Displaying publications 1 - 20 of 279 in total

Abstract:
Sort:
  1. Ahmed N, Shihabudin M.T, Ab Rahman S
    MyJurnal
    Introduction: Hamstring tendon (HT) and bone patellar tendon bone (BPTB) are the commonly used
    autograft in an anterior cruciate ligament reconstruction surgery. The BPTB is said to have more incidence of
    anterior knee pain compared to HT. The study aimed to compare the severity of knee pain during Islamic
    prayer kneeling. Methods: A cross sectional cohort analysis of patients undergoing ACL reconstruction surgery
    using BPTB with HT autografts was conducted to determine differences in postoperative pain while kneeling
    and ability to pray in normal position. Kneeling during prayer and the ability to sit while performing prayer
    were assessed at 3rd, 4th, 5th and 6th month. Results: There were no significant differences in mean pain score
    while kneeling at 3rd, 4th, 5th and 6th month. The mean difference of patient’s ability to perform normal
    prayers for BPTB (3.56+1.16) and HT (3.30+1.05) was found insignificant. The average number of patients in
    both groups was able to pray between 3 to 4 months post operatively as full range of motion of knee is
    allowed within this period. Total 49 patients (BPTB 23, HT 26) out of 60 were able to pray normally within 4
    months post-operation. Mostly delayed due to anterior knee pain. Conclusion: There is no different in term of
    knee pain during kneeling while performing Islamic prayer between those who had their ACL reconstructed
    either using BPTB or HT autograft.
    Matched MeSH terms: Range of Motion, Articular
  2. Mat Eil Ismail MS, Sharifudin MA, Shokri AA, Ab Rahman S
    Singapore Med J, 2016 Mar;57(3):138-43.
    PMID: 26996450 DOI: 10.11622/smedj.2016055
    INTRODUCTION: Physiotherapy is an important part of rehabilitation following arthroplasty, but the impact of preoperative physiotherapy on functional outcomes is still being studied. This randomised controlled trial evaluated the effect of preoperative physiotherapy on the short-term functional outcomes of primary total knee arthroplasty (TKA).
    METHODS: 50 patients with primary knee osteoarthritis who underwent unilateral primary TKA were randomised into two groups: the physiotherapy group (n = 24), whose patients performed physical exercises for six weeks immediately prior to surgery, and the nonphysiotherapy group (n = 26). All patients went through a similar physiotherapy regime in the postoperative rehabilitation period. Functional outcome assessment using the algofunctional Knee Injury and Osteoarthritis Outcome Score (KOOS) scale and range of motion (ROM) evaluation was performed preoperatively, and postoperatively at six weeks and three months.
    RESULTS: Both groups showed a significant difference in all algofunctional KOOS subscales (p < 0.001). The mean score difference at six weeks and three months was not significant in the sports and recreational activities subscale for both groups (p > 0.05). Significant differences were observed in the time-versus-treatment analysis between groups for the symptoms (p = 0.003) and activities of daily living (p = 0.025) subscales. No significant difference in ROM was found when comparing preoperative measurements and those at three months following surgery, as well as in time-versus-treatment analysis (p = 0.928).
    CONCLUSION: Six-week preoperative physiotherapy showed no significant impact on short-term functional outcomes (KOOS subscales) and ROM of the knee following primary TKA.
    KEYWORDS: algofunctional Knee Injury and Osteoarthritis Outcome Score; functional outcome; prehabilitation; preoperative physiotherapy; total knee arthroplasty
    Matched MeSH terms: Range of Motion, Articular/physiology*
  3. Ghaleb FA, Kamat MB, Salleh M, Rohani MF, Abd Razak S
    PLoS One, 2018;13(11):e0207176.
    PMID: 30457996 DOI: 10.1371/journal.pone.0207176
    The presence of motion artefacts in ECG signals can cause misleading interpretation of cardiovascular status. Recently, reducing the motion artefact from ECG signal has gained the interest of many researchers. Due to the overlapping nature of the motion artefact with the ECG signal, it is difficult to reduce motion artefact without distorting the original ECG signal. However, the application of an adaptive noise canceler has shown that it is effective in reducing motion artefacts if the appropriate noise reference that is correlated with the noise in the ECG signal is available. Unfortunately, the noise reference is not always correlated with motion artefact. Consequently, filtering with such a noise reference may lead to contaminating the ECG signal. In this paper, a two-stage filtering motion artefact reduction algorithm is proposed. In the algorithm, two methods are proposed, each of which works in one stage. The weighted adaptive noise filtering method (WAF) is proposed for the first stage. The acceleration derivative is used as motion artefact reference and the Pearson correlation coefficient between acceleration and ECG signal is used as a weighting factor. In the second stage, a recursive Hampel filter-based estimation method (RHFBE) is proposed for estimating the ECG signal segments, based on the spatial correlation of the ECG segment component that is obtained from successive ECG signals. Real-World dataset is used to evaluate the effectiveness of the proposed methods compared to the conventional adaptive filter. The results show a promising enhancement in terms of reducing motion artefacts from the ECG signals recorded by a cost-effective single lead ECG sensor during several activities of different subjects.
    Matched MeSH terms: Motion
  4. Saliem AM, Nimir AR, Abdul Kadir FA
    BMJ Case Rep, 2012;2012.
    PMID: 23087269 DOI: 10.1136/bcr-2012-006668
    Absence of the distal crease of the fingers is usually associated with a flexion deformity. A single crease of one or more fingers is found in many syndromes. We present this report as a rare case of absence of interphalangeal crease of the right ring finger with restriction of flexion but without any other anomaly.
    Matched MeSH terms: Range of Motion, Articular*
  5. Abdul Rahim R, Pang JF, Chan KS, Leong LC, Sulaiman S, Abdul Manaf MS
    ISA Trans, 2007 Apr;46(2):131-45.
    PMID: 17367791
    The data distribution system of this project is divided into two types, which are a Two-PC Image Reconstruction System and a Two-PC Velocity Measurement System. Each data distribution system is investigated to see whether the results' refreshing rate of the corresponding measurement can be greater than the rate obtained by using a single computer in the same measurement system for each application. Each system has its own flow control protocol for controlling how data is distributed within the system in order to speed up the data processing time. This can be done if two PCs work in parallel. The challenge of this project is to define the data flow process and critical timing during data packaging, transferring and extracting in between PCs. If a single computer is used as a data processing unit, a longer time is needed to produce a measurement result. This insufficient real-time result will cause problems in a feedback control process when applying the system in industrial plants. To increase the refreshing rate of the measurement result, an investigation on a data distribution system is performed to replace the existing data processing unit.
    Matched MeSH terms: Motion
  6. Rahimah Mahat, Noraihan Afiqah Rawi, Sharidan Shafie, Abdul Rahman Mohd Kasim
    Sains Malaysiana, 2018;47:1617-1623.
    The purpose of this study was to examine the effect of viscous dissipation on mixed convection flow of viscoelastic
    nanofluid past a horizontal circular cylinder. Carboxymethyl cellulose solution (CMC) is chosen as the base fluid and
    copper as a nanoparticle with the Prandtl number Pr = 6.2. The transformed boundary layer equations for momentum
    and temperature subject to the appropriate boundary conditions are solved numerically by using Keller-box method. The
    influenced of the dimensionless parameters such as Eckert number, mixed convection parameter, nanoparticles volume
    fraction and viscoelastic parameter on the flow and heat transfer characteristics is analyzed in detail and presented
    graphically. The results come out with the velocity profiles are increased while the temperature profiles are decreased
    by increasing the values of nanoparticles volume fraction and viscoelastic parameter, respectively. The graph shows
    that, increasing Eckert number the skin friction is also increases. The values of skin friction are increased by increasing
    mixed convection parameter, but the values of Nusselt number produce an opposite behavior. The present study has many
    applications especially in heat exchangers technology and oceanography. Therefore, in future, it is hoping to study the
    viscoelastic nanofluid flow past a different geometric such as sphere and cylindrical cone.
    Matched MeSH terms: Motion
  7. Wui NB, Ahmad Anuar MA, Abdul Wahid AM
    Malays J Med Sci, 2020 Jul;27(4):64-71.
    PMID: 32863746 MyJurnal DOI: 10.21315/mjms2020.27.4.6
    Background: The management of fractures around the knee in the elderly population can be challenging due to the complexity of the patients and the fracture characteristics. In this study, we aimed to investigate the short-term outcome of elderly patients who had fractures around the knee and who were treated with primary total knee arthroplasty. The study included patients who were at least 70 years old with poor bone quality and who presented with a fracture around the knee that would be difficult to treat with open reduction and internal fixation (ORIF) as well as patients who were at least 55 years old presenting with severe concomitant knee osteoarthritis.

    Methods: This is a cross-sectional study in which all the elderly patients who underwent early primary total knee replacement due to trauma around the knee at the Segamat Hospital between January 2015 and June 2019 were identified. Data were collected from clinical and operative notes. The clinical outcomes of these patients were evaluated by the range of motion of the knee and the Knee Society Score (KSS).

    Results: Ten patients were identified to have undergone this procedure. Six patients sustained supracondylar femur fractures, two patients had tibial plateau fractures and two patients had concurrent supracondylar femur and tibial plateau fractures. The mean follow-up duration was 22.3 ± 13.9 months, the mean knee score was 87.7 ± 10.0 and the mean functional knee score was 56 ± 41.9.

    Conclusion: In this cohort, good short-term outcomes close to pre-fracture condition was noted in patients who did not suffer from any complications during the post-operative period. Two patients who had surgical site infection had lower functional knee scores. Another two patients with lower knee scores experienced surgical site infection of the distal tibia and contralateral fixed flexion deformity of the knee. Early primary total knee replacement remains a viable option in treating fractures around the knee in the elderly. Infection, which in this study affected 20% of the patients, is the main deterring factor in performing this procedure.

    Matched MeSH terms: Range of Motion, Articular
  8. Javed E, Faye I, Malik AS, Abdullah JM
    J Neurosci Methods, 2017 11 01;291:150-165.
    PMID: 28842191 DOI: 10.1016/j.jneumeth.2017.08.020
    BACKGROUND: Simultaneous electroencephalography (EEG) and functional magnetic resonance image (fMRI) acquisitions provide better insight into brain dynamics. Some artefacts due to simultaneous acquisition pose a threat to the quality of the data. One such problematic artefact is the ballistocardiogram (BCG) artefact.

    METHODS: We developed a hybrid algorithm that combines features of empirical mode decomposition (EMD) with principal component analysis (PCA) to reduce the BCG artefact. The algorithm does not require extra electrocardiogram (ECG) or electrooculogram (EOG) recordings to extract the BCG artefact.

    RESULTS: The method was tested with both simulated and real EEG data of 11 participants. From the simulated data, the similarity index between the extracted BCG and the simulated BCG showed the effectiveness of the proposed method in BCG removal. On the other hand, real data were recorded with two conditions, i.e. resting state (eyes closed dataset) and task influenced (event-related potentials (ERPs) dataset). Using qualitative (visual inspection) and quantitative (similarity index, improved normalized power spectrum (INPS) ratio, power spectrum, sample entropy (SE)) evaluation parameters, the assessment results showed that the proposed method can efficiently reduce the BCG artefact while preserving the neuronal signals.

    COMPARISON WITH EXISTING METHODS: Compared with conventional methods, namely, average artefact subtraction (AAS), optimal basis set (OBS) and combined independent component analysis and principal component analysis (ICA-PCA), the statistical analyses of the results showed that the proposed method has better performance, and the differences were significant for all quantitative parameters except for the power and sample entropy.

    CONCLUSIONS: The proposed method does not require any reference signal, prior information or assumption to extract the BCG artefact. It will be very useful in circumstances where the reference signal is not available.

    Matched MeSH terms: Motion Perception/physiology
  9. Sukari AAA, Singh S, Bohari MH, Idris Z, Ghani ARI, Abdullah JM
    Malays J Med Sci, 2021 Apr;28(2):100-105.
    PMID: 33958964 DOI: 10.21315/mjms2021.28.2.9
    Background: This paper outlines a summary of examination technique to identify the range of movement of the cervical spine. Due to common difficulties in obtaining tools for cervical examination within the district, a standardised compilation of easy-to-replicate examination techniques are provided using different tools.

    Methods: Bedside instruments that can be used includes a measuring tape, compass, goniometer, inclinometer and cervical range of motion (CROM) instrument.

    Discussion: Cervical flexion-extension, lateral flexion and rotation will be assessed with bedside instruments. This would aid in increasing accuracy and precision of objective measurement while conducting clinical examination to determine the cervical range of motion.

    Matched MeSH terms: Range of Motion, Articular
  10. Jawarneh S, Abdullah S
    PLoS One, 2015;10(7):e0130224.
    PMID: 26132158 DOI: 10.1371/journal.pone.0130224
    This paper presents a bee colony optimisation (BCO) algorithm to tackle the vehicle routing problem with time window (VRPTW). The VRPTW involves recovering an ideal set of routes for a fleet of vehicles serving a defined number of customers. The BCO algorithm is a population-based algorithm that mimics the social communication patterns of honeybees in solving problems. The performance of the BCO algorithm is dependent on its parameters, so the online (self-adaptive) parameter tuning strategy is used to improve its effectiveness and robustness. Compared with the basic BCO, the adaptive BCO performs better. Diversification is crucial to the performance of the population-based algorithm, but the initial population in the BCO algorithm is generated using a greedy heuristic, which has insufficient diversification. Therefore the ways in which the sequential insertion heuristic (SIH) for the initial population drives the population toward improved solutions are examined. Experimental comparisons indicate that the proposed adaptive BCO-SIH algorithm works well across all instances and is able to obtain 11 best results in comparison with the best-known results in the literature when tested on Solomon's 56 VRPTW 100 customer instances. Also, a statistical test shows that there is a significant difference between the results.
    Matched MeSH terms: Motion
  11. Saidin S, Abdul Kadir MR, Sulaiman E, Abu Kasim NH
    J Dent, 2012 Jun;40(6):467-74.
    PMID: 22366313 DOI: 10.1016/j.jdent.2012.02.009
    The aim of this study was to analyse micromotion and stress distribution at the connections of implants and four types of abutments: internal hexagonal, internal octagonal, internal conical and trilobe.
    Matched MeSH terms: Motion
  12. Khan SJ, Khan SS, Usman J, Mokhtar AH, Abu Osman NA
    Prosthet Orthot Int, 2019 Apr;43(2):148-157.
    PMID: 30192706 DOI: 10.1177/0309364618796849
    BACKGROUND:: Knee osteoarthritis is a major contributor to the global burden of disease. There is a need of reducing knee joint load and to improve balance and physical function among knee osteoarthritis patients.

    OBJECTIVES:: To test the hypothesis that toe-out gait will reduce second peak knee adduction moment further and increase fall risk when combined with knee brace and laterally wedged insole in knee osteoarthritis patients.

    STUDY DESIGN:: Single visit study with repeated measures.

    METHODS:: First and second peak knee adduction moments, fall risk and comfort level. First and second peak knee adduction moments were determined from three-dimensional gait analysis, completed under six randomized conditions: (1) natural, (2) knee brace, (3) knee brace + toe-out gait, (4) laterally wedged insole, (5) laterally wedged insole + toe-out gait, and (6) knee brace + laterally wedged insole + toe-out gait. Fall risk was assessed by Biodex Balance System using three randomized stability settings: (1) static, (2) moderate dynamic setting (FR12), and (3) high dynamic setting (FR8).

    RESULTS:: The reduction in first peak knee adduction moment and second peak knee adduction moment was greatest (7.16% and 25.55%, respectively) when toe-out gait combine with knee brace and laterally wedged insole. Significant increase in fall risk was observed with knee brace + laterally wedged insole + toe-out gait (42.85%) at FR12. Similar significant balance reductions were found at FR8 condition for knee brace + toe-out gait (35.71%), laterally wedged insole + toe-out gait (28.57%), and knee brace + laterally wedged insole + toe-out gait (50%) as compared to natural. However, knee brace decreased fall risk at FR12 by 28.57%.

    CONCLUSION:: There is a synergistic effect of toe-out when combined with knee brace and laterally wedged insole concurrently in second peak knee adduction moment reduction but with a greater degree of fall risk. Simultaneous use of conservative treatments also decreases comfort level.

    CLINICAL RELEVANCE: Patients with mild and moderate knee osteoarthritis are usually prescribed conservative treatment techniques. This study will provide an insight whether or not a combination of these techniques have a synergistic effect in reducing knee joint load.

    Matched MeSH terms: Range of Motion, Articular/physiology*
  13. Mat Noor NA, Shafie S, Admon MA
    PLoS One, 2021;16(5):e0250402.
    PMID: 33956793 DOI: 10.1371/journal.pone.0250402
    The heat and mass transfer on time dependent hydrodynamic squeeze flow of Jeffrey nanofluid across two plates over permeable medium in the slip condition with heat generation/absorption, thermal radiation and chemical reaction are investigated. The impacts of Brownian motion and thermophoresis is examined in the Buongiorno's nanofluid model. Conversion of the governing partial differential equations to the ordinary differential equations is conducted via similarity transformation. The dimensionless equations are solved by imposing numerical method of Keller-box. The outputs are compared with previous reported works in the journals for the validation of the present outputs and found in proper agreement. The behavior of velocity, temperature, and nanoparticles concentration profiles by varying the pertinent parameters are examined. Findings portray that the acceleration of the velocity profile and the wall shear stress is due to the squeezing of plates. Furthermore, the velocity, temperature and concentration profile decline with boost in Hartmann number and ratio of relaxation to retardation times. It is discovered that the rate of heat transfer and temperature profile increase when viscous dissipation, thermophoresis and heat source/sink rises. In contrast, the increment of thermal radiation reduces the temperature and enhances the heat transfer rate. Besides, the mass transfer rate decelerates for increasing Brownian motion in nanofluid, while it elevates when chemical reaction and thermophoresis increases.
    Matched MeSH terms: Motion
  14. Lim JW, Lim PE, Seng CE, Adnan R
    Bioresour Technol, 2013 Feb;129:485-94.
    PMID: 23266850 DOI: 10.1016/j.biortech.2012.11.111
    Moving bed sequencing batch reactors (MBSBRs) packed with 8% (v/v) of 8-, 27- and 64-mL polyurethane (PU) foam cubes, respectively, were investigated for simultaneous 4-chlorophenol (4-CP) and nitrogen removal at increasing 4-CP concentration. When the 4-CP concentration exceeded 300 mg L(-1), the MBSBR with 27-mL foam cubes was observed to outperform the other MBSBRs in removing 4-CP and nitrogen. The reasons were: (1) there were more biomass in inner layer of the 27-mL cubes, compared to that of the 8-mL cubes, which was more shielded from the inhibitory effect of 4-CP and (2) the 27-mL cubes were more mobile than the 64-mL cubes. Although increasing 4-CP concentration to 600 mg L(-1) resulted in incomplete removal of 4-CP in the MBSBRs, results of the batch reactor with 27-mL foam cubes showed that complete 4-CP removal within the REACT period could be achieved by increasing the packing volume to 20%.
    Matched MeSH terms: Motion
  15. Nur Husna Md. Yusoff, Md. Jashim Uddin, Ahmad Izani Md. Ismail
    Sains Malaysiana, 2014;43:151-159.
    A combined similarity-numerical solution of the magnetohydrodynamic boundary layer slip flow of an electrically conducting non-Newtonian power-law nanofluid along a heated radiating moving vertical plate is explored. Our nanofluid model incorporates the influences of the thermophoresis and the Brownian motion. The basic transport equations are made dimensionless first and then suitable similarity transformations are applied to reduce them into a set of nonlinear ordinary differential equations with the associated boundary conditions. The reduced equations are then solved numerically. Graphical results for the non-dimensional flow velocity, the temperature and the nanoparticles volume fraction profiles as well as for the friction factor, the local Nusselt and the Sherwood numbers are exhibited and examined for various values of the controlling parameters to display the interesting aspects of the solutions. It was found that the friction factor increases with the increase of the magnetic field (M), whilst it is decreased with the linear momentum slip parameter (a). The linear momentum slip parameter (a) reduces the heat transfer rates and the nanoparticles volume fraction rates. Our results are compatible with the existing results for a special case.
    Matched MeSH terms: Motion
  16. Fathurrahman L, Hajar AH, Sakinah DW, Nurhazwani Z, Ahmad J
    Pak J Biol Sci, 2013 Nov 15;16(22):1517-23.
    PMID: 24511694
    One of the main limitations of productivity in photobioreactor is the inefficient conversion of the available light into biomass. Photoautotrophic cells such as microalgae only absorb a small fraction of supplied illumination due to limitation of its photosystem's (PS) absorbing rate. However, phenomenon of Flashing Light Effect (FLE) allows microalgae to utilize strong light exceptionally through intermittent exposure. Exposure of strong light at correct frequency of light and dark photoperiod would allow two pigment-protein complexes, PSI and PSII to be at the equilibrium mid-point potential to allow efficient light conversion. Narrow range of optimum frequency is crucial since overexposure to strong light would injured photosynthetic apparatus whereas longer dark period would contributed to loss of biomass due to triacylglycerol metabolism. The behaviour of microalgae towards various illumination conditions of FLE was determined at batch Photobioreactor (PBR) by varying the aeration flow rate: 16.94, 33.14 and 49.28 mL sec(-1) which yield, respectively the light exposure time of 3.99, 1.71 and 1.1 seconds per cycle. Maximum cell density in FLE-PBR was significantly higher at the exponential phase as compared to the continuously illuminated culture (p = 5.62 x 10(-5), a = 0.05) under the flow rate of 25.07 mL sec(-1). Maximum cell density yield of FLE-PBR and continuously illuminated PBR was, respectively 3.1125 x 10(7) and 2.947 x 10(7) cells mL(-1). Utilization of FLE as an innovative solution to increase the efficiency of microalgae to convert light into chemical energy would revolutionize the microalgae culture, reduce the time for cultivation and produce higher maximum biomass density.
    Matched MeSH terms: Motion
  17. Ahmad NS
    Sensors (Basel), 2020 Jun 30;20(13).
    PMID: 32630046 DOI: 10.3390/s20133673
    Motion control involving DC motors requires a closed-loop system with a suitable compensator if tracking performance with high precision is desired. In the case where structural model errors of the motors are more dominating than the effects from noise disturbances, accurate system modelling will be a considerable aid in synthesizing the compensator. The focus of this paper is on enhancing the tracking performance of a wheeled mobile robot (WMR), which is driven by two DC motors that are subject to model parametric uncertainties and uncertain deadzones. For the system at hand, the uncertain nonlinear perturbations are greatly induced by the time-varying power supply, followed by behaviour of motion and speed. In this work, the system is firstly modelled, where correlations between the model parameters and different input datasets as well as voltage supply are obtained via polynomial regressions. A robust H ∞ -fuzzy logic approach is then proposed to treat the issues due to the aforementioned perturbations. Via the proposed strategy, the H ∞ controller and the fuzzy logic (FL) compensator work in tandem to ensure the control law is robust against the model uncertainties. The proposed technique was validated via several real-time experiments, which showed that the speed and path tracking performance can be considerably enhanced when compared with the results via the H ∞ controller alone, and the H ∞ with the FL compensator, but without the presence of the robust control law.
    Matched MeSH terms: Motion
  18. Ahmad, D., Jamarei, O., Sulaiman, S., Fashina, A.B., Akande, F.B.
    MyJurnal
    The motion resistances of 660 mm pneumatic and rigid bicycle wheels of the same rim diameter were measured experimentally using the developed tractor-towed single non-lug narrow wheel motion resistance test rig for traction studies. The motion resistances measured were taken to be the towing forces determined in real time using Mecmesin Basic Force Gauge (BFG 2500). The test variables included two test surfaces [tilled and wet (mud) surfaces], the dynamic load and the towing velocity. The tyre inflation pressure of 414 kPa was chosen to make the surface synonymous with that of the rigid wheel. Motion resistance ratios of the two wheels were determined empirically and through semi-empirical approach. The motion resistances of the rigid wheel were found to be greater than those of the pneumatic wheel for both surfaces. Consequently, the motion resistance ratios of the rigid wheel were greater than those obtained
    from the pneumatic wheel. Analysis of variance showed that there were significant differences between the means of the motion resistance measured on the test surfaces, as well as between the two wheels and their interactions with the test surfaces. The motion resistance ratio exhibited a linear relationship with the towing velocity, while the relationship with the dynamic load was quadratic. However, such a relationship is either direct or inverse with the respective variables. The motion resistance ratio models for the pneumatic and rigid wheels showed that on different test conditions of the dynamic loads and the towing velocities, the relationships between the motion resistance ratio and the dynamic load, and motion resistance with dynamic load were also different.
    Matched MeSH terms: Motion
  19. Yew CC, Rahman SA, Alam MK
    BMC Pediatr, 2015;15:169.
    PMID: 26546159 DOI: 10.1186/s12887-015-0495-4
    The Temporomandibular Joint (TMJ) ankylosis in child is rare and yet the causes still remain unclear. This condition that affects the feeding and possible airway obstruction do not only worry the parents, but also possesses as a great challenge to the surgeons. Furthermore, it interferes with the facial skeletal and dento-alveolar development in the on growing child.
    Matched MeSH terms: Range of Motion, Articular
  20. Islam A, Sundaraj K, Ahmad RB, Sundaraj S, Ahamed NU, Ali MA
    Muscle Nerve, 2015 Jun;51(6):899-906.
    PMID: 25204740 DOI: 10.1002/mus.24454
    In this study, we analyzed the crosstalk in mechanomyographic (MMG) signals generated by the extensor digitorum (ED), extensor carpi ulnaris (ECU), and flexor carpi ulnaris (FCU) muscles of the forearm during wrist flexion (WF) and extension (WE) and radial (RD) and ulnar (UD) deviations.
    Matched MeSH terms: Range of Motion, Articular/physiology*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links