Displaying publications 1 - 20 of 41 in total

Abstract:
Sort:
  1. Issa R, Mohd Hassan NA, Abdul H, Hashim SH, Seradja VH, Abdul Sani A
    Diagn Microbiol Infect Dis, 2012 Jan;72(1):62-7.
    PMID: 22078904 DOI: 10.1016/j.diagmicrobio.2011.09.021
    A real-time quantitative polymerase chain reaction (qPCR) was developed for detection and discrimination of Mycobacterium tuberculosis (H37Rv and H37Ra) and M. bovis bacillus Calmette-Guérin (BCG) of the Mycobacterium tuberculosis complex (MTBC) from mycobacterial other than tuberculosis (MOTT). It was based on the melting curve (Tm) analysis of the gyrB gene using SYBR(®) Green I detection dye and the LightCycler 1.5 system. The optimal conditions for the assay were 0.25 μmol/L of primers with 3.1 mmol/L of MgCl(2) and 45 cycles of amplification. For M. tuberculosis (H37Rv and H37Ra) and M. bovis BCG of the MTBC, we detected the crossing points (Cp) at cycles of 16.96 ± 0.07, 18.02 ± 0.14, and 18.62 ± 0.09, respectively, while the Tm values were 90.19 ± 0.06 °C, 90.27 ± 0.09 °C, and 89.81 ± 0.04 °C, respectively. The assay was sensitive and rapid with a detection limit of 10 pg of the DNA template within 35 min. In this study, the Tm analysis of the qPCR assay was applied for the detection and discrimination of MTBC from MOTT.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  2. Teoh BT, Sam SS, Tan KK, Johari J, Abd-Jamil J, Hooi PS, et al.
    Sci Rep, 2016 06 09;6:27663.
    PMID: 27278716 DOI: 10.1038/srep27663
    Timely and accurate dengue diagnosis is important for differential diagnosis and immediate implementation of appropriate disease control measures. In this study, we compared the usefulness and applicability of NS1 RDT (NS1 Ag Strip) and qRT-PCR tests in complementing the IgM ELISA for dengue diagnosis on single serum specimen (n = 375). The NS1 Ag Strip and qRT-PCR showed a fair concordance (κ = 0.207, p = 0.001). While the NS1 Ag Strip showed higher positivity than qRT-PCR for acute (97.8% vs. 84.8%) and post-acute samples (94.8% vs. 71.8%) of primary infection, qRT-PCR showed higher positivity for acute (58.1% vs. 48.4%) and post-acute (50.0% vs.41.4%) samples in secondary infection. IgM ELISA showed higher positivity in samples from secondary dengue (74.2-94.8%) than in those from primary dengue (21.7-64.1%). More primary dengue samples showed positive with combined NS1 Ag Strip/IgM ELISA (99.0% vs. 92.8%) whereas more secondary samples showed positive with combined qRT-PCR/IgM ELISA (99.4% vs. 96.2%). Combined NS1 Ag Strip/IgM ELISA is a suitable combination tests for timely and accurate dengue diagnosis on single serum specimen. If complemented with qRT-PCR, combined NS1 Ag Strip/IgM ELISA would improve detection of secondary dengue samples.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  3. Teoh BT, Chin KL, Samsudin NI, Loong SK, Sam SS, Tan KK, et al.
    BMC Infect Dis, 2020 Dec 11;20(1):947.
    PMID: 33308203 DOI: 10.1186/s12879-020-05585-4
    BACKGROUND: Early detection of Zika virus (ZIKV) infection during the viremia and viruria facilitates proper patient management and mosquito control measurement to prevent disease spread. Therefore, a cost-effective nucleic acid detection method for the diagnosis of ZIKV infection, especially in resource-deficient settings, is highly required.

    METHODS: In the present study, a single-tube reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the detection of both the Asian and African-lineage ZIKV. The detection limit, strain coverage and cross-reactivity of the ZIKV RT-LAMP assay was evaluated. The sensitivity and specificity of the RT-LAMP were also evaluated using a total of 24 simulated clinical samples. The ZIKV quantitative reverse transcription-polymerase chain reaction (qRT-PCR) assay was used as the reference assay.

    RESULTS: The detection limit of the RT-LAMP assay was 3.73 ZIKV RNA copies (probit analysis, P ≤ 0.05). The RT-LAMP assay detected the ZIKV genomes of both the Asian and African lineages without cross-reacting with other arthropod-borne viruses. The sensitivity and specificity of the RT-LAMP assay were 90% (95% CI = 59.6-98.2) and 100% (95% CI = 78.5-100.0), respectively. The RT-LAMP assay detected ZIKV genome in 9 of 24 (37.5%) of the simulated clinical samples compared to 10 of 24 (41.7%) by qRT-PCR assay with a high level of concordance (κ = 0.913, P 

    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  4. Teoh BT, Sam SS, Tan KK, Danlami MB, Shu MH, Johari J, et al.
    J Clin Microbiol, 2015 Mar;53(3):830-7.
    PMID: 25568438 DOI: 10.1128/JCM.02648-14
    A method for the rapid diagnosis of early dengue virus (DENV) infection is highly needed. Here, a prototype reverse transcription-recombinase polymerase amplification (RT-RPA) assay was developed. The assay detected DENV RNA in <20 min without the need for thermocycling amplification. The assay enabled the detection of as few as 10 copies of DENV RNA. The designed RT-RPA primers and exo probe detected the DENV genome of at least 12 genotypes of DENV circulating globally without cross-reacting with other arboviruses. We assessed the diagnostic performance of the RT-RPA assay for the detection of DENV RNA in 203 serum samples of patients with clinically suspected dengue. The sera were simultaneously tested for DENV using a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay, quantitative RT-PCR (qRT-PCR), and IgM- and IgG-capture enzyme-linked immunosorbent assays (ELISA). Acute DENV infection was confirmed in 130 samples and 61 of the samples (46.9%) were classified as viremic with qRT-PCR. The RT-RPA assay showed good concordance (κ of ≥0.723) with the RT-LAMP and qRT-PCR assays in detecting the dengue viremic samples. When used in combination with ELISA, both the RT-RPA and RT-LAMP assays increased the detection of acute DENV infection to ≥95.7% (≥45/47) in samples obtained within 5 days of illness. The results from the study suggest that the RT-RPA assay is the most rapid molecular diagnostic tool available for the detection of DENV. Hence, it is possible to use the RT-RPA assay in a laboratory to complement routine serology testing for dengue.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  5. Mohamed Zahidi J, Bee Yong T, Hashim R, Mohd Noor A, Hamzah SH, Ahmad N
    Diagn Microbiol Infect Dis, 2015 Apr;81(4):227-33.
    PMID: 25641125 DOI: 10.1016/j.diagmicrobio.2014.12.012
    Molecular approaches have been investigated to overcome difficulties in identification and differentiation of Brucella spp. using conventional phenotypic methods. In this study, high-resolution melt (HRM) analysis was used for rapid identification and differentiation of members of Brucella genus. A total of 41 Brucella spp. isolates from human brucellosis were subjected to HRM analysis using 4 sets of primers, which identified 40 isolates as Brucella melitensis and 1 as Brucella canis. The technique utilized low DNA concentration and was highly reproducible. The assay is shown to be a useful diagnostic tool, which can rapidly differentiate Brucella up to species level.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  6. Lee SV, Tai ES, Mutalib AR, Khairani-Bejo S, Bahaman AR
    Trop Biomed, 2011 Dec;28(3):497-505.
    PMID: 22433877 MyJurnal
    A simple and reliable tool for the early diagnosis of leptospirosis is urgently needed. We report the development of a lyophilized reagent-based polymerase chain reaction (PCR) assay targeting lipL32 gene, which is present only in pathogenic leptospires. To determine the effectiveness of the newly developed assay in the early diagnosis of leptospirosis, the sensitivity and specificity was evaluated. In simulated clinical samples, the assay was able to detect 10² and 10³ leptospires/ml in spiked urine and blood samples, respectively. In experimentally infected animals, leptospiral DNA could be detected in blood and lung samples as early as Day 1 post infection. This assay was also shown to be stable and remained sensitive for up to five months at ambient temperature. Hence, this lyophilized reagent-based PCR assay with high specificity, sensitivity and stability would provide a simple, rapid and reliable method in diagnosing acute leptospirosis, especially in the field of veterinary medicine.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  7. Vythalingam LM, Hossain MAM, Bhassu S
    Mol Cell Probes, 2021 02;55:101683.
    PMID: 33259896 DOI: 10.1016/j.mcp.2020.101683
    Invasive alien fish species have become a silent treat towards the ecosystem especially the native fish population in Malaysia. There has been a need to develop rapid identification methods that can aid management teams in identifying fish species that are not native to our ecosystem. Current visual identification methods are highly tedious and require time, delaying action towards curbing the invasion. The LAMP assay successfully identified six popular invasive fish species in Malaysia. None of the LAMP assays showed false positives and the Limit of Detection of the LAMP primers were highly sensitive and could detect DNA samples up to 1 × 10-15 ng/μl. The LAMP primers designed were highly specific to the target species and did not amplify non target species. DNA sequencing was done to ensure the accuracy of LAMP assay results. This study demonstrates that LAMP is a suitable tool in species identification efforts of invasive fish species in Malaysia.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  8. Lau YL, Fong MY, Mahmud R, Chang PY, Palaeya V, Cheong FW, et al.
    Malar J, 2011;10:197.
    PMID: 21774805 DOI: 10.1186/1475-2875-10-197
    The emergence of Plasmodium knowlesi in humans, which is in many cases misdiagnosed by microscopy as Plasmodium malariae due to the morphological similarity has contributed to the needs of detection and differentiation of malaria parasites. At present, nested PCR targeted on Plasmodium ssrRNA genes has been described as the most sensitive and specific method for Plasmodium detection. However, this method is costly and requires trained personnel for its implementation. Loop-mediated isothermal amplification (LAMP), a novel nucleic acid amplification method was developed for the clinical detection of P. knowlesi. The sensitivity and specificity of LAMP was evaluated in comparison to the results obtained via microscopic examination and nested PCR.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  9. Thong KL, Teh CS, Chua KH
    Trop Biomed, 2014 Dec;31(4):689-97.
    PMID: 25776594 MyJurnal
    The present study aims to develop a system which consists of four pairs of primers that specifically detects Salmonella spp., Salmonella serovar Typhi and Salmonella serovar Paratyphi A with an internal amplification control. The system, when applied in Polymerase Chain Reaction (PCR) under specific conditions, reaction mixture and cycling temperatures produced four bands; 784 bp, 496 bp, 332 bp and 187 bp. The DNA band 784 bp is present in all Salmonella spp., while the bands of 496 bp and 332 bp are only present in S. Paratyphi A and S. Typhi, respectively. An internal amplification control as indicated by the 187 bp shows the system is working in optimum condition in all the tests. This multiplex PCR was evaluated on 241 bacterial cultures and 691 naturally contaminated samples. Overall, this multiplex PCR detection system provides a single step for simultaneous detection of DNAs of Salmonella spp., S. Typhi and S. Paratyphi A.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  10. Chew CH, Lim YA, Lee PC, Mahmud R, Chua KH
    J Clin Microbiol, 2012 Dec;50(12):4012-9.
    PMID: 23035191 DOI: 10.1128/JCM.06454-11
    Malaria remains one of the major killers of humankind and persists to threaten the lives of more than one-third of the world's population. Given that human malaria can now be caused by five species of Plasmodium, i.e., Plasmodium falciparum, Plasmodium vivax, Plasmodium malariae, Plasmodium ovale, and the recently included Plasmodium knowlesi, there is a critical need not only to augment global health efforts in malaria control but also, more importantly, to develop a rapid, accurate, species-sensitive/species-specific, and economically effective diagnostic method for malaria caused by these five species. Therefore, in the present study, a straightforward single-step hexaplex PCR system targeting five human Plasmodium 18S small-subunit rRNAs (ssu rRNAs) was designed, and the system successfully detected all five human malaria parasites. In addition, this system enables the differentiation of single infection as well as mixed infections up to the two-species level. This assay was validated with 50 randomly blinded test and 184 clinical samples suspected to indicate malaria. This hexaplex PCR system is not only an ideal alternative for routine malaria diagnosis in laboratories with conventional PCR machines but also adds value to diagnoses when there is a lack of an experienced microscopist or/and when the parasite morphology is confusing. Indeed, this system will definitely enhance the accuracy and accelerate the speed in the diagnosis of malaria, as well as improve the efficacy of malaria treatment and control, in addition to providing reliable data from epidemiological surveillance studies.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  11. Altay-Kocak A, Bozdayi G, Michel J, Polat M, Kanik-Yuksek S, Tezer H, et al.
    J Infect Dev Ctries, 2020 06 30;14(6):572-579.
    PMID: 32683347 DOI: 10.3855/jidc.12327
    INTRODUCTION: In an attempt to identify a wide spectrum of viral infections, cerebrospinal fluid (CSF) specimens were collected from pediatric cases with the preliminary diagnosis of viral encephalitis/meningoencephalitis in two reference hospitals, from October 2011 to December 2015.

    METHODOLOGY: A combination of nucleic acid-based assays, including in house generic polymerase chain reaction (PCR) assays for enteroviruses, flaviviruses and phleboviruses, a commercial real-time PCR assay for herpesviruses and a commercial real time multiplex PCR, enabling detection of frequently-observed viral, bacterial and fungal agents were employed for screening.

    RESULTS: The microbial agent could be characterized in 10 (10%) of the 100 specimens. Viral etiology could be demonstrated in 7 (70%) specimens, which comprises Human Herpesvirus 6 (4/7), Herpes Simplex virus type1 (2/7) and Enteroviruses (1/7). In 3 specimens (30%), Streptococcus pneumoniae, Listeria monocytogenes and Staphylococcus aureus were detected via the multiplex PCR, which were also isolated in bacteriological media. All specimens with detectable viral nucleic acids, as well as unreactive specimens via nucleic acid testing remained negative in bacteriological cultures.

    CONCLUSIONS: Herpes and enteroviruses were identified as the primary causative agents of central nervous system infections in children. Enterovirus testing must be included in the diagnostic work-up of relevant cases.

    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  12. Fani M, Rezayi M, Meshkat Z, Rezaee SA, Makvandi M, Abouzari-Lotf E, et al.
    J Cell Physiol, 2019 08;234(8):12433-12441.
    PMID: 30633358 DOI: 10.1002/jcp.28087
    BACKGROUND: Human T-lymphotropic virus Type 1 (HTLV-1) is a retrovirus that is endemic in some regions of the world. It is known to cause several diseases like adult T-cell leukemia (ATL) and HTLV-1-associated myelopathy/tropical spastic paraparesis (HAM/TSP). Serology and molecular methods have been used to detect this virus. Of these, enzyme-linked immunosorbent assay (ELISA) is used as a primary screening method and this is usually followed by western blotting (WB) and polymerase chain reaction (PCR) methods as confirmatory tests. We conducted a systematic review of the different techniques used in the diagnosis of HTLV-1 infection.

    MATERIALS AND METHODS: Our search was limited to original papers in the English language from 2010 to 2018 using several databases including Pubmed, Scopus, Google Scholar, Iranmedex, and Scientific Information Database. A manual search of references provided in the included papers was also performed.

    RESULTS: Of 101 electronically searched citations, 43 met the inclusion criteria. ELISA is commonly used for qualitative and screening detection, and WB and PCR techniques are used to confirm infection.

    CONCLUSION: Among all the reported methods for detection of HTLV-1, only serological and molecular tests are used as the most common technical assays for HTLV-1. The ELISA assay, without a confirmatory test, has several limitations and affect the accuracy of the results. Owing to the prevalence of HTLV-1 and limitations of the current detection methods, further evaluation of the accuracy of these methods is needed. There are new opportunities for applying novel technological advances in microfluidics, biosensors, and lab-on-a-chip systems to perform HTLV-1 diagnostics.

    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  13. Yap NJ, Koehler AV, Ebner J, Tan TK, Lim YA, Gasser RB
    Mol Cell Probes, 2016 Feb;30(1):39-43.
    PMID: 26775614 DOI: 10.1016/j.mcp.2016.01.002
    Despite the importance of the cattle industry in Malaysia, there are very few studies of the diversity and public health significance of bovine cryptosporidiosis in this country. In the present study, we used a PCR-based approach to detect and genetically characterize Cryptosporidium DNA in faecal samples from a cohort of 215 asymptomatic cattle (of different ages) from six farms from five states of Peninsular Malaysia. Cattle on four of the six farms were test-positive for Cryptosporidium, with an overall prevalence of 3.2%. Cryptosporidium bovis and Cryptosporidium ryanae were detected in two (0.9%) and five (2.3%) samples tested; this low prevalence likely relates to the age of the cattle tested, as most (73%) of the samples tested originated from cattle that were ≥2 years of age. Future studies should investigate the zoonotic potential of Cryptosporidium in pre-weaned and weaned calves in rural communities of Malaysia.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods
  14. Lau YL, Ismail IB, Izati Binti Mustapa N, Lai MY, Tuan Soh TS, Hassan AH, et al.
    Am J Trop Med Hyg, 2020 Dec;103(6):2350-2352.
    PMID: 33098286 DOI: 10.4269/ajtmh.20-1079
    A simple and rapid reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the detection of SARS-CoV-2. The RT-LAMP assay was highly specific for SARS-CoV-2 and was able to detect one copy of transcribed SARS-CoV-2 RNA within 24 minutes. Assay validation performed using 50 positive and 32 negative clinical samples showed 100% sensitivity and specificity. The RT-LAMP would be valuable for clinical diagnosis and epidemiological surveillance of SARS-CoV-2 infection in resource-limited areas as it does not require the use of sophisticated and costly equipment.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods
  15. Xiu L, Binder RA, Alarja NA, Kochek K, Coleman KK, Than ST, et al.
    J Clin Virol, 2020 07;128:104391.
    PMID: 32403008 DOI: 10.1016/j.jcv.2020.104391
    BACKGROUND: During the past two decades, three novel coronaviruses (CoVs) have emerged to cause international human epidemics with severe morbidity. CoVs have also emerged to cause severe epidemics in animals. A better understanding of the natural hosts and genetic diversity of CoVs are needed to help mitigate these threats.

    OBJECTIVE: To design and evaluate a molecular diagnostic tool for detection and identification of all currently recognized and potentially future emergent CoVs from the Orthocoronavirinae subfamily.

    STUDY DESIGN AND RESULTS: We designed a semi-nested, reverse transcription RT-PCR assay based upon 38 published genome sequences of human and animal CoVs. We evaluated this assay with 14 human and animal CoVs and 11 other non-CoV respiratory viruses. Through sequencing the assay's target amplicon, the assay correctly identified each of the CoVs; no cross-reactivity with 11 common respiratory viruses was observed. The limits of detection ranged from 4 to 4 × 102 copies/reaction, depending on the CoV species tested. To assess the assay's clinical performance, we tested a large panel of previously studied specimens: 192 human respiratory specimens from pneumonia patients, 5 clinical specimens from COVID-19 patients, 81 poultry oral secretion specimens, 109 pig slurry specimens, and 31 aerosol samples from a live bird market. The amplicons of all RT-PCR-positive samples were confirmed by Sanger sequencing. Our assay performed well with all tested specimens across all sample types.

    CONCLUSIONS: This assay can be used for detection and identification of all previously recognized CoVs, including SARS-CoV-2, and potentially any emergent CoVs in the Orthocoronavirinae subfamily.

    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  16. Piera KA, Aziz A, William T, Bell D, González IJ, Barber BE, et al.
    Malar J, 2017 01 13;16(1):29.
    PMID: 28086789 DOI: 10.1186/s12936-016-1676-9
    BACKGROUND: Plasmodium knowlesi is the most common cause of malaria in Malaysia. However, microscopic diagnosis is inaccurate and rapid diagnostic tests (RDTs) are insufficiently sensitive. PCR is sensitive and specific but not feasible at a district level. Loop-mediated isothermal amplification (LAMP) shows potential with only basic requirements. A commercially available LAMP assay, the Eiken Loopamp™ MALARIA Pan Detection kit, is sensitive for Plasmodium falciparum and Plasmodium vivax, but has not previously been evaluated for P. knowlesi. This study aims to determine the sensitivity of this LAMP assay for detecting P. knowlesi infection.

    METHODS: Study participants included 73 uncomplicated malaria patients with PCR species confirmation: 50 P. knowlesi, 20 P. falciparum and 3 P. vivax. Nineteen malaria-negative, non-endemic area controls were also included. The sensitivity of the Eiken Loopamp™ MALARIA Pan Detection kit (Pan LAMP) for detecting each Plasmodium species was evaluated. Sensitivity and specificity of the Eiken Loopamp™ MALARIA Pf Detection kit (Pf LAMP) for P. falciparum were also determined. The limit of detection for each LAMP assay was evaluated, with results compared to PCR. All P. knowlesi patients were also tested by CareStart™ (Pf/VOM) and OptiMAL-IT™ (Pan/Pf) RDTs.

    RESULTS: The sensitivity of the Pan LAMP assay was 100% for P. knowlesi (95% CI 92.9-100), P. falciparum (95% CI 83.2-100), and P. vivax (95% CI 29.2-100). The Pf LAMP was 100% sensitive and specific for P. falciparum detection, with all P. knowlesi samples having a negative reaction. LAMP sensitivity was superior to both RDTs, with only 10 and 28% of P. knowlesi samples testing positive to CareStart™ and OptiMAL-IT™, respectively. Limit of detection using the Pan LAMP for both P. knowlesi and P. vivax was 2 parasites/μL, comparable to PCR. For P. falciparum both the Pan LAMP and Pf LAMP demonstrated a limit of detection of 20 parasites/μL.

    CONCLUSIONS: The Eiken Loopamp™ MALARIA Pan Detection kit is sensitive for detection of P. knowlesi in low parasitaemia clinical infections, as well as P. falciparum and P. vivax. However, a P. knowlesi-specific field assay in a simpler format would assist correct species identification and initiation of optimal treatment for all malaria patients.

    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  17. Boush MA, Djibrine MA, Mussa A, Talib M, Maki A, Mohammed A, et al.
    Sci Rep, 2020 07 30;10(1):12822.
    PMID: 32733079 DOI: 10.1038/s41598-020-69756-8
    In remote areas of malaria-endemic countries, rapid diagnostic tests (RDTs) have dramatically improved parasitological confirmation of suspected malaria cases, especially when skilled microscopists are not available. This study was designed to determine the frequency of Plasmodium falciparum isolates with histidine-rich protein 2 (pfhrp2) gene deletion as one of the possible factors contributing to the failure of PfHRP2-based RDTs in detecting malaria. A total of 300 blood samples were collected from several health centres in Nyala City, Western Sudan. The performance of PfHRP2-based RDTs in relation to microscopy was examined and the PCR-confirmed samples were investigated for the presence of pfhrp2 gene. A total of 113 out of 300 patients were P. falciparum positive by microscopy. Among them, 93.81% (106 out of 113) were positives by the PfHRP2 RDTs. Seven isolates were identified as false negative on the basis of the RDTs results. Only one isolate (0.9%; 1/113) potentially has pfhrp2 gene deletion. The sensitivity and specificity of PfHRP2-based RDTs were 93.81% and 100%, respectively. The results provide insights into the pfhrp2 gene deletion amongst P. falciparum population from Sudan. However, further studies with a large and systematic collection from different geographical settings across the country are needed.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  18. Issa R, Abdul H, Hashim SH, Seradja VH, Shaili N', Hassan NAM
    J Med Microbiol, 2014 Oct;63(Pt 10):1284-1287.
    PMID: 25038139 DOI: 10.1099/jmm.0.072611-0
    A quantitative real-time PCR (qPCR) followed by high resolution melting (HRM) analysis was developed for the differentiation of Mycobacterium species. Rapid differentiation of Mycobacterium species is necessary for the effective diagnosis and management of tuberculosis. In this study, the 16S rRNA gene was tested as the target since this has been identified as a suitable target for the identification of mycobacteria species. During the temperature gradient and primer optimization process, the melting peak (Tm) analysis was determined at a concentration of 50 ng DNA template and 0.3, 0.4 and 0.5 µM primer. The qPCR assay for the detection of other mycobacterial species was done at the Tm and primer concentration of 62 °C and 0.4 µM, respectively. The HRM analysis generated cluster patterns that were specific and sensitive to distinguished small sequence differences of the Mycobacterium species. This study suggests that the 16S rRNA-based real-time PCR followed by HRM analysis produced unique cluster patterns for species of Mycobacterium and could differentiate the closely related mycobacteria species.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  19. Saville M, Sultana F, Malloy MJ, Velentzis LS, Caruana M, Ip ELO, et al.
    J Clin Microbiol, 2019 02;57(2).
    PMID: 30463896 DOI: 10.1128/JCM.01239-18
    This study demonstrates that the clinical sensitivity, specificity, and reproducibility of the novel cobas human papillomavirus (HPV) test on the cobas 6800 system for high-risk HPV types fulfills the criteria for use in population-based cervical screening. The criteria were formulated by an international consortium, using the cobas 4800 HPV test as a validated reference assay. The cobas HPV test detected over 98% of histologically confirmed cervical intraepithelial neoplasia grade 2+ (CIN2+) lesions in women age 30 years or older, with a specificity of 98.9% compared with the reference cobas 4800 test. Both the intra- and interlaboratory agreement for the cobas HPV test were 98%. The clinical performance of the cobas HPV test is comparable to those of longitudinally validated HPV assays and fulfills the criteria for its use in primary cervical screening.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  20. Al-Marzooq F, Imad MA, How SH, Kuan YC
    Trop Biomed, 2011 Dec;28(3):545-56.
    PMID: 22433883 MyJurnal
    Establishing a microbial diagnosis for patients with community-acquired pneumonia (CAP) is still challenging and is often achieved in only 30-50% of cases. Polymerase chain reaction (PCR) has been shown to be more sensitive than conventional microbiological methods and it could help to increase the microbial yield for CAP patients. This study was designed to develop, optimize and evaluate multiplex real-time PCR as a method for rapid differential detection of five bacterial causes of CAP namely Streptococcus pneumoniae, Burkholderia pseudomallei and atypical bacterial pathogens, Mycoplasma pneumoniae, Chlamydophila pneumoniae and Legionella pneumophila. Duplex and triplex real-time PCR assays were developed using five sets of primers and probes that were designed based on an appropriate specific gene for each of the above CAP pathogens. The performance of primers for each organism was tested using SYBR Green melt curve analysis following monoplex realtime PCR amplification. Monoplex real-time PCR assays were also used to optimize each primers-probe set before combining them in multiplex assays. Two multiplex real-time PCR assays were then optimized; duplex assay for the differential detection of S. pneumoniae and B. pseudomallei, and triplex assay for the atypical bacterial pathogens. Both duplex and triplex real-time PCR assays were tested for specificity by using DNA extracted from 26 related microorganisms and sensitivity by running serial dilutions of positive control DNAs. The developed multiplex real-time PCR assays shall be used later for directly identifying CAP causative agents in clinical samples.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links