Displaying publications 1 - 20 of 104 in total

Abstract:
Sort:
  1. Agi A, Junin R, Alqatta AYM, Gbadamosi A, Yahya A, Abbas A
    Ultrason Sonochem, 2019 Mar;51:214-222.
    PMID: 30401623 DOI: 10.1016/j.ultsonch.2018.10.023
    Ultrafiltration has been proven to be very effective in the treatment of oil-in-water emulsions, since no chemical additives are required. However, ultrafiltration has its limitations, the main limits are concentration polarization resulting to permeate flux decline with time. Adsorption, accumulation of oil and particles on the membrane surface which causes fouling of the membrane. Studies have shown that the ultrasonic is effective in cleaning of fouled membrane and enhancing membrane filtration performance. But the effectiveness also, depends on the selection of appropriate membrane material, membrane geometry, ultrasonic module design, operational and processing condition. In this study, a hollow and flat-sheet polyurethane (PU) membranes synthesized with different additives and solvent were used and their performance evaluated with oil-in-water emulsion. The steady-state permeate flux and the rejection of oil in percentage (%) at two different modes were determined. A dry/wet spinning technique was used to fabricate the flat-sheet and hollow fibre membrane (HFMs) using Polyethersulfone (PES) polymer base, Polyvinylpyrrolidone (PVP) additive and N, N-Dimethylacetamide (DMAc) solvent. Ultrasonic assisted cross-flow ultrafiltration module was built to avoid loss of ultrasonic to the surrounding. The polyurethane (PU) was synthesized by polymerization and sulphonation to have an anionic group (-OH; -COOH; and -SO3H) on the membrane surface. Changes in morphological properties of the membrane had a significant effect on the permeate flow rate and oil removal. Generation of cavitation and Brownian motion by the ultrasonic were the dominant mechanisms responsible for ultrafiltration by cracking the cake layers and reducing concentration polarization at the membrane surface. The percentage of oil after ultrafiltration process with ultrasonic is about 90% compared to 49% without ultrasonic. Ultrasonic is effective in enhancing the membrane permeate flux and controlling membrane fouling.
    Matched MeSH terms: Ultrasonics
  2. Alhawari ARH, Majeed SF, Saeidi T, Mumtaz S, Alghamdi H, Hindi AT, et al.
    Micromachines (Basel), 2021 Apr 07;12(4).
    PMID: 33917167 DOI: 10.3390/mi12040411
    The increasing needs of free licensed frequency bands like Industrial, Scientific, and Medical (ISM), Wireless Local Area Network (WLAN), and 5G for underwater communications required more bandwidth (BW) with higher data transferring rate. Microwaves produce a higher transferring rate of data, and their associated devices are smaller in comparison with sonar and ultrasonic. Thus, transceivers should have broad BW to cover more of a frequency band, especially from ultra-wideband (UWB) systems, which show potential outcomes. However, previous designs of similar work for underwater communications were very complicated, uneasy to fabricate, and large. Therefore, to overcome these shortcomings, a novel compact elliptical UWB antenna is designed to resonate from 1.3 to 7.2 GHz. It is invented from a polytetrafluoroethylene (PTFE) layer with a dielectric constant of 2.55 mm and a thickness of 0.8 mm. The proposed antenna shows higher gain and radiation efficiency and stability throughout the working band when compared to recent similarly reported designs, even at a smaller size. The characteristics of the functioning antenna are investigated through fluid mediums of fresh-water, seawater, distilled water, and Debye model water. Later, its channel capacity, bit rate error, and data rate are evaluated. The results demonstrated that the antenna offers compact, easier fabrication with better UWB characteristics for underwater 5G communications.
    Matched MeSH terms: Ultrasonics
  3. Goh T, Abdul Rahim Samsudin, Abdul Ghani Rafek
    A geotechnical study needs to be carried out to determine the engineering parameters of the rock mass at the project site in executing construction projects such as tunnels, dams, highways and buildings. Design and safety factor of the construction are highly dependent on soil and rock engineering parameters which are usually determined by in-situ test such as Standard Penetration Test (SPT) and seismic tests. The SPT test which normally involves drilling and laboratory works always incur high operating cost, while seismic tests on the other hand are fast, cheap, non-destructive and an easy to operate method for rock mass characterization. The spectral analysis of surface waves (SASW) method is an in situ and non-destructive measurement that is rapid and cost effective. The aims of this study were to determine Rock Quality Designation (RQD) value, excavation classification analysis as well as site characterization by using the SASW method. WinSASW 3.1.3 was used for inversion processing of the SASW data to produce shear wave velocity (Vs) versus depth profiles. The profiles were then analyzed and correlated with rock mass engineering geological parameters such as RQD and site characterization as well as excavation classification of rock mass. Twenty (20) SASW tests were conducted on the granitic rock mass and four (4) SASW tests were conducted on a cut hill slope of metasedimentary rocks. RQD values were computed based on shear wave velocities and ultrasonic velocities of intact (fresh) rock. The differences between RQD obtained from SASW method and those from discontinuity survey were found to be less than 10%. Excavation classification for granitic rock mass at JKR Quarry was empirically determined using both SASW and ultrasonic velocities as well as RQD value of the rock mass. Site characterization for metasedimentary rocks mass at Bukit Tampoi was determined based on shear wave velocities from SASW method.
    Matched MeSH terms: Ultrasonics
  4. Suhaimi SH, Hasham R, Hafiz Idris MK, Ismail HF, Mohd Ariffin NH, Abdul Majid FA
    Molecules, 2019 Nov 18;24(22).
    PMID: 31752230 DOI: 10.3390/molecules24224183
    Primarily, optimization of ultrasonic-assisted extraction (UAE) conditions of Orthospihon stamineus was evaluated and verified using a central composite design (CCD) based on three factors including extraction time (minutes), ultrasound amplitude (A), and solvent concentration (%). The response surface methodology (RSM) was performed to develop an extraction method with maximum yield and high rosmarinic acid content. The optimal UAE conditions were as follows: extraction time 21 min, ultrasound amplitudes 62 A, and solvent composition 70% ethanol in water. The crude extract was further fractionated using solid-phase extraction (SPE), where six sequential fractions that varied in polarity (0-100% Acetonitrile in water) were obtained. Next, the six fractions were evaluated for their antioxidant and anti-cancer properties. This study found that Fraction 2 (F2) contained the highest rosmarinic acid content and showed the strongest antioxidant activity. Additionally, F2 showed an anti-proliferative effect against prostate cancer (DU145) with no harmful effect on normal cells.
    Matched MeSH terms: Ultrasonics
  5. Noroozi M, Zakaria A, Radiman S, Abdul Wahab Z
    PLoS One, 2016;11(4):e0152699.
    PMID: 27064575 DOI: 10.1371/journal.pone.0152699
    In this paper, we report how few layers graphene that can be produced in large quantity with low defect ratio from exfoliation of graphite by using a high intensity probe sonication in water containing liquid hand soap and PVP. It was founded that the graphene powder obtained by this simple exfoliation method after the heat treatment had an excellent exfoliation into a single or layered graphene sheets. The UV-visible spectroscopy, FESEM, TEM, X-ray powder diffraction and Raman spectroscopy was used to analyse the graphene product. The thermal diffusivity of the samples was analysed using a highly accurate thermal-wave cavity photothermal technique. The data obtained showed excellent enhancement in the thermal diffusivity of the graphene dispersion. This well-dispersed graphene was then used to fabricate an electrically conductive polymer-graphene film composite. The results demonstrated that this low cost and environmental friendly technique allowed to the production of high quality layered graphene sheets, improved the thermal and electrical properties. This may find use in the wide range of applications based on graphene.
    Matched MeSH terms: Ultrasonics/methods*
  6. Karami N, Mohammadi P, Zinatizadeh A, Falahi F, Aghamohammadi N
    Ultrason Sonochem, 2018 Sep;46:89-98.
    PMID: 29739516 DOI: 10.1016/j.ultsonch.2018.04.009
    The biomass concentration of conventional activated sludge (CAS) process due to low sludge sedimentation in clarifiers is limited to 3000 mg/L. In this study, high-frequency ultrasound wave (1.8 MHz) was applied to enhance the CAS process performance using high Mixed Liquor Suspended Solid (MLSS) concentration. The study conducted using a pilot scale CAS bioreactor (with and without ultrasound) and their performance for treating a hospital wastewater were compared. Experimental conditions were designed based on a Central Composite Design (CCD). The sets of data analyzed, modeled and optimized using Response Surface Methodology (RSM). The effect of MLSS concentration 3000-8000 mg/L and hydraulic retention time (HRT) 2-8 h are considered as operating variables to investigate on process responses. The obtained results showed that high-frequency ultrasound was significantly decreased the sludge volume index (SVI) 50% and effluent turbidity about 88.5% at high MLSS. Also, observed that COD removal of both systems was nearly similar, as the maximum COD removal for sonicated and non-sonicated systems were 92 and 92.5% respectively. However, this study demonstrates that the ultrasound irradiation has not had any negative effect on the microbial activity.
    Matched MeSH terms: Ultrasonics/methods*
  7. Chen RS, Mohd Ruf MFH, Shahdan D, Ahmad S
    PLoS One, 2019;14(9):e0222662.
    PMID: 31545820 DOI: 10.1371/journal.pone.0222662
    Thermoplastic natural rubber (TPNR) was compounded with graphene nanoplatelets (GNP) via ultrasonication and melt blending. The effects of ultrasonication period (1-4 hours) and GNP weight fraction (0.5, 1.0, 1.5 and 2.0 wt.%) on the mechanical, thermal and conductivity properties were investigated. Results showed that the 3 hours of ultrasonic treatment on LNR/GNP gave the greatest improvement in tensile strength of 25.8% (TPNR/GNP nanocomposites) as compared to those without ultrasonication. The TPNR nanocomposites containing 1.5 wt.% GNP exhibited the highest strength (16 MPa for tensile, 14 MPa for flexural and 11 kJm-2 for impact) and modulus (556 MPa and 869 MPa for tensile and flexural, respectively). The incorporation of GNP had enhanced the thermal stability. It can be concluded that the GNP had imparted the thermally and electrically conductive nature to the TPNR blend.
    Matched MeSH terms: Ultrasonics
  8. Das A, Barua A, Mohimin MA, Abedin J, Khandaker MU, Al-Mugren KS
    Healthcare (Basel), 2021 Apr 10;9(4).
    PMID: 33920290 DOI: 10.3390/healthcare9040445
    BACKGROUND: The use of a touchless automated hand sanitizer dispenser may play a key role to reduce contagious diseases. The key problem of the conventional ultrasonic and infra-red-based dispensers is their malfunctioning due to the interference of sunlight, vehicle sound, etc. when deployed in busy public places. To overcome such limitations, this study introduced a laser-based sensing device to dispense sanitizer in an automated touchless process.

    METHOD: The dispensing system is based on an Arduino circuit breadboard where an ATmega328p microcontroller was pre-installed. To sense the proximity, a light-dependent resistor (LDR) is used where the laser light is to be blocked after the placement of human hands, hence produced a sharp decrease in the LDR sensor value. Once the LDR sensor value exceeds the lower threshold, the pump is actuated by the microcontroller, and the sanitizer dispenses through the nozzle.

    RESULTS AND DISCUSSION: A novel design and subsequent fabrication of a low-cost, touchless, automated sanitizer dispenser to be used in public places, was demonstrated. The overall performance of the manufactured device was analyzed based on the cost and power consumption, and environmental factors by deploying it in busy public places as well as in indoor environment in major cities in Bangladesh, and found to be more efficient and cost-effective compared to other dispensers available in the market. A comprehensive discussion on this unique design compared to the conventional ultrasonic and infra-red based dispensers, is presented to show its suitability over the commercial ones. The guidelines of the World Health Organization are followed for the preparation of sanitizer liquid. A clear demonstration of the circuitry connections is presented herein, which facilitates the interested individual to manufacture a cost-effective dispenser device in a relatively short time and use it accordingly. Conclusion: This study reveals that the LDR-based automated hand sanitizer dispenser system is a novel concept, and it is cost-effective compared to the conventional ones. The presented device is expected to play a key role in contactless hand disinfection in public places, and reduce the spread of infectious diseases in society.

    Matched MeSH terms: Ultrasonics
  9. Abd Razak NA, Abu Osman NA, Gholizadeh H, Ali S
    Biomed Eng Online, 2014 Apr 23;13:49.
    PMID: 24755242 DOI: 10.1186/1475-925X-13-49
    BACKGROUND: The design and performance of a new development prosthesis system known as biomechatronics wrist prosthesis is presented in this paper. The prosthesis system was implemented by replacing the Bowden tension cable of body powered prosthesis system using two ultrasonic sensors, two servo motors and microcontroller inside the prosthesis hand for transradial user.

    METHODS: The system components and hand prototypes involve the anthropometry, CAD design and prototyping, biomechatronics engineering together with the prosthetics. The modeler construction of the system develop allows the ultrasonic sensors that are placed on the shoulder to generate the wrist movement of the prosthesis. The kinematics of wrist movement, which are the pronation/supination and flexion/extension were tested using the motion analysis and general motion of human hand were compared. The study also evaluated the require degree of detection for the input of the ultrasonic sensor to generate the wrist movements.

    RESULTS: The values collected by the vicon motion analysis for biomechatronics prosthesis system were reliable to do the common tasks in daily life. The degree of the head needed to bend to give the full input wave was about 45°-55° of rotation or about 14 cm-16 cm. The biomechatronics wrist prosthesis gave higher degree of rotation to do the daily tasks but did not achieve the maximum degree of rotation.

    CONCLUSION: The new development of using sensor and actuator in generating the wrist movements will be interesting for used list in medicine, robotics technology, rehabilitations, prosthetics and orthotics.

    Matched MeSH terms: Ultrasonics/instrumentation*
  10. Mat-Shayuti MS, Tuan Ya TMYS, Abdullah MZ, Othman NH, Alias NH
    Environ Sci Pollut Res Int, 2021 Nov;28(41):58081-58091.
    PMID: 34106401 DOI: 10.1007/s11356-021-14776-8
    Despite the potential shown by previous investigations on the use of ultrasound for the remediation of oil-contaminated sand, the influence and interactions among ultrasonic parameters and oily sand are unclear, leading to possible ineffective treatment and high-power consumption. In order to improve the process efficiency, this work analyzes the effects of ultrasonic power, frequency, and load toward the cleaning of crude oil-contaminated sand, using two different sample positions and sand types. Crude oil-contaminated beach sand and produced sand from offshore oil well were used as samples. They were cleaned in custom-made ultrasonic bath reactor for 10 min with power from 30 to 120 W, frequency covering 25-60 kHz, and sand load of 10-100 g. With experimental design consisting multiple factors and levels, the interactions between factors in all possible combinations were determined using ANOVA (n = 210). From p-value based at 95% confidence interval and extensive F test, the three most significant factors were the sand type, the ultrasonic frequency, and the interaction between sand type and frequency. The best setting for suspended samples involved high frequency of 60 kHz, whereas bottom samples preferred low frequency at 28 kHz. This finding was justified when the acoustic pressure attenuation, standing wave pattern, and surface pitting/cracking were found in correlation with the cleaning results. Overall, the maximum treatment under ultrasonic bath solely gained around 60%, improvable by hybrid cleaning with other techniques such as chemical, biological, mechanical, and thermal.
    Matched MeSH terms: Ultrasonics
  11. Vivekananda Pai AR, Arora V
    J Conserv Dent, 2018 4 21;21(2):230-232.
    PMID: 29674831 DOI: 10.4103/JCD.JCD_316_16
    A metallic obstruction in the canal orifice of a maxillary right canine could not be bypassed during endodontic treatment. Aids such as ultrasonics and retrieval kits were not available for the removal of the obstruction. Therefore, a novel approach using a disposable syringe needle was employed. A 22-gauge needle was inserted into the orifice and turned in an arc with a gentle apical pressure and alternate rocking motion around the obstruction. This procedure was repeated few times to cut dentin and successfully dislodge and remove the obstruction using the sharp beveled tip of the needle. This case report demonstrates that, in the absence of other aids, the use of a disposable syringe needle is a simple, economical, and yet an effective technique for conservative removal of dentin and to dislodge and remove an obstruction from the root canal. However, its effectiveness depends on case selection and straight-line accessibility to the obstruction.
    Matched MeSH terms: Ultrasonics
  12. Yusof NS, Ashokkumar M
    Chemphyschem, 2015 Mar 16;16(4):775-81.
    PMID: 25598360 DOI: 10.1002/cphc.201402697
    The sonochemical synthesis of gold nanoparticles (GNPs) with different shapes and size distributions by using high-intensity focused ultrasound (HIFU) operating at 463 kHz is reported. GNP formation proceeds through the reduction of Au(3+) to Au(0) by radicals generated by acoustic cavitation. TEM images reveal that GNPs show irregular shapes at 30 W, are primarily icosahedral at 50 W and form a significant amount of nanorods at 70 W. The size of GNPs decreases with increasing acoustic power with a narrower size distribution. Sonochemiluminescence images help in the understanding of the effect of HIFU in controlling the size and shapes of GNPs. The number of radicals that form and the mechanical forces that are generated control the shape and size of the GNPs. UV/Vis spectra and TEM images are used to propose a possible mechanism for the observed effects. The results presented demonstrate, for the first time, that the HIFU system can be used to synthesise size- and shape-controlled metal nanoparticles.
    Matched MeSH terms: Ultrasonics*
  13. Hazwani A, Sha'Ban M, Azhim A
    Organogenesis, 2019;15(4):120-136.
    PMID: 31495272 DOI: 10.1080/15476278.2019.1656997
    Extracellular matrix (ECM) based bioscaffolds prepared by decellularization has increasingly emerged in tissue engineering application because it has structural, biochemical, and biomechanical cues that have dramatic effects upon cell behaviors. Therefore, we developed a closed sonication decellularization system to prepare ideal bioscaffolds with minimal adverse effects on the ECM. The decellularization was achieved at 170 kHz of ultrasound frequency in 0.1% and 2% Sodium Dodecyl Sulphate (SDS) solution for 10 hours. The immersion treatment as control was performed to compare the decellularization efficiency with our system. Cell removal and ECM structure were determined by histological staining and biochemical assay. Biomechanical properties were investigated by the indentation testing to test the stiffness, a residual force and compression of bioscaffolds. Additionally, in vivo implantation was performed in rat to investigate host tissue response. Compared to native tissues, histological staining and biochemical assay confirm the absence of cellularity with preservation of ECM structure. Moreover, sonication treatment has not affected the stiffness [N/mm] and a residual force [N] of the aortic scaffolds except for compression [%] which 2% SDS significantly decreased compared to native tissues showing higher SDS has a detrimental effect on ECM structure. Finally, minimal inflammatory response was observed after 1 and 5 weeks of implantation. This study reported that the novelty of our developed closed sonication system to prepare ideal bioscaffolds for tissue engineering applications.
    Matched MeSH terms: Ultrasonics
  14. Huseien GF, Sam ARM, Faridmehr I, Baghban MH
    Materials (Basel), 2021 Mar 06;14(5).
    PMID: 33800835 DOI: 10.3390/ma14051255
    This research investigated the application of epoxy resin polymer as a self-healing strategy for improving the mechanical and durability properties of cement-based mortar. The epoxy resin was added to the concrete mix at various levels (5, 10, 15, and 20% of cement weight), and the effectiveness of healing was evaluated by microstructural analysis, compressive strength, and non-destructive (ultrasonic pulse velocity) tests. Dry and wet-dry conditions were considered for curing, and for generating artificial cracks, specimens at different curing ages (1 and 6 months) were subjected to compressive testing (50 and 80% of specimen's ultimate compressive strength). The results indicated that the mechanical properties in the specimen prepared by 10% epoxy resin and cured under wet-dry conditions was higher compared to other specimens. The degree of damage and healing efficiency index of this particular mix design were significantly affected by the healing duration and cracking age. An optimized artificial neural network (ANN) combined with a firefly algorithm was developed to estimate these indexes over the self-healing process. Overall, it was concluded that the epoxy resin polymer has high potential as a mechanical properties self-healing agent in cement-based mortar.
    Matched MeSH terms: Ultrasonics
  15. Hoo DY, Low ZL, Low DYS, Tang SY, Manickam S, Tan KW, et al.
    Ultrason Sonochem, 2022 Nov;90:106176.
    PMID: 36174272 DOI: 10.1016/j.ultsonch.2022.106176
    With rising consumer demand for natural products, a greener and cleaner technology, i.e., ultrasound-assisted extraction, has received immense attention given its effective and rapid isolation for nanocellulose compared to conventional methods. Nevertheless, the application of ultrasound on a commercial scale is limited due to the challenges associated with process optimization, high energy requirement, difficulty in equipment design and process scale-up, safety and regulatory issues. This review aims to narrow the research gap by placing the current research activities into perspectives and highlighting the diversified applications, significant roles, and potentials of ultrasound to ease future developments. In recent years, enhancements have been reported with ultrasound assistance, including a reduction in extraction duration, minimization of the reliance on harmful chemicals, and, most importantly, improved yield and properties of nanocellulose. An extensive review of the strengths and weaknesses of ultrasound-assisted treatments has also been considered. Essentially, the cavitation phenomena enhance the extraction efficiency through an increased mass transfer rate between the substrate and solvent due to the implosion of microbubbles. Optimization of process parameters such as ultrasonic intensity, duration, and frequency have indicated their significance for improved efficiency.
    Matched MeSH terms: Ultrasonics*
  16. Yunus R, Salleh SF, Abdullah N, Biak DR
    Bioresour Technol, 2010 Dec;101(24):9792-6.
    PMID: 20719502 DOI: 10.1016/j.biortech.2010.07.074
    Various pre-treatment techniques change the physical and chemical structure of the lignocellulosic biomass and improve hydrolysis rates. The effect of ultrasonic pre-treatment on oil palm empty fruit bunch (OPEFB) fibre prior to acid hydrolysis has been evaluated. The main objective of this study was to determine if ultrasonic pre-treatment could function as a pre-treatment method for the acid hydrolysis of OPEFB fibre at a low temperature and pressure. Hydrolysis at a low temperature was studied using 2% sulphuric acid; 1:25 solid liquid ratio and 100 degrees C operating temperature. A maximum xylose yield of 58% was achieved when the OPEFB fibre was ultrasonicated at 90% amplitude for 45min. In the absence of ultrasonic pre-treatment only 22% of xylose was obtained. However, no substantial increase of xylose formation was observed for acid hydrolysis at higher temperatures of 120 and 140 degrees C on ultrasonicated OPEFB fibre. The samples were then analysed using a scanning electron microscope (SEM) to describe the morphological changes of the OPEFB fibre. The SEM observations show interesting morphological changes within the OPEFB fibre for different acid hydrolysis conditions.
    Matched MeSH terms: Ultrasonics/methods*
  17. Leman, A.M., Fatin Afiqah Jajuli, Dafit Feriyanto
    MyJurnal
    Automobile exhaust emission control is one of the trending issues in automobile research field. It caused by high
    pollution such as carbon monoxide (CO), nitrogen oxides (NOx), and hydrocarbons (HC) distributed by automobile
    especially form diesel engine. These pollutants give a harmful effect to the environment and human health. Therefore,
    this paper proposed in reviewing methods on fabrication of modified catalytic converter. FeCrAl is used as substrate
    which treated using ultrasonic bath technique which could improve the exhaust emission control. This metallic catalytic converter used as the replacement of precious metal that have high production cost.
    Matched MeSH terms: Ultrasonics
  18. Chong KH, Poh BK, Jamil NA, Kamaruddin NA, Deurenberg P
    Biomed Res Int, 2015;2015:232876.
    PMID: 25922831 DOI: 10.1155/2015/232876
    Aim. To validate a radial quantitative ultrasound (QUS) system with dual energy X-ray absorptiometry (DXA), a criterion technique in bone status assessment among children. Methods. Bone health was evaluated using a radial QUS system (Sunlight Omnisense 8000P) to measure the speed of sound (SOS) at one-third distal radius of the nondominant hand and DXA (Hologic QDR) was used to assess whole body bone mineral density (BMD). Results. Some 29.9% of the children were grossly misclassified according to quartiles of BMD and radial SOS. Poor agreement was observed between Z-scores of radial SOS and whole-body BMD (mean difference = 0.6 ± 0.9; 95% limits of agreement = -1.4 to 2.6). With a cut-off value of -1.0, radial SOS yielded satisfactory sensitivity (80%) and specificity (93%) for the detection of children with low BMD. Conclusion. The observed poor agreement in the present study suggests that radial QUS and DXA are not comparable and hence are not interchangeable in evaluating bone status of the children.
    Matched MeSH terms: Ultrasonics/methods*
  19. Deori A, Gupta N, Gupta AK, Yelamanchi R, Agrawal H, Durga CK
    Malays J Med Sci, 2021 Feb;28(1):97-104.
    PMID: 33679225 DOI: 10.21315/mjms2021.28.1.12
    Background: Axillary dissection is one of the important components of modified radical mastectomy (MRM). The present study was conducted to compare surgical outcomes by using monopolar electrocautery and ultrasonic dissector for axillary dissection in MRM.

    Methods: A parallel randomised controlled single blinded study was conducted with a sample size of 70 patients who were randomised into two groups. One group underwent MRM using ultrasonic dissector (Group A) and the other one using electrocautery (Group B). Intra- and post-operative outcomes were compared.

    Results: Group A had an average operating time of 30.86 min, which was statistically less than that of Group B. The mean mop count and the daily drain output in Group A were less as compared to Group B and the differences were statistically significant. Drain was removed early in Group A as compared to Group B. However, post-operative pain scores and seroma formation were not statistically significant among the two groups.

    Conclusion: Ultrasonic dissector group had significantly lesser intra-operative bleeding, operating time and post-operative drain output when compared to electrocautery group. However, the two groups had no significant difference in post-operative pain scores and seroma formation.

    Matched MeSH terms: Ultrasonics
  20. Latiff NA, Ong PY, Abd Rashid SNA, Abdullah LC, Mohd Amin NA, Fauzi NAM
    Sci Rep, 2021 08 27;11(1):17297.
    PMID: 34453075 DOI: 10.1038/s41598-021-96623-x
    Cosmos caudatus (C. caudatus) is a medicinal plant that is high in bioactive compounds such as phenolics. In this study, an ultrasound extraction method was used to optimise the extraction of bioactive compounds from C. caudatus leaves. Response surface methodology (RSM) based on a Box-Behnken design (BBD) was applied to obtain the optimum extraction parameters which is solid-liquid ratio (10-30 g/mL), particle size (180-850 µm) and extraction time (20-30 min) for maximal quercitrin and total phenolic content (TPC) yields. Analysis of antimicrobial activity was performed against two human pathogenic microbes: Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) by the agar well diffusion method. The optimal ultrasonic extraction condition was as follow: solvent-liquid ratio of 1:28 (g/mL), particle size of 485 µm, and duration of 30 min, respectively. Remarkably, extraction using ultrasonic method had recovered more bioactive content and antioxidant activity than the Soxhlet method. The extract also exhibited good antimicrobial activities. Due to the above findings, the ultrasonic extraction was found to be suitable to improve recovery extraction of quercitrin and TPC from C. caudatus leaves. It also opens the possibility that the plant extract can be used for functional food and antimicrobial agents in various applications.
    Matched MeSH terms: Ultrasonics
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links