Displaying publications 1 - 20 of 379 in total

Abstract:
Sort:
  1. Sulong MZ, Aziz RA
    J Prosthet Dent, 1990 Mar;63(3):342-9.
    PMID: 2407832
    This is a review of the literature concerning wear related to the following materials used in dentistry: dental amalgam, composite resins, and glass-ionomer cements, as well as natural tooth substance. Discussions are included on both in vivo and in vitro studies in which various methods were used to help determine wear resistance.
    Matched MeSH terms: Surface Properties
  2. Yusof Z
    J Oral Rehabil, 1991 Jan;18(1):95-102.
    PMID: 2051253
    The aim of this study was to determine the periodontal status in relation to the quality of the adjacent proximal tooth surface. The gingival index (GI) and probable pocket depth (PD) were measured in 144 contra-lateral pairs of sound vs. restored and 95 contra-lateral pairs of sound vs. carious surfaces in 124 patients. The restorations studied were silver amalgams and tooth-coloured filling materials, the margins of which were supragingival or level with the gingival margins. The results showed that the GI and PD were greater for both restored and carious tooth surfaces than for the contra-lateral sound surfaces. When all the teeth were grouped together, the differences in the mean values of GI and PD were statistically significant at the P less than or equal to 0.05 level. A comparison between restored and carious (non-paired) tooth surfaces revealed higher mean values of GI and PD for the latter, which were highly significant at the P less than 0.001 level. Thus the present study shows that proximal tooth surface quality influences the health status of the adjacent periodontium.
    Matched MeSH terms: Surface Properties
  3. Sulong MZ, Setchell DJ
    J Prosthet Dent, 1991 Dec;66(6):743-7.
    PMID: 1805022
    Adhesive bond strength studies for the tray adhesive of an addition vinyl polysiloxane (President) impression material were conducted with an acrylic resin, chromium-plated brass, and plastic trays. Tensile and shear stress studies were performed on the Instron Universal testing machine. Acrylic resin specimens roughened with 80-grit silicon carbide paper exhibited appreciably higher bond strengths compared with different types of tray material and methods of surface preparation.
    Matched MeSH terms: Surface Properties
  4. Jamaluddin A, Pearson GJ
    Asian J Aesthet Dent, 1993 Jan;1(1):19-23.
    PMID: 8149147
    This study assessed the nature of the adhesion in repaired glass-ionomer restorative materials. Two chemically different glass-ionomer cements, Ketac Fil and Chemfil II Cap, and three different methods of conditioning the surface for repair were employed. Specimens of each material were prepared and the cut surfaces were then treated with either 35% phosphoric acid, 35% polyacrylic acid or a combination of phosphoric acid followed by polyacrylic acid. Freshly mixed material was injected against these treated surfaces and allowed to set under simulated intraoral conditions. The specimens were tested to failure in flexion after seven days storage. Assessment of the fractured surfaces was then carried out using the scanning electron microscope. The results showed the occurrence of both adhesive and cohesive failure.
    Matched MeSH terms: Surface Properties
  5. Ahmad M, Roy RA
    Endod Dent Traumatol, 1994 Apr;10(2):71-6.
    PMID: 8062810
    The incidence of breakage of Piezon-Master ultrasonic K files were evaluated. Three groups of unused files were subjected to three treatments, namely; free vibration in air without irrigation, free vibration in root canal while minimizing contact with the wall of canal in the presence of irrigation and light filing in root canal with free flow of irrigation. Cavitation produced by files in contact and free of contact with a glass surface was examined in order to observe the relationship between cavitation defects and breakage. In addition, the fractured and unfractured files were examined under a scanning electron microscope for the presence of cavitation pits. The results indicated that more files broke in air. In water, a higher incidence of breakage occurred when files were allowed to freely vibrate while no breakage occurred when the files were used in filing. All files generated cavitation which resulted in pitting of their surfaces. However, it was considered unlikely that the pits contributed to fracture. Fatigue cracks which could be the result of the manufacturing process were observed at some of the corners of the cross sections of the fractured files and could be the main contributory factor to fracture.
    Matched MeSH terms: Surface Properties
  6. Ling BC, Gillings BR
    Asian J Aesthet Dent, 1995;3:17-21.
    PMID: 9063105
    With the prognosis of dental implant replacement of missing teeth becoming better each year, practitioners are focusing their attention on the aesthetic aspects of implantology. However, improvement in aesthetics is only possible with the improvement in implant technology, surgical techniques and prosthodontic procedures. This study aimed at evaluating the effects of various physical and chemical agents on the implant surface; with the view of obtaining increased surface area and biocompatibility. The study found that the treatment of air-aluminum oxide blasted implants using a mixture of 30% HNO3-5% HF acids produced a surface which meets the consideration of aesthetics for implants placed in the anterior maxillary region.
    Matched MeSH terms: Surface Properties
  7. Lai YK, Fan RF
    J Cataract Refract Surg, 1996;22 Suppl 1:830-4.
    PMID: 9279680
    PURPOSE: To compare the efficacy of heparin-surface-modified (HSM), poly(methyl methacrylate) (PMMA) posterior chamber intraocular lenses (IOLs) with that of unmodified PMMA IOLs in reducing postoperative complications caused by inflammatory reactions after extracapsular cataract extraction in an Asian population.

    SETTING: Departments of Ophthalmology, University of Malaya, Kuala Lumpur, Malaysia, and Tan Tock Seng Hospital, Singapore.

    METHODS: In a randomized, double-blind study performed at two centers, 51 patients received an HSM PMMA lens and 48, an unmodified PMMA IOL. Cell and pigment deposits were evaluated by slitlamp at 1 to 6 days, 2 to 3 weeks, and 3 to 6 months postoperatively.

    RESULTS: Significantly more eyes with unmodified IOLs had inflammatory cell deposits than those with HSM IOLs at 3 to 6 months (P < .001) and 12 to 14 months (P = .018) postoperatively. The HSM group also had significantly fewer cell deposits per patient at these two follow-ups. Significantly more eyes in the non-HSM group had pigment deposits 3 to 6 months after surgery (P = .049). One year postoperatively, about 85% of patients in both groups had a best corrected visual acuity of 0.5 or better.

    CONCLUSION: Heparin surface modification significantly reduced the inflammatory response to PMMA IOLs in an Asian population for at least 12 to 14 months.

    Matched MeSH terms: Surface Properties
  8. Razak AA, Harrison A
    J Prosthet Dent, 1997 Apr;77(4):353-8.
    PMID: 9104710
    Dimensional accuracy of a composite inlay restoration is important to ensure an accurate fit and to minimize cementation stresses.
    Matched MeSH terms: Surface Properties
  9. Benjakul P, Cheunarrom C, Ongthiemsak C
    J Oral Sci, 2001 Mar;43(1):15-9.
    PMID: 11383631
    Stainless steel wrought wires used as clasp arms for removable partial dentures in Thailand were compared with those used in some other countries (in the as-received condition) in terms of flexibility, Vickers microhardness and composition. The results showed that there were significant differences (P< or =0.05) among the wires. A Japanese stainless steel wire (SK) was obviously different from the others. It had the lowest proportional limit and microhardness, but its flexibility was almost the same. The chemical composition of each wire was not greatly different. The wires were about 18-20 wt% chromium and 8-9 wt% nickel, except for the SK wire, which had about 12 wt% nickel.
    Matched MeSH terms: Surface Properties
  10. Boyle DK, Forsyth A, Bagg J, Stroubou K, Griffiths CE, Burke FJ
    J Dent, 2002 Jul-Aug;30(5-6):233-41.
    PMID: 12450714
    Glove wearing during patient treatment has been central to dental surgery infection control for over 15 years. However, little is known about the cutaneous effects of glove wearing on the hands of dental healthcare workers (DHCWs). The objective of this project was to assess the hand skin health of DHCWs before and after wearing gloves of two types and to compare this with a control group of non-DHCWs.
    Matched MeSH terms: Surface Properties
  11. Wong KK, Lee CK, Low KS, Haron MJ
    Chemosphere, 2003 Jan;50(1):23-8.
    PMID: 12656225
    A study on the modification of rice husk by various carboxylic acids showed that tartaric acid modified rice husk (TARH) had the highest binding capacities for Cu and Pb. The carboxyl groups on the surface of the modified rice husk were primarily responsible for the sorption of metal ions. A series of batch experiments using TARH as the sorbent for the removal of Cu and Pb showed that the sorption process was pH dependent, rapid and exothermic. The sorption process conformed to the Langmuir isotherm with maximum sorption capacities of 29 and 108 mg/g at 27 +/- 2 degrees C for Cu and Pb, respectively. The uptake increased with agitation rate. Decrease in sorbent particle size led to an increase in the sorption of metal ions and this could be explained by an increase in surface area and hence binding sites. Metal uptake was reduced in the presence of competitive cations and chelators. The affinity of TARH for Pb is greater than Cu.
    Matched MeSH terms: Surface Properties/drug effects
  12. Phang MY, Ng MH, Tan KK, Aminuddin BS, Ruszymah BH, Fauziah O
    Med J Malaysia, 2004 May;59 Suppl B:198-9.
    PMID: 15468886
    Tricalcium phosphate/hydroxyapatite (TCP/HA), hydroxyapatite (HA), chitosan and calcium sulphate (CaSO4) were studied and evaluated for possible bone tissue engineered construct acting as good support for osteogenic cells to proliferate, differentiate, and eventually spread and integrate into the scaffold. Surface morphology visualized by SEM showed that scaffold materials with additional fibrin had more cell densities attached than those without, depicting that the presence of fibrin and collagen fibers were truly a favourite choice of cells to attach. In comparison of various biomaterials used incorporated with fibrin, TCP/HA had the most cluster of cells attached.
    Matched MeSH terms: Surface Properties
  13. Hussain PB, Mohammad M
    Med J Malaysia, 2004 May;59 Suppl B:180-1.
    PMID: 15468877
    Failure analysis was performed to investigate the failure of the femur fixation plate which was previously fixed on the femur of a girl. Radiography, metallography, fractography and mechanical testing were conducted in this study. The results show that the failure was due to the formation of notches on the femur plate. These notches act as stress raisers from where the cracks start to propagate. Finally fracture occurred on the femur plate and subsequently, the plate failed.
    Matched MeSH terms: Surface Properties
  14. Al-Salihi KA, Samsudin AR
    Med J Malaysia, 2004 May;59 Suppl B:202-3.
    PMID: 15468888
    In this study the surface properties of two particulate coral and polyhydroxybutrate (PHB) were studied in order to characterize them prior to use in composite production. Coral powder and PHB particle were evaluated using scanning electron microscopy and confocal laser scanning microscopy, to measure surface porosity and pores size. The results showed that coral powder has multiple pleomorphic micropores cross each others give appearance of micro-interconnectivity. Some pore reached to 18 microm with an average porosity of 70%. PHB revealed multiple different size pores extended to the depth, with an average some times reach 25 microm and porosity 45%. These findings demonstrate that both coral and PHB have excellent pores size and porosity that facilitate bone in growth, vascular invasion and bone development. We believe that incorporation of coral powder into PHB will make an excellent composite scaffold for tissue engineering.
    Matched MeSH terms: Surface Properties
  15. Hassan MH
    Med J Malaysia, 2004 May;59 Suppl B:164-5.
    PMID: 15468869
    There has been, and is still, concern about the high elastic modulus of Ti alloys compared to bone. Any reduction in the Young's modulus value of the implant is expected to enhance stress redistribution to the adjacent bone tissues, minimize stress shielding and eventually prolong device lifetime. Dynamic Monte Carlo simulation is used to predict the gradual reduction in Young's modulus values between the bulk of Ti alloys and the modified surface layers due to Ca ion implantation. The simulation can be used as a screening step when applying new alloys and/or coatings.
    Matched MeSH terms: Surface Properties
  16. Kokubo T
    Med J Malaysia, 2004 May;59 Suppl B:91-2.
    PMID: 15468833
    Metallic materials implanted into bone defects are generally encapsulated by a fibrous tissue. Some metallic materials such as titanium and tantalum, however, have been revealed to bond to the living bone without forming the fibrous tissue, when they were subjected to NaOH solution and heat treatments. Thus treated metals form bone tissue around them even in muscle, when they take a porous form. This kind of osteoconductive and osteoinductive properties are attributed to sodium titanate or tantalate layer on their surfaces formed by the NaOH and heat treatments. These layers induce the deposition of bonelike apatite on the surface of the metals in the living body. This kind of bioactive metals are useful as bone substitutes even highly loaded portions, such as hip joint, spine and tooth root.
    Matched MeSH terms: Surface Properties
  17. Idris B, Rusnah M, Reusmaazran YM, Rohaida CH
    Med J Malaysia, 2004 May;59 Suppl B:67-8.
    PMID: 15468822
    Matched MeSH terms: Surface Properties
  18. Doreya MI, Mona EW, Afaf ES, Hanan HB
    Med J Malaysia, 2004 May;59 Suppl B:21-2.
    PMID: 15468799
    The standard bioglass composition GS45 as well as with excess silica GS50 or with the addition of 5% titanium oxide GS45+Ti5, were prepared by the polymeric route. The different glass components were added to the formed polymer. Firing at 700 degrees C gave an amorphous product with microporous texture that readily crystallizes out at 900 degrees C. The prepared materials were highly porous with two modes of pore system micro-pores and macro-pores with a size ranging between 100 microm to 0.006 microm and a porosity reaching 73%. The measured bulk density was between 0.36 to 1.1g/cm3. The fired material preserved the former structure of the polymer precursor. Biocompatibility was verified in vitro and vivo. IR of the specimens previously immersed in SBF revealed the formation of apatite like layer. While the histology sections of implants in rate femurs showed new bone tissue or bone trabeculae after 21 days.
    Matched MeSH terms: Surface Properties
  19. Konduk BA, Ucisik AH
    Med J Malaysia, 2004 May;59 Suppl B:53-4.
    PMID: 15468815
    The effect of hemodialysis on the mechanical behavior of a cellulosic Hemophane ME-IOH and one Polysulfone type hollow fibers was investigated. Mechanical tests showed that the deformation of polysulfone type of hollow fibers is entirely different than that of the other dialyser for the samples used and unused in hemodialysis. All the samples exposed to the dialysis showed decreased in ductility. Fracture surface studies proved that there was some alignment on the fracture surface. XRD and DSC experiments revealed structural changes had occurred.
    Matched MeSH terms: Surface Properties
  20. Raouf AA, Samudin AR, Samian R, Akool K, Abdullah N
    Med J Malaysia, 2004 May;59 Suppl B:49-50.
    PMID: 15468813
    This study was designed to investigate the surface properties especially surface porosity of polyhydroxybutyrate (PHB) using scanning electron microscopy. PHB granules were sprinkled on the double-sided sticky tape attached on a SEM aluminium stub and sputtered with gold(10nm thickness) in a Polaron SC515 Coater, following which the samples were placed into the SEM specimen chamber for viewing and recording. Scanning electron micrographs with different magnification of PHB surface revealed multiple pores with different sizes.
    Matched MeSH terms: Surface Properties
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links