DESIGN AND METHODS: A cross-sectional survey was conducted in two hospitals in Jordan among 310 parents of infants in the NICU by using PSS: NICU and PROMIS.
RESULTS: Both parents experienced high levels of stress, anxiety, depression and sleep disturbance. There was a significant difference in stress level between mothers and fathers [t (308)=3.471, p=0.001], with the mothers experiencing higher stress than the fathers [mean: mothers=108.58; fathers=101.68]. The highest and lowest sources of stress were infant behavior and appearance (M=4.09) and sights and sounds in the NICU (M=3.54), respectively. The correlation between stress levels with anxiety (r=0.79) and depression (r=0.75) was strong and positive while sleep disturbance was significant and moderate (r=0.43).
CONCLUSIONS: The mothers experienced higher levels of stress compared to fathers, with positive correlations between stress and anxiety, depression and sleep disturbance.
PRACTICAL IMPLICATIONS: The findings of this study create nursing awareness of parent stress and its impact, which will help them to improve nursing care for parents.
DATA SOURCES: The articles published in PubMed, MEDLINE and Google Scholar were searched using text words: off-label, unlicensed, paediatric and children. Additional articles were identified by reviewing the bibliography of the retrieved articles. Full-text articles published in English which reported on the prevalence of off-label prescribing in children between January 1996 and December 2016 were included.
RESULTS: A total of 101 studies met the inclusion criteria. Off-label prescribing definition included four main categories: age, indication, dose and route of administration. The three most common reference sources used in the studies were summary of product characteristics, national formularies and package inserts. Overall, the off-label prescribing rates in children ranged from 1.2 to 99.7%. The most common category of off-label prescribing in children was dose and age.
CONCLUSIONS: This review highlighted that off-label prescribing in children was found to be highly prevalent throughout the past two decades, persistently in the neonatal intensive care units. This suggests that besides legislative and regulatory initiatives, behavioural, knowledge aspects and efforts to integrate evidence into practice related to off-label prescribing also need to be evaluated and consolidated as part of the concerted efforts to narrow the gaps in prescribing for children.
OBJECTIVES: This study aimed to determine EnCPAP rates in 36 neonatal intensive care units of the Malaysian National Neonatal Registry (MNNR) in 2013, to compare the outcomes of VLBW neonates with and without EnCPAP, and to determine whether the availability of CPAP facilities and unit policies played a significant role in EnCPAP rates.
METHODS: First, a retrospective cohort study was conducted of VLBW neonates born in the hospitals participating in the study without major congenital abnormalities in the MNNR. This was followed by a questionnaire survey of these hospitals focussed on CPAP facilities and unit policies.
RESULTS: Of the 2,823 neonates, 963 (34.1%) received EnCPAP. Amongst EnCPAP neonates significantly fewer deaths were recorded (10.9 vs. 21.7%; p < 0.001), less bronchopulmonary dysplasia was observed (BPD; 8.0 vs. 11.7%; p = 0.002) and fewer mechanical ventilation days were necessary (p < 0.001) than in non-EnCPAP neonates. Logistic regression analysis showed that EnCPAP was significantly associated with a lower mortality (adjusted OR 0.623; 95% CI 0.472, 0.824; p = 0.001) and BPD among survivors (adjusted OR 0.585; 95% CI 0.427, 0.802; p = 0.001). The median EnCPAP rate of the 36 hospitals was 28.4% (IQR 14.3-38.7). Hospitals with CPAP facilities in the delivery suites (p = 0.001) and during transport (p = 0.001) and a policy for EnCPAP (p = 0.036) had significantly higher EnCPAP rates.
CONCLUSION: EnCPAP reduced mortality and BPD in Malaysian VLBW neonates. Resource-strapped developing countries should prioritise the use of this low-cost therapy.
CONCLUSION: Exposing preterm infants to either 12 h cyglical lighting or continuously dim environment did not have any significant effect on their weight gain during the neonatal period.
STUDY DESIGN: Retrospective cohort study using data submitted prospectively to the Malaysian National Neonatal Registry (MNNR).
SETTING: 44 Malaysian NICUs.
PARTICIPANTS: All neonates born in 2015- 2020.
RESULTS: EOS was reported in 991 neonates. The annual incidence of EOS increased from 0.46 to 0.49/1000 livebirths over the six years. The most common pathogen was Streptococcus agalactiae or Group B haemolytic streptococcus (GBS) (n=388, 39.2%), followed by Escherichia coli (E. coli) (n=80, 8.1%), Klebsiella spp (n=73, 7.4%), coagulase negative staphylococcus (CONS) (n=73, 7.4%), Pseudomonas spp (n=44, 4.4%) and methicillin-sensitive Staphylococcus aureus (n=34, 3.4%). The incidence of EOS due to GBS increased from 0.17 to 0.22/1000 livebirths. Morbidities and mortality were higher in those with EOS than without EOS. Multiple logistic regression analysis showed that Indian ethnic group, chorioamnionitis, gestation≥37weeks, female, spontaneous vaginal delivery, instrumental delivery, and surfactant therapy were significantly associated with increased risk of EOS due to GBS. Four factors were significantly associated with increased risk of non-GBS EOS (outborns, birthweight lt;1000 g, vaginal delivery, and surfactant therapy). Early continuous positive airway pressure was associated with significantly lower risk of EOS.
CONCLUSION: The incidence of EOS showed an increasing trend in Malaysian NICUs. GBS was the most common causative pathogen. Several modifiable risk factors associated with EOS have been identified.