MATERIALS AND METHODS: Sound extracted human molars were randomly divided into: manufacturer's instructions (MI), manual blend 2 mm (MB2), and manual blend 4 mm (MB4). Occlusal enamel was removed and flattened, dentin surfaces were bonded by Prime & Bond universal (Dentsply and Optibond FL, Kerr). For the MI group, adhesives were applied following the manufacturer's instructions then light-cured. For MB groups, SDR flow+ bulk-fill flowable composite resin was applied in 2- or 4-mm increment then manually rubbed by a micro brush for 15 s with uncured dentine bonding agents and the mixture was light-cured. Composite buildup was fabricated incrementally using Ceram.X One, Dentsply nanohybrid composite resin restorative material. After 24-h water storage, the teeth were sectioned to obtain beams of about 0.8 mm2 for 24-h and thermocycled micro-tensile bond strength at 0.5 mm/min crosshead speed. Degree of conversion was evaluated with micro-Raman spectroscopy. Contraction gaps at 24 h after polymerization were evaluated and atomic force microscopy (AFM) nano-indentation processes were undertaken for measuring the hardness across the interface. Depth of resin penetration was studied using a scanning electron microscope (SEM). Bond strength data was expressed using two-way ANOVA followed by Tukey's test. Nanoindentation hardness was separately analyzed using one-way ANOVA.
RESULTS: Factors "storage F = 6.3" and "application F = 30.11" significantly affected the bond strength to dentine. For Optibond FL, no significant difference in nanoleakage was found in MI/MB4 groups between baseline and aged specimens; significant difference in nanoleakage score was observed in MB2 groups. Confocal microscopy analysis showed MB2 Optibond FL and Prime & Bond universal specimens diffusing within the dentine. Contraction gap was significantly reduced in MB2 specimens in both adhesive systems. Degree of conversion (DC) of the MB2 specimens were numerically more compared to MS1 in both adhesive systems.
CONCLUSION: Present study suggests that the new co-blend technique might have a positive effect on bond strengths of etch-and-rinse adhesives to dentine.
OBJECTIVES: To evaluate the sensitivity of QLF and OCT in detecting initial dental erosion in vitro.
METHODS: 12 human incisors were embedded in resin except for a window on the buccal surface. Bonding agent was applied to half of the window, creating an exposed and non-exposed area. Baseline measurements were taken with QLF, OCT and surface microhardness. Samples were immersed in orange juice for 60 min and measurements taken stepwise every 10 min. QLF was used to compare the loss of fluorescence between the two areas. The OCT system, OCS1300SS (Thorlabs Ltd.), was used to record the intensity of backscattered light of both areas. Multiple linear regression and paired t test were used to compare the change of the outcome measures.
RESULTS: All 3 instruments demonstrated significant dose responses with the erosive challenge interval (p < 0.05) and a detection threshold of 10 min from baseline. Thereafter, surface microhardness demonstrated significant changes after every 10 min of erosion, QLF at 4 erosive intervals (20, 40, 50 and 60 min) while OCT at only 2 (50 and 60 min).
CONCLUSION: It can be concluded that OCT and QLF were able to detect demineralization after 10 min of erosive challenge and could be used to monitor the progression of demineralization of initial enamel erosion in vitro.
METHODS: As a preliminary work, water droplets of 1.5 μL were placed on the surfaces of hydroxyapatite (HA) discs of different densities. The water droplet profile was dynamically recorded every second over a period of 10 s using a contact angle meter to determine the relationship between sorptivity and density. To measure and calculate sorptivity on enamel surfaces, varnish was painted on the labial surface of 96 extracted caries-free human teeth, leaving two 1.4 ± 0.1 mm diameter circular exposed test sites. The specimens were randomly divided into 6 groups (n = 16) and subjected to 0(G0), 7(G7), 14(G14), 21(G21), 28(G28) and 35(G35) days of pH cycling, respectively. A 0.7 μL water droplet was placed on each exposed site and Optical Coherence Tomography was used to measure its height every 10 seconds for 2 min. Sorptivity was computed by considering sorption equations and Washburn's analysis of capillary kinetics and correction for evaporation was also performed. Micro-Computed Tomography scans of the specimens were obtained and delta Z (ΔZ) is the parameter used to measure mineral loss. ΔZ at 10 μm (ΔZ10) and 50 μm (ΔZ50) from the surface were calculated. One-way ANOVA and Post-hoc Tukey tests were used to compare sorptivity between groups and bivariate correlations were used to analyze the association between sorptivity and ΔZ.
RESULTS: Sorptivity was found to be inversely and linearly correlated with HA density with R2 value of 0.95. With enamel, there is a general trend of increase in mean sorptivity from G0 to G35, except for a decrease in G21. The same trends were observed for both ΔZ10 and ΔZ50. The decrease in sorptivity in G21 coincided with the presence of a surface hypermineralized layer in G21 samples. Post-hoc Tukey showed significant differences in mean sorptivity between G0 and G14, G0 and G21 as well as G14 and G21. Post-hoc Dunnett's T3 showed significant differences for ΔZ10 between G0 and G14 as well as G14 and G21. Significant correlation between mean sorptivity and ΔZ10 was detected with Pearson correlation coefficient of 0.461. For ΔZ50, post-hoc Tukey showed significant differences between G0 and G14 but no significant difference was detected between G14 and G21. No correlations were detected between mean sorptivity and ΔZ50.
SIGNIFICANCE: Sorptivity was found to be inversely and linearly correlated with HA density with R2 value of 0.95. With enamel, there is a general trend of increase in mean sorptivity from G0 to G35, except for a decrease in G21. The same trends were observed for both ΔZ10 and ΔZ50. The decrease in sorptivity in G21 coincided with the presence of a surface hypermineralized layer in G21 samples.