Displaying publications 1 - 20 of 106 in total

Abstract:
Sort:
  1. Peyman M, Tai LY, Khaw KW, Ng CM, Win MM, Subrayan V
    Int Ophthalmol, 2015 Oct;35(5):651-5.
    PMID: 25189684 DOI: 10.1007/s10792-014-9989-6
    To assess the intra-observer repeatability and inter-observer reproducibility of central corneal thickness (CCT) measurements of PachPen (Accutome, Inc., Pennsylvania, USA), a hand-held, portable ultrasonic pachymeter when used by an ophthalmic nurse compared to an ophthalmologist. Ophthalmology Clinic, University of Malaya Medical Center In this prospective study, CCT was measured in 184 eyes of 92 healthy subjects, first by a corneal surgeon experienced in ultrasound pachymetry (Observer 1) followed by an ophthalmic nurse new to the procedure (Observer 2). Nine measurements were obtained from each eye by each observer, independently. Measurements were compared between the observers. Coefficients of repeatability and reproducibility were calculated. The Bland-Altman plot was used to assess agreement between observers. Mean age of the study population was 54.3 ± 15.2 years old and consisted of 43.5% male. Mean CCT as measured by Observers 1 and 2 were 528.3 ± 32.9 and 530.7 ± 33.3 µm, respectively. Observer 1 showed higher repeatability of measurements compared to that of Observer 2 (coefficient of repeatability 3.46 vs. 5.55%). The measurements by both observers showed high correlation (0.96) and good agreement (mean difference -2.4 µm; 95% limits of agreement -21.4, 16.7 µm). Coefficient of reproducibility of measurements between observers was 5.08%. Accutome PachPen hand-held ultrasound pachymeters gives excellent intra-observer repeatability and inter-observer reproducibility by personnel of different training grades.
    Matched MeSH terms: Ultrasonics
  2. Suhaimi SH, Hasham R, Hafiz Idris MK, Ismail HF, Mohd Ariffin NH, Abdul Majid FA
    Molecules, 2019 Nov 18;24(22).
    PMID: 31752230 DOI: 10.3390/molecules24224183
    Primarily, optimization of ultrasonic-assisted extraction (UAE) conditions of Orthospihon stamineus was evaluated and verified using a central composite design (CCD) based on three factors including extraction time (minutes), ultrasound amplitude (A), and solvent concentration (%). The response surface methodology (RSM) was performed to develop an extraction method with maximum yield and high rosmarinic acid content. The optimal UAE conditions were as follows: extraction time 21 min, ultrasound amplitudes 62 A, and solvent composition 70% ethanol in water. The crude extract was further fractionated using solid-phase extraction (SPE), where six sequential fractions that varied in polarity (0-100% Acetonitrile in water) were obtained. Next, the six fractions were evaluated for their antioxidant and anti-cancer properties. This study found that Fraction 2 (F2) contained the highest rosmarinic acid content and showed the strongest antioxidant activity. Additionally, F2 showed an anti-proliferative effect against prostate cancer (DU145) with no harmful effect on normal cells.
    Matched MeSH terms: Ultrasonics
  3. Latiff NA, Ong PY, Abd Rashid SNA, Abdullah LC, Mohd Amin NA, Fauzi NAM
    Sci Rep, 2021 08 27;11(1):17297.
    PMID: 34453075 DOI: 10.1038/s41598-021-96623-x
    Cosmos caudatus (C. caudatus) is a medicinal plant that is high in bioactive compounds such as phenolics. In this study, an ultrasound extraction method was used to optimise the extraction of bioactive compounds from C. caudatus leaves. Response surface methodology (RSM) based on a Box-Behnken design (BBD) was applied to obtain the optimum extraction parameters which is solid-liquid ratio (10-30 g/mL), particle size (180-850 µm) and extraction time (20-30 min) for maximal quercitrin and total phenolic content (TPC) yields. Analysis of antimicrobial activity was performed against two human pathogenic microbes: Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) by the agar well diffusion method. The optimal ultrasonic extraction condition was as follow: solvent-liquid ratio of 1:28 (g/mL), particle size of 485 µm, and duration of 30 min, respectively. Remarkably, extraction using ultrasonic method had recovered more bioactive content and antioxidant activity than the Soxhlet method. The extract also exhibited good antimicrobial activities. Due to the above findings, the ultrasonic extraction was found to be suitable to improve recovery extraction of quercitrin and TPC from C. caudatus leaves. It also opens the possibility that the plant extract can be used for functional food and antimicrobial agents in various applications.
    Matched MeSH terms: Ultrasonics
  4. Tang SY, Sivakumar M, Ng AM, Shridharan P
    Int J Pharm, 2012 Jul 1;430(1-2):299-306.
    PMID: 22503988 DOI: 10.1016/j.ijpharm.2012.03.055
    The present study investigated the anti-inflammatory and analgesic activities of novel aspirin oil-in-water (O/W) nanoemulsion and water-in-oil-in-water (W/O/W) nano multiple emulsion formulations generated using ultrasound cavitation techniques. The anti-inflammatory activities of nanoemulsion and nano multiple emulsion were determined using the λ-carrageenan-induced paw edema model. The analgesic activities of both nanoformulations were determined using acetic acid-induced writhing response and hot plate assay. For comparison, the effect of pretreatment with blank nanoemulsion and reference aspirin suspension were also studied for their anti-inflammatory and antinociceptive activities. The results showed that oral administration of nanoemulsion and nano multiple emulsion containing aspirin (60 mg/kg) significantly reduced paw edema induced by λ-carrageenan injection. Both nanoformulations decreased the number of abdominal constriction in acetic acid-induced writhing model. Pretreatment with nanoformulations led to a significant increase in reaction time in hot plate assay. Nanoemulsion demonstrated an enhanced anti-inflammatory and analgesic effects compared to reference suspension while nano multiple emulsion exhibited a mild inhibitory effects in the three experimental animal model tests. The results obtained for nano multiple emulsion were relatively lower than reference. However, administration of blank nanoemulsion did not alter the nociceptive response significantly though it showed slight anti-inflammatory effect. These experimental studies suggest that nanoemulsion and nano multiple emulsion produced a pronounced anti-inflammatory and analgesic effects in rats and may be candidates as new nanocarriers for pharmacological NSAIDs in the treatment of inflammatory disorders and alleviating pains.
    Matched MeSH terms: Ultrasonics*
  5. Zainol H, Sumithran E
    Histopathology, 1993 Jun;22(6):581-6.
    PMID: 7689070
    This study evaluates the usefulness of a combined cytological and histological approach to the diagnosis of hepatocellular carcinoma (HCC) when applied to fine needle biopsy specimens obtained under ultrasonic guidance. The material, aspirated from 51 focal liver lesions, was handled in such a way that there was sufficient material for both cytological and histological (cell block) assessment. Of the 29 cases of HCC studied, a confident cytological diagnosis was made in 23 (79%). In the remaining six cases, the cytological features were considered to be suspicious but not diagnostic of HCC. Examination of cell blocks in the six cases enabled a confident diagnosis of HCC to be made in all cases. This was due to the supplementary visual information provided by the histological features, particularly the pattern of arrangement of the tumour cells.
    Matched MeSH terms: Ultrasonics
  6. Hazwani A, Sha'Ban M, Azhim A
    Organogenesis, 2019;15(4):120-136.
    PMID: 31495272 DOI: 10.1080/15476278.2019.1656997
    Extracellular matrix (ECM) based bioscaffolds prepared by decellularization has increasingly emerged in tissue engineering application because it has structural, biochemical, and biomechanical cues that have dramatic effects upon cell behaviors. Therefore, we developed a closed sonication decellularization system to prepare ideal bioscaffolds with minimal adverse effects on the ECM. The decellularization was achieved at 170 kHz of ultrasound frequency in 0.1% and 2% Sodium Dodecyl Sulphate (SDS) solution for 10 hours. The immersion treatment as control was performed to compare the decellularization efficiency with our system. Cell removal and ECM structure were determined by histological staining and biochemical assay. Biomechanical properties were investigated by the indentation testing to test the stiffness, a residual force and compression of bioscaffolds. Additionally, in vivo implantation was performed in rat to investigate host tissue response. Compared to native tissues, histological staining and biochemical assay confirm the absence of cellularity with preservation of ECM structure. Moreover, sonication treatment has not affected the stiffness [N/mm] and a residual force [N] of the aortic scaffolds except for compression [%] which 2% SDS significantly decreased compared to native tissues showing higher SDS has a detrimental effect on ECM structure. Finally, minimal inflammatory response was observed after 1 and 5 weeks of implantation. This study reported that the novelty of our developed closed sonication system to prepare ideal bioscaffolds for tissue engineering applications.
    Matched MeSH terms: Ultrasonics
  7. Saleh MSM, Bukhari DAM, Siddiqui MJA, Kasmuri AR, Murugesu S, Khatib A
    Nat Prod Res, 2020 May;34(9):1341-1344.
    PMID: 30678487 DOI: 10.1080/14786419.2018.1560295
    Different extraction processes were employed to extract bioactive metabolites from Salacca zalacca flesh by a range of aqueous and organic solvents. The highest extraction yield was obtained by 50% ethanol extract of SE (73.18 ± 4.35%), whereas SFE_1 showed the lowest yield (0.42 ± 0.08%). All extracts were evaluated for in vitro α-glucosidase inhibitory activity, measured by their IC50 values in comparison to that of quercetin, the positive control (IC50 = 2.7 ± 0.7 μg/mL). The lowest α-glucosidase inhibitory activity was indicated by water extract of SE (IC50 = 724.3 ± 42.9 μg/mL) and the highest activity was demonstrated by 60% ethanol extract by UAE (IC50 = 16.2 ± 2.4 μg/mL). All extracts were analysed by GC-MS and identified metabolites like carbohydrates, fatty acids, organic acids, phenolic acids, sterols and alkane-based compounds etcetera that may possess the potential as α-glucosidase inhibitor and may attribute to the α-glucosidase inhibitory activity.
    Matched MeSH terms: Ultrasonics
  8. Abidin NZ, Mitra SR
    Curr Gerontol Geriatr Res, 2021;2021:6634474.
    PMID: 33790963 DOI: 10.1155/2021/6634474
    Osteosarcopenic obesity (OSO) describes the concurrent presence of obesity, low bone mass, and low muscle mass in an individual. Currently, no established criteria exist to diagnose OSO. We hypothesized that obese individuals require different cut-points from standard cut-points to define low bone mass and low muscle mass due to their higher weight load. In this study, we determined cutoff values for the screening of osteosarcopenia (OS) in obese postmenopausal Malaysian women based on the measurements of quantitative ultrasound (QUS), bioelectrical impedance analysis (BIA), and functional performance test. Then, we compared the cutoff values derived by 3 different statistical modeling methods, (1) receiver operating characteristic (ROC) curve, (2) lowest quintile of the study population, and (3) 2 standard deviations (SD) below the mean value of a young reference group, and discussed the most suitable method to screen for the presence of OS in obese population. One hundred and forty-one (n = 141) postmenopausal Malaysian women participated in the study. Bone density was assessed using calcaneal quantitative ultrasound. Body composition was assessed using bioelectrical impedance analyzer. Handgrip strength was assessed using a handgrip dynamometer, and physical performance was assessed using a modified Short Physical Performance Battery test. ROC curve was determined to be the most suitable statistical modeling method to derive the cutoffs for the presence of OS in obese population. From the ROC curve method, the final model to estimate the probability of OS in obese postmenopausal women is comprised of five variables: handgrip strength (HGS, with area under the curve (AUC) = 0.698 and threshold ≤ 16.5 kg), skeletal muscle mass index (SMMI, AUC = 0.966 and threshold ≤ 8.2 kg/m2), fat-free mass index (FFMI, AUC = 0.946 and threshold ≤ 15.2 kg/m2), broadband ultrasonic attenuation (BUA, AUC = 0.987 and threshold ≤ 52.85 dB/MHz), and speed of sound (SOS, AUC = 0.991 and threshold ≤ 1492.15 m/s). Portable equipment may be used to screen for OS in obese women. Early identification of OS can help lower the risk of advanced functional impairment that can lead to physical disability in obese postmenopausal women.
    Matched MeSH terms: Ultrasonics
  9. Ahmad Zaiki FW, Md Dom S, Abdul Razak HR, Hassan HF
    Quant Imaging Med Surg, 2013 Oct;3(5):262-8.
    PMID: 24273744 DOI: 10.3978/j.issn.2223-4292.2013.10.05
    Prenatal Ultrasound (US) is commonly used as a routine procedure on pregnant women. It is generally perceived as a safe procedure due to the use of non-ionizing radiation. However, the neurotoxicity of diagnostic prenatal US was detected to have a correlation with high susceptibility to early developing fetus. This research involved in vivo experimental model by using 3(rd) trimester pregnant Oryctolagus cuniculus and exposing them to US exposures for 30, 60, and 90 minutes at their gestational day (GD) 28-29. The output power and intensities, spatial peak temporal average intensity (ISPTA) of US were varied from 0.4 to 0.7 W and 0.13 to 0.19 W/cm(2) respectively were tested initially in free-field, water. Haematological analysis was carried out to detect any changes in blood constituents. Statistically significant differences were detected in red blood cell (RBC) count (P<0.001), haemoglobin (Hb) concentration (P<0.001) and also platelet (PLT) count (P<0.001) in newborn of Oryctolagus cuniculus. These findings indicate the possibility of US heating in causing defects on studied animal.
    Matched MeSH terms: Ultrasonics
  10. Abdullah AZ, Ling PY
    J Hazard Mater, 2010 Jan 15;173(1-3):159-67.
    PMID: 19740600 DOI: 10.1016/j.jhazmat.2009.08.060
    The ambient sonocatalytic degradation of congo red, methyl orange, and methylene blue by titanium dioxide (TiO(2)) catalyst at initial concentrations between 10 and 50mg/L, catalyst loadings between 1.0 and 3.0mg/L and hydrogen peroxide (H(2)O(2)) concentrations up to 600 mg/L is reported. A 20 kHz ultrasonic processor at 50 W was used to accelerate the reaction. The catalysts were exposed to heat treatments between 400 and 1000 degrees C for up to 4h to induce phase change. Sonocatalysts with small amount of rutile phase showed better sonocatalytic activity but excessive rutile phase should be avoided. TiO(2) heated to 800 degrees C for 2h showed the highest sonocatalytic activity and the degradation of dyes was influenced by their chemical structures, chemical phases and characteristics of the catalysts. Congo red exhibited the highest degradation rate, attributed to multiple labile azo bonds to cause highest reactivity with the free radicals generated. An initial concentration of 10mg/L, 1.5 g/L of catalyst loading and 450 ppm of H(2)O(2) gave the best congo red removal efficiency of above 80% in 180 min. Rate coefficients for the sonocatalytic process was successfully established and the reused catalyst showed an activity drop by merely 10%.
    Matched MeSH terms: Ultrasonics*
  11. Ismail NA, Shameli K, Wong MM, Teow SY, Chew J, Sukri SNAM
    Mater Sci Eng C Mater Biol Appl, 2019 Nov;104:109899.
    PMID: 31499959 DOI: 10.1016/j.msec.2019.109899
    In this study, a comparative study of effect using honey on copper nanoparticles (Cu-NPs) via simple, environmentally friendly process and inexpensive route was reported. Honey and ascorbic acid act as stabilizing and reducing agents with the assistance of sonochemical method. The products were characterized using UV-visible (UV-vis) spectroscopy, X-Ray Diffraction (XRD), High-Resolution Transmission Electron Microscopy (HRTEM), Field-Emission Scanning Electron Microscopy (FESEM) and Fourier Transform Infrared (FTIR) spectroscopy. The reddish brown colour demonstrated the formation of Cu-NPs and UV-visible proved the plasmon resonance of Cu-NPs. XRD also confirmed a highly pure Cu-NPs obtained with absence of copper oxide in which the structure is crystalline. The spherical size of the Cu-NPs was acquire in the presence of honey which is 3.68 ± 0.78 nm with narrow particle distribution. The antibacterial activity was seen against gram-positive and gram-negative bacteria which are Enterococcus faecalis (E. faecalis) and Escherichia coli (E. coli). At higher concentration of Cu-NPs, they were more effective in killing both bacteria. The Cu-NPs without and with honey exhibited toxicities toward normal and cancerous cells. However, Cu-NPs without honey showed more potent killing activity against normal and cancer cells.
    Matched MeSH terms: Ultrasonics*
  12. Noroozi M, Zakaria A, Radiman S, Abdul Wahab Z
    PLoS One, 2016;11(4):e0152699.
    PMID: 27064575 DOI: 10.1371/journal.pone.0152699
    In this paper, we report how few layers graphene that can be produced in large quantity with low defect ratio from exfoliation of graphite by using a high intensity probe sonication in water containing liquid hand soap and PVP. It was founded that the graphene powder obtained by this simple exfoliation method after the heat treatment had an excellent exfoliation into a single or layered graphene sheets. The UV-visible spectroscopy, FESEM, TEM, X-ray powder diffraction and Raman spectroscopy was used to analyse the graphene product. The thermal diffusivity of the samples was analysed using a highly accurate thermal-wave cavity photothermal technique. The data obtained showed excellent enhancement in the thermal diffusivity of the graphene dispersion. This well-dispersed graphene was then used to fabricate an electrically conductive polymer-graphene film composite. The results demonstrated that this low cost and environmental friendly technique allowed to the production of high quality layered graphene sheets, improved the thermal and electrical properties. This may find use in the wide range of applications based on graphene.
    Matched MeSH terms: Ultrasonics/methods*
  13. Jibril S, Basar N, Sirat HM, Wahab RA, Mahat NA, Nahar L, et al.
    Phytochem Anal, 2019 Jan;30(1):101-109.
    PMID: 30288828 DOI: 10.1002/pca.2795
    INTRODUCTION: Cassia singueana Del. (Fabaceae) is a rare medicinal plant used in the traditional medicine preparations to treat various ailments. The root of C. singueana is a rich source of anthraquinones that possess anticancer, antibacterial and antifungal properties.

    OBJECTIVE: The objective of this study was to develop an ultrasound-assisted extraction (UAE) method for achieving a high extraction yield of anthraquinones using the response surface methodology (RSM), Box-Behnken design (BBD), and a recycling preparative high-performance liquid chromatography (HPLC) protocol for isolation of anthraquinones from C. singueana.

    METHODOLOGY: Optimisation of UAE was performed using the Box-Behnken experimental design. Recycling preparative HPLC was employed to isolate anthraquinones from the root extract of C. singueana.

    RESULTS: The BBD was well-described by a quadratic polynomial model (R2  = 0.9751). The predicted optimal UAE conditions for a high extraction yield were obtained at: extraction time 25.00 min, temperature 50°C and solvent-sample ratio of 10 mL/g. Under the predicted conditions, the experimental value (1.65 ± 0.07%) closely agreed to the predicted yield (1.64%). The obtained crude extract of C. singueana root was subsequently purified to afford eight anthraquinones.

    CONCLUSION: The extraction protocol described here is suitable for large-scale extraction of anthraquinones from plant extracts.

    Matched MeSH terms: Ultrasonics/methods*
  14. Sobhanzadeh E, Abu Bakar NK, Bin Abas MR, Nemati K
    J Hazard Mater, 2011 Feb 28;186(2-3):1308-13.
    PMID: 21177032 DOI: 10.1016/j.jhazmat.2010.12.001
    A simple and effective multiresidue method based on precipitation at low temperature followed by matrix solid-phase dispersion-sonication was developed and validated to determine dimethoate, malathion, carbaryl, simazine, terbuthylazine, atrazine and diuron in palm oil using liquid chromatography time-of-flight mass spectrometry (LC-TOF-MS). Liquid-liquid extraction (LLE) followed by low temperature method were optimized by studying the effect of type and volume of organic solvent (acetonitrile, acetonitrile:n-hexane (3:2 v/v) and acetone) and time of freezing to obtain high recovery yield and low co-extract fat residue in the final extract. The optimal conditions for matrix solid-phase dispersion (MSPD) were obtained using 5 g of palm oil, 2 g of primary secondary amine (PSA) as dispersing sorbent, 1 g of graphitized carbon black (GCB) as clean-up sorbent and 15 mL of acetonitrile as eluting solvent under conditions of 15 min ultrasonication at room temperature. Method validation was performed in order to study sensitivity, linearity, precision, and accuracy. Average recoveries at three concentration levels (25, 50 and 100 μg kg(-1)) were found in the range of 72.6-91.3% with relative standard deviations between 5.3% and 14.2%. Detection and quantification limits ranged from 1.5 to 5 μg kg(-1) and from 2.5 to 9 μg kg(-1), respectively.
    Matched MeSH terms: Ultrasonics
  15. Ling BC, Gillings BR
    Asian J Aesthet Dent, 1995;3:17-21.
    PMID: 9063105
    With the prognosis of dental implant replacement of missing teeth becoming better each year, practitioners are focusing their attention on the aesthetic aspects of implantology. However, improvement in aesthetics is only possible with the improvement in implant technology, surgical techniques and prosthodontic procedures. This study aimed at evaluating the effects of various physical and chemical agents on the implant surface; with the view of obtaining increased surface area and biocompatibility. The study found that the treatment of air-aluminum oxide blasted implants using a mixture of 30% HNO3-5% HF acids produced a surface which meets the consideration of aesthetics for implants placed in the anterior maxillary region.
    Matched MeSH terms: Ultrasonics
  16. Saud, Safaa Najah, Manivannan, Dasarataan, Adzliza Binti Salmi, Lilysuriazna Raya
    MyJurnal
    Nowadays, the scientific knowledge is developing frequently in numerous characteristics to be able to offer versatile and also safe and sound tendency for the users. At this time many of prevalent together with employed indicate by the visually impaired people are using the ivory stick, nonetheless it possesses constraints. With the recent technological innovation, it is easy to prolong the assistance acquire for people who have visual disability throughout their movability; this design endorses a cost-effective ultrasonic stick for visually encountered people today, to be able to achieve an exclusive self-reliance and even exempt from the additional assist. A portable convenient to use technology is designed which could recognize the obstructions in the way working with ultrasonic sensors in addition to vibrator. Ultrasonic sensors will be able to inspect three types of distinct heights. Vibrator is frequently used as a substitute gadget in the areas that surrounds with the minimal signal coverage also nosy environment. The buzzer and vibration motor are initialized while any kind of hindrance is identified. Global positioning system device presents the details about to the proceeding approach both work or even home, that has been supplied considering that control keys together with a contingency switch. Text message unit is utilized by the blind to send out SMS info to the saved phone numbers in the Arduino in the event of unexpected emergency.

    Matched MeSH terms: Ultrasonics
  17. Ng TYS, Chew TL, Yeong YF, Jawad ZA, Ho CD
    Sci Rep, 2019 10 21;9(1):15062.
    PMID: 31636339 DOI: 10.1038/s41598-019-51460-x
    In recent years, there are increasing interest on applying ultrasonic irradiation for the synthesis of zeolite due to its advantages including remarkable shortened synthesis duration. In this project, the potential of ultrasonic irradiation treatment on the synthesis of zeolite RHO was investigated. Ultrasonic irradiation treatment time was varied from 30 to 120 minutes for the synthesis of zeolite RHO. The zeolite RHO solid samples were characterized with X-ray Diffraction (XRD), Field Emission Scanning Electron Microscopy (FESEM), Fourier Transform Infrared Spectroscopy (FTIR), Thermogravimetric Analysis (TGA) and nitrogen adsorption-desorption analysis. The application of ultrasonic irradiation treatment in this study has accelerated the synthesis of zeolite RHO where the synthesis duration has been significantly shortened to 2 days compared to 8 days required by conventional hydrothermal heating without ultrasonic irradiation treatment. Highly crystalline zeolite RHO crystals in truncated octahedron morphology were successfully formed.
    Matched MeSH terms: Ultrasonics
  18. Han Z, Sun J, Lv A, Sung Y, Sun X, Shi H, et al.
    AMB Express, 2018 Apr 02;8(1):52.
    PMID: 29610998 DOI: 10.1186/s13568-018-0578-3
    A modified genomic DNA extraction method named the combination of lysozyme and ultrasonic lysis (CLU) method was used to analyze the fish intestinal microflora. In this method, the physical disruption and chemical lysis steps were combined, and some parameters in the key steps were adjusted. In addition, the results obtained by this method were compared with the results obtained by the Zirmil-beating cell disruption method and the QIAamp Fast DNA Stool Mini Kit. The OD260/OD280ratio and concentration of the DNA extracted using the CLU method were 2.02 and 282.8 µg/µL, respectively; when the incubation temperatures for lysozyme and RNase were adjusted to 37 °C, those values were 2.08 and 309.8 µg/µL, respectively. On the agarose gel, a major high-intensity, discrete band of more than 10 kb was found for the CLU method. However, the smearing intensity of degraded DNA was lower when the incubation temperatures were 60 °C for lysozyme and 30 °C for RNase than when incubation temperatures of 37 °C for lysozyme and 37 °C for RNase were used. The V3 variable region of the prokaryotic 16S rDNA was amplified, and an approximately 600-bp fragment was observed when the DNA extracted using the CLU method was used as a template. The CLU method is simple and cost effective, and it yields high-quality, unsheared, high-molecular-weight DNA, which is comparable to that obtained with a commercially available kit. The extracted DNA has potential for applications in critical molecular biology techniques.
    Matched MeSH terms: Ultrasonics
  19. Mustapha bin Akil, Chong, Saw Peng, Norellia binti Bahari
    MyJurnal
    Stevia rebaudiana has recently gained the attention of the food industry as one of the natural sweeteners. The sweet flavour is contributed by the glycoside compounds, especially the rebaudioside A and stevioside, which are the stevia main chemical markers. The aim of the work reported here was to compare the different extraction techniques of stevia leaves using different technologies such as the high pressure and ultrasonic on the extraction of steviol glycosides. In this paper, the extraction techniques yielding the highest glycosides from the leaves of Stevia rebaudiana were determined using hot water extraction (HWE), pressurised liquid extraction (PLE) and ultrasound-assisted extraction (UAE). The steviol glycoside yields were quantified by two chemical markers, rebaudioside A and stevioside of Stevia rebaudiana using highperformance liquid chromatography (HPLC) analysis. The result showed that the HWE managed to obtain 1,110 mg of steviol glycosides. The PLE obtained 294 mg steviol glycosides and the UAE obtained 427.5 mg steviol glycosides. As a conclusion, the results suggested the most efficient technique for stevia extraction in this study was the HWE.
    Matched MeSH terms: Ultrasonics
  20. Gupta R, Kewalramani R
    J Oral Biol Craniofac Res, 2021 03 10;11(2):330-333.
    PMID: 33786296 DOI: 10.1016/j.jobcr.2021.03.001
    Aim: To evaluate the microleakage of newer bioceramic root-end filling materials.

    Material and method: Sixty freshly extracted human single-rooted mandibular premolar teeth were selected for the study. Teeth with fractured root, cracks, anddilacerations were rejected. All teeth were cleaned with ultrasonic scalers. Standard access opening was done and root canal treatment was performed with rotary files followed by obturation. After storing in saline for a week apical 3 ​mm of the root was resected at 900 angles to the long axis of the root. Retro cavity preparation was done with ultrasonic tips. The teeth were divided into four groups of 15 specimens each. Group I - Biodentin, GroupII-Bioaggregate, Group III - MTA Plus, and Group IV - MTA. After the restoration of retro cavities of all the teeth as per manufacture instructions, two coats of nail varnish were applied to leave apical 3 ​mm. All teeth were stored in 2% methylene blue for 72 ​h followed by emersion in 65% nitric acid for the next 72 ​h for Dye extraction. The obtained supernatant solution was then centrifuged and optical density or absorbance was measured with a UV spectrophotometer.

    Result: Microleakage was found to be increasing in this order: Biodentin ​ ​0.01).

    Conclusion: All materials exhibit some amount of microleakage. Biodentin shows the least microleakage among all the bioceramic material groups. Hence, Biodentin and bioaggregate are better material of choice for the retrograde filling to prevent microleakage.

    Matched MeSH terms: Ultrasonics
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links