Displaying publications 1 - 20 of 271 in total

Abstract:
Sort:
  1. Uriarte FA
    Toxicol Ind Health, 1991 Sep-Nov;7(5-6):229-49.
    PMID: 1780863
    Matched MeSH terms: Industrial Waste/adverse effects*
  2. Abdullah AR, Woon WC, Bakar RA
    Bull Environ Contam Toxicol, 1996 Jul;57(1):155-62.
    PMID: 8661474
    Matched MeSH terms: Industrial Waste
  3. Low KS, Lee CK, Lee PL
    Bull Environ Contam Toxicol, 1997 Mar;58(3):380-6.
    PMID: 9008046
    Matched MeSH terms: Industrial Waste
  4. Low KS, Lee CK, Koo WH
    Bull Environ Contam Toxicol, 1999 Apr;62(4):428-33.
    PMID: 10094725
    Matched MeSH terms: Industrial Waste/analysis
  5. Sulaiman S, Pawanchee ZA, Wahab A, Jamal J, Sohadi AR
    J Vector Ecol, 1999 Dec;24(2):154-7.
    PMID: 10672544
    The efficacy of three insecticides, fipronil 3G, lambda-cyhalothrin 10%CS, and sumithion 50EC were evaluated against the dengue vector Aedes albopictus in discarded tires in Kuala Lumpur, Malaysia. The dosage given for each insecticide was 0.01 g of active ingredient/m2. Fipronil 3G was the most effective larvicide with a residual activity of up to two weeks, causing 88% mortality in Aedes albopictus. Lambda-cyhalothrin 10%CS was effective for one week causing 92% larval mortality and two weeks with 63% larval mortality. Sumithion 50EC had a residual efficacy of one week with 79% larval mortality.
    Matched MeSH terms: Industrial Waste
  6. Low KS, Lee CK, Lee CY
    Appl Biochem Biotechnol, 2001 Jan;90(1):75-87.
    PMID: 11257809
    The potential of quaternized wood (QW) chips in removing hexavalent chromium from synthetic solution and chrome waste under both batch and continuous-flow conditions was investigated. Sorption was found to be dependent on pH, metal concentration, and temperature. QW chips provide higher sorption capacity and wider pH range compared with untreated wood chips. The equilibrium data could be fitted into the Langmuir isotherm model, and maximum sorption capacities were calculated to be 27.03 and 25.77 mg/g in synthetic chromate solution and chrome waste, respectively. The presence of sulfate in high concentration appeared to suppress the uptake of chromium by QW chips. Column studies showed that bed depth influenced the breakthrough time greatly whereas flow rate of influent had little effect on its sorption on the column.
    Matched MeSH terms: Industrial Waste*
  7. Haron MJ, Yunus WM
    PMID: 11460327
    A cerium-loaded poly(hydroxamic acid) chelating ion exchanger was used for fluoride ion removal from aqueous solution. The resin was effective in decreasing the fluoride concentration from 5 mM down to 0.001 mM in acidic pH between 3 and 6. The sorption followed a Langmuir model with a maximum capacity of 0.5 mmol/g. The removal is accomplished by an anion exchange mechanism. The rate constant for the sorption was found to be 9.6 x 10(-2) min-1. A column test shows that the fluoride ion was retained on the column until breakthrough point and the fluoride sorbed in the column can be eluted with 0.1 M NaOH. The column can be reused after being condition with hydrochloric acid at pH 4. The resin was tested and found to be effective for removal of fluoride from actual industrial wastewater.
    Matched MeSH terms: Industrial Waste
  8. Onyia CO, Uyu AM, Akunna JC, Norulaini NA, Omar AK
    Water Sci Technol, 2001;44(10):157-62.
    PMID: 11794647
    Malaysia is essentially an agricultural country and her major polluting effluents have been from agro-based industries of which palm oil and rubber industries together contribute about 80% of the industrial pollution. Palm oil sludge, commonly referred to, as palm oil mill effluent (POME) is brown slurry composed of 4-5% solids, mainly organic, 0.5-1% residual oil, and about 95% water. The effluent also contains high concentrations of organic nitrogen. The technique for the treatment of POME is basically biological, consisting of pond systems, where the organic nitrogen is converted to ammonia, which is subsequently transformed to nitrate, in a process called nitrification. A 15-month monitoring program of a pond system (combined anaerobic, facultative, and aerobic ponds in series) confirmed studies by other authors and POME operators that nitrification in a pond system demands relatively long hydraulic retention time (HRT), which is not easily achieved, due to high production capacity of most factories. Bioaugmentation of POME with mixed culture of nitrifiers (ammonia and nitrite oxidizers) has been identified as an effective tool not only for enhancing nitrification of POME but also for improving quality of POME as source of liquid nitrogen fertilizer for use in the agricultural sector, especially in oil palm plantations. Nitrate is readily absorbable by most plants, although some plants are able to absorb nitrogen in the form of ammoniun. In this study, up to 60% reduction in HRT (or up to 20% reduction in potential land requirement) was achieved when bioaugmentation of POME was carried out with the aim of achieving full nitrification.
    Matched MeSH terms: Industrial Waste
  9. Ramasamy P, Periathamby A, Ibrahim S
    Waste Manag Res, 2002 Dec;20(6):536-40.
    PMID: 12549665
    Carbide sludge (10.4-11.5 tonnes day(-1)) is generated from the reaction of calcium carbide (900 kg) and water (6,000 L) in the production of acetylene (2,400 m3), in three selected acetylene manufacturing plants. The sludge (of pH 12.2 and containing Cu, Pb, Fe, Mn, Ni and Zn ions whose concentrations exceed the Department of Environment limits for industrial wastewater) was treated by vacuum filtration as a substitute for the ponding system, which is environmentally less acceptable. A similar system by flocculation was also developed. The filtration system represents an improvement over the ponding method, as shown by a pH of 7 for the clear filtrate; the solid cake, which contains 98% of the metals, can be conveniently disposed at an integrated scheduled waste treatment centre.
    Matched MeSH terms: Industrial Waste
  10. Ujang Z, Wong CL, Manan ZA
    Water Sci Technol, 2002;46(11-12):77-84.
    PMID: 12523736
    Industrial wastewater minimization can be conducted using four main strategies: (i) reuse; (ii) regeneration-reuse; (iii) regeneration-recycling; and (iv) process changes. This study is concerned with (i) and (ii) to investigate the most suitable approach to wastewater minimization for an old textile industry plant. A systematic water networks design using water pinch analysis (WPA) was developed to minimize the water usage and wastewater generation for the textile plant. COD was chosen as the main parameter. An integrated design method has been applied, which brings the engineering insight using WPA that can determine the minimum flowrate of the water usage and then minimize the water consumption and wastewater generation as well. The overall result of this study shows that WPA has been effectively applied using both reuse and regeneration-reuse strategies for the old textile industry plant, and reduced the operating cost by 16% and 50% respectively.
    Matched MeSH terms: Industrial Waste
  11. Noor MJ, Muyibi SA, Ahmed T, Ghazall AH, Jusoh A, Idris A, et al.
    Water Sci Technol, 2002;46(9):331-8.
    PMID: 12448486
    A laboratory study was conducted on an Extended Aeration-Microfiltration (EAM) reactor in treating a food industry wastewater. The reactor contained horizontally laid hollow fibre microfiltration (MF) units that were fully submerged. The MF units were connected to a peristaltic pump that was used to extract permeate continuously under suction pressure. Continuous aeration from beneath the modules provided the crossflow effect to the MF units. Active activated sludge was used in the start-up where the sludge was mixed together with the feed water at a Food/Microorganisms (F/M) value of about 0.1. Primary effluent with Chemical Oxygen Demand (COD) values ranged between 1,500 and 3,000 mg/l was used as feed water. The EAM reactor was operated for nearly three months without initiating cleaning of the MF units. A suction pressure of 0.9 bar and Mixed Liquor Suspended Solids (MLSS) of over 5,500 mg/l were reached when nearing the end of the three month operation period. Permeate COD and turbidity reduction of over 97% and 99% respectively, were achieved. Prior to this, the MF module arrangements were studied; where vertically arranged modules were found to perform poorly as compared to the horizontally laid modules, in terms of clean water permeate flux.
    Matched MeSH terms: Industrial Waste*
  12. Low KS, Lee CK, Lee TS
    Environ Technol, 2003 Feb;24(2):197-204.
    PMID: 12675017
    Spent bleaching earth, an industrial waste produced after the bleaching of crude palm oil, was investigated for its potential in removing Cr(VI) from aqueous solution. The earth was treated with different amounts of sulfuric acid and under different activation temperatures. Results show that the optimum treatment process involved 10% sulfuric acid at 350 degrees C. The effects of contact time, pH, initial concentration, sorbent dosage, temperature, sorption isotherms and the presence of other anions on its sorption capacity were studied. Isotherm data could be fitted into a modified Langmuir isotherm model implying monolayer coverage of Cr(VI) on acid activated spent bleaching earth. The maximum sorption capacity derived from the Langmuir isotherm was 21.2 mg g(-1). This value was compared with those of some other low cost sorbents. Studies of anion effect on the uptake of Cr(VI) on acid activated spent bleaching earth provided the following order of suppression: EDTA >PO4(3-)>SO4(2-)>NO3(-)>Cl(-).
    Matched MeSH terms: Industrial Waste*
  13. Omar M, Ali HM, Abu MP, Kontol KM, Ahmad Z, Ahmad SH, et al.
    Appl Radiat Isot, 2004 May;60(5):779-82.
    PMID: 15082059
    Radium concentrations in 470 samples of the various types of waste from oil and gas industries were analysed using gamma spectrometers. The results showed that the radium concentration varied within a wide range. The highest mean 226Ra and 228Ra concentrations of 114,300 and 130,120 Bq/kg, respectively, were measured in scales. Overall, 75% of the waste, mostly sludge and extraction residue lies within the normal range of radium concentration in soils of Malaysia. However, some platform sludge can have radium concentration up to 560 Bq/kg.
    Matched MeSH terms: Industrial Waste*
  14. Azad SA, Vikineswary S, Chong VC, Ramachandran KB
    Lett Appl Microbiol, 2004;38(1):13-8.
    PMID: 14687209
    Rhodovulum sulfidophilum was grown in settled undiluted and nonsterilized sardine processing wastewater (SPW). The aims were to evaluate the effects of inoculum size and media on the biomass production with simultaneous reduction of chemical oxygen demand (COD).
    Matched MeSH terms: Industrial Waste
  15. Ahmad AL, Ismail S, Bhatia S
    Environ Sci Technol, 2005 Apr 15;39(8):2828-34.
    PMID: 15884382
    The coagulation-flocculation process incorporated with membrane separation technology will become a new approach for palm oil mill effluent (POME) treatment as well as water reclamation and reuse. In our current research, a membrane pilot plant has been used for POME treatment where the coagulation-flocculation process plays an important role as a pretreatment process for the mitigation of membrane fouling problems. The pretreated POME with low turbidity values and high water recovery are the main objectives to be achieved through the coagulation-flocculation process. Therefore, treatment optimization to serve these purposes was performed using jar tests and applying a response surface methodology (RSM) to the results. A 2(3) full-factorial central composite design (CCD) was chosen to explain the effect and interaction of three factors: coagulant dosage, flocculent dosage, and pH. The CCD is successfully demonstrated to efficiently determine the optimized parameters, where 78% of water recovery with a 20 NTU turbidity value can be obtained at the optimum value of coagulant dosage, flocculent dosage, and pH at 15 000 mg/L, 300 mg/L, and 6, respectively.
    Matched MeSH terms: Industrial Waste*
  16. Yacob S, Hassan MA, Shirai Y, Wakisaka M, Subash S
    Chemosphere, 2005 Jun;59(11):1575-81.
    PMID: 15894045
    Anthropogenic release of greenhouse gases, especially CO2 and CH4 has been recognized as one of the main causes of global warming. Several measures under the Kyoto Protocol 1997 have been drawn up to reduce the greenhouse gases emission. One of the measures is Clean Development Mechanisms (CDM) that was created to enable developed countries to cooperate with developing countries in emission reduction activities. In Malaysia, palm oil industry particularly from palm oil mill effluent (POME) anaerobic treatment has been identified as an important source of CH4. However, there is no study to quantify the actual CH4 emission from the commercial scale wastewater treatment facility. Hence, this paper shall address the CH4 emission from the open digesting tanks in Felda Serting Hilir Palm Oil Mill. CH4 emission pattern was recorded for 52 weeks from 3600 m3 open digesting tanks. The findings indicated that the CH4 content was between 13.5% and 49.0% which was lower than the value of 65% reported earlier. The biogas flow rate ranged between 0.8l min(-1)m(-2) and 9.8l min(-1)m(-2). Total CH4 emission per open digesting tank was 518.9 kgday(-1). Relationships between CH4 emission and total carbon removal and POME discharged were also discussed. Fluctuation of biogas production was observed throughout the studies as a result of seasonal oil palm cropping, mill activities, variation of POME quality and quantity discharged from the mill. Thus only through long-term field measurement CH4 emission can be accurately estimated.
    Matched MeSH terms: Industrial Waste
  17. Zulkali MM, Ahmad AL, Norulakmal NH
    Bioresour Technol, 2006 Jan;97(1):21-5.
    PMID: 15963716
    The effects of initial concentration of lead, temperature, biomass loading and pH were investigated for an optimized condition of lead uptake from the aqueous solution. The optimization process was analyzed using Central Composite Face-Centered Experimental Design in Response Surface Methodology (RSM) by Design Expert Version 5.0.7 (StatEase, USA). The design was employed to derive a statistical model for the effect of parameters studied on the removal of lead ion from aqueous solution. The coefficient of determination, R2 was found to be 92.36%. The initial concentration of 50.0 mg/L, temperature of 60 degrees C, biomass loading of 0.2 g and pH of 5.0 had been found to be the optimum conditions for the maximum uptake of lead ions in 98.11% batch mode. Under the optimum conditions, the lead uptake was attained to be circa 8.60 mg/g.
    Matched MeSH terms: Industrial Waste*
  18. Choo TP, Lee CK, Low KS, Hishamuddin O
    Chemosphere, 2006 Feb;62(6):961-7.
    PMID: 16081131
    This study describes an investigation using tropical water lilies (Nymphaea spontanea) to remove hexavalent chromium from aqueous solutions and electroplating waste. The results show that water lilies are capable of accumulating substantial amount of Cr(VI), up to 2.119 mg g(-1) from a 10 mg l(-1) solution. The roots of the plant accumulated the highest amount of Cr(VI) followed by leaves and petioles, indicating that roots play an important role in the bioremediation process. The maturity of the plant exerts a great effect on the removal and accumulation of Cr(VI). Plants of 9 weeks old accumulated the most Cr(VI) followed by those of 6 and 3 weeks old. The results also show that removal of Cr(VI) by water lilies is more efficient when the metal is present singly than in the presence of Cu(II) or in waste solution. This may be largely associated with more pronounced phytotoxicity effect on the biochemical changes in the plants and saturation of binding sites. Significant toxicity effect on the plant was evident as shown in the reduction of chlorophyll, protein and sugar contents in plants exposed to Cr(VI) in this investigation.
    Matched MeSH terms: Industrial Waste
  19. Kathuria V
    J Environ Manage, 2006 Mar;78(4):405-26.
    PMID: 16171929
    The policy prescription for solving environmental problems of developing countries and countries-in-transition (CIT) is slowly getting polarized into two viewpoints. One group of researchers and policy advocates including multilateral organizations upholds extensive use of market based instruments (MBIs) in these countries. The other group argues that institutions need to be built first or the policy makers should select the incremental or tiered approach taking into account the existing capabilities. The group also insists that the financial, institutional and political constraints make environmental regulation in these countries more problematic than in industrialized countries. In the short-run, the immediate needs of the developing countries can be addressed effectively by learning lessons from the difficulties encountered by a few successful cases and accordingly evolving an appropriate policy instrument. In this paper an attempt has been made to highlight three such cases from three different parts of the world--Malaysia (Asia-pacific), Poland (Eastern Europe) and Colombia (Latin America). The paper looks into what policy instruments led to a fall in water pollution levels in these countries and what role did MBIs play in this pollution mitigation? The case studies suggest that it is a combination of instruments--license fee, standards, charge and subsidies--reinforced by active enforcement that led to an overall improvement in environment compliance.
    Matched MeSH terms: Industrial Waste
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links