METHODS: 3317 raw digital mammograms were processed with Volpara(®) (Matakina Technology Ltd, Wellington, New Zealand) to obtain fibroglandular tissue volume (FGV), breast volume (BV) and VBD. Errors in parameters including CBT, kVp, filter thickness and mAs were simulated by varying them in the Digital Imaging and Communications in Medicine (DICOM) tags of the images up to ±10% of the original values. Errors in detector gain and offset were simulated by varying them in the Volpara configuration file up to ±10% from their default values. For image noise, Gaussian noise was generated and introduced into the original images.
RESULTS: Errors in filter thickness, mAs, detector gain and offset had limited effects on FGV, BV and VBD. Significant effects in VBD were observed when CBT, kVp, detector offset and image noise were varied (p
STUDY DESIGN: A review of articles was performed.
METHODS: A search strategy was used by using electronic bibliographic databases including PubMed, Embase and CENTRAL for published studies and reference list of published studies. The articles were exported to a bibliographic database for further screening process. Two reviewers worked independently to screen results and extract data from the included studies. Any discrepancies were resolved and confirmed by the consensus of all authors.
RESULTS: There were three screening approaches for detecting MCI and dementia - screening by a healthcare provider, screening by a self-administered questionnaire and caretaker informant screening. Montreal Cognitive Assessment (MoCA) was the most common and preferable tool for MCI screening (sensitivity [Sn]: 81-97%; specificity [Sp]: 60-86%), whereas Addenbrooke's Cognitive Examination (ACE) was the preferable tool for dementia screening (Sn: 79-100%; Sp: 86%).
CONCLUSION: This systematic review found that there are three screening approaches for detecting early dementia and MCI at primary health care. ACE and MoCA are recommended tools for screening of dementia and MCI, respectively.
METHODS: A cross-sectional study was conducted between January and December 2012. A total of 350 adult patients in a teaching hospital were screened for risk of malnutrition using 3-MinNS and Subjective Global Assessment (SGA). To assess interrater reliability, each patient was screened for risk of malnutrition using 3-MinNS by 2 different nurses on 2 different occasions within 24 hours after admission. To assess the validity of 3-MinNS, the level of risk of malnutrition identified by the nurses using 3-MinNS was compared with the risk of malnutrition as assessed by a dietitian using SGA within 48 hours after the patients' enrolment into the study. The sensitivity, specificity, and predictive values were calculated in detecting patients at risk of malnutrition. Interrater reliability was determined using κ statistics.
RESULTS: Using SGA, the estimated prevalence of moderate to severe malnutrition was 36.3% (127/350). There was 94% proportional agreement between 2 nurses using 3-MinNS, and interrater reliability was substantial (κ = 0.79, P < .001). The analysis showed that 3-MinNS had moderate sensitivity (61.4%-68.5%) but high specificity (95.1%).
CONCLUSIONS: The 3-MinNS is a reliable and valid screening tool for use by healthcare professionals for identifying newly admitted medical and surgical patients who are at risk of malnutrition.
Methods: This study was conducted in HUSM's ED over two study periods. In the first three months, 300 patients were triaged under the three-tier triaging system, and, in the subsequent three months, 280 patients were triaged under the ESI. The patients were triaged by junior paramedics and the triage records were retained and later re-triaged by senior paramedics. The inter-rater reliability was evaluated using Cohen's Kappa statistics. The acuity ratings of the junior paramedics were compared with those of the expert panel to determine the sensitivity and specificity of each acuity level for both the ESI and the three-tier triaging system. The over-triage rate, under-triage rate, amount of resources used, admission rate and discharge rate were also determined.
Results: The inter-rater agreement for the three-tier triaging system was 0.81 while that of the ESI was 0.75. The ESI had a higher average sensitivity of 74.3% and a specificity of 94.4% while the three-tier system's average sensitivity was 68.5% and its specificity 87.0%. The average under-triage and over-triage rates for the ESI were 10.7% and 6.2%, respectively, which were lower than the three-tier system's average under-triage rate of 13.1% and over-triage rate of 17.1%. The urgency levels of both the ESI and the three-tier system were associated with increased admission rates and resources used in the ED.
Conclusion: The ESI's inter-rater reliability was comparable to the three-tier triaging system and it demonstrated better validity than the existing three-tier system.
Methods: A cross-sectional study was carried out in two general paediatric wards in a public hospital. SGNA and STAMP were performed on 82 children (52 boys and 30 girls) of age 1-7 years. The scores from both methods were compared against Academy of Nutrition and Dietetics/American Society of Parental and Enteral Nutrition Consensus Statement for identification of paediatric malnutrition. The objective measurements include anthropometry (weight, height and mid-arm circumference), dietary intake and biochemical markers (C-reactive protein, total lymphocytes and serum albumin). Kappa agreement between methods, sensitivity, specificity and cross-classification were computed.
Results: SGNA and STAMP identified 45% and 79% of the children to be at risk of malnutrition, respectively. Using a compendium of objective parameters, 46% of the children were confirmed to be malnourished. The agreement between SGNA and objective measurements (k = 0.337) was stronger than between STAMP and objective measurements (k = 0.052) in evaluating the nutritional status of hospitalized children. SGNA also has a 4-fold higher specificity (70.45%) than STAMP (18.18%) in detecting children who are malnourished.
Conclusion: SGNA is a valid nutrition assessment tool in diagnosing malnutrition status among hospitalized children in Malaysia. The discrepancy in specificity values between the two methods explains the distinguished roles between SGNA and STAMP. The use of STAMP will have to be followed up with a more valid tool such as SGNA to verify the actual nutrition status of the paediatric population.