Displaying publications 1 - 20 of 767 in total

Abstract:
Sort:
  1. NUR IZZI MD.YUSOFF, MOHD ROSLI HAININ, MOUNIER D, AIREY GD
    Sains Malaysiana, 2013;42:1647-1654.
    According to the classical theory of viscoelasticity, a linear viscoelastic (LVE) function can be converted into another viscoelastic function even though they emphasize different information. In this study, dynamic tests were conducted on different conventional penetration grade bitumens using a dynamic shear rheometer (DSR) in the LVE region. The results showed that the dynamic data in the frequency domain can be converted into the time domain functions using a numerical technique. This was done with the aid of the non-linear regularization (NLREG) computer program. The NLREG software is a computer program for solving nonlinear ill-posed problem and is based on non-linear Tikhonov regularization method. The use of data interconversion equation is found suitable for converting from the frequency domain into the time domain of conventional penetration grade bitumens.
    Matched MeSH terms: Software
  2. YIP TAIM HING, TAN EVONNE, POONG JUN HAN, TEE LIAN SHENG, MUHAMMAD HASBI RAMLI, ONG MENG CHUAN, et al.
    MyJurnal
    The distribution of heavy metals (Cu, Zn, Cd, Pb) in surface sediments was examined in waters off the coast of Marang, Terengganu. A total of 20 samples were collected using Ponar grab and analysed by inductively coupled plasma-mass spectrometer after closed digestion with acid. The sediments were filtered using a dry sieving method to determine their particle size. The spatial distribution maps on the concentration of selected metals were drawn using the ArcGIS software. Results showed that the average concentration of Cu, Zn, Cd, and Pb were 2.33±0.38 µg/g dry weight, 28.4±3.78 µg/g dry weight, 0.09±0.01 µg/g dry weight and 8.35±1.48 µg/g dry weight, respectively. The level of pollution was also evaluated using the Index of Geoaccumulation (Igeo) and Pollution Load Index (PLI). All Igeo and PLI values obtained were low, which indicated low or no pollution. Meanwhile, the sediment mean size ranged between -0.77Ø and 3.18Ø, which characterised a sandy type of sediment. Correlation analysis showed a positive correlation between the heavy metals and sediment size. The results indicated that there was a common source of heavy metal pollution in the study area, possibly from shipping activities. Overall, there was no significant heavy metal pollution in the waters off Marang. This finding is important as the data could be used to evaluate the risk of metal contamination and the impact of anthropogenic activities on the marine environment.
    Matched MeSH terms: Software
  3. Nasution A, Yusuf A, Lean Keng S, Rasudin NS, P Iskandar YH, Ab Hadi IS
    Asian Pac J Cancer Prev, 2021 Oct 01;22(10):3151-3163.
    PMID: 34710991 DOI: 10.31557/APJCP.2021.22.10.3151
    BACKGROUND: Mobile health technologies are widely being used for delivering health behaviour interventions. However, there is insufficient evidence that they are integrating theory and only a few researchers utilized a qualitative approach in their study.

    OBJECTIVES: This paper aims to identify requirements in developing a breast examination awareness mobile app based on the component of the Health Belief Model (HBM) for integration in health promotion strategy.

    METHODS: A qualitative approach using semi-structured in-depth interview was utilized in this study. A purposive sampling method was conducted among public women attending hospital services, software and content experts in a tertiary teaching hospital in the East coast of Peninsular Malaysia. These interviews were recorded, transcribed and organized using NVIVO 11. The main themes were identified through thematic analysis of the interview transcripts.  Results: A total of 37 participants recruited in this study. The themes that emerged from the analysis are vulnerability, forecasting, reactive, influence, outcome and obstacles. The sub-themes findings supported the HBM's component in terms of the requirement for are an infographic risk factor, video (symptoms, self-examination), info (metastasis, survival, screening, triple assessment, treatment, myth and facts, benefit of early treatment, support groups), features (screening reminder, sharing button, prompt) and mobile app's design.

    CONCLUSION: The research findings could provide a guide for future app development from public women, content and software experts.  The information will be used to develop a breast examination awareness mobile app integrated with health theories.

    Matched MeSH terms: Software Design
  4. Seri Masran SNA, Ab Majid AH
    J Med Entomol, 2017 Jul 01;54(4):974-979.
    PMID: 28399302 DOI: 10.1093/jme/tjw227
    The tropical bed bug is scientifically recognized as a significant public health problem. While there is an increased awareness about their resurgence by medical and life science committees, efficient bed bug management still remains unresolved. The solution may soon arise, as information about bed bugs' infestation dynamics and systematics are becoming more distinguishable. Recent developments in studies about bed bugs are based on molecular intervention by determining their genetic variation and phylogeography. The aim of this study is to assess the phylogenetic relationships and genetic diversity among the populations of tropical bed bugs inhabiting Malaysia. A molecular genotyping study was conducted with 22 tropical bed bug populations composed of three individuals per population. The mitochondrial (COI) gene was used as a marker. The data obtained were analyzed using the T-Coffee, ClustalX, MEGA 6.0, and PAUP software. The results showed one main monophyletic clade that consisted of two groups: Ch01 and Ch02. Ch02 consists of samples from the Bandar Hilir population, differing from the other populations studied by one singleton base. However, as there were no changes in the amino acid, this singleton genetic variation was considered to have no effect on genetic differentiation. Ch01 shows similarity with some sequence of Cimex hemipterus (F.) from Thailand, suggesting an international diversity connection. The disparity index apparently suggests that all isolates are homogeneous populations and are supported by the low value of the mean pairwise distance between isolates. This study will increase the knowledge about phylogeographic diversity of tropical bed bug in Malaysia.
    Matched MeSH terms: Software
  5. Yusof SR, Avdeef A, Abbott NJ
    Eur J Pharm Sci, 2014 Dec 18;65:98-111.
    PMID: 25239510 DOI: 10.1016/j.ejps.2014.09.009
    In vitro blood-brain barrier (BBB) models from primary brain endothelial cells can closely resemble the in vivo BBB, offering valuable models to assay BBB functions and to screen potential central nervous system drugs. We have recently developed an in vitro BBB model using primary porcine brain endothelial cells. The model shows expression of tight junction proteins and high transendothelial electrical resistance, evidence for a restrictive paracellular pathway. Validation studies using small drug-like compounds demonstrated functional uptake and efflux transporters, showing the suitability of the model to assay drug permeability. However, one limitation of in vitro model permeability measurement is the presence of the aqueous boundary layer (ABL) resulting from inefficient stirring during the permeability assay. The ABL can be a rate-limiting step in permeation, particularly for lipophilic compounds, causing underestimation of the permeability. If the ABL effect is ignored, the permeability measured in vitro will not reflect the permeability in vivo. To address the issue, we explored the combination of in vitro permeability measurement using our porcine model with the pKa(FLUX) method in pCEL-X software to correct for the ABL effect and allow a detailed analysis of in vitro (transendothelial) permeability data, Papp. Published Papp using porcine models generated by our group and other groups are also analyzed. From the Papp, intrinsic transcellular permeability (P0) is derived by simultaneous refinement using a weighted nonlinear regression, taking into account permeability through the ABL, paracellular permeability and filter restrictions on permeation. The in vitro P0 derived for 22 compounds (35 measurements) showed good correlation with P0 derived from in situ brain perfusion data (r(2)=0.61). The analysis also gave evidence for carrier-mediated uptake of naloxone, propranolol and vinblastine. The combination of the in vitro porcine model and the software analysis provides a useful tool to better predict BBB permeability in vivo and gain better mechanistic information about BBB permeation.
    Matched MeSH terms: Software
  6. Lua PL, Neni WS, Lee JK, Abd Aziz Z
    Technol Health Care, 2013;21(6):547-56.
    PMID: 24284547 DOI: 10.3233/THC-130758
    Being well-informed and knowledgeable about their illnesses would be a great advantage to children with epilepsy (CWE). Subsequently, an effective education programme which could secure interest and simultaneously improve their awareness, knowledge and attitudes (AKA) is essential in enhancing well-being and health outcomes.
    Matched MeSH terms: Software
  7. Ahmad Nasir S, Ramli R, Abd Jabar N
    PLoS One, 2018;13(10):e0204946.
    PMID: 30289909 DOI: 10.1371/journal.pone.0204946
    The aim of this study was to determine the predictors of post-traumatic enophthalmos (PE) in relation to the internal orbital changes following pure orbital blowout fractures. The design was a 10-year retrospective cross-sectional study analysing 629 medical records and computed tomography (CT) data of patients with orbital fractures from January 2008 to January 2017. Demographic, etiology, co-morbidity and clinical characteristics were obtained from the medical records. Assessment of the PE, fracture site and size, intraorbital structures and muscle change were performed using the Digital Imaging and Communications in Medicine (DICOM) viewer software, OsiriX v5.8.2. Of the 629 patients with orbital fractures, 87 were pure orbital blowout fractures. Demographic pattern showed that males outnumbered females in the series, with male: female ratio of 5.7:1. The mean age was 37.2 ± 14.7 and the main etiology was motor vehicle accident. Orbital floor fracture was the most common fracture location (67.8%). The involvement of the posterior ledge and inferior orbital fissure showed statistical significant difference with PE (Fisher's exact test, p = 0.03). Binary logistic regression showed that after controlling for age, patients with fracture size of more than 150 mm2 had three times the odds of sustaining a PE, (adjusted odds ratio (AOR) = 3.01 (95% CI 1.17-7.92). Fracture size larger than 150 mm2 was a radiological predictor of PE. Additional research investigating further on the role of concurrent fracture of the posterior ledge and inferior orbital fissure is advocated.
    Matched MeSH terms: Software
  8. Hébert-Losier K, Abd Rahman F
    Physiother Theory Pract, 2018 Jun;34(6):483-494.
    PMID: 29281461 DOI: 10.1080/09593985.2017.1420117
    The Posture Pro software is used for photogrammetry assessment of posture and has been commercially available for several years. Along with symmetry-related measures, a Posture Number® is calculated to reflect the sum of postural deviations. Our aim was to investigate the intra- and inter-rater reliability of measures extracted using the Posture Pro 8 software without using reference markers on subjects. Four raters assessed the standing posture of 40 badminton players (20 males, 20 females) from anterior, lateral, and posterior photographs. Thirty-three postural measures were extracted using visual landmarks as guide. Reliability was quantified using intra-class correlation coefficient (ICC) and typical error of measurement (TEM). Overall, the intra-rater reliability was considered good to excellent for nearly all measures. However, only two measures had excellent inter-rater reliability, with 13 and 18 measures exhibiting good and fair inter-rater reliability, respectively. Posture Pro specific measures (n = 9) exhibited good-to-excellent intra-rater and fair-to-excellent inter-rater reliability, with small-to-moderate and small-to-large TEM, respectively. Overall, the Posture Pro 8 software can be considered a reliable tool for assessing a range of posture-relevant measures from photographs, particularly when performed by the same examiner. The Posture Number® demonstrated generally acceptable intra- and inter-rater reliability. Nonetheless, investigations on the validity, sensitivity, and interpretation of this measure are essential to confirm its clinical relevance.
    Matched MeSH terms: Software*
  9. Wan Hassan WN, Othman SA, Chan CS, Ahmad R, Ali SN, Abd Rohim A
    Am J Orthod Dentofacial Orthop, 2016 Nov;150(5):886-895.
    PMID: 27871715 DOI: 10.1016/j.ajodo.2016.04.021
    INTRODUCTION: In this study we aimed to compare measurements on plaster models using a digital caliper, and on 3-dimensional (3D) digital models, produced using a structured-light scanner, using 3D software.

    METHODS: Fifty digital models were scanned from the same plaster models. Arch and tooth size measurements were made by 2 operators, twice. Calibration was done on 10 sets of models and checked using the Pearson correlation coefficient. Data were analyzed by error variances, repeatability coefficient, repeated-measures analysis of variance, and Bland-Altman plots.

    RESULTS: Error variances ranged between 0.001 and 0.044 mm for the digital caliper method, and between 0.002 and 0.054 mm for the 3D software method. Repeated-measures analysis of variance showed small but statistically significant differences (P <0.05) between the repeated measurements in the arch and buccolingual planes (0.011 and 0.008 mm, respectively). There were no statistically significant differences between methods and between operators. Bland-Altman plots showed that the mean biases were close to zero, and the 95% limits of agreement were within ±0.50 mm. Repeatability coefficients for all measurements were similar.

    CONCLUSIONS: Measurements made on models scanned by the 3D structured-light scanner were in good agreement with those made on conventional plaster models and were, therefore, clinically acceptable.

    Matched MeSH terms: Software
  10. Yusuf, A.N., Abdul Hamid, K., Mohamad, M., Abd hamid, A.I.
    Medicine & Health, 2008;3(2):300-317.
    MyJurnal
    In this study, functional magnetic resonance imaging (fMRI) is used to investigate func-tional specialisation in human auditory cortices during listening. A silent fMRI paradigm was used to reduce the scanner sound artefacts on functional images. The subject was instructed to pay attention to the white noise stimulus binaurally given at an inten-sity level of 70 dB higher than the hearing level for normal people. Functional speciali-sation was studied using the Matlab-based Statistical Parametric Mapping (SPM5) software by means of fixed effects (FFX), random effects (RFX) and conjunction analyses. Individual analyses on all subjects indicated asymmetrical bilateral activation of the left and right hemispheres in Brodmann areas (BA) 22, 41 and 42, involving the primary and secondary auditory cortices. The percentage of signal change is larger in the BA22, 41 and 42 on the right as compared to the ones on the left (p>0.05). The average number of activated voxels in all the respective Brodmann areas are higher in the right hemisphere than in the left (p>0.05). FFX results showed that the point of maximum intensity was in the right BA41 whereby 599±1 activated voxels were ob-served in the right temporal lobe as compared to 485±1 in the left temporal lobe. The RFX results were consistent with that of FFX. The analysis of conjunction which fol-lowed, showed that the right BA41 and left BA22 as the common activated areas in all subjects. The results confirmed the specialisation of the right auditory cortices in pro-cessing non verbal stimuli.
    Matched MeSH terms: Software
  11. Sabar Bauk, Abd. Aziz Tajuddin
    MyJurnal
    The linear and the mass attenuation coefficients of Rhizophora spp. wood in the photon energy range of 11.22 - 28.43 keV were determined. This was done by studying the attenuation of x-ray fluorescent (XRF) photons from selenium, molybdenum, silver and tin targets. Both the Kα and Kβ peaks were utilised. The results were compared with theoretical values for average breast tissues for youngage, middle-age and old-age groups calculated by using a XCOM computer programme. The mass attenuation coefficient of Rhizophora spp. was found to be close to that of the calculated young-age breast in this photon energy range.
    Matched MeSH terms: Software
  12. Abdelhaq M, Alsaqour R, Abdelhaq S
    PLoS One, 2015;10(5):e0120715.
    PMID: 25946001 DOI: 10.1371/journal.pone.0120715
    A mobile ad hoc network (MANET) is a set of mobile, decentralized, and self-organizing nodes that are used in special cases, such as in the military. MANET properties render the environment of this network vulnerable to different types of attacks, including black hole, wormhole and flooding-based attacks. Flooding-based attacks are one of the most dangerous attacks that aim to consume all network resources and thus paralyze the functionality of the whole network. Therefore, the objective of this paper is to investigate the capability of a danger theory-based artificial immune algorithm called the mobile dendritic cell algorithm (MDCA) to detect flooding-based attacks in MANETs. The MDCA applies the dendritic cell algorithm (DCA) to secure the MANET with additional improvements. The MDCA is tested and validated using Qualnet v7.1 simulation tool. This work also introduces a new simulation module for a flooding attack called the resource consumption attack (RCA) using Qualnet v7.1. The results highlight the high efficiency of the MDCA in detecting RCAs in MANETs.
    Matched MeSH terms: Software
  13. Muhammad Akmal Asraf Mohamad Sharom, Zainol Abidin Ibrahim, Wan Ahmad Tajuddin Wan Abdullah, Megat Harun Al Rashid Megat Ahmad, Faridah Mohamad Idris, Abdul Aziz Mohamed
    MyJurnal
    Small angle neutron scattering (SANS) is used for probing the microstructure of materials in the range between 1-100 nm in dimension. The scattered neutrons from the target material were detected by a 128 x 128 array area sensitive, Helium gas-filled proportional counter, which is known as Position Sensitive Detector (PSD). The small angle neutron scattering (SANS) facility in Malaysian Nuclear Agency has been developed since 1995. The data acquisition system of this prototype facility consists of the two-dimensional Position Sensitive Detector (2D-PSD) and neutron monitor as a data grabber, TDC Histogram as a memory processing processor, two units of ORTEC 994 as a counter and timer and a computer as a data acquisition controller via GPIB interfacing protocol. This paper will describe on the development of GPIB interface for data acquisition of the SANS instrument on Windows based platform. The GPIB device interface and graphical user interface (GUI) for this data acquisition is developed using WaveMetrics Igor software.
    Matched MeSH terms: Software
  14. Abdul Manaf, S.Z., Din, R., Hamdan, A., Mat Salleh, N.S., Kamsin, I.F., Abdul Aziz, J.
    MyJurnal
    At present, the learning activities carried out is in line with the rapid growth of development of technology and lifestyle. ICT literacy is categorised as those who can operate a computer and Internet. This study is conducted to determine the level of computer and Internet literacy in generation Y. A total of ten respondents among university students were interviewed. The level of the skill is measured in terms of the use of information processing systems and the Internet. The new knowledge addresses the themes in information communication technology literacy namely; defining, accessing, assessing, managing, integrating, creating and passing data. As such, the model of computer technology in education can also be produced. A more robust method of learning can be heightened by seeing the level of skills possessed by university students. The findings of this study is expected to determine the level of competence of the students and university can provide the necessary equipment to ensure effective teaching and learning.
    Matched MeSH terms: Software
  15. Kamal, I., Salehhon, N., Hashim, S., Musa, Y., Abdul Karim, M. K.
    MyJurnal
    The aimed of this study is to estimate the entrance surface dose (ESD) of routine chest X-ray (CXR) examination and to compare the direct and indirect measurement. This study also extended to relate with the patients body thickness and established lifetime attributable risk (LAR) of the examinations. A total of 101 CXR examinations in posteroanterior (PA) projections were selected
    as subjects and data, such as patient habitus and scanning acquisition parameters were recorded. The mean ESD value obtained from the TLD-100 and the software calculation was 0.31 mGy and 0.17 mGy, respectively. The percentage deviation obtained ranged from 25.5% to 61.3%. In comparison with the national diagnostic reference level (DRL), the mean values of ESD obtained from this study were lower by a factor of 3. Furthermore, it was observed that the mean absorbed dose of the adrenals, kidneys, lungs, oesophagus, and heart walls were lower as compared to the ESD value. The examinations were only associated with very low risk of cancer incidence and mortality. Hence, the results of this study suggested a need for standardisations of the personnel training to perform X-ray examinations according to ALARA principles.
    Matched MeSH terms: Software
  16. Hasdianty Abdullah, Mohd Fadzli Ahmad, Farah Aula Mohd Fauzi, Nor Suhaila Yaacob, Abdul Latif Ibrahim
    MyJurnal
    Protein function depends greatly on its structure. Based on this principle, it is vital to study the
    protein structure in order to understand its function. This study attempts to build the predicted
    model of lipase gene in Rhodococcus sp. NAM81 using homology modelling method. The
    predicted structure was then used to investigate the function of protein through several
    bioinformatic tools. The DNA sequence of lipase gene was obtained from the Rhodococcus sp.
    NAM81 genome scaffold. Blastx analysis showed 100% identity to the target enzyme andthe
    appropriate template for homology modelling was determined using Blastp analysis. The 3D
    protein structure was built using two homology modelling software, EsyPred3D and Swiss
    Model Server. Both structures built obtained LGScore of greater than 4, which means they are
    extremely good models according to ProQ validation criteria. Both structures also satisfied the
    Ramachandran plot structure validation analysis. The predicted structures were 100% matched
    with each other when superimposed with DaliLite pairwise. This shows that both structure
    validation servers agreed on the same model. Structure analysis using ProFunc had found seven
    motifs and active sites that indicate similar function of this protein with other known proteins.
    Thus, this study has successfully produced a good 3D protein structure for the target enzyme.
    Matched MeSH terms: Software
  17. Nurulain MZ, Ahmad S, Asma H, Abdul M
    Med J Malaysia, 2018 04;73(2):67-72.
    PMID: 29703868
    OBJECTIVE: Cataract is the leading cause of blindness in Malaysia. There is an alarming backlog of cataract extraction surgery as the majority believes they did not require surgery. This study aimed to explore the barriers at the primary care level to cataract surgery from the perspective of patients with severe cataract blindness.

    METHODS: Eleven participants were involved in this qualitative research which utilised the interpretative phenomenological analysis approach more renowned in health psychology research. All interviews conducted at their home. The interviews were recorded, typed verbatim, and the transcripts were analysed using NVivo software version 8.0.

    RESULTS: The main barriers identified at the primary care level were 1) nondisclosure of their visual problems originated from their belated needs for better sight, delayed awareness of their visual status and social stigma and 2) patient-provider-related issues namely miscommunication and delayed referral. The first main theme explains their belief for not requiring surgery. This has led to their delayed awareness and impeded disclosure of their visual problems to family members or primary care providers. The second main theme reflects the provider-patient-related issues which retarded cataract detection and referral process required for earlier cataract extraction surgery.

    CONCLUSION: Thus, the appropriate approach targeting these specific barriers at primary care level will be able to detect, motivate and assist patients for early uptake of cataract extraction surgery to improve their vision and prevent severe blindness.

    Matched MeSH terms: Software
  18. Abdul Rahim R, Pang JF, Chan KS, Leong LC, Sulaiman S, Abdul Manaf MS
    ISA Trans, 2007 Apr;46(2):131-45.
    PMID: 17367791
    The data distribution system of this project is divided into two types, which are a Two-PC Image Reconstruction System and a Two-PC Velocity Measurement System. Each data distribution system is investigated to see whether the results' refreshing rate of the corresponding measurement can be greater than the rate obtained by using a single computer in the same measurement system for each application. Each system has its own flow control protocol for controlling how data is distributed within the system in order to speed up the data processing time. This can be done if two PCs work in parallel. The challenge of this project is to define the data flow process and critical timing during data packaging, transferring and extracting in between PCs. If a single computer is used as a data processing unit, a longer time is needed to produce a measurement result. This insufficient real-time result will cause problems in a feedback control process when applying the system in industrial plants. To increase the refreshing rate of the measurement result, an investigation on a data distribution system is performed to replace the existing data processing unit.
    Matched MeSH terms: Software*; Software Design
  19. Md Rowshon Kamal, Mohd Amin Mohd Soom, Abdul Rashid Mohamed Shariff
    MyJurnal
    A GIS-based user-interface programme was developed to compute the geospatial Water ProductivityIndex (WPI) of a river-fed rice irrigation scheme in Northwest Selangor, Malaysia. The spatial analysisincludes irrigation blocks with sizes ranging from 20 to 300 ha. The amount of daily water use for eachirrigation block was determined using irrigation delivery model and stored in the database for both mainseason (August to December) and off season (February to May). After cut-off of the irrigation supply,a sub-module was used to compute the total water use including rainfall for each irrigation block. Therice yield data for both seasons were obtained from DOA (Department of Agriculture, Malaysia) of thescheme. Then, the Water Productivity Index (WPI) was computed for each irrigation block and spatialthematic map was also generated. ArcObjects and Visual Basic Application (VBA) programminglanguages were used to structure user-interface in the ArcGIS software. The WPI, expressed in termsof crop yield per unit amount of water used (irrigation and effective rainfall), ranged from 0.02 to 0.57kg/m3 in the main season and 0.02 to 0.40 in off season among irrigation blocks, respectively. Thedevelopment of the overall system and the procedure are illustrated using the data obtained from thestudy area. The approach could be used to depict the gaps between the existing and appropriate watermanagement practices. Suitable interventions could be made to fill the gaps and enhance water useefficiency at the field level and also help in saving irrigation water through remedial measures in theseason. The approach could be useful for irrigation managers to rectify and enhance decision-makingin both the management and operation of the next irrigation season.
    Matched MeSH terms: Software
  20. Noah SA, Abdullah SN, Shahar S, Abdul-Hamid H, Khairudin N, Yusoff M, et al.
    J Med Internet Res, 2004 Jan 30;6(1):e4.
    PMID: 15111270
    Attempts in current health care practice to make health care more accessible, effective, and efficient through the use of information technology could include implementation of computer-based dietary menu generation. While several of such systems already exist, their focus is mainly to assist healthy individuals calculate their calorie intake and to help monitor the selection of menus based upon a prespecified calorie value. Although these prove to be helpful in some ways, they are not suitable for monitoring, planning, and managing patients' dietary needs and requirements. This paper presents a Web-based application that simulates the process of menu suggestions according to a standard practice employed by dietitians.
    Matched MeSH terms: Software/trends*; Software Design
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links