitic diseases. In conclusion, the antigen detection LFD assay seemed to be useful for diagnosis of CE and possibly for post-treatment follow-up, and merit further evaluation studies. We foresee that it may improve serodiagnosis of CE when used in tandem with an antibody detection test.
    Matched MeSH terms: Sensitivity and Specificity
  20. Noordin R, Osman E, Kalantari N, Anuar NS, Gorgani-Firouzjaee T, Sithithaworn P, et al.
    Acta Trop, 2022 Feb;226:106251.
    PMID: 34808116 DOI: 10.1016/j.actatropica.2021.106251
    Strongyloides stercoralis is a parasite that causes strongyloidiasis worldwide. It may lead to a life-long infection in immunocompetent people and hyperinfection in immunosuppressed patients. A point-of-care (POC) rapid test is helpful for patient diagnosis in resource-limited settings and as a detection tool in elimination/control programs. Previously, we reported a rapid IgG4 dipstick test (Ss Rapid®) for Strongyloides suitable for a laboratory setting. A POC cassette format of the test, which is field-applicable, has since been developed. Here, we report on a laboratory-based evaluation of the Ss Rapid® cas sette test on 285 sera. We assessed the diagnostic sensitivity of the Ss Rapid® cas sette with 32 sera, comprising samples from larval and/or DNA positive individuals from three countries. Additionally, we also tested samples from 33 seropositive endemic areas residents. We evaluated the diagnostic specificity of the test using 220 samples, comprising sera from other infections (n = 101), allergy cases with high IgE antibodies (n = 4), and blood donors (n = 115). The test showed high diagnostic sensitivity (97%, 31/32), and all sera of the seropositive endemic residents were reactive. It also showed high diagnostic specificity (94.5%, 208/220), and all false-positive samples tested negative after sera adsorption using recombinant NIE-coated microsphere beads. Additionally, we showed that the test worked with spiked whole blood samples. The study results showed that the SsRapid® cas sette test merits further laboratory and field evaluations.
    Matched MeSH terms: Sensitivity and Specificity
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links