Displaying publications 1 - 20 of 104 in total

Abstract:
Sort:
  1. Ahmad KA, Rahman MFA, Zain KAM, Haron MN, Manaf AA
    Sensors (Basel), 2021 Aug 19;21(16).
    PMID: 34451023 DOI: 10.3390/s21165582
    In acoustic receiver design, the receiving sensitivity and bandwidth are two primary parameters that determine the performance of a device. The trade-off between sensitivity and bandwidth makes the design very challenging, meaning it needs to be fine-tuned to suit specific applications. The ability to design a PMUT with high receiving sensitivity and a wide bandwidth is crucial to allow a wide spectrum of transmitted frequencies to be efficiently received. This paper presents a novel structure involving a double flexural membrane with a fluidic backing layer based on an in-plane polarization mode to optimize both the receiving sensitivity and frequency bandwidth for medium-range underwater acoustic applications. In this structure, the membrane material and electrode configuration are optimized to produce good receiving sensitivity. Simultaneously, a fluidic backing layer is introduced into the double flexural membrane to increase the bandwidth. Several piezoelectric membrane materials and various electrode dimensions were simulated using finite element analysis (FEA) techniques to study the receiving performance of the proposed structure. The final structure was then fabricated based on the findings from the simulation work. The pulse-echo experimental method was used to characterize and verify the performance of the proposed device. The proposed structure was found to have an improved bandwidth of 56.6% with a receiving sensitivity of -1.8864 dB rel 1 V µPa. For the proposed device, the resonance frequency and center frequency were 600 and 662.5 kHz, respectively, indicating its suitability for the targeted frequency range.
    Matched MeSH terms: Ultrasonics*
  2. Deori A, Gupta N, Gupta AK, Yelamanchi R, Agrawal H, Durga CK
    Malays J Med Sci, 2021 Feb;28(1):97-104.
    PMID: 33679225 DOI: 10.21315/mjms2021.28.1.12
    Background: Axillary dissection is one of the important components of modified radical mastectomy (MRM). The present study was conducted to compare surgical outcomes by using monopolar electrocautery and ultrasonic dissector for axillary dissection in MRM.

    Methods: A parallel randomised controlled single blinded study was conducted with a sample size of 70 patients who were randomised into two groups. One group underwent MRM using ultrasonic dissector (Group A) and the other one using electrocautery (Group B). Intra- and post-operative outcomes were compared.

    Results: Group A had an average operating time of 30.86 min, which was statistically less than that of Group B. The mean mop count and the daily drain output in Group A were less as compared to Group B and the differences were statistically significant. Drain was removed early in Group A as compared to Group B. However, post-operative pain scores and seroma formation were not statistically significant among the two groups.

    Conclusion: Ultrasonic dissector group had significantly lesser intra-operative bleeding, operating time and post-operative drain output when compared to electrocautery group. However, the two groups had no significant difference in post-operative pain scores and seroma formation.

    Matched MeSH terms: Ultrasonics
  3. Tan ZQ, Ooi EH, Chiew YS, Foo JJ, Ng EYK, Ooi ET
    Ultrasonics, 2023 May;131:106961.
    PMID: 36812819 DOI: 10.1016/j.ultras.2023.106961
    Sonothrombolysis is a technique that utilises ultrasound waves to excite microbubbles surrounding a clot. Clot lysis is achieved through mechanical damage induced by acoustic cavitation and through local clot displacement induced by acoustic radiation force (ARF). Despite the potential of microbubble-mediated sonothrombolysis, the selection of the optimal ultrasound and microbubble parameters remains a challenge. Existing experimental studies are not able to provide a complete picture of how ultrasound and microbubble characteristics influence the outcome of sonothrombolysis. Likewise, computational studies have not been applied in detail in the context of sonothrombolysis. Hence, the effect of interaction between the bubble dynamics and acoustic propagation on the acoustic streaming and clot deformation remains unclear. In the present study, we report for the first time the computational framework that couples the bubble dynamic phenomena with the acoustic propagation in a bubbly medium to simulate microbubble-mediated sonothrombolysis using a forward-viewing transducer. The computational framework was used to investigate the effects of ultrasound properties (pressure and frequency) and microbubble characteristics (radius and concentration) on the outcome of sonothrombolysis. Four major findings were obtained from the simulation results: (i) ultrasound pressure plays the most dominant role over all the other parameters in affecting the bubble dynamics, acoustic attenuation, ARF, acoustic streaming, and clot displacement, (ii) smaller microbubbles could contribute to a more violent oscillation and improve the ARF simultaneously when they are stimulated at higher ultrasound pressure, (iii) higher microbubbles concentration increases the ARF, and (iv) the effect of ultrasound frequency on acoustic attenuation is dependent on the ultrasound pressure. These results may provide fundamental insight that is crucial in bringing sonothrombolysis closer to clinical implementation.
    Matched MeSH terms: Ultrasonics
  4. Tiong TJ, Price GJ, Kanagasingam S
    Ultrason Sonochem, 2014 Sep;21(5):1858-65.
    PMID: 24735986 DOI: 10.1016/j.ultsonch.2014.03.024
    One of the uses of ultrasound in dentistry is in the field of endodontics (i.e. root canal treatment) in order to enhance cleaning efficiency during the treatment. The acoustic pressures generated by the oscillation of files in narrow channels has been calculated using the COMSOL simulation package. Acoustic pressures in excess of the cavitation threshold can be generated and higher values were found in narrower channels. This parallels experimental observations of sonochemiluminescence. The effect of varying the channel width and length and the dimensions and shape of the file are reported. As well as explaining experimental observations, the work provides a basis for the further development and optimisation of the design of endosonic files.
    Matched MeSH terms: Ultrasonics/instrumentation*
  5. Mohd Ishak NA, Khalil I, Abdullah FZ, Muhd Julkapli N
    Carbohydr Polym, 2020 Oct 15;246:116553.
    PMID: 32747237 DOI: 10.1016/j.carbpol.2020.116553
    Catalytic ionic liquid hydrolysis of cellulosic material have been considered as a green and highly efficient dissolution process. However, application of a pre-treatment process, i.e; ultrasonication enhances the hydrolysis of cellulose in ionic liquid by providing mechanical force. In this paper, we describe the impact of both chemical and mechanical approaches to produce nanocrytalline cellulose (NCC) with anticipated particle size, and crystallinity with improved yields. The ultrasonication treatment was evaluated in terms of treatment time and vibration amplitude. It was found that the lowest ultrasonication time (5 min) produced the NCC of highest crystallinity (73 %), but the lowest yield (84 %). In contrary, the highest ultrasonication vibration amplitude at 90 % produced NCC with highest crystallinity value (67 %) as well as yields (90 %). It concludes that ultrasonic pre-treatment improves the hydrolysis process of cellulose in ionic liquid with increasing yield and crystallinity of NCC.
    Matched MeSH terms: Ultrasonics
  6. Han Z, Sun J, Lv A, Sung Y, Sun X, Shi H, et al.
    AMB Express, 2018 Apr 02;8(1):52.
    PMID: 29610998 DOI: 10.1186/s13568-018-0578-3
    A modified genomic DNA extraction method named the combination of lysozyme and ultrasonic lysis (CLU) method was used to analyze the fish intestinal microflora. In this method, the physical disruption and chemical lysis steps were combined, and some parameters in the key steps were adjusted. In addition, the results obtained by this method were compared with the results obtained by the Zirmil-beating cell disruption method and the QIAamp Fast DNA Stool Mini Kit. The OD260/OD280ratio and concentration of the DNA extracted using the CLU method were 2.02 and 282.8 µg/µL, respectively; when the incubation temperatures for lysozyme and RNase were adjusted to 37 °C, those values were 2.08 and 309.8 µg/µL, respectively. On the agarose gel, a major high-intensity, discrete band of more than 10 kb was found for the CLU method. However, the smearing intensity of degraded DNA was lower when the incubation temperatures were 60 °C for lysozyme and 30 °C for RNase than when incubation temperatures of 37 °C for lysozyme and 37 °C for RNase were used. The V3 variable region of the prokaryotic 16S rDNA was amplified, and an approximately 600-bp fragment was observed when the DNA extracted using the CLU method was used as a template. The CLU method is simple and cost effective, and it yields high-quality, unsheared, high-molecular-weight DNA, which is comparable to that obtained with a commercially available kit. The extracted DNA has potential for applications in critical molecular biology techniques.
    Matched MeSH terms: Ultrasonics
  7. Peyman M, Tai LY, Khaw KW, Ng CM, Win MM, Subrayan V
    Int Ophthalmol, 2015 Oct;35(5):651-5.
    PMID: 25189684 DOI: 10.1007/s10792-014-9989-6
    To assess the intra-observer repeatability and inter-observer reproducibility of central corneal thickness (CCT) measurements of PachPen (Accutome, Inc., Pennsylvania, USA), a hand-held, portable ultrasonic pachymeter when used by an ophthalmic nurse compared to an ophthalmologist. Ophthalmology Clinic, University of Malaya Medical Center In this prospective study, CCT was measured in 184 eyes of 92 healthy subjects, first by a corneal surgeon experienced in ultrasound pachymetry (Observer 1) followed by an ophthalmic nurse new to the procedure (Observer 2). Nine measurements were obtained from each eye by each observer, independently. Measurements were compared between the observers. Coefficients of repeatability and reproducibility were calculated. The Bland-Altman plot was used to assess agreement between observers. Mean age of the study population was 54.3 ± 15.2 years old and consisted of 43.5% male. Mean CCT as measured by Observers 1 and 2 were 528.3 ± 32.9 and 530.7 ± 33.3 µm, respectively. Observer 1 showed higher repeatability of measurements compared to that of Observer 2 (coefficient of repeatability 3.46 vs. 5.55%). The measurements by both observers showed high correlation (0.96) and good agreement (mean difference -2.4 µm; 95% limits of agreement -21.4, 16.7 µm). Coefficient of reproducibility of measurements between observers was 5.08%. Accutome PachPen hand-held ultrasound pachymeters gives excellent intra-observer repeatability and inter-observer reproducibility by personnel of different training grades.
    Matched MeSH terms: Ultrasonics
  8. Molinari F, Raghavendra U, Gudigar A, Meiburger KM, Rajendra Acharya U
    Med Biol Eng Comput, 2018 Sep;56(9):1579-1593.
    PMID: 29473126 DOI: 10.1007/s11517-018-1792-5
    Atherosclerosis is a type of cardiovascular disease which may cause stroke. It is due to the deposition of fatty plaque in the artery walls resulting in the reduction of elasticity gradually and hence restricting the blood flow to the heart. Hence, an early prediction of carotid plaque deposition is important, as it can save lives. This paper proposes a novel data mining framework for the assessment of atherosclerosis in its early stage using ultrasound images. In this work, we are using 1353 symptomatic and 420 asymptomatic carotid plaque ultrasound images. Our proposed method classifies the symptomatic and asymptomatic carotid plaques using bidimensional empirical mode decomposition (BEMD) and entropy features. The unbalanced data samples are compensated using adaptive synthetic sampling (ADASYN), and the developed method yielded a promising accuracy of 91.43%, sensitivity of 97.26%, and specificity of 83.22% using fourteen features. Hence, the proposed method can be used as an assisting tool during the regular screening of carotid arteries in hospitals. Graphical abstract Outline for our efficient data mining framework for the characterization of symptomatic and asymptomatic carotid plaques.
    Matched MeSH terms: Ultrasonics
  9. Khan KM, Jamil W, Ambreen N, Taha M, Perveen S, Morales GA
    Ultrason Sonochem, 2014 May;21(3):1200-5.
    PMID: 24398059 DOI: 10.1016/j.ultsonch.2013.12.011
    Aldazines (Bis-Schiff bases) 1-24 were synthesized using aromatic aldehydes (heterocyclic and benzaldehydes) and hydrazine hydrate under reflux using conventional heating and/or via ultrasound irradiation using BiCl3 as catalyst. Ultrasonication conditions with cat. BiCl3 proved to be an effective, environmentally friendly synthetic procedure. This methodology is robust in the presence of electron donating and electron withdrawing groups affording desired products with high yields (>95%) in just a couple of minutes vs. hours using conventional heating.
    Matched MeSH terms: Ultrasonics*
  10. Sergeev A, Shilkina N, Motyakin M, Barashkova I, Zaborova V, Kanina K, et al.
    Ultrason Sonochem, 2021 Oct;78:105751.
    PMID: 34534797 DOI: 10.1016/j.ultsonch.2021.105751
    Methods of NMR relaxation and differential scanning calorimetry (DSC) were used to study the crystallization of anhydrous milk fat (AMF) obtained from milk and subjected to ultrasonic (US) processing. Amongst the changes in the crystallization nature under the influence of ultrasound are the decrease in the crystallization temperature and the increase in the melting enthalpy of the anhydrous milk fat samples. The increase is ∼30% at 20 min of isothermal crystallization and is presumably explained by the additional formation of β'-form crystals from the melt. The parameters of the Avrami equation applied to the description of experimental data show an increase in the crystallization rate in samples with ultrasonic treatment and a change in the dimension of crystallization with a change in melting temperature.
    Matched MeSH terms: Ultrasonics*
  11. Tang SY, Sivakumar M, Ng AM, Shridharan P
    Int J Pharm, 2012 Jul 1;430(1-2):299-306.
    PMID: 22503988 DOI: 10.1016/j.ijpharm.2012.03.055
    The present study investigated the anti-inflammatory and analgesic activities of novel aspirin oil-in-water (O/W) nanoemulsion and water-in-oil-in-water (W/O/W) nano multiple emulsion formulations generated using ultrasound cavitation techniques. The anti-inflammatory activities of nanoemulsion and nano multiple emulsion were determined using the λ-carrageenan-induced paw edema model. The analgesic activities of both nanoformulations were determined using acetic acid-induced writhing response and hot plate assay. For comparison, the effect of pretreatment with blank nanoemulsion and reference aspirin suspension were also studied for their anti-inflammatory and antinociceptive activities. The results showed that oral administration of nanoemulsion and nano multiple emulsion containing aspirin (60 mg/kg) significantly reduced paw edema induced by λ-carrageenan injection. Both nanoformulations decreased the number of abdominal constriction in acetic acid-induced writhing model. Pretreatment with nanoformulations led to a significant increase in reaction time in hot plate assay. Nanoemulsion demonstrated an enhanced anti-inflammatory and analgesic effects compared to reference suspension while nano multiple emulsion exhibited a mild inhibitory effects in the three experimental animal model tests. The results obtained for nano multiple emulsion were relatively lower than reference. However, administration of blank nanoemulsion did not alter the nociceptive response significantly though it showed slight anti-inflammatory effect. These experimental studies suggest that nanoemulsion and nano multiple emulsion produced a pronounced anti-inflammatory and analgesic effects in rats and may be candidates as new nanocarriers for pharmacological NSAIDs in the treatment of inflammatory disorders and alleviating pains.
    Matched MeSH terms: Ultrasonics*
  12. Ismail NA, Shameli K, Wong MM, Teow SY, Chew J, Sukri SNAM
    Mater Sci Eng C Mater Biol Appl, 2019 Nov;104:109899.
    PMID: 31499959 DOI: 10.1016/j.msec.2019.109899
    In this study, a comparative study of effect using honey on copper nanoparticles (Cu-NPs) via simple, environmentally friendly process and inexpensive route was reported. Honey and ascorbic acid act as stabilizing and reducing agents with the assistance of sonochemical method. The products were characterized using UV-visible (UV-vis) spectroscopy, X-Ray Diffraction (XRD), High-Resolution Transmission Electron Microscopy (HRTEM), Field-Emission Scanning Electron Microscopy (FESEM) and Fourier Transform Infrared (FTIR) spectroscopy. The reddish brown colour demonstrated the formation of Cu-NPs and UV-visible proved the plasmon resonance of Cu-NPs. XRD also confirmed a highly pure Cu-NPs obtained with absence of copper oxide in which the structure is crystalline. The spherical size of the Cu-NPs was acquire in the presence of honey which is 3.68 ± 0.78 nm with narrow particle distribution. The antibacterial activity was seen against gram-positive and gram-negative bacteria which are Enterococcus faecalis (E. faecalis) and Escherichia coli (E. coli). At higher concentration of Cu-NPs, they were more effective in killing both bacteria. The Cu-NPs without and with honey exhibited toxicities toward normal and cancerous cells. However, Cu-NPs without honey showed more potent killing activity against normal and cancer cells.
    Matched MeSH terms: Ultrasonics*
  13. Jibril S, Basar N, Sirat HM, Wahab RA, Mahat NA, Nahar L, et al.
    Phytochem Anal, 2019 Jan;30(1):101-109.
    PMID: 30288828 DOI: 10.1002/pca.2795
    INTRODUCTION: Cassia singueana Del. (Fabaceae) is a rare medicinal plant used in the traditional medicine preparations to treat various ailments. The root of C. singueana is a rich source of anthraquinones that possess anticancer, antibacterial and antifungal properties.

    OBJECTIVE: The objective of this study was to develop an ultrasound-assisted extraction (UAE) method for achieving a high extraction yield of anthraquinones using the response surface methodology (RSM), Box-Behnken design (BBD), and a recycling preparative high-performance liquid chromatography (HPLC) protocol for isolation of anthraquinones from C. singueana.

    METHODOLOGY: Optimisation of UAE was performed using the Box-Behnken experimental design. Recycling preparative HPLC was employed to isolate anthraquinones from the root extract of C. singueana.

    RESULTS: The BBD was well-described by a quadratic polynomial model (R2  = 0.9751). The predicted optimal UAE conditions for a high extraction yield were obtained at: extraction time 25.00 min, temperature 50°C and solvent-sample ratio of 10 mL/g. Under the predicted conditions, the experimental value (1.65 ± 0.07%) closely agreed to the predicted yield (1.64%). The obtained crude extract of C. singueana root was subsequently purified to afford eight anthraquinones.

    CONCLUSION: The extraction protocol described here is suitable for large-scale extraction of anthraquinones from plant extracts.

    Matched MeSH terms: Ultrasonics/methods*
  14. Goh T, Abdul Rahim Samsudin, Abdul Ghani Rafek
    A geotechnical study needs to be carried out to determine the engineering parameters of the rock mass at the project site in executing construction projects such as tunnels, dams, highways and buildings. Design and safety factor of the construction are highly dependent on soil and rock engineering parameters which are usually determined by in-situ test such as Standard Penetration Test (SPT) and seismic tests. The SPT test which normally involves drilling and laboratory works always incur high operating cost, while seismic tests on the other hand are fast, cheap, non-destructive and an easy to operate method for rock mass characterization. The spectral analysis of surface waves (SASW) method is an in situ and non-destructive measurement that is rapid and cost effective. The aims of this study were to determine Rock Quality Designation (RQD) value, excavation classification analysis as well as site characterization by using the SASW method. WinSASW 3.1.3 was used for inversion processing of the SASW data to produce shear wave velocity (Vs) versus depth profiles. The profiles were then analyzed and correlated with rock mass engineering geological parameters such as RQD and site characterization as well as excavation classification of rock mass. Twenty (20) SASW tests were conducted on the granitic rock mass and four (4) SASW tests were conducted on a cut hill slope of metasedimentary rocks. RQD values were computed based on shear wave velocities and ultrasonic velocities of intact (fresh) rock. The differences between RQD obtained from SASW method and those from discontinuity survey were found to be less than 10%. Excavation classification for granitic rock mass at JKR Quarry was empirically determined using both SASW and ultrasonic velocities as well as RQD value of the rock mass. Site characterization for metasedimentary rocks mass at Bukit Tampoi was determined based on shear wave velocities from SASW method.
    Matched MeSH terms: Ultrasonics
  15. Sivakumar M, Tang SY, Tan KW
    Ultrason Sonochem, 2014 Nov;21(6):2069-83.
    PMID: 24755340 DOI: 10.1016/j.ultsonch.2014.03.025
    Novel nanoemulsion-based drug delivery systems (DDS) have been proposed as alternative and effective approach for the delivery of various types of poorly water-soluble drugs in the last decade. This nanoformulation strategy significantly improves the cell uptake and bioavailability of numerous hydrophobic drugs by increasing their solubility and dissolution rate, maintaining drug concentration within the therapeutic range by controlling the drug release rate, and reducing systemic side effects by targeting to specific disease site, thus offering a better patient compliance. To date, cavitation technology has emerged to be an energy-efficient and promising technique to generate such nanoscale emulsions encapsulating a variety of highly potent pharmaceutical agents that are water-insoluble. The micro-turbulent implosions of cavitation bubbles tear-off primary giant oily emulsion droplets to nano-scale, spontaneously leading to the formation of highly uniform drug contained nanodroplets. A substantial body of recent literatures in the field of nanoemulsions suggests that cavitation is a facile, cost-reducing yet safer generation tool, remarkably highlighting its industrial commercial viability in the development of designing novel nanocarriers or enhancing the properties of existing pharmaceutical products. In this review, the fundamentals of nanoemulsion and the principles involved in their formation are presented. The underlying mechanisms in the generation of pharmaceutical nanoemulsion under acoustic field as well as the advantages of using cavitation compared to the conventional techniques are also highlighted. This review focuses on recent nanoemulsion-based DDS development and how cavitation through ultrasound and hydrodynamic means is useful to generate the pharmaceutical grade nanoemulsions including the complex double or submicron multiple emulsions.
    Matched MeSH terms: Ultrasonics/methods*
  16. Hazwani A, Sha'Ban M, Azhim A
    Organogenesis, 2019;15(4):120-136.
    PMID: 31495272 DOI: 10.1080/15476278.2019.1656997
    Extracellular matrix (ECM) based bioscaffolds prepared by decellularization has increasingly emerged in tissue engineering application because it has structural, biochemical, and biomechanical cues that have dramatic effects upon cell behaviors. Therefore, we developed a closed sonication decellularization system to prepare ideal bioscaffolds with minimal adverse effects on the ECM. The decellularization was achieved at 170 kHz of ultrasound frequency in 0.1% and 2% Sodium Dodecyl Sulphate (SDS) solution for 10 hours. The immersion treatment as control was performed to compare the decellularization efficiency with our system. Cell removal and ECM structure were determined by histological staining and biochemical assay. Biomechanical properties were investigated by the indentation testing to test the stiffness, a residual force and compression of bioscaffolds. Additionally, in vivo implantation was performed in rat to investigate host tissue response. Compared to native tissues, histological staining and biochemical assay confirm the absence of cellularity with preservation of ECM structure. Moreover, sonication treatment has not affected the stiffness [N/mm] and a residual force [N] of the aortic scaffolds except for compression [%] which 2% SDS significantly decreased compared to native tissues showing higher SDS has a detrimental effect on ECM structure. Finally, minimal inflammatory response was observed after 1 and 5 weeks of implantation. This study reported that the novelty of our developed closed sonication system to prepare ideal bioscaffolds for tissue engineering applications.
    Matched MeSH terms: Ultrasonics
  17. Tan hs, Mohd Radzi Abas, Norhayati Mohd Tahir
    Sains Malaysiana, 2016;45:365-371.
    A study has been carried out to characterize hydrocarbons emitted from the burning of three tropical wood species. The woods were burned to ember and smoke aerosols emitted were sampled using high volume sampler fitted with a pre-cleaned glass fibre filters. Hydrocarbons were extracted using ultrasonic agitation with dichloromethane-methanol (3:1 v/v) as solvent and the extracts obtained were then fractionated on silica-alumina column. Detection and quantification of aliphatic and polycyclic aromatic hydrocarbons (PAHs) compounds were carried out using GC-MS. The results indicated that the major aliphatic hydrocarbons characterized were straight chain n-alkanes in the range of C12-C35 with Cmax in the range of C27-C33. Rhizophora apiculata and Hevea brasiliensis wood smoke exhibited a weak odd to even carbon number predominance with carbon preference index (CPI) values greater than one whereas Melaleuca cajuputi wood smoke aerosols did not exhibit similar pattern with CPI obtained close to one. The results obtained also indicated that burning of these wood resulted in formation of PAHs compounds in their smoke aerosols with predominance of three to four rings PAHs over the two, five and lesser of six rings PAHs. PAH diagnostic ratios calculated except for Flan/(Flan+Py) and Indeno/(Indeno+BgP) were consistent with the ratios suggested for wood combustion source as reported in literatures. In the case of the latter, two diagnostic ratios, the values were generally lower than the range normally reported for wood combustion.
    Matched MeSH terms: Ultrasonics
  18. Umar Hamzah, Ibrahim Komoo
    A survey to characterize seismic and ultrasonic properties of a granite weathering profile have been carried out at a roadcut slope exposure along Kuala Lumpur-Karak highway at kilometres 39.9. The terraced cut slope shows a complete weathering profile beginning from fresh grade I rock to grade VI residual soil. Together with in situ seismic measurement, rock samples have been collected for ultrasonic tests in laboratory. The range of velocities representing grades and indices of weathered rocks and soils are determined from the in situ seismic surveys. The range of ultrasonic velocities and elastic moduli are obtained from the laboratory measurements.
    Satu survei untuk mencirikan sifat seismos dan ultrasonik profil luluhawa granit telah dilakukan di singkapan potongan jalan, cerun utara lebuhraya Kuala Lumpur-Karak pada lokaliti 39.9 km. Potongan berteres ini mempamirkan satu profil luluhawa lengkap iaitu mulai batuan gred 1 yang segar hingga ke tanah baki bergred VI. Di samping pengukuran seismos secara in situ, sampel batuan juga diambil untuk dibuat pengukuran halaju ultrasonik di makmal. Julat halaju yang mewakili gred dan indeks luluhawa bagi tanah dan batuan diperolehi daripada survei seismos in situ. Julat halaju trasonik dan modulus kenyal diperolehi hasil pengukuran di makmal.
    Matched MeSH terms: Ultrasonics
  19. Ling BC, Gillings BR
    Asian J Aesthet Dent, 1995;3:17-21.
    PMID: 9063105
    With the prognosis of dental implant replacement of missing teeth becoming better each year, practitioners are focusing their attention on the aesthetic aspects of implantology. However, improvement in aesthetics is only possible with the improvement in implant technology, surgical techniques and prosthodontic procedures. This study aimed at evaluating the effects of various physical and chemical agents on the implant surface; with the view of obtaining increased surface area and biocompatibility. The study found that the treatment of air-aluminum oxide blasted implants using a mixture of 30% HNO3-5% HF acids produced a surface which meets the consideration of aesthetics for implants placed in the anterior maxillary region.
    Matched MeSH terms: Ultrasonics
  20. Zainol H, Sumithran E
    Histopathology, 1993 Jun;22(6):581-6.
    PMID: 7689070
    This study evaluates the usefulness of a combined cytological and histological approach to the diagnosis of hepatocellular carcinoma (HCC) when applied to fine needle biopsy specimens obtained under ultrasonic guidance. The material, aspirated from 51 focal liver lesions, was handled in such a way that there was sufficient material for both cytological and histological (cell block) assessment. Of the 29 cases of HCC studied, a confident cytological diagnosis was made in 23 (79%). In the remaining six cases, the cytological features were considered to be suspicious but not diagnostic of HCC. Examination of cell blocks in the six cases enabled a confident diagnosis of HCC to be made in all cases. This was due to the supplementary visual information provided by the histological features, particularly the pattern of arrangement of the tumour cells.
    Matched MeSH terms: Ultrasonics
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links