Displaying publications 1 - 20 of 79 in total

Abstract:
Sort:
  1. Tay WM
    Dent J Malaysia Singapore, 1968 Feb;8(1):24-8.
    PMID: 5248555
    Matched MeSH terms: Stainless Steel
  2. Razak AA, Harrison A
    J Prosthet Dent, 1997 Apr;77(4):353-8.
    PMID: 9104710
    Dimensional accuracy of a composite inlay restoration is important to ensure an accurate fit and to minimize cementation stresses.
    Matched MeSH terms: Stainless Steel
  3. Benjakul P, Cheunarrom C, Ongthiemsak C
    J Oral Sci, 2001 Mar;43(1):15-9.
    PMID: 11383631
    Stainless steel wrought wires used as clasp arms for removable partial dentures in Thailand were compared with those used in some other countries (in the as-received condition) in terms of flexibility, Vickers microhardness and composition. The results showed that there were significant differences (P< or =0.05) among the wires. A Japanese stainless steel wire (SK) was obviously different from the others. It had the lowest proportional limit and microhardness, but its flexibility was almost the same. The chemical composition of each wire was not greatly different. The wires were about 18-20 wt% chromium and 8-9 wt% nickel, except for the SK wire, which had about 12 wt% nickel.
    Matched MeSH terms: Stainless Steel/analysis; Stainless Steel/chemistry*
  4. Bidawid S, Malik N, Adegbunrin O, Sattar SA, Farber JM
    J Food Prot, 2004 Jan;67(1):103-9.
    PMID: 14717359
    While there is good epidemiological evidence for foods as vehicles for norovirus transmission, the precise means of spread and its control remain unknown. The feline calicivirus was used as a surrogate for noroviruses to study infectious virus transfer between hands and selected types of foods and environmental surfaces. Assessment of the potential of selected topicals in interrupting such virus transfer was also made. Ten microliters of inoculum of feline calicivirus deposited onto each fingerpad of adult subjects was allowed to air dry and the contaminated area on individual fingerpads was pressed (10 s at a pressure of 0.2 to 0.4 kg/cm2) onto 1-cm-diameter disks of ham, lettuce, or brushed stainless steel. The virus remaining on the donor and that transferred to the recipient surfaces was eluted and plaque assayed. Virus transfer to clean hands from experimentally contaminated disks of ham, lettuce, and stainless steel was also tested. Nearly 46 +/- 20.3, 18 +/- 5.7, and 13 +/- 3.6% of infectious virus was transferred from contaminated fingerpads to ham, lettuce, and metal disks, respectively. In contrast, approximately 6 +/- 1.8, 14 +/- 3.5, and 7 +/- 1.9% virus transfer occurred, respectively, from ham, lettuce, and metal disks to hands. One-way analysis of variance test showed that pretreatment (washing) of the fingerpads either with water or with both topical agent and water significantly (P < 0.05) reduced virus transfer to < or = 0.9%, as compared with < or = 2.3 and < or = 3.4% transfer following treatments with either 75% (vol/vol) ethanol or a commercial hand gel containing 62% ethanol, respectively. Despite wide variations in virus transfer among the targeted items used, intervention agents tested reduced virus transfer significantly (P < 0.05) when compared with that without such treatments (71 +/- 8.9%). These findings should help in a better assessment of the potential for cross-contamination of foods during handling and also assist in developing more effective approaches to foodborne spread of norovirus infections.
    Matched MeSH terms: Stainless Steel
  5. Hussain PB, Mohammad M
    Med J Malaysia, 2004 May;59 Suppl B:180-1.
    PMID: 15468877
    Failure analysis was performed to investigate the failure of the femur fixation plate which was previously fixed on the femur of a girl. Radiography, metallography, fractography and mechanical testing were conducted in this study. The results show that the failure was due to the formation of notches on the femur plate. These notches act as stress raisers from where the cracks start to propagate. Finally fracture occurred on the femur plate and subsequently, the plate failed.
    Matched MeSH terms: Stainless Steel*
  6. Santin M, Morris C, Harrison M, Mikhalovska L, Lloyd AW, Mikhalovsky S
    Med J Malaysia, 2004 May;59 Suppl B:93-4.
    PMID: 15468834
    In-stent restenosis is caused by the proliferation of the smooth muscle cells (SMCs) following a host response towards the implanted device. However, the precise biochemical and cellular mechanisms are still not completely understood. In this paper, the behaviour of SMCs has been investigated by an in vitro model where the cells were stimulated by platelet derived growth factor (PDGF) on tissue-like substrates as well as on biomaterials such as stainless steel (St) and diamond-like carbon (DLC)-coated St. The results demonstrated that SMCs have a completely different adhesion mode on St and become particularly prone to proliferation and pro-inflammatory cytokine secretion under PDGF stimulus. This would suggest that restenosis may caused by the accidental contact of the SMC with the St substrate under an inflammatory insult.
    Matched MeSH terms: Stainless Steel
  7. Meor Yusoff Meor Sulaiman
    MyJurnal
    One of the non-destructive methods used for the identification and verification of metals is by the energy-dispersive X-ray fluorescence (EDXRF) technique. EDXRF analysis provides several important advantages such as simultaneous determination of the elements present, enable to analyse a very wide concentration range, fast analysis with no tedious sample preparation. The paper shows how this technique is developed and applied in the identification and verification of different grades of stainless steels. Comparison of the results obtained from this analysis with certified reference standards show very small differences between them.
    Matched MeSH terms: Stainless Steel
  8. Che Ab Aziz, Z.A., Abdullah, M., Vello, C.D.S., Thangavelu, K.
    Ann Dent, 2006;13(1):12-17.
    MyJurnal
    Background: Majority of root canal treatment in Malaysia was provided by general dental practitioner. The purpose of this study was to evaluate the knowledge and practice (canal’s preparation, use of materials) by them. Methods: A questionnaire was structured and distributed to 120 registered general dental practitioners in selected areas in Perak, Johor and Klang Valley regarding the provision of root canal therapy in their practices. The questionnaires were hand delivered and collected after 1 to 2 weeks. Results: Reply rate was 95% (n=114). The result demonstrated that 62% respondents indicated that they performed the root canal therapy (RCT) themselves. Out of these only 26% included molars in the treatment. Three quarters of them (77%) used step-back technique and 54% used stainless steel instruments to prepare the canals. The majority of the respondents (69%) used calcium hydroxide as intracanal medicaments. Only 30% used rubber dam for isolation whereas the rest used cotton rolls. The numbers of routine radiographs taken were two for anterior teeth and three for molar. Half of the respondents indicated that they usually completed the RCT for the anterior tooth within two visits whereas three visits were needed for the molar tooth. The results were analyzed descriptively. Conclusions: This study indicates that most of the general dental practitioners’ do not comply with quality standards guidelines such as use of rubber dam as isolation. Cotton roll was the most popular isolation method. In spite of this, most of the respondents tend to update their knowledge and practices with current techniques and materials.
    Matched MeSH terms: Stainless Steel
  9. Yusof Abdullah, Abdul Razak Daud, Mohd Harun, Roslinda Shamsudin
    MyJurnal
    Al-Si/SiC composites with the fraction of 5 and 15 wt. % fine SiC particles were fabricated using stir casting process by which SiC powders were poured into aluminium melt and cast in a stainless steel mould to form ingot. Characterization by X-ray diffraction (XRD) analysis showed the presence of constituent and intermetallic materials in the composites. Microstructure study revealed that both fine and course particles scattered in the Al-Si matrix. The characterization of thermal properties showed that the thermal conductivity and coefficient of thermal expansion decreased with the increase in SiC content. The conductivity and expansion behavior is correlated to the microstructure and weight fraction of the SiC particles. Meanwhile, the hardness of the composite increased with the increasing of SiC particles in the composites.
    Matched MeSH terms: Stainless Steel
  10. Fathul Karim Sahrani, Zaharah Ibrahim, Madzlan Aziz, Adibah Yahya
    Corrosion caused by sulphate-reducing bacteria (SRB) isolated from seawater nearby to Pasir Gudang has been studied. The test coupon was a AISI 304 stainless steel. Potential and corrosion rate measurements were carried out in various types of culturing solutions, with SRB1, SRB2, combination of SRB1 & SRB2 and without SRBs inoculated (sterilized). From Tafel plots a higher corrosion rate has been found in medium inoculated with SRBs than that of the sterilized medium (control). When SRBs were present in the medium, the Tafel plot shifted towards more negative values (Ecorr was shifted to much less anodic values) and increase in current density compared to that of the sterilized medium (control). Localized corrosion was observed on the metal surface, and it was associated to the SRB activity. X-ray analysis (EDAX) showed that the corrosion product has higher content of sulphur for medium containing SRBs than that of the sterilized medium. X-Ray Diffraction analysis carried out on corrosion products which showed the presence of iron sulphide. This indicates the influence of the presence of SRB in corrosion process.
    Matched MeSH terms: Stainless Steel
  11. Fathul Karim Sahrani, Madzlan Abd. Aziz, Zaharah Ibrahim, Adibah Yahya
    The corrosion potential of AISI 304 stainless steel coupons influenced by sulphate-reducing bacteria (SRB) has been studied. Pure colony of SRB was isolated from the Malaysia Marine and Heavy Engineering, Pasir Gudang, Johor. Open circuit potential measurements were carried out in variable types of culturing solutions with SRB1, SRB2, combination of SRB1 & SRB2 and without SRBs inoculated. Results showed that the corrosion potential, Eoc increased in the presence of SRBs (in pure and mixed culture) compared to that of control. EDS analysis showed the strong peak of sulphur in coupon containing SRB cultures compared to the control. ESEM data showed that the high density cell of SRBs were associated with corroding sections of surface steel comparing with non-corroding sections for coupons immersed in VMNI medium containing SRBs.
    Matched MeSH terms: Stainless Steel
  12. Takriff M, Masngut N, Kadhum A, Kalil M, Mohammad A
    Acetone-butanol-ethanol (ABE) fermentation from Palm Oil Mill Effluent (POME) by C. acetobutylicum NCIMB 13357 in an oscillatory flow bioreactor was investigated. Experimental works were conducted in a U-shaped stainless steel oscillatory flow bioreactor at oscillation frequency between 0.45-0.78 Hz and a constant amplitude of 12.5 mm. Fermentations were carried out for 72 hr at 35oC using palm oil mill effluent and reinforced clostridia medium as a growth medium in batch culture. Result of this investigation showed that POME is a viable media for ABE fermentation and oscillatory flow bioreactor has an excellent potential as an alternative fermentation device.
    Matched MeSH terms: Stainless Steel
  13. Wan Noorina Wan Ahmad, Dalia Abdullah, Kanagasingam, Shalini, Safura Anita Baharin, Jasmina Qamaruz zaman
    Malaysian Dental Journal, 2010;31(2):90-93.
    MyJurnal
    This study aims to determine the prevalence of hand-held ProTaper® files system among UKM final year dental undergraduates and to assess their perception in performing endodontic treatments.

    Methods: 85 final year dental students from 2006/2007 academic session participated in the questionnaire survey. All students underwent didactic endodontic teaching of conventional stainless steel files throughout a 2-year course and a 2-day ProTaper® hand files seminar on canal preparation. Each student had a total of 6 months clinical period before the survey was distributed to the subjects and returned for data analysis.

    Results: A 100% response rate was received. About 58.8% (n=50) used hand ProTaper routinely while 41.2% claimed themselves as non-users. Amongst the users, 52.5% were moderate users and about 33.6% were frequent users. Tooth type and size of canals were the selected criteria for file use. Majority of users used ProTaper® hand for posterior teeth and regarded it as user friendly. Although almost all users expressed concern of instrument fracture during use, very few did break. Procedural errors were not experienced by 51.3% users.

    Conclusion: About 2/3rd majority of UKM undergraduate dental students use ProTaper® hand-held system as an alternative for canal preparation. Procedural errors were perceived to occur much less when using the NiTi files. The system can be initiated to novice users and can be taught as part of endodontic curricula.
    Matched MeSH terms: Stainless Steel
  14. Muhamat Omar, Zalina Laili, Abd Khalik Wood, Julia Abdul Karim, Zarina Masood, Mohd Fazli Zakaria, et al.
    MyJurnal
    A systematic study to assess the concentration of radionuclides in primary coolant and associated water samples from the operation of a TRIGA Mark II reactor has been carried out. The samples were transferred into appropriate counting container and were counted by efficiency-calibrated gamma spectrometer systems for several hours to obtain statistically adequate data for qualitative and quantitative evaluation of the radioactive materials presence. The primary coolant was found to contain various gamma emitting radionuclides including 24Na, 41Ar, 42K, 51Cr, , 54Mn, 56Mn, 60Co, 99mTc, 122Sb, 124Sb and 187W. Most of the detected radionuclides were inferred to be originated from activation products of (n,) nuclear reactions of elements of reactor components such as stainless steel and aluminium alloy used in the reactor system. The study confirms the integrity of the reactor system with no apparent release of any fission products radionuclide into the coolant water system.
    Matched MeSH terms: Stainless Steel
  15. Md Fakarudin Ab Rahman, M. Iqbal Saripan, Nor Pa’iza Mohamad Hasan, Ismail Mustapha
    MyJurnal
    The total mass attenuation coefficients (μ/ρ) of stainless steel (SS316L) and carbon steel (A516) that are widely used as petrochemical plant components, such as distillation column, heat exchanger, boiler and storage tank were measured at 662, 1073 and 1332 keV of photon energies. Measurements of radiation intensity for various thicknesses of steel were made by using transmission method. The γ-ray intensity were counted by using a Gamma spectrometer that contains a Hyper-pure Germanium (HPGe) detector connected with Multi Channel Analyzer (MCA). The effective numbers of atomic (Zeff) and electron (Neff) obtained experimentally were compared by those obtained through theoretical calculation. Both experimental and calculated values of Zeff and Neff were in good agreement.
    Matched MeSH terms: Stainless Steel
  16. Mathew, Thomas
    Malaysian Dental Journal, 2011;32(1):28-40.
    MyJurnal
    It is the aim of all clinicians to accomplish biological tooth movement, which implies the use of low, continuous force. Constant unrelented search for a better wire, which can deliver optimal orthodontic force, has led to the invention of a lot of orthodontic wires such as Stainless steel, Beta Titanium, Nickel Titanium and multi stranded wires. In this study, the loading and unloading properties of 0.016 inch, 0.016x0.022 inch and 0.017x0.025 inch dimensions of stainless steel, conventional NiTi, Super elastic NiTi, and TMA arch wires were determined by means of a modified three point bending test for two inter bracket widths of 5 mm and 6.5 mm for deflection of 1 to 3 mm. The applied forces dependence on cross-sectional size differs from the linear-elastic prediction in super elastic NiTi wires. The stainless steel wires had the highest force values on all the three dimensions and cross section. On loading and unloading, TMA wires had force values in-between stainless steel, conventional NiTi and super elastic NiTi. The conventional NiTi had much lower force values compared to stainless steel and TMA and were linearly progressing compared to Super elastic NiTi. On loading and unloading the super elastic NiTi had force values in the range of conventional NiTi and had constant forces on higher deflection. The studies showed that the force value was comparatively higher in 5 mm inter bracket width than the 6.5 mm inter bracket width for all the cross section and dimension of wires.
    Matched MeSH terms: Stainless Steel
  17. Asma Alhusna Abang Abdullah, Nurul Asyikin Yahya
    Sains Malaysiana, 2011;40:1313-1317.
    Fixed orthodontic treatment requires the use of orthodontic brackets and archwires in order to correct malocclusions. The objective of this study was to evaluate the pattern of orthodontic material usages i.e. bracket and archwire among Malaysian orthodontists. A self-administered questionnaire was distributed to members of the Malaysian Association of Orthodontist. Data entry and statistical analysis was done using SPSS version 15.0. Descriptive statistics were used for analysis. Means and standard deviations were calculated for continuous variables, frequency and percentages for categorical variables. Thirty-four orthodontists responded to the survey, with 76% (n=26) were female and the mean age was 43.31 years (SD 8.76). Most respondents used conventional metal brackets (60%, n=60) and most bracket prescription used was MBT (56%, n=19). At levelling stage, most respondents used nickel titanium archwire (84.5%, n=47). Stainless steel archwire was the most favourable choice for retraction/space closure stage (73.9%, n=34). At finishing, most respondents (60.4%, n=29) preferred to use stainless steel wire in their cases. As a conclusion, specific types of orthodontic materials were preferred and used by Malaysian orthodontists in delivering orthodontic treatment.
    Matched MeSH terms: Stainless Steel
  18. Mohd Syafiq Hamdan, Norazzizi Nordin, Fathrita Mohd Amir, Mohamed Rozali Othman
    Sains Malaysiana, 2011;40:1421-1427.
    In this study, two nickel based electrodes were prepared; nickel foil and nickel-polyvinylchloride (Ni-PVC), in order to study their electrochemical behavior using cyclic voltammetry, CV and chronocoulometry, CC. Ni electrode was prepared from Ni metal foil while Ni-PVC electrode was prepared by mixing a weighed portion of Ni powder and PVC in THF solvent, swirled until the suspension was homogeneous and drying the suspension in an oven at 50oC for 3 h. The dry sample was then placed in a 1 cm diameter stainless steel mould and pressed at 10 ton/cm2. From CV data, Ni-PVC electrode showed a better electrochemical behavior compared to Ni metal foil electrode. The use of Ni-PVC electrode at higher concentration of supporting electrolyte (1.0 M KOH) was better than at lower concentration of the same supporting electrolyte in electroxidation of ethanol. In addition to acetic acid, the oxidation of ethanol also produced ethyl acetate and acetaldehyde.
    Matched MeSH terms: Stainless Steel
  19. Hui YW, Dykes GA
    J Food Prot, 2012 Aug;75(8):1507-11.
    PMID: 22856578 DOI: 10.4315/0362-028X.JFP-12-062
    The use of simple crude water extracts of common herbs to reduce bacterial attachment may be a cost-effective way to control bacterial foodborne pathogens, particularly in developing countries. The ability of water extracts of three common Malaysian herbs (Andrographis paniculata, Eurycoma longifolia, and Garcinia atroviridis) to modulate hydrophobicity and attachment to surfaces of five food-related bacterial strains (Bacillus cereus ATCC 14576, Escherichia coli ATCC 25922, Pseudomonas aeruginosa ATCC 10145, Salmonella Enteritidis ATCC 13076, Staphylococcus aureus ATCC 25923) were determined. The bacterial attachment to hydrocarbon assay was used to determine bacterial hydrophobicity. Staining and direct microscopic counts were used to determine attachment of bacteria to glass and stainless steel. Plating on selective media was used to determine attachment of bacteria to shrimp. All extracts were capable of either significantly ( P < 0.05) increasing or decreasing bacterial surface hydrophobicity, depending on the herb extract and bacteria combination. Bacterial attachment to all surfaces was either significantly (P < 0.05) increased or decreased, depending on the herb extract and bacteria combination. Overall, hydrophobicity did not show a significant correlation (P > 0.05) to bacterial attachment. For specific combinations of bacteria, surface material, and plant extract, significant correlations (R > 0.80) between hydrophobicity and attachment were observed. The highest of these was observed for S. aureus attachment to stainless steel and glass after treatment with the E. longifolia extract (R = 0.99, P < 0.01). The crude water herb extracts in this study were shown to have the potential to modulate specific bacterial and surface interactions and may, with further work, be useful for the simple and practical control of foodborne pathogens.
    Matched MeSH terms: Stainless Steel
  20. Lee XJ, Lee LY, Foo LP, Tan KW, Hassell DG
    J Environ Sci (China), 2012;24(9):1559-68.
    PMID: 23520862
    The present work covers the preparation of carbon-based nanosorbents by ethylene decomposition on stainless steel mesh without the use of external catalyst for the treatment of water containing nickel ions (Ni2+). The reaction temperature was varied from 650 to 850 degrees C, while reaction time and ethylene to nitrogen flow ratio were maintained at 30 min and 1:1 cm3/min, respectively. Results show that nanosorbents synthesised at a reaction temperature of 650 degrees C had the smallest average diameter (75 nm), largest BET surface area (68.95 m2/g) and least amount of impurity (0.98 wt.% Fe). A series of batch-sorption tests were performed to evaluate the effects of initial pH, initial metal concentration and contact time on Ni2+ removal by the nanosorbents. The equilibrium data fitted well to Freundlich isotherm. The kinetic data were best correlated to a pseudo second-order model indicating that the process was of chemisorption type. Further analysis by the Boyd kinetic model revealed that boundary layer diffusion was the controlling step. This primary study suggests that the prepared material with Freundlich constants compared well with those in the literature, is a promising sorbent for the sequestration of Ni2+ in aqueous solutions.
    Matched MeSH terms: Stainless Steel
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links