MATERIALS AND METHODS: Sound extracted human molars were randomly divided into: manufacturer's instructions (MI), manual blend 2 mm (MB2), and manual blend 4 mm (MB4). Occlusal enamel was removed and flattened, dentin surfaces were bonded by Prime & Bond universal (Dentsply and Optibond FL, Kerr). For the MI group, adhesives were applied following the manufacturer's instructions then light-cured. For MB groups, SDR flow+ bulk-fill flowable composite resin was applied in 2- or 4-mm increment then manually rubbed by a micro brush for 15 s with uncured dentine bonding agents and the mixture was light-cured. Composite buildup was fabricated incrementally using Ceram.X One, Dentsply nanohybrid composite resin restorative material. After 24-h water storage, the teeth were sectioned to obtain beams of about 0.8 mm2 for 24-h and thermocycled micro-tensile bond strength at 0.5 mm/min crosshead speed. Degree of conversion was evaluated with micro-Raman spectroscopy. Contraction gaps at 24 h after polymerization were evaluated and atomic force microscopy (AFM) nano-indentation processes were undertaken for measuring the hardness across the interface. Depth of resin penetration was studied using a scanning electron microscope (SEM). Bond strength data was expressed using two-way ANOVA followed by Tukey's test. Nanoindentation hardness was separately analyzed using one-way ANOVA.
RESULTS: Factors "storage F = 6.3" and "application F = 30.11" significantly affected the bond strength to dentine. For Optibond FL, no significant difference in nanoleakage was found in MI/MB4 groups between baseline and aged specimens; significant difference in nanoleakage score was observed in MB2 groups. Confocal microscopy analysis showed MB2 Optibond FL and Prime & Bond universal specimens diffusing within the dentine. Contraction gap was significantly reduced in MB2 specimens in both adhesive systems. Degree of conversion (DC) of the MB2 specimens were numerically more compared to MS1 in both adhesive systems.
CONCLUSION: Present study suggests that the new co-blend technique might have a positive effect on bond strengths of etch-and-rinse adhesives to dentine.
Objectives: The main aim of the study was to determine and compare the erosive potential of different fruit juices in frozen/unfrozen forms on primary teeth by studying the calcium dissolution.
Materials and methods: pH of four different juices (pure) - apple, orange, citrus limetta (musumbi) and grapes were determined using a digital pH meter. The titratable acidity of these in frozen and unfrozen forms were determined by adding 0.2 ml of 1M NaOH to these to raise to pH=5.5(critical pH) and pH =7(neutral pH). Forty eight caries free deciduous anterior teeth specimens were prepared to study the calcium dissolution by atomic absorption spectrophotometer. The results were analysed for statistical significance using One-way Repeated Measures ANOVA and pair wise multiple comparison with Bonferroni correction.
Results: Total titratable acidity and calcium dissolution were found to be significantly more in the initial thawed fruit juices.
Conclusion: Frozen fruit juices had more buffering capacity and erosive potential than unfrozen forms. The study concluded that sucking on frozen fruit juices is more damaging to teeth than unfrozen forms because more of erosion is expected to occur in a frozen state.
METHODS: Visible proximal surfaces of extracted human teeth were assessed by ICDAS-II before setting them in five manikin mouth models. Then contacting proximal surfaces in mouth models were assessed by BW and CS. Histological validation with polarized-light microscopy served as a gold standard. Pairwise comparisons were performed on area under the curve (AUC), sensitivity, and specificity of the three methods, and corrected using Bonferroni's method. Sensitivities and specificities were compared using a test of proportions and AUC values were compared using DeLong's method.
RESULTS: The CS presented significantly higher sensitivity (0.933) than ICDAS-II (0.733, P = 0.01) and BW (0.267, P
OBJECTIVES: To evaluate the sensitivity of QLF and OCT in detecting initial dental erosion in vitro.
METHODS: 12 human incisors were embedded in resin except for a window on the buccal surface. Bonding agent was applied to half of the window, creating an exposed and non-exposed area. Baseline measurements were taken with QLF, OCT and surface microhardness. Samples were immersed in orange juice for 60 min and measurements taken stepwise every 10 min. QLF was used to compare the loss of fluorescence between the two areas. The OCT system, OCS1300SS (Thorlabs Ltd.), was used to record the intensity of backscattered light of both areas. Multiple linear regression and paired t test were used to compare the change of the outcome measures.
RESULTS: All 3 instruments demonstrated significant dose responses with the erosive challenge interval (p < 0.05) and a detection threshold of 10 min from baseline. Thereafter, surface microhardness demonstrated significant changes after every 10 min of erosion, QLF at 4 erosive intervals (20, 40, 50 and 60 min) while OCT at only 2 (50 and 60 min).
CONCLUSION: It can be concluded that OCT and QLF were able to detect demineralization after 10 min of erosive challenge and could be used to monitor the progression of demineralization of initial enamel erosion in vitro.