Displaying publications 1 - 20 of 120 in total

Abstract:
Sort:
  1. Al-Adsani A, Dahniya MH, Al-Adsani N
    Postgrad Med J, 2001 Feb;77(904):127, 137-8.
    PMID: 11161092
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  2. Saw A, Sengupta S
    Injury, 2001 Jun;32(5):430-2.
    PMID: 11382432
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  3. Saffor A, bin Ramli AR, Ng KH
    Australas Phys Eng Sci Med, 2003 Jun;26(2):39-44.
    PMID: 12956184
    Wavelet-based image coding algorithms (lossy and lossless) use a fixed perfect reconstruction filter-bank built into the algorithm for coding and decoding of images. However, no systematic study has been performed to evaluate the coding performance of wavelet filters on medical images. We evaluated the best types of filters suitable for medical images in providing low bit rate and low computational complexity. In this study a variety of wavelet filters are used to compress and decompress computed tomography (CT) brain and abdomen images. We applied two-dimensional wavelet decomposition, quantization and reconstruction using several families of filter banks to a set of CT images. Discreet Wavelet Transform (DWT), which provides efficient framework of multi-resolution frequency was used. Compression was accomplished by applying threshold values to the wavelet coefficients. The statistical indices such as mean square error (MSE), maximum absolute error (MAE) and peak signal-to-noise ratio (PSNR) were used to quantify the effect of wavelet compression of selected images. The code was written using the wavelet and image processing toolbox of the MATLAB (version 6.1). This results show that no specific wavelet filter performs uniformly better than others except for the case of Daubechies and bi-orthogonal filters which are the best among all. MAE values achieved by these filters were 5 x 10(-14) to 12 x 10(-14) for both CT brain and abdomen images at different decomposition levels. This indicated that using these filters a very small error (approximately 7 x 10(-14)) can be achieved between original and the filtered image. The PSNR values obtained were higher for the brain than the abdomen images. For both the lossy and lossless compression, the 'most appropriate' wavelet filter should be chosen adaptively depending on the statistical properties of the image being coded to achieve higher compression ratio.
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  4. Abdullah A, Mahmud MR, Maimunah A, Zulfiqar MA, Saim L, Mazlan R
    Ann Acad Med Singap, 2003 Jul;32(4):442-5.
    PMID: 12968546
    INTRODUCTION: Accurate preoperative imaging of the temporal bone in patients receiving cochlear implants is important. High resolution computed tomography (HRCT) and magnetic resonance (MR) imaging are the 2 preoperative imaging modalities that provide critical information on abnormalities of the otic capsule, pneumatisation of the mastoid, middle ear abnormalities, cochlear ducts patency and presence of cochlear nerve.

    MATERIALS AND METHODS: The HRCT and MR imaging in 46 cochlear implant patients in our department were reviewed.

    RESULTS: Majority of our patients [34 patients (73.9%)] showed normal HRCT of the temporal bone; 5 (10.9%) patients had labyrinthitis ossificans, 2 (4.3%) had Mondini's abnormality and 2 (4.3%) had middle ear effusion. One patient each had high jugular bulb, hypoplasia of the internal auditory canal and single cochlear cavity, respectively.

    CONCLUSION: The above findings contribute significantly to our surgical decisions regarding candidacy for surgery, side selection and surgical technique in cochlear implantation.

    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  5. Leong CF, Cheong SK, Ng P, Amran AR
    Hosp Med, 2003 Nov;64(11):686-7.
    PMID: 14671884
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  6. Abdul Latip LS, Ahmad Alias NA, Ariff AR, Shuaib IL, Abdullah J, Naing NN
    J Clin Neurosci, 2004 Nov;11(8):835-9.
    PMID: 15519858 DOI: 10.1016/j.jocn.2003.12.017
    Minor head injury in a developing country like Malaysia is managed by primary care physicians and/or medical assistants in district hospitals. These patients are seen initially in their local hospitals, which have at least an X-ray machine for the purpose of screening. This study aimed to guide these physicians to manage these patients at a primary care level. A cross-sectional study was conducted and the study revealed significant predictors of significant computed tomographic (CT) findings. The presence of a Glasgow coma scale (GCS) score of 14 or 13 was associated with the risk of developing significant CT findings compared to patients with a GCS of 15 (p<0.001). Thirty-seven out of 50 patients with GCS of 14 or 13 developed clinically significant brain injury on CT scan. Similarly, the presence of skull fracture was associated with the risk of developing CT abnormalities (p<0.001). Forty-two out of 51 patients with skull fracture developed clinically significant CT findings. Vomiting was associated with developing CT abnormalities (p=0.017). Twenty-seven out of 40 patients with vomiting showed significant CT findings. Soft tissue injury was also found to be associated with developing CT abnormalities (p=0.007). Therefore, we propose reclassifying minor head injury based on the GCS score. Patients with a GCS score of 15 were classified as having mild head injury, while patients with a GCS score of 13 or 14 were at higher risk of developing brain injury and therefore categorized as high risk mild head injury. This group requires emergency CT scan examination, especially when associated with non-motor vehicle accidents, abnormal central nervous system (CNS) examination, craniofacial injuries or skull fractures. They should be referred to a general surgical unit which can treat head injuries or a neurosurgical tertiary centre.
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  7. Ranganathan S, Moosa F, Kamarulzaman A, Looi LM
    Br J Radiol, 2005 Apr;78(928):353-4.
    PMID: 15774599
    Cryptococcus neoformans is a yeast like fungus, which is commonly found in bird droppings, especially pigeons. Most cases of cryptococcal infections occur in immunocompromised patients or in those who are on long term immunosuppressant therapies. Cryptococcal infection usually presents as a meningoencephalitis or a pulmonary infection. Skin, bone and genital infections are very rare. We report the second case of vaginal cryptococcossis to be reported in English literature and the first to be imaged with CT and MRI.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  8. Yusof MI, Ming LK, Abdullah MS
    J Orthop Surg (Hong Kong), 2007 Aug;15(2):187-90.
    PMID: 17709859
    To measure the cervical pedicles and assess the feasibility of transpedicular fixation in a Malay population.
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  9. Zain JM, Fauzi AM, Aziz AA
    Conf Proc IEEE Eng Med Biol Soc, 2007 10 20;2006:5459-62.
    PMID: 17946306
    Digital watermarking medical images provides security to the images. The purpose of this study was to see whether digitally watermarked images changed clinical diagnoses when assessed by radiologists. We embedded 256 bits watermark to various medical images in the region of non-interest (RONI) and 480K bits in both region of interest (ROI) and RONI. Our results showed that watermarking medical images did not alter clinical diagnoses. In addition, there was no difference in image quality when visually assessed by the medical radiologists. We therefore concluded that digital watermarking medical images were safe in terms of preserving image quality for clinical purposes.
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  10. Sim KH, Ong TK, Chin SP, Wong M
    Indian Heart J, 2007 Mar-Apr;59(2 Suppl B):B25-32.
    PMID: 19153433
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  11. Annuar BR, Liew CK, Chin SP, Ong TK, Seyfarth MT, Chan WL, et al.
    Eur J Radiol, 2008 Jan;65(1):112-9.
    PMID: 17466480
    To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR).
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  12. Kasthoori JJ, Liam CK, Wastie ML
    Singapore Med J, 2008 Feb;49(2):e47-9.
    PMID: 18301826
    Non-tuberculous mycobacterial infection (NMI) occurs in elderly women with no pre-existing lung disease, and this has been termed the Lady Windermere syndrome. NMIs are increasing in prevalence and an increasing number of pulmonary mycobacterial infections is due to non-tuberculous mycobacteria. The diagnosis is often difficult because the organism is not readily isolated or cultured, and the condition may not be considered by the radiologist. We report NMI in a 64-year-old woman, based on clinical and radiological findings. Although termed the Lady Windermere syndrome, the name does not correspond to the character in Oscar Wilde's play; hence the eponym is not widely used.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  13. Chang LK, Liew NS, Soh HL, Tan SZ, Wong SH
    Med J Malaysia, 2008 Jun;63(2):131-6.
    PMID: 18942299 MyJurnal
    CT angiography (CTA) is a fast examination performed with a time-optimised contrast injection to enhance the cerebral arteries. Being a new imaging modality in our hospital, evaluation of the effectiveness of 64-row multislice CTA in detecting intracranial aneurysms in ruptured subarachnoid haemorrhage (SAH) cases is necessary. We conducted a descriptive prospective study by recruiting 30 consecutively operated SAH cases from May 2005 until November 2006. CTA findings were studied by radiologist and neurosurgeon and these were compared with operative findings. The sensitivity and specificity of CTA were 94.4% and 97.2% respectively. Approximately half of the patients were scanned within four hours and operated within 24 hours. In conclusion, CTA proves to be highly sensitive and specific in the diagnosis of intracranial aneurysms in our study.
    KEY WORDS: Subarachnoid haemorrhage, Intracranial aneurysm, Computed tomography (CT), CT angiography (CTA), Sarawak
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  14. Abdul Jalil N, Abdul Rahim N, Md Shalleh N, Rossetti C
    Singapore Med J, 2008 Jul;49(7):e178-82.
    PMID: 18695852
    A majority of the clinical use of positron emission tomography (PET)-computed tomography (CT) is related to cancer management. Its application in evaluating inflammatory diseases and pyrexia of unknown origin is becoming popular. We reviewed the fluorine-18-fluorodeoxyglucose PET-CT findings of an 80-year-old woman with nonspecific clinical presentation consisting of generalised malaise, moderately high fever and weight loss. Prior CT and magnetic resonance imaging were not helpful in providing a clinical diagnosis. The diagnosis was Horton's arteritis, and the patient responded well to high-dose steroids.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  15. Ramli N, Rahmat K, Tan GP
    Singapore Med J, 2008 Jul;49(7):e175-7.
    PMID: 18695851
    Malignant osteopetrosis is associated with petrous carotid canal and internal carotid artery stenosis in the skull base. We present a four-year-old boy with malignant osteopetrosis who developed right frontal lobe infarction as a result of bilateral internal carotid artery hypotrophy.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  16. Ghani AR, Abdullah JM, Ghazali M, Ahmad F, Ahmad KA, Madhavan M
    Singapore Med J, 2008 Jul;49(7):e192-4.
    PMID: 18695856
    Recurrent supratentorial extraventricular ependymoma in a four-year-old Malay boy treated twice surgically in combination with cranial radiotherapy is reported. He presented with symptoms of raised intracranial pressure and a history of focal seizure. Computed tomography of the brain showed a left supratentorial extraventricular cystic lesion causing a mass effect. The tumour histology was ependymoma (WHO grade II). The clinical course, radiological characteristics and management of this tumour are discussed. Molecular genetic analysis of p53 and p27 genes revealed substitution of nucleotide G to C at location nucleotide 12139, exon 4 of gene p53. No alteration was detected at exon 5-6 and 8 of p53 gene and exon 1 and 2 of p27 gene.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  17. Yaakup H, Sagap I, Fadilah SA
    Singapore Med J, 2008 Oct;49(10):e289-92.
    PMID: 18946602
    Primary oesophageal lymphoma is a very rare entity, with fewer than 30 reported cases worldwide. It represents an important cause of dysphagia. Most of the oesophageal lymphomas are diffuse large B-cell type, with only one reported case of anaplastic large cell lymphoma (ALCL) of T-cell phenotype. Primary oesophageal lymphomas that are not associated with an immunocompromised state tend to affect elderly patients. We describe the first case of primary oesophageal Ki (CD30)-positive ALK+ALCL of T-cell phenotype in a 34-year-old immunocompetent woman, who presented with a two-year history of dysphagia. She was treated with chemotherapy and endoscopic oesophageal dilations and stenting, resulting in complete remission of the lymphoma and resolution of the dysphagia. She then underwent autologous peripheral blood haematopoietic stem cell transplantation and remained disease-free two years after the diagnosis.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  18. Leong BD, Chuah JA, Kumar VM, Mazri MY, Zainal AA
    Singapore Med J, 2008 Nov;49(11):e300-2.
    PMID: 19037533
    True and pseudoaneurysms of the visceral arteries are uncommon. They represent 0.1-0.2 percent of all vascular aneurysms. Visceral artery aneurysms (VAAs) should be treated due to their propensity to rupture and associated high mortality. We describe a 58-year-old man with pseudoaneurysm of the inferior pancreaticoduodenal artery and who presented with post-motor vehicle accident abdominal pain and a pulsatile epigastic mass. Computed tomography (CT) showed a pseudoaneurysm of the visceral artery, and selective mesenteric angiography showed the aneurysm to be arising from the inferior pancreaticoduodenal artery. The aneurysm was successfully treated with endovascular coil embolisation. CT angiogram at one month post-procedure revealed persistent occlusion of the aneurysm. To the best of our knowledge, this is the first reported pseudoaneurysm of inferior pancreaticoduodenal artery secondary to blunt abdominal trauma from a motor vehicle accident and also the first reported VAA from Malaysia.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  19. Joshi SC, Pant I, Hamzah F, Kumar G, Shukla AN
    Indian J Cancer, 2008 12 30;45(4):137-41.
    PMID: 19112200
    Positron emission tomography (PET) has emerged as an important diagnostic tool in the management of lung cancers. Although PET is sensitive in detection of lung cancer, but FDG (2-deoxy-2- 18 fluro-D-glucose) is not tumor specific and may accumulate in a variety of nonmalignant conditions occasionally giving false positive result. Addition of CT to PET improves specificity foremost, but also sensitivity in tumor imaging. Thus, PET/CT fusion images are a more accurate test than either of its individual components and are probably also better than side-by-side viewing of images from both modalities. PET/CT fusion images are useful in differentiating between malignant and benign disease, fibrosis and recurrence, staging and in changing patient management to more appropriate therapy. With analysis and discussion it appears that PET/ CT fusion images have the potential to dramatically improve our ability to manage the patients with lung cancer and is contributing to our understanding of cancer cell biology and in development of new therapies.
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  20. Nordin AJ, Rossetti C, Rahim NA
    Eur. J. Nucl. Med. Mol. Imaging, 2009 May;36(5):882.
    PMID: 19296106 DOI: 10.1007/s00259-009-1107-z
    Matched MeSH terms: Tomography, X-Ray Computed/methods
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links