Displaying publications 1 - 20 of 300 in total

Abstract:
Sort:
  1. Sulong MZ, Setchell DJ
    J Prosthet Dent, 1991 Dec;66(6):743-7.
    PMID: 1805022
    Adhesive bond strength studies for the tray adhesive of an addition vinyl polysiloxane (President) impression material were conducted with an acrylic resin, chromium-plated brass, and plastic trays. Tensile and shear stress studies were performed on the Instron Universal testing machine. Acrylic resin specimens roughened with 80-grit silicon carbide paper exhibited appreciably higher bond strengths compared with different types of tray material and methods of surface preparation.
    Matched MeSH terms: Tensile Strength
  2. Ibrahim WM, McCabe JF
    J Nihon Univ Sch Dent, 1993 Dec;35(4):225-9.
    PMID: 8158281
    The mean strength that has traditionally been taken as a measurement of the strength of a material does not reflect the true strength, and therefore it cannot be used as a design parameter. This explains why many brittle materials fail at unpredictable stress, either below or above the mean strength. By using Weibull statistics, the prediction and assessment of strength can be made more sensibly. The performance of a material can be predicted by considering a stress at a lower level of failure probability.
    Matched MeSH terms: Tensile Strength
  3. Lim KO, Cheong KC
    Med Eng Phys, 1994 Nov;16(6):526-30.
    PMID: 7858787
    In the fabrication of a bioprosthetic heart valve from bovine pericardial tissues, the tissues are subjected to suturing. The stress-strain response of sutured as well as unsutured strips of this tissue were examined. The stress-strain response was determined using a tensile-testing machine. It was found that suturing weakens the tissue in that sutured strips are more extensible, exhibit a lower stress at rupture and a lower final elastic modulus. In addition, it was also found that the bigger the suture/needle size used the greater the decrease in tissue strength. In all, tissue strength was observed to decrease by 22 to 59% in this study. The weakening of the tissue is attributed to the puncture holes created by the surgeon's needle which create regions of weakness. This response of bovine pericardial tissue to suturing should be given due consideration in the fabrication of a bioprosthetic heart valve using this tissue.
    Matched MeSH terms: Tensile Strength
  4. Wan Abas WA
    Biomed Mater Eng, 1994;4(7):473-86.
    PMID: 7881331
    The response of human skin to biaxial stretch tests in vivo was investigated and compared to the response to uniaxial tension. The results obtained illustrate the nonlinear, anisotropic, and viscoelastic (time-dependent) properties of skin under biaxial stretch. Preconditioning in the load-extension response was found not to be prominent. The results also suggest that the response of skin to a biaxial stretch in vivo is qualitatively similar to that in vitro. Values of the terminal stiffness and limit strain of skin under a biaxial stretch are found.
    Matched MeSH terms: Tensile Strength
  5. Wan Abas WA, Asseli MR
    Biomed Mater Eng, 1994;4(7):463-71.
    PMID: 7881330
    Local strains acting across an area of skin loaded uniaxially in vivo are converted to stresses using the standard elastic formulae. The stress values are compared to those obtained using the classical Bossinesq and Michell stress functions. The results indicate that these functions are capable of describing the response of the skin, both in the low load and the high load regions.
    Matched MeSH terms: Tensile Strength
  6. Wan Abas WA
    Biomed Mater Eng, 1995;5(2):59-63.
    PMID: 7655319
    The response of human skin to "stress relaxation" tests at low loads in vitro was investigated. A number of behaviours, other than those already well established and documented, were observed. The significant behaviours are pure recovery and relaxation-recovery. Other behaviours observed are temporary stress recovery during the relaxation process, and momentary sudden non-linear drop in stress value followed by a second relaxation. The pure recovery and relaxation-recovery responses are repeatable. The latter represents the transitional response between the well-known behaviour of stress relaxation and the behaviour of stress recovery.
    Matched MeSH terms: Tensile Strength
  7. Billa N, Yuen KH, Peh KK
    Drug Dev Ind Pharm, 1998 Jan;24(1):45-50.
    PMID: 15605596
    Ethyl acrylate-methyl methacrylate copolymer (Eudragit NE40D) was evaluated as matrix material for preparing controlled-release tablets of diclofenac sodium. Drug release could be modified in a predictable manner by varying the Eudragit NE40D content, but was pH dependent, being markedly reduced at lower pH. This could be attributed to the low solubility of the drug at these pH values. Thermal treatment of the tablets at 60 degrees C was also found to affect the rate of drug release, which was found to decrease with an increase in the treatment duration, but could be stabilized after 96 hr of treatment. This was also associated with a corresponding increase in the tablet tensile strength. However, treatment of the granules for 5 hr prior to compaction into tablets could shorten the stabilizing time of the drug release to 48 hr and that of the tensile strength to 24 hr. The effect of thermal treatment may be ascribed to better coalescence of the Eudragit particles to form a fine network, resulting in matrix of higher tortuosity and lower porosity.
    Matched MeSH terms: Tensile Strength
  8. Peh KK, Wong CF
    J Pharm Pharm Sci, 1999 May-Aug;2(2):53-61.
    PMID: 10952770
    To investigate the suitability of an SCMC (sodium carboxymethyl cellulose/polyethylene glycol 400/carbopol 934P) and an HPMC (hydroxypropylmethyl cellulose/polyethylene glycol 400/carbopol 934P) films as drug vehicle for buccal delivery.
    Matched MeSH terms: Tensile Strength
  9. Baie SH, Sheikh KA
    J Ethnopharmacol, 2000 Jul;71(1-2):93-100.
    PMID: 10904151
    Channa striatus, a fresh water snakehead fish, is reported to enhance dermal wound healing. Biochemical components such as amino acids and fatty acids are important for the synthesis of collagen fibers during wound healing. Arachidonic acid, a precursor of prostaglandin plays a vital role in healing the wounds. Haruan (C. striatus) contains all the essential amino acids for wound healing particularly glycine as well as high contents of arachidonic acid and polyunsaturated fatty acids that can promote prostaglandin synthesis. In the present work we have studied the wound healing effect of C. striatus in Sprague-Dawley rats. Cream formulations having different haruan fish extract concentrations as the active ingredient were prepared and stabilized, and they were applied to the wounds. The healing of wounds was characterized by an increase in the tensile strength of the skin, determined on the 7th post-operative day in each case. Haruan treatment of wounds promotes remodeling of collagen, by the synthesis of inter- and intra-molecular protein crosslinking and thus produces a marked increase (P<0.05) in tensile strength as compared to the cetrimide treated group. On the basis of our experiment we conclude that C. striatus helps in wound healing as indicated by the increase in tensile strength. We hypothesise that this effect may be due to its high content of arachidonic acid, glycine and polyunsaturated fatty acids. The mechanism of wound healing will be investigated in future studies.
    Matched MeSH terms: Tensile Strength
  10. Mohamed SH, Arifin A, Mohd Ishak ZA, Nizam A, Samsudin AR
    Med J Malaysia, 2004 May;59 Suppl B:147-8.
    PMID: 15468861
    The aim of this study was to evaluate the mechanical properties and glass transition temperature (Tg) of a denture base material prepared from high molecular weight poly methyl methacrylate (PMMA) and alumina (Al2O3). The glass transition temperature was studied by using differential scanning calorimetry (DSC). The effect of powder-to-liquid ratio was investigated. The result showed that the tensile properties and the Tg were slightly effected by the powder-to-liquid ratio. The ratio of 2.2:1 by weight of powder to liquid was found to be the best ratio for mixing the material to give the best result in this formulation.
    Matched MeSH terms: Tensile Strength
  11. Nizam A, Mohamed SH, Arifin A, Mohd Ishak ZA, Samsudin AR
    Med J Malaysia, 2004 May;59 Suppl B:145-6.
    PMID: 15468860
    The aim of this study was to evaluate the tensile properties and water absorption of denture base material prepared from high molecular weight poly methyl methacrylate (PMMA) and alumina (Al2O3) as particulate filler. Specimens for mechanical testing were prepared by adding composite powder to the monomer followed by hand mixing as in dental laboratory procedure. The tensile strength of the prepared denture base material was slightly higher than commercial denture base material, while the water absorption was almost the same for all formulation of denture base materials.
    Matched MeSH terms: Tensile Strength
  12. Hafeez YM, Zuki AB, Loqman MY, Yusof N, Asnah H, Noordin MM
    Med J Malaysia, 2004 May;59 Suppl B:117-8.
    PMID: 15468846
    The aim of this study was to evaluate bovine pericardium surgical patch in rat model. Bovine pericardial sacs collected from local abattoir were cleaned, disinfected and cut into pieces of 3 by 2.5cm and preserved in 99.5% glycerol. Full thickness abdominal wall defects of 3 by 2.5 cm were created in 30 adult male Sprague Dawley rats and repaired with glycerol preserved pieces. The rats were serially sacrificed in a group of six rats at 1,3,6,9 and 18 weeks post-surgical intervals for morphological and tensometeric study. Macroscopically, no mortality or postoperative surgical complications was encountered except slight adhesions between implanted grafts and some visceral organs in 10% of the rats. Microscopically no calcification or foreign body giant cell formation was found in the explanted grafts. The implanted grafts were replaced gradually with recipient tissue, which made mainly of dense collagenous bundles. The healing strength between the implanted grafts and the recipient abdominal wall was gradually increased with time. The results of this study showed that glycerol preserved bovine pericardium act as scaffold for transformation into living tissue without clinical complications such as that associated with prostheses.
    Matched MeSH terms: Tensile Strength
  13. Ismarul IN, Ishak Y, Ismail Z, Mohd Shalihuddin WM
    Med J Malaysia, 2004 May;59 Suppl B:57-8.
    PMID: 15468817
    Various proportions of chitosan/collagen films (70/30% to 95/05%) w/w were prepared and evaluated for its suitability as skin regenerating scaffold. Interactions between chitosan and collagen were studied using Fourier Transform Infrared spectroscopy (FTIR) and Differential Scanning Colorimetry (DSC). Scanning Electron Microscope (SEM) was used to investigate the morphology of the blend. Mechanical properties were evaluated using a Universal Testing Machine (UTM). The chitosan/collagen films were found to swell proportionally with time until it reaches equilibrium. FTIR spectroscopy indicated no chemical interaction between the components of the blends. DSC data indicated only one peak proving that these two materials are compatible at all proportions investigated. SEM micrographs also indicated good homogeneity between these two materials.
    Matched MeSH terms: Tensile Strength
  14. Mohamed SH, Arifin A, Mohd Ishak ZA, Nizam A, Samsudin AR
    Med J Malaysia, 2004 May;59 Suppl B:25-6.
    PMID: 15468801
    The aim of this study was to evaluate the effect of powder-to-liquid ratio on the glass transition temperature (Tg) and the tensile properties of denture base material prepared from poly (methyl methacrylate) (PMMA) and hydroxyapatite (HA) previously treated with 3-trimethoxysilylpropyl methacrylate (gamma-MPS). Specimens for mechanical testing were prepared by adding composites powder (PMMA, BPO and HA) to the monomer (MMA and EGDMA) followed by hand mixing as in dental laboratory description usage. The glass transition temperature was studied by using differential scanning calorimetry (DSC). It was observed that the tensile properties and the Tg were affected by the powder-to-liquid ratio. The mechanical characterization of the materials were performed by using single edge notch-tension (SEN-T) specimens; the fracture toughness was slightly higher in formulation which contained HA filler compared to commercial denture base material.
    Matched MeSH terms: Tensile Strength
  15. Ishak Ahmad, Mohd Khairil Saat, Ibrahim Abdullah, Azizah Baharum
    Blends of fibre-reinforced rubber based on natural rubber-thermoplastic (NR/LLDPE) reinforced by aramid fibre have been done using melt blending process. Two different processing methods were used; internal mixer and extrusion compounding in twin screw extruder. Twaron loading in the system was varied from 0 to 30%. It was found that increasing the amount of aramid fibre led to an increase in the tensile strength, tensile modulus and hardness of the composites while the strain decreased rapidly. The results showed that the optimum composition of filler loading in NR/LLDPE blend is 20%. The ,echanical behaviour was caused by the strong Twaron-matrices interaction in the composites and effective stress concentrating function of Twaron. Composites prepared using the twin-screw extruder have a higher tensile strength and tensile using the twin-screw extruder have a higher tensile stength and tensile modulus but lower impact strength compared to those prepared using internal mixer. Study of the fracture surface by scanning electron microscopy showed that the composite prepared using the internal mixer produced random fiber orientation while the twin-screw extruder produced the fibers aligned to the longitudinal direction. The results indicate that the mechanical properties of the composite were significantly influenced by the processing technique.
    Penyediaan komposit getah asli termoplastik daripada NR/LLDPE yang diperkuat gentian Twaron telah dijalankan melalui proses adunan leburan. Dua kaedah penyediaan yang berbeza digunakan iaitu menggunakan mesin pencampur dalaman manakala kaedah kedua menggunakan pengekstrud skru kembar. Kandungan Twaron di dalam komposit telah diubah daripada 0 hingga 30%. Keputusan menunjukkan bahawa penambahan Twaron telah meningkatkan nilai tegasan maksima, modulus Young dan kekuatan hentaman komposit tetapi menurunkan nilai terikan maksima. Kandungan Twaron yang optimum adalah 20%. Kehadiran Twaron telah membentuk satu jaringan saling tindak gentian-matriks menyebabkan kekuatan regangan komposit meningkat. Twaron juga berfungsi sebagai penyerap hentaman yang berkesan. Penyediaan komposit menggunakan pengekstrud skru berkembar telah menghasilkan nilai kekuatan regangan yang lebih tinggi berbanding penggunaan pencampur dalaman sebaliknya kekuatan hentaman yang lebih rendah. Kajian morfologi menggunakan mikroskop imbasan elektron mendapati komposit yang disediakan menggunakan pencampur dalaman menghasilkan gentian dengan orientasi rawak manakala pengekstrud skru kembar menghasilkan orientasi gentian yang selari. Keputusan ini menunjukkan bahawa sifat mekanik komposit NR/LLDPE yang diperkuat Twaron sangat dipengaruhi oleh teknik pemprosesan.
    Matched MeSH terms: Tensile Strength
  16. Amin MC, Fell JT
    Drug Dev Ind Pharm, 2004;30(9):937-45.
    PMID: 15554218
    Percolation theory has been used with great interest in understanding the design and characterization of dosage forms. In this study, work has been carried out to investigate the behavior of binary mixture tablets containing excipients of similar and different deformation properties. The binary mixture tablets were prepared by direct compression using lactose, polyvinyl chloride (PVC), Eudragit RS 100, and microcrystalline cellulose (MCC). The application of percolation theory on the relationships between compactibility, Pmax, or compression susceptibility (compressibility), gamma, and mixture compositions reveals the presence of percolation thresholds even for mixtures of similar deformation properties. The results showed that all mixture compositions exhibited at least one discreet change in the slope, which was referred to as the percolation threshold. The PVC/Eudragit RS100 mixture compositions showed significant percolation threshold at 80% (w/w) PVC loading. Two percolation thresholds were observed from a series of binary mixtures containing similar plastic deformation materials (PVC/MCC). The percolation thresholds were determined at 20% (w/w) and 80% (w/w) PVC loading. These are areas where one of the components percolates throughout the system and the properties of the tablets are expected to experience a sudden change. Experimental results, however, showed that total disruption of the tablet physical properties at the specified percolation thresholds can be observed for PVC/lactose mixtures at 20-30% (w/w) loading while only minor changes in the tablets' strength for PVC/MCC or PVC/Eudragit RS 100 mixtures were observed.
    Matched MeSH terms: Tensile Strength
  17. Bhaskar HN, Udupa SL, Udupa AL
    Indian J Exp Biol, 2005 Mar;43(3):294-6.
    PMID: 15816421
    Effect of two calcium channel blockers (CCBs) nifedipine and amlodipine, was studied on normal and steroid depressed wound healing in albino rats, using the dead space wound model. The drugs enhanced normal healing as evidenced by increase in tensile strength of 10 days old granulation tissue. There was neither a significant change in the hydroxyproline level (or collagen) nor a change in the glycosaminoglycan content in granulation tissue. However, lysyloxidase level was increased significantly. The increase in tensile strength could thus be attributed to better cross-linking and maturation of collagen rather than collagen synthesis per se. The drugs were also able to overcome steroid depressed wound healing. It is likely that the prohealing effects may be related to the improved antioxidant status too, since superoxide dismutase levels were observed to be higher in the CCB- treated animals.
    Matched MeSH terms: Tensile Strength
  18. Agamuthu P, Faizura PN
    Waste Manag Res, 2005 Apr;23(2):95-100.
    PMID: 15864950
    Plastic waste constitutes the third largest waste volume in Malaysian municipal solid waste (MSW), next to putrescible waste and paper. The plastic component in MSW from Kuala Lumpur averages 24% (by weight), whereas the national mean is about 15%. The 144 waste dumps in the country receive about 95% of the MSW, including plastic waste. The useful life of the landfills is fast diminishing as the plastic waste stays un-degraded for more than 50 years. In this study the compostability of polyethylene and pro-oxidant additive-based environmentally degradable plastics (EDP) was investigated. Linear low-density polyethylene (LLDPE) samples exposed hydrolytically or oxidatively at 60 degrees C showed that the abiotic degradation path was oxidative rather than hydrolytic. There was a weight loss of 8% and the plastic has been oxidized as shown by the additional carbonyl group exhibited in the Fourier transform infra red (FTIR) Spectrum. Oxidation rate seemed to be influenced by the amount of pro-oxidant additive, the chemical structure and morphology of the plastic samples, and the surface area. Composting studies during a 45-day experiment showed that the percentage elongation (reduction) was 20% for McD samples [high-density polyethylene, (HDPE) with 3% additive] and LL samples (LLDPE with 7% additive) and 18% reduction for totally degradable plastic (TDP) samples (HDPE with 3% additive). Lastly, microbial experiments using Pseudomonas aeroginosa on carbon-free media with degradable plastic samples as the sole carbon source, showed confirmatory results. A positive bacterial growth and a weight loss of 2.2% for degraded polyethylene samples were evident to show that the degradable plastic is biodegradable.
    Matched MeSH terms: Tensile Strength
  19. Saringat HB, Alfadol KI, Khan GM
    Pak J Pharm Sci, 2005 Jul;18(3):25-38.
    PMID: 16380341
    Coating has been widely used in pharmaceutical manufacture either as non-functional or a functional entity. The objectives of the present study were to investigate the effect of plasticizers such as PEG400, PEG1000 and triacetin on mechanical properties, glass transition temperature and water vapor transmission of free films prepared from HPMC and/or HPMC:PVA blends, to develop suitable coating system for tablets, and to determine the release profiles of the coated tablets. The tensile strength of plasticized HPMC films was generally lower than that of control HPMC film and could be attributed to increased crystallinity and segmental chain mobility of HPMC. This effect increased as the concentration of plasticizer increased. Generally the addition of both grades of polyethylene glycol (PEG400 & PEG1000) increased the moisture permeability of HPMC films but the films containing triacetin provided a more rigid barrier to moisture compared to unplasticized HPMC films. The dissolution profiles of paracetamol tablets coated with 7% w/v HPMC coating-solutions containing PEG400, PEG1000 and triacetin, and those containing PEG400 & PVA together showed that HPMC had weak water resistance. The presence of PEG400 and 1000 in HPMC films further weakened its resistance to solubility while the presence of triacetin caused a little increase in HPMC water resistance. From the results it was concluded that HPMC at 7%w/w concentration was suitable for film-coating intended for non-functional coating. Presence of the PEG 400, PEG1000 and triacetin as well as the presence of PVA and PEG400 together improved the coating properties of HPMC films and made it more suitable as a non-functional coating material.
    Matched MeSH terms: Tensile Strength
  20. Mohd Fuad D, Masbah O, Shahril Y, Jamari S, Norhamdan MY, Sahrim SH
    Med J Malaysia, 2006 Feb;61 Suppl A:27-9.
    PMID: 17042225
    Antibiotic-loaded bone cement has been used as prophylaxis against infection in total joint replacement surgery. Its effect on the mechanical strength of cement is a major concern as high dose of antibiotic was associated with a significant reduction in mechanical strength of bone cement. However, the cut-off antibiotic that weakens the mechanical strength of cement remains to be determined. This study was undertaken to observe the changes in the mechanical properties of bone cement with gradual increments of Cefuroxime antibiotic. Cefuroxime at different doses: 0, 1.5, 3.0 and 4.5gm were added to a packet of 40gm bone cement (Simplex P) and study samples were prepared by using third generation cementing technique. Mechanical impact, flexural and tensile strength were tested on each sample. Significant impact and tensile strength reduction were observed after addition of 4.5 gm of Cefuroxime. However, flexural strength was significantly reduced at a lower dose of 3.0 gm. The maximum dose of Cefuroxime to be safely added to 40mg Surgical Simplex P is 1.5gm when third generation cementing technique is used. Further study is needed to determine whether it is an effective dose as regards to microbiological parameters.
    Matched MeSH terms: Tensile Strength*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links