Displaying publications 1 - 20 of 280 in total

Abstract:
Sort:
  1. Saw KY, Anz A, Merican S, Tay YG, Ragavanaidu K, Jee CS, et al.
    Arthroscopy, 2011 Apr;27(4):493-506.
    PMID: 21334844 DOI: 10.1016/j.arthro.2010.11.054
    PURPOSE: The purpose of this study was to evaluate the quality of articular cartilage regeneration after arthroscopic subchondral drilling followed by postoperative intraarticular injections of autologous peripheral blood progenitor cells (PBPCs) in combination with hyaluronic acid (HA).
    METHODS: Five patients underwent second-look arthroscopy with chondral core biopsy. These 5 patients are part of a larger pilot study in which 180 patients with International Cartilage Repair Society grade III and IV lesions of the knee joint underwent arthroscopic subchondral drilling followed by postoperative intra-articular injections. Continuous passive motion was used on the operated knee 2 hours per day for 4 weeks. Partial weight bearing was observed for the first 6 to 8 weeks. Autologous PBPCs were harvested 1 week after surgery. One week after surgery, 8 mL of the harvested PBPCs in combination with 2 mL of HA was injected intra-articularly into the operated knee. The remaining PBPCs were divided into vials and cryopreserved. A total of 5 weekly intra-articular injections were given.
    RESULTS: Second-look arthroscopy confirmed articular cartilage regeneration, and histologic sections showed features of hyaline cartilage. Apart from the minimal discomfort of PBPC harvesting and localized pain associated with the intra-articular injections, there were no other notable adverse reactions.
    CONCLUSIONS: Articular hyaline cartilage regeneration is possible with arthroscopic subchondral drilling followed by postoperative intraarticular injections of autologous PBPCs in combination with HA.
    LEVEL OF EVIDENCE: Level IV, therapeutic case series.
    Matched MeSH terms: Motion Therapy, Continuous Passive
  2. A Hamid MS, Mohamed Ali MR, Yusof A, George J
    PMID: 22866670 DOI: 10.1186/1471-2474-13-138
    Muscle injuries are one of the commonest injuries affecting athletes. It often leads to significant pain and disability causing loss of training and competition time. With current treatment, the duration to return-to-play ranges form six weeks to never, depending on injury severity. Recent researches have suggested that autologous platelet-rich plasma (PRP) injection into the injured site may hasten soft tissues healing. To-date, there has been no randomised clinical trials to evaluate the effects of PRP on muscle healing. The aim of this study is to examine the effects of autologous PRP on duration to return-to-play after muscle injury.
    Matched MeSH terms: Range of Motion, Articular
  3. Miswan MF, Singh VA, Yasin NF
    Ulus Travma Acil Cerrahi Derg, 2011 Nov;17(6):504-8.
    PMID: 22290002 DOI: 10.5505/tjtes.2011.04809
    We reviewed cases with Lisfranc injuries who presented to our center in order to study the adequacy of the treatment method and their final functional outcome.
    Matched MeSH terms: Range of Motion, Articular
  4. Lau SF, Hazewinkel HA, Voorhout G
    Vet Comp Orthop Traumatol, 2015;28(3):186-92.
    PMID: 25804656 DOI: 10.3415/VCOT-14-09-0144
    To compare the development, monitored by radiography and computed tomography, of the antebrachia and elbow joints in seven Labrador Retrievers with healthy elbow joints and in seven Labrador Retrievers that developed medial coronoid disease (MCD), in order to determine whether disturbances in the development of the antebrachia and elbow joints, between the age of six and 17 weeks may lead to medial coronoid disease.
    Matched MeSH terms: Range of Motion, Articular
  5. Alizadeh M, Kadir MR, Fadhli MM, Fallahiarezoodar A, Azmi B, Murali MR, et al.
    J Orthop Res, 2013 Sep;31(9):1447-54.
    PMID: 23640802 DOI: 10.1002/jor.22376
    Posterior instrumentation is a common fixation method used to treat thoracolumbar burst fractures. However, the role of different cross-link configurations in improving fixation stability in these fractures has not been established. A 3D finite element model of T11-L3 was used to investigate the biomechanical behavior of short (2 level) and long (4 level) segmental spine pedicle screw fixation with various cross-links to treat a hypothetical L1 vertebra burst fracture. Three types of cross-link configurations with an applied moment of 7.5 Nm and 200 N axial force were evaluated. The long construct was stiffer than the short construct irrespective of whether the cross-links were used (p < 0.05). The short constructs showed no significant differences between the cross-link configurations. The XL cross-link provided the highest stiffness and was 14.9% stiffer than the one without a cross-link. The long construct resulted in reduced stress to the adjacent vertebral bodies and screw necks, with 66.7% reduction in bending stress on L2 when the XL cross-link was used. Thus, the stability for L1 burst fracture fixation was best achieved by using long segmental posterior instrumentation constructs and an XL cross-link configuration. Cross-links did not improved stability when a short structure was used.
    Matched MeSH terms: Range of Motion, Articular
  6. Collin P, Hervé A, Walch G, Boileau P, Muniandy M, Chelli M
    J Shoulder Elbow Surg, 2019 Oct;28(10):2023-2030.
    PMID: 31405717 DOI: 10.1016/j.jse.2019.03.002
    BACKGROUND: Results of anatomic shoulder arthroplasty for glenohumeral osteoarthritis with severe glenoid retroversion are unpredictable with a high rate of glenoid loosening. Reverse shoulder arthroplasty (RSA) has been suggested as an alternative, with good early results. We sought to confirm this at longer follow-up (minimum 5 years). The study hypothesis was that early results would endure over time.

    METHODS: We retrospectively reviewed all RSAs performed in 7 centers from 1998 to 2010. The inclusion criteria were primary glenohumeral osteoarthritis with B1, B2, B3, or C glenoid. Forty-nine shoulders in 45 patients fulfilled the criteria. Bone grafting was performed in 16 cases. Clinical outcomes were evaluated with the Constant score (CS) and shoulder range of motion.

    RESULTS: The mean total CS increased from 30 preoperatively to 68 points (P < .001) with significant improvements in all the subsections of the CS and range of motion. Scapular notching was observed in 20 shoulders (43%), grade 1 in 5 (11%), grade 2 in 7 (15%), grade 3 in 5 (11%), and grade 4 in 3 (6%). The glenoid bone graft healed in all the shoulders. Partial inferior lysis of the bone graft was present in 8 cases (50%). Scapular notching and glenoid bone graft resorption had no influence on the CS (P = .147 and P = .798).

    CONCLUSION: RSA for the treatment of primary glenohumeral osteoarthritis in patients with posterior glenoid deficiency and humeral subluxation without rotator cuff insufficiency resulted in excellent clinical outcomes at a minimum of 5 years of follow-up.

    Matched MeSH terms: Range of Motion, Articular
  7. Murukesu RR, Singh DKA, Shahar S
    BMC Public Health, 2019 Jun 13;19(Suppl 4):529.
    PMID: 31196015 DOI: 10.1186/s12889-019-6870-6
    BACKGROUND: Urinary incontinence (UI) is known to be more prevalent among women and is associated with decline in quality of life. The aim of our study was to investigate the prevalence, risk factors of urinary incontinence and its impact on quality of life among community dwelling older women living in urban and rural populations.

    METHODS: This study was conducted based on secondary data analysed from the third phase of the longitudinal study "Neuroprotective Model for Health Longevity among Malaysian Elderly" (LRGS TUA). Stratification of urban and rural study areas were in accordance to that determined by the Department of Statistics. A total of 814 community dwelling older women (53% urban, 47% rural), aged 60 years and above, across four states within Peninsular Malaysia were included in this analysis. Interview-based questionnaires were used to obtain respondents' sociodemographic details and clinical characteristics. The Timed Up and Go test and Handgrip Strength tests were used to assess physical function. Urinary incontinence was self-reported, and quality of life of those with incontinence was assessed using the King's Health Questionnaire (KHQ).

    RESULTS: Prevalence of urinary incontinence was 16% and 23% among older women living in urban and rural areas, respectively. Ethnicity was significantly associated with incontinence among older women in both urban and rural population (p 

    Matched MeSH terms: Time and Motion Studies
  8. Yoon KH, Kim JS, Park JY, Park SY, Kiat RYD, Kim SG
    Knee Surg Sports Traumatol Arthrosc, 2021 Jun;29(6):1936-1943.
    PMID: 32914218 DOI: 10.1007/s00167-020-06266-0
    PURPOSE: To compare clinical and radiological outcomes and failure rates between anatomical and high femoral tunnels in remnant-preserving single-bundle posterior cruciate ligament (PCL) reconstruction.

    METHODS: 63 patients who underwent remnant-preserving single-bundle PCL reconstruction between 2011 and 2018 with a minimum 2-year follow-up were retrospectively reviewed. Patients were divided into two groups according to the femoral tunnel position: group A (33 patients with anatomical femoral tunnel) and group H (30 patients with high femoral tunnels). The femoral tunnel was positioned at the center (group A) or upper margin (group H) of the remnant anterolateral bundle. The position of the femoral tunnel was evaluated using the grid method on three-dimensional computed tomography. Clinical and radiological outcomes and failure rates were compared between the groups at the 2-year follow-up.

    RESULTS: The position of the femoral tunnel was significantly high in group H than in group A (87.4% ± 4.2% versus 76.1% ± 3.7%, p motion, and posterior drawer test. Radiological outcomes also showed no intergroup differences in the side-to-side differences of posterior tibial translation and osteoarthritis progression. Side-to-side difference on the Telos stress radiograph was 5.2 ± 2.9 mm in group A and 5.2 ± 2.7 mm in group H (n.s.). There were four failures in group A (12.1%) and one in group H (3.3%). The differences between the groups were not statistically significant.

    CONCLUSION: The clinical and radiological outcomes and failure rates of the high femoral tunnels were comparable with those of the anatomical femoral tunnels at the 2-year follow-up after remnant-preserving single-bundle PCL reconstruction. The findings of this study suggest that high femoral tunnels can be considered an alternative in remnant-preserving single-bundle PCL reconstruction.

    LEVEL OF EVIDENCE: III.

    Matched MeSH terms: Range of Motion, Articular
  9. Siow WM, Chin PL, Chia SL, Lo NN, Yeo SJ
    Clin Orthop Relat Res, 2013 May;471(5):1451-7.
    PMID: 23299954 DOI: 10.1007/s11999-012-2776-7
    There is marked racial disparity in TKA use rates, demographics, and outcomes between white and Afro-Caribbean Americans. Comparative studies of ethnicity in patients undergoing TKAs have been mostly in American populations with an underrepresentation of Asian groups. It is unclear whether these disparities exist in Chinese, Malays, and Indians.
    Matched MeSH terms: Range of Motion, Articular
  10. Shahar S, Vanoh D, Mat Ludin AF, Singh DKA, Hamid TA
    BMC Public Health, 2019 Jun 13;19(Suppl 4):549.
    PMID: 31196023 DOI: 10.1186/s12889-019-6866-2
    BACKGROUND: Poverty at old age is associated with poor dietary habit, nutritional status and higher rates of chronic diseases and psychosocial problems. However, there is limited information about this matter according to urban and rural settings. The aim of this study was to identify dietary, nutritional, physical and cognitive factors associated with poor socioeconomic status (SES) among older adults according to urban and rural settings in Malaysia.

    METHODS: An analysis was conducted among 2237 older adults who participated in a longitudinal study on aging (LRGS TUA). This study involved four states in Malaysia, with 49.4% from urban areas. Respondents were divided into three categories of SES based on percentile, stratified according to urban and rural settings. SES was measured using household income.

    RESULTS: The prevalence of low SES was higher among older adults in the rural area (50.6%) as compared to the urban area (49.4%). Factors associated with low SES among older adults in an urban setting were low dietary fibre intake (Adj OR:0.91),longer time for the Timed up and Go Test (Adj OR:1.09), greater disability (Adj OR:1.02), less frequent practice of caloric restriction (Adj OR:1.65), lower cognitive processing speed score (Adj OR:0.94) and lower protein intake (Adj OR:0.94). Whilst, among respondents from rural area, the factors associated with low SES were lack of dietary fibre intake (Adj OR:0.79), lower calf circumference (Adj OR: 0.91), lesser fresh fruits intake (Adj OR:0.91), greater disability (Adj OR:1.02) and having lower score in instrumental activities of daily living (Adj OR: 0.92).

    CONCLUSION: Lower SES ismore prevalent in rural areas. Poor dietary intake, lower fitness and disability were common factors associated with low in SES, regardless of settings. Factors associated with low SES identifiedin both the urban and rural areas in our study may be useful inplanning strategies to combat low SES and its related problems among older adults.

    Matched MeSH terms: Time and Motion Studies
  11. Fallahiarezoodar A, Abdul Kadir MR, Alizadeh M, Naveen SV, Kamarul T
    Knee Surg Sports Traumatol Arthrosc, 2014 Dec;22(12):3019-27.
    PMID: 25149643 DOI: 10.1007/s00167-014-3227-7
    PURPOSE: Reproducing the femoral rollback through specially designed mechanism in knee implants is required to achieve full knee function in total knee arthroplasty. Most contemporary implants use cam/post mechanism to replace the function of Posterior Cruciate Ligament. This study was aimed to determine the most appropriate cam and post designs to produce normal femoral rollback of the knee.

    METHODS: Three different cams (triangle, ellipse, and circle) and three different posts (straight, convex, concave) geometries were considered in this study and were analysed using kinematic analyses. Femoral rollback did not occur until reaching 50° of knee flexion. Beyond this angle, two of the nine combinations demonstrate poor knee flexion and were eliminated from the study.

    RESULTS: The combination of circle cam with concave post, straight post and convex post showed 15.6, 15.9 and 16.1 mm posterior translation of the femur, respectively. The use of ellipse cam with convex post and straight post demonstrated a 15.3 and 14.9 mm femoral rollback, whilst the combination of triangle cam with convex post and straight post showed 16.1 and 15.8 mm femoral rollback, respectively.

    CONCLUSION: The present study demonstrates that the use of circle cam and convex post created the best femoral rollback effect which in turn produces the highest amount of knee flexion. The findings of the study suggest that if the design is applied for knee implants, superior knee flexion may be possible for future patients.

    LEVEL OF EVIDENCE: IV.

    Matched MeSH terms: Range of Motion, Articular
  12. Saidin S, Abdul Kadir MR, Sulaiman E, Abu Kasim NH
    J Dent, 2012 Jun;40(6):467-74.
    PMID: 22366313 DOI: 10.1016/j.jdent.2012.02.009
    The aim of this study was to analyse micromotion and stress distribution at the connections of implants and four types of abutments: internal hexagonal, internal octagonal, internal conical and trilobe.
    Matched MeSH terms: Motion
  13. Sulaiman AR, Simbak N, Wan Ismail WF, Wan Z, Halim AS
    J Orthop Surg (Hong Kong), 2011 Aug;19(2):250-3.
    PMID: 21857057
    We report 2 patients with congenital pseudoarthrosis of the tibia who underwent intramedullary Rush rod transfixation through the ankle joint following refracture and nonunion of vascularised fibular grafting 6 and 8 months earlier. After 9 and 5 years, both Rush rods were broken at the level of the ankle joints, while the reconstructed area was solidly united. The growth of the distal tibia increased the distance of the tips of the broken rod and hence the ankle joint motion. The broken tips may damage the articular cartilage and result in valgus deformity of the ankle and limb length discrepancy.
    Matched MeSH terms: Range of Motion, Articular
  14. Yong CK, Choon DS, Soon HC
    J Orthop Surg (Hong Kong), 2008 Aug;16(2):197-200.
    PMID: 18725672
    To present midterm results of Duracon total knee arthroplasty (TKA) performed between 1991 and 2001.
    Matched MeSH terms: Range of Motion, Articular
  15. Lim JW, Lim PE, Seng CE, Adnan R
    Bioresour Technol, 2013 Feb;129:485-94.
    PMID: 23266850 DOI: 10.1016/j.biortech.2012.11.111
    Moving bed sequencing batch reactors (MBSBRs) packed with 8% (v/v) of 8-, 27- and 64-mL polyurethane (PU) foam cubes, respectively, were investigated for simultaneous 4-chlorophenol (4-CP) and nitrogen removal at increasing 4-CP concentration. When the 4-CP concentration exceeded 300 mg L(-1), the MBSBR with 27-mL foam cubes was observed to outperform the other MBSBRs in removing 4-CP and nitrogen. The reasons were: (1) there were more biomass in inner layer of the 27-mL cubes, compared to that of the 8-mL cubes, which was more shielded from the inhibitory effect of 4-CP and (2) the 27-mL cubes were more mobile than the 64-mL cubes. Although increasing 4-CP concentration to 600 mg L(-1) resulted in incomplete removal of 4-CP in the MBSBRs, results of the batch reactor with 27-mL foam cubes showed that complete 4-CP removal within the REACT period could be achieved by increasing the packing volume to 20%.
    Matched MeSH terms: Motion
  16. Rahman RN, Geok LP, Basri M, Salleh AB
    Bioresour Technol, 2005 Mar;96(4):429-36.
    PMID: 15491823
    The physical factors affecting the production of an organic solvent-tolerant protease from Pseudomonas aeruginosa strain K was investigated. Growth and protease production were detected from 37 to 45 degrees C with 37 degrees C being the optimum temperature for P. aeruginosa. Maximum enzyme activity was achieved at static conditions with 4.0% (v/v) inoculum. Shifting the culture from stationary to shaking condition decreased the protease production (6.0-10.0% v/v). Extracellular organic solvent-tolerant protease was detected over a broad pH range from 6.0 to 9.0. However, the highest yield of protease was observed at pH 7.0. Neutral media increased the protease production compared to acidic or alkaline media.
    Matched MeSH terms: Motion
  17. Rasit AH, Sharaf I, Pan KL
    Med J Malaysia, 2004 Dec;59 Suppl F:52-3.
    PMID: 15941163
    Sleeve fracture of the inferior pole of the patella is a rare and distinctive fracture in children with few published reports. These fractures are frequently misdiagnosed and neglected. We highlight a case of a neglected and misdiagnosed sleeve fracture of the patella in an eleven-year-old boy. This was initially diagnosed as an avulsion fracture of the tibial tubercle. A good outcome was achieved after open reduction and internal fixation.
    Matched MeSH terms: Range of Motion, Articular
  18. Yew CC, Rahman SA, Alam MK
    BMC Pediatr, 2015;15:169.
    PMID: 26546159 DOI: 10.1186/s12887-015-0495-4
    The Temporomandibular Joint (TMJ) ankylosis in child is rare and yet the causes still remain unclear. This condition that affects the feeding and possible airway obstruction do not only worry the parents, but also possesses as a great challenge to the surgeons. Furthermore, it interferes with the facial skeletal and dento-alveolar development in the on growing child.
    Matched MeSH terms: Range of Motion, Articular
  19. Foo YH, Tunku Ahmad Yahaya TS, Chung TY, Silvanathan JP
    Photobiomodul Photomed Laser Surg, 2020 Apr;38(4):215-221.
    PMID: 32301668 DOI: 10.1089/photob.2019.4757
    Objective:
    To investigate effect of photobiomodulation (PBM) on nerve regeneration after neurotization with the Oberlin Procedure (ulnar fascicle to motor branch to biceps) to restore elbow flexion in patients with brachial plexus injury.
    Materials and methods:
    This prospective randomized controlled trial was conducted with 14 patients with high brachial plexus injury who underwent neurotization with the Oberlin Procedure to restore elbow flexion. The patients were randomly allocated to two groups of equal numbers: control group and PBM group. In this study, the PBM used has a wavelength of 808 nm, 50 mW power, continuous mode emission, 4 J/cm2 dosimetry, administered daily for 10 consecutive days, with an interval of 2 days (weekends). The outcome of surgery was assessed after 1, 2, 3, and 6 months. The nonparametric Mann-Whitney U-test and chi-square test were utilized to compare the results between both groups.
    Results:
    After 3 months postoperatively, more patients in the PBM group had demonstrated signs of reinnervation and the mean muscle power was significantly higher in the PBM group. No adverse effects resulted from the administration of PBM.
    Conclusions:
    PBM is a treatment modality that can improve nerve regeneration after neurotization with the Oberlin Procedure.
    Matched MeSH terms: Range of Motion, Articular
  20. Shariat A, Lam ET, Kargarfard M, Tamrin SB, Danaee M
    Work, 2017;56(3):421-428.
    PMID: 28269804 DOI: 10.3233/WOR-172508
    BACKGROUND: Previous research support the claim that people who work in offices and sit for a long time are particularly prone to musculoskeletal disorders.

    OBJECTIVE: The main objective of this paper is to introduce an exercise training program designed to decrease muscle stiffness and pain that can be performed in the office setting.

    METHODS: Forty healthy office workers (age: 28±5.3 years old; body mass: 87.2±10.2 kg; height: 1.79±0.15 m) apart from suffering from any sub-clinical symptoms of muscle and joint stiffness, and who had at least two years of experience in office work were chosen and randomly assigned to either an experimental group (n = 20) or a control group (n = 20). The experimental group performed the exercise training program three times a week for 11 weeks. The Cornell Musculoskeletal Discomfort Questionnaire was used to measure the pain levels in the neck, shoulders, and lower back areas. The Borg CR-10 Scale was used to measure their perceived exertion when doing the exercises, and a goniometer was used to measure the changes in range of motion (ROM) of the neck, hips, knees, and shoulders.

    RESULTS: The overall results indicated that the exercise program could significantly (p 

    Matched MeSH terms: Range of Motion, Articular
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links