Displaying publications 1 - 20 of 79 in total

Abstract:
Sort:
  1. Wan Dagang WR, Bowen J, O'Keeffe J, Robbins PT, Zhang Z
    Biotechnol Lett, 2016 May;38(5):787-92.
    PMID: 26892223 DOI: 10.1007/s10529-016-2047-x
    The adhesion of colloidal probes of stainless steel, glass and cellulose to Pseudomonas fluorescens biofilms was examined using atomic force microscopy (AFM) to allow comparisons between surfaces to which biofilms might adhere.
    Matched MeSH terms: Stainless Steel
  2. Wo, Yii Mei, Hidayah Shahar, Zaharudin Ahmad
    MyJurnal
    Present of 241Am in the environment is being determined as part of surveillance and research
    programs related to nuclear activities. The separation of 241Am from environmental samples was
    carried out against the IAEA’s reference material by using an improved in-house radiochemical
    separation method through anion exchange column, followed by the electro-deposition on a
    stainless steel disc, and finally assayed on alpha spectrometry counting system. The resulting
    spectra showed good isolated peak, indicating a good separation of the radionuclide of interest.
    The analytical results were in good agreement with the certified value for IAEA-326 and IAEA-368
    with the calculated U-score was 0.36 and 0.82, respectively, showing no significant difference
    between the experimental and certified value. Using this method, distributions of 241Am in seabed
    surface sediment in the Exclusive Economic Zone of East Coast Peninsular Malaysia were studied.
    Samples were collected during June 2008 where the concentrations of 241Am were found to be
    ranged from < 0.08 to 0.36 Bq/kg, dry weight.
    Matched MeSH terms: Stainless Steel
  3. Harith H, Schmutz B, Malekani J, Schuetz MA, Yarlagadda PK
    Med Eng Phys, 2016 Mar;38(3):280-5.
    PMID: 26739124 DOI: 10.1016/j.medengphy.2015.11.012
    Anatomically precontoured plates are commonly used to treat periarticular fractures. A well-fitting plate can be used as a tool for anatomical reduction of the fractured bone. Recent studies highlighted that some plates fit poorly for many patients due to considerable shape variations between bones of the same anatomical site. While it is impossible to design one shape that fits all, it is also burdensome for the manufacturers and hospitals to produce, store and manage multiple plate shapes without the certainty of utilization by a patient population. In this study, we investigated the number of shapes required for maximum fit within a given dataset, and if they could be obtained by manually deforming the original plate. A distal medial tibial plate was automatically positioned on 45 individual tibiae, and the optimal deformation was determined iteratively using finite element analysis simulation. Within the studied dataset, we found that: (i) 89% fit could be achieved with four shapes, (ii) 100% fit was impossible through mechanical deformation, and (iii) the deformations required to obtain the four plate shapes were safe for the stainless steel plate for further clinical use. The proposed framework is easily transferable to other orthopaedic plates.
    Matched MeSH terms: Stainless Steel
  4. Saboohi S, Yap S, Chan L, Wong C
    Sains Malaysiana, 2012;41:879-884.
    The emission of Extreme Ultra Violet (EUV) from plasma produced by vacuum spark discharge using stainless steel as anode material was investigated. The operating pressure for all the experiments carried out was maintained at below 10-4 mbar. The discharge voltage tested was from 8 kV to 20 kV. The inter-electrode distance suitable for high intensity and reproducible EUV emissions was found to be in the range of 2.6 mm to 4.6 mm. The output EUV energy scaled as ~ V02, where V0 is the discharge voltage.
    Matched MeSH terms: Stainless Steel
  5. Meor Yusoff, M.S., Masliana, M., Wilfred, P.
    MyJurnal
    Even though EDXRF analysis has major advantages in the analysis of stainless steel samples such as simultaneous determination of the minor elements, analysis can be done without sample preparation and non-destructive analysis, the matrix issue arised from the inter element interaction can make the the final quantitative result to be in accurate. The paper relates a comparative quantitative analysis using standard and standardless methods in the determination of these elements. Standard method was done by plotting regression calibration graphs of the interested elements using BCS certified stainless steel standards. Different calibration plots were developed based on the available certified standards and these stainless steel grades include low alloy steel, austentic, ferritic and high speed. The standardless method on the other hand uses a mathematical modelling with matrix effect correction derived from Lucas-Tooth and Price model. Further
    improvement on the accuracy of the standardless method was done by inclusion of pure elements into the development of the model. Discrepancy tests were then carried out for these quantitative methods on different certified samples and the results show that the high speed method is most reliable for determining of Ni and the standardless method for Mn.
    Matched MeSH terms: Stainless Steel
  6. Raba’atun Adawiyah Shamsuddin, Wan Ramli Wan Daud, Kim BH, Jamaliah Md. Jahim, Mimi Hani Abu Bakar, Wan Syaidatul Aqma Wan Mohd Noor
    Sains Malaysiana, 2018;47:3043-3049.
    Microbial fuel cells (MFCs) have a high potential application for simultaneous wastewater treatment and electricity
    generation. However, the choice of the electrode material and its design is critical and directly affect their performance.
    As an electrode of MFCs, the anode material with surface modifications is an attractive strategy to improve the power
    output. In this study, stainless steel (SS) and carbon steel (CS) was chosen as a metal anode, while graphite felt (GF)
    was used as a common anode. Heat treatment was performed to convert SS, CS and GF into efficient anodes for MFCs.
    The maximum current density and power density of the MFC-SS were achieved up till 762.14 mA/m2
    and 827.25 mW/m2
    ,
    respectively, which were higher than MFC-CS (641.95 mA/m2
    and 260.14 mW/m2
    ) and MFC-GF (728.30 mA/m2
    and 307.89
    mW/m2
    ). Electrochemical impedance spectroscopy of MFC-SS showed better catalytic activity compared to MFC-CS and
    MFC-GF anode, also supported by cyclic voltammetry test.
    Matched MeSH terms: Stainless Steel
  7. Mohd Zambri M.M., Wan Nurazreena W.H.
    Ann Dent, 2018;25(1):1-10.
    MyJurnal
    This report aimed to describe an effective biomechanics to control the upper incisors inclination during the
    correction of gummy smile with bimaxillary proclinations. A 14-year-old female presented with a Class II
    division I incisor relationship complicated with bimaxillary proclination on a Class 2 skeletal base. The lips
    were incompetent, showing 7 mm of upper incisors at rest and 5mm maxillary gingival display on smiling
    with normal upper lip length. Treatment involved extraction of all first permanent premolars followed by
    upper and lower fixed appliances. Intrusion of the upper incisors with controlled labial crown torque was
    accomplished with mini-implant anchorage placed bilaterally on the infrazygomatic crests with the retraction
    forces above the centre of resistance using 0.019x0.025-in stainless steel archwire in 0.022-in slot. The
    0.019x0.025-in stainless steel archwire in 0.022-in slot provided the vertical play to favour lingual crown
    tipping despite having forces above the centre of resistance for concurrent anterior segment intrusion.
    Matched MeSH terms: Stainless Steel
  8. Nur Ain, A.R., Mohd Sabri, M.G., Wan Rafizah, W.A., Nurul Azimah, M.A., Wan Nik, W.B.
    ASM Science Journal, 2018;11(101):56-67.
    MyJurnal
    Corrosion is a natural deterioration process that destructs metal surface. Metal of highly
    protected by passivation layer such as Stainless Steel 316L also undergoes pitting corrosion
    when continuously exposed to aggressive environment. To overcome this phenomenon, application
    of epoxy based coating with addition of zinc oxide- poly (3,4-ethylenedioxythiophene)
    doped with poly (styrene sulphonate) hybrid nanocomposite additive was introduced as
    paint/metal surface coating. The compatibility between these two materials as additive
    was studied by Fourier Transform Infrared Spectroscopy (FTIR), X-ray Diffraction (XRD),
    Field Emission Scanning Electron Microscopy/Energy-Dispersive X-ray spectroscopy (FESEM/EDX)
    and Transmission Electron Microscopy (TEM) analysis. The effect of nanocomposite
    wt.% in epoxy based coating with immersion duration in real environment on corrosion
    protection performance was analyzed through potentiodynamic polarization analysis. The
    main finding showed that addition of hybrid nanocomposite had increased corrosion protection
    yet enhanced corrosion process when excess additives was loaded into epoxy coating.
    Addition of 2 wt.% ZnO-PEDOT:PSS was found significantly provided optimum corrosion
    protection to stainless steel 316L as the corrosion rate for 0 day, 15 days and 30 days of
    immersion duration is 0.0022 mm/yr, 0.0004 mm/yr and 0.0015 mm/yr; respectively.
    Matched MeSH terms: Stainless Steel
  9. Sim KS, Kho YY, Tso CP, Nia ME, Ting HY
    Scanning, 2013 Mar-Apr;35(2):75-87.
    PMID: 22777599 DOI: 10.1002/sca.21037
    Detection of cracks from stainless steel pipe images is done using contrast stretching technique. The technique is based on an image filter technique through mathematical morphology that can expose the cracks. The cracks are highlighted and noise removal is done efficiently while still retaining the edges. An automated crack detection system with a camera platform has been successfully implemented. We compare crack extraction in terms of quality measures with those of Otsu's threshold technique and the another technique (Iyer and Sinha, 2005). The algorithm shown is able to achieve good results and perform better than these other techniques.
    Matched MeSH terms: Stainless Steel
  10. Che Ab Aziz, Z.A., Abdullah, M., Vello, C.D.S., Thangavelu, K.
    Ann Dent, 2006;13(1):12-17.
    MyJurnal
    Background: Majority of root canal treatment in Malaysia was provided by general dental practitioner. The purpose of this study was to evaluate the knowledge and practice (canal’s preparation, use of materials) by them. Methods: A questionnaire was structured and distributed to 120 registered general dental practitioners in selected areas in Perak, Johor and Klang Valley regarding the provision of root canal therapy in their practices. The questionnaires were hand delivered and collected after 1 to 2 weeks. Results: Reply rate was 95% (n=114). The result demonstrated that 62% respondents indicated that they performed the root canal therapy (RCT) themselves. Out of these only 26% included molars in the treatment. Three quarters of them (77%) used step-back technique and 54% used stainless steel instruments to prepare the canals. The majority of the respondents (69%) used calcium hydroxide as intracanal medicaments. Only 30% used rubber dam for isolation whereas the rest used cotton rolls. The numbers of routine radiographs taken were two for anterior teeth and three for molar. Half of the respondents indicated that they usually completed the RCT for the anterior tooth within two visits whereas three visits were needed for the molar tooth. The results were analyzed descriptively. Conclusions: This study indicates that most of the general dental practitioners’ do not comply with quality standards guidelines such as use of rubber dam as isolation. Cotton roll was the most popular isolation method. In spite of this, most of the respondents tend to update their knowledge and practices with current techniques and materials.
    Matched MeSH terms: Stainless Steel
  11. Tay WM
    Dent J Malaysia Singapore, 1968 Feb;8(1):24-8.
    PMID: 5248555
    Matched MeSH terms: Stainless Steel
  12. Sim BM, Hong TS, Hanim MA, Tchan EN, Talari MK
    Materials (Basel), 2019 Oct 10;12(20).
    PMID: 31658593 DOI: 10.3390/ma12203285
    Duplex stainless steels (DSSs) are complex materials and they have been widely used in the marine environment and gas industries, primarily offering a better resistance of pitting corrosion and good mechanical properties. In the present work, the effects of heat treatment on duplex stainless steel (DSS) weld overlay samples that were heat treated at three different temperatures, namely 350 °C, 650 °C, and 1050 °C, and followed by air cooling and water quenching were studied. Stress relief temperature at 650 °C had induced sigma phase precipitation in between delta ferrite and austenite (δ/γ) grain boundaries, resulting in the loss of corrosion resistance in the weld metal. Interestingly, post weld heat treatment (PWHT) test samples that were reheated to solution annealing temperature had shown no weight loss. The ferrite count determination in the region of weld metal overlay increased at hydrogen relief and decreased at stress relief temperatures due to slow cooling, which is more favorable to austenite formation. The amount of ferrite in the weld metals was significantly reduced with the increment of solution anneal temperature to 1050 °C because of sufficient time for the formation of austenite and giving optimum equilibrium fraction in the welds.
    Matched MeSH terms: Stainless Steel
  13. Md Razak Daud, Wan Nor Shela Ezwane Wan Jusoh, Syahrullail Samion
    MyJurnal
    This study investigates metal removal rate (MRR) of the biomaterial by using discharge machine Neuar CNC A50 Electrical Discharge Machine Die Sinking (EDM DS). The purpose of this study is to compare machining curvature cup for material SKD 11 and stainless steel with shape curvature cup acetabular. The result showed that electrode wear is higher when high current is applied. For each applied current 0.5A and 3.0A could result electrode wear of 0.236 mm, 0.246 mm and 0.269 mm respectively. Mean time of complete discharged for each pit with 0.3mm depth with supply 0. 5A is 6.51 minutes; 1. 5A is 3.54 minutes and 3A is 1.52 minutes. The biggest mean parameter of the pit is 0.356 mm, with 3A of current is applied. From this study, it can be concluded that low current set may give lower electrode copper wear. The experiment will help a researcher to discharge biomaterial types of metal with small size of copper electrode use of EDM DS Neuar for discharge multi hole or micro pit.
    Matched MeSH terms: Stainless Steel
  14. Muhamad Hafizuddin Mohamad Basir, Bulan Abdullah, Siti Khadijah Alias
    MyJurnal
    This research investigates and analyzes wear properties of 316 stainless steel before and after applying paste boronizing process and to investigate the effect of shot blasting process in enhancing boron dispersion into the steel. In order to enhance the boron dispersion into 316 stainless steel, surface deformation method by shot blasting process was deployed. Boronizing treatment was conducted using paste medium for 8 hours under two different temperatures which were 8500 C and 9500 C. Wear behaviour was evaluated using pin-on-disc test for abrasion properties. The analysis on microstructure, X-ray Diffraction (XRD) and density were also carried out before and after applying boronizing treatment. Boronizing process that had been carried out on 316 stainless steel increases the wear resistance of the steel compared to the unboronized 316 stainless steel. The effect of boronizing treatment together with the shot blasting process give a greater impact in increasing the wear resistance of 316 stainless steel. This is mainly because shot blasted samples initiated surface deformation that helped more boron dispersion due to dislocation of atom on the deformed surface. Increasing the boronizing temperature also increases the wear resistance of 316 stainless steel. In industrial application, the usage of the components that have been fabricated using the improved 316 stainless steel can be maximized because repair and replacement of the components can be reduced as a result of improved wear resistance of the 316 stainless steel.
    Matched MeSH terms: Stainless Steel
  15. Mohd Noor Halmy, Siti Khadijah Alias, Radzi Abdul Rasih, Mohd Ghazali Mohd Hamami, Norhisyam Jenal, Siti Aishah Taib
    MyJurnal
    This study focuses on the effect of boronizing medium on the boride layer thickness of pack boronized 304 stainless steel after surface modification. Pack boronizing treatment was conducted in temperature of 900oC for a duration of eight hours. The treatment was performed using two different boronizing mediums which are powder and paste inside a tight box in an induction furnace. The characteristics of the samples were then observed using optical microscopy and XRD analyser. The thickness of boride layer was then measured using MPS digital image analysis software. The results showed that boronizing medium significantly affected the thickness of boride layer as paste boronized samples exhibited thicker boride layer thickness. The enhancement was mainly due to the size of boron particle in the paste medium which was smaller than powder medium that enabled better diffusion. It is expected that the enhancement of the boride layer thickness would result in further improvement of the mechanical and wear properties of this material.
    Matched MeSH terms: Stainless Steel
  16. Wan Omar WH, Mahyudin NA, Azmi NN, Mahmud Ab Rashid NK, Ismail R, Mohd Yusoff MHY, et al.
    Int J Food Microbiol, 2023 Jun 02;394:110184.
    PMID: 36996693 DOI: 10.1016/j.ijfoodmicro.2023.110184
    Staphylococcus aureus and Salmonella Typhimurium have a propensity to develop biofilms on food contact surfaces, such as stainless-steel, that persist despite rigorous cleaning and sanitizing procedures. Since both bacterial species pose a significant public health risk within the food chain, improved anti-biofilm measures are needed. This study examined the potential of clays as antibacterial and anti-biofilm agents against these two pathogens on appropriate contact surfaces. Natural soil was processed to yield leachates and suspensions of both untreated and treated clays. Soil particle size, pH, cation-exchange capacity, and metal ions were characterized to assess their importance in bacterial killing. Initial antibacterial screening was performed on nine distinct types of natural Malaysian soil using a disk diffusion assay. Untreated leachate from Kuala Gula and Kuala Kangsar clays were found to inhibit S. aureus (7.75 ± 0.25 mm) and Salmonella Typhimurium (11.85 ± 1.63 mm), respectively. The treated Kuala Gula suspension (50.0 and 25.0 %) reduced S. aureus biofilms by 4.4 and 4.2 log at 24 and 6 h, respectively, while treated Kuala Kangsar suspension (12.5 %) by a 4.16 log reduction at 6 h. Although less effective, the treated Kuala Gula leachate (50.0 %) was effective in removing Salmonella Typhimurium biofilm with a decrease of >3 log in 24 h. In contrast to Kuala Kangsar clays, the treated Kuala Gula clays contained a much higher soluble metal content, especially Al (301.05 ± 0.45 ppm), Fe (691.83 ± 4.80 ppm) and Mg (88.44 ± 0.47 ppm). Elimination of S. aureus biofilms correlated with the presence of Fe, Cu, Pb, Ni, Mn and Zn irrespective of the pH of the leachate. Our findings demonstrate that a treated suspension is the most effective for eradication of S. aureus biofilms with a potential as a sanitizer-tolerant, natural antibacterial against biofilms for applications in the food industry.
    Matched MeSH terms: Stainless Steel
  17. Mohd Daud N, Saeful Bahri IF, Nik Malek NA, Hermawan H, Saidin S
    Colloids Surf B Biointerfaces, 2016 Sep 01;145:130-9.
    PMID: 27153117 DOI: 10.1016/j.colsurfb.2016.04.046
    Chlorhexidine (CHX) is known for its high antibacterial substantivity and is suitable for use to bio-inert medical devices due to its long-term antibacterial efficacy. However, CHX molecules require a crosslinking film to be stably immobilized on bio-inert metal surfaces. Therefore, polydopamine (PDA) was utilized in this study to immobilize CHX on the surface of 316L type stainless steel (SS316L). The SS316L disks were pre-treated, modified with PDA film and immobilized with different concentrations of CHX (10mM-50mM). The disks were then subjected to various surface characterization analyses (ATR-FTIR, XPS, ToF-SIMS, SEM and contact angle measurement) and tested for their cytocompatibility with human skin fibroblast (HSF) cells and antibacterial activity against Escherichia coli and Staphylococcus aureus. The results demonstrated the formation of a thin PDA film on the SS316L surface, which acted as a crosslinking medium between the metal and CHX. CHX was immobilized via a reduction process that covalently linked the CHX molecules with the functional group of PDA. The immobilization of CHX increased the hydrophobicity of the disk surfaces. Despite this property, a low concentration of CHX optimized the viability of HSF cells without disrupting the morphology of adherent cells. The immobilized disks also demonstrated high antibacterial efficacy against both bacteria, even at a low concentration of CHX. This study demonstrates a strong beneficial effect of the crosslinked PDA film in immobilizing CHX on bio-inert metal, and these materials are applicable in medical devices. Specifically, the coating will restrain bacterial proliferation without suffocating nearby tissues.
    Matched MeSH terms: Stainless Steel/chemistry*
  18. Lukman SK, Al-Ashwal RH, Sultana N, Saidin S
    Chem Pharm Bull (Tokyo), 2019;67(5):445-451.
    PMID: 31061369 DOI: 10.1248/cpb.c18-00847
    Electrodeposition is commonly used to deposit ceramic or metal coating on metallic implants. Its utilization in depositing polymer microcapsule coating is currently being explored. However, there is no encapsulation of drug within polymer microcapsules that will enhance its chemical and biological properties. Therefore, in this study, ginseng which is known for its multiple therapeutic effects was encapsulated inside biodegradable poly(lactic-co-glycolic acid) (PLGA) microcapsules to be coated on pre-treated medical grade stainless steel 316L (SS316L) using an electrodeposition technique. Polyaniline (PANI) was incorporated within the microcapsules to drive the formation of microcapsule coating. The electrodeposition was performed at different current densities (1-3 mA) and different deposition times (20-60 s). The chemical composition, morphology and wettability of the microcapsule coatings were characterized through attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR), scanning electron microscopy (SEM) and contact angle analyses. The changes of electrolyte colors, before and after the electrodeposition were also observed. The addition of PANI has formed low wettability and uniform microcapsule coatings at 2 mA current density and 40 s deposition time. Reduction in the current density or deposition time caused less attachment of microcapsule coatings with high wettability records. While prolonging either one parameter has led to debris formation and melted microcapsules with non-uniform wettability measurements. The color of electrolytes was also changed from milky white to dark yellow when the current density and deposition time increased. The application of tolerable current density and deposition time is crucial to obtain a uniform microcapsule coating, projecting a controlled release of encapsulated drug.
    Matched MeSH terms: Stainless Steel/chemistry*
  19. Mohd Daud N, Hussein Al-Ashwal R, Abdul Kadir MR, Saidin S
    Ann. Anat., 2018 Nov;220:29-37.
    PMID: 30048761 DOI: 10.1016/j.aanat.2018.06.009
    Immobilization of chlorhexidine (CHX) on stainless steel 316L (SS316L), assisted by a polydopamine film as an intermediate layer is projected as an approach in combating infection while aiding bone regeneration for coating development on orthopedic and dental implants. This study aimed to investigate the ability of CHX coating to promote apatite layer, osteoblast cells viability, adhesion, osteogenic differentiation and mineralization. Stainless steel 316L disks were pre-treated, grafted with a polydopamine film and immobilized with different concentrations of CHX (10-30mM). The apatite layer formation was determined through an in vitro simulated body fluid (SBF) test by ATR-FTIR and SEM-EDX analyses. The osteoblastic evaluations including cells viability, cells adhesion, osteogenic differentiation and mineralization were assessed with human fetal osteoblast cells through MTT assay, morphology evaluation under FESEM, ALP enzyme activity and Alizarin Red S assay. The apatite layer was successfully formed on the CHX coated disks, demonstrating potential excellent bioactivity property. The CHX coatings were biocompatible with the osteoblast cells at low CHX concentration (<20mM) with good adhesion on the metal surfaces. The increment of ALP activity and calcium deposition testified that the CHX coated disks able to support osteoblastic maturation and mineralization. These capabilities give a promising value to the CHX coating to be implied in bone regeneration area.
    Matched MeSH terms: Stainless Steel
  20. Tapsir Z, Jamaludin FH, Pingguan-Murphy B, Saidin S
    J Biomater Appl, 2018 02;32(7):987-995.
    PMID: 29187035 DOI: 10.1177/0885328217744081
    The utilisation of hydroxyapatite and collagen as bioactive coating materials could enhance cells attachment, proliferation and osseointegration. However, most methods to form crystal hydroxyapatite coating do not allow the incorporation of polymer/organic compound due to production phase of high sintering temperature. In this study, a polydopamine film was used as an intermediate layer to immobilise hydroxyapatite-collagen without the introduction of high sintering temperature. The surface roughness, coating adhesion, bioactivity and osteoblast attachment on the hydroxyapatite-collagen coating were assessed as these properties remains unknown on the polydopamine grafted film. The coating was developed by grafting stainless steel 316L disks with a polydopamine film. Collagen type I fibres were then immobilised on the grafted film, followed by the biomineralisation of hydroxyapatite. The surface roughness and coating adhesion analyses were later performed by using AFM instrument. An Alamar Blue assay was used to determine the cytotoxicity of the coating, while an alkaline phosphatase activity test was conducted to evaluate the osteogenic differentiation of human fetal osteoblasts on the coating. Finally, the morphology of cells attachment on the coating was visualised under FESEM. The highest RMS roughness and coating adhesion were observed on the hydroxyapatite-collagen coating (hydroxyapatite-coll-dopa). The hydroxyapatite-coll-dopa coating was non-toxic to the osteoblast cells with greater cells proliferation, greater level of alkaline phosphate production and more cells attachment. These results indicate that the immobilisation of hydroxyapatite and collagen using an intermediate polydopamine is identical to enhance coating adhesion, osteoblast cells attachment, proliferation and differentiation, and thus could be implemented as a coating material on orthopaedic and dental implants.
    Matched MeSH terms: Stainless Steel/chemistry*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links