Displaying publications 1 - 20 of 73 in total

Abstract:
Sort:
  1. Tan MK, Siddiqi A, Yeo LY
    Sci Rep, 2017 07 27;7(1):6652.
    PMID: 28751783 DOI: 10.1038/s41598-017-07025-x
    The Miniaturised Lab-on-a-Disc (miniLOAD) platform, which utilises surface acoustic waves (SAWs) to drive the rotation of thin millimeter-scale discs on which microchannels can be fabricated and hence microfluidic operations can be performed, offers the possibility of miniaturising its larger counterpart, the Lab-on-a-CD, for true portability in point-of-care applications. A significant limitation of the original miniLOAD concept, however, is that it does not allow for flexible control over the disc rotation direction and speed without manual adjustment of the disc's position, or the use of multiple devices to alter the SAW frequency. In this work, we demonstrate the possibility of achieving such control with the use of tapered interdigitated transducers to confine a SAW beam such that the localised acoustic streaming it generates imparts a force, through hydrodynamic shear, at a specific location on the disc. Varying the torque that arises as a consequence by altering the input frequency to the transducers then allows the rotational velocity and direction of the disc to be controlled with ease. We derive a simple predictive model to illustrate the principle by which this occurs, which we find agrees well with the experimental measurements.
    Matched MeSH terms: Point-of-Care Systems
  2. Nurul Najian AB, Engku Nur Syafirah EA, Ismail N, Mohamed M, Yean CY
    Anal Chim Acta, 2016 Jan 15;903:142-8.
    PMID: 26709307 DOI: 10.1016/j.aca.2015.11.015
    In recent years extensive numbers of molecular diagnostic methods have been developed to meet the need of point-of-care devices. Efforts have been made towards producing rapid, simple and inexpensive DNA tests, especially in the diagnostics field. We report on the development of a label-based lateral flow dipstick for the rapid and simple detection of multiplex loop-mediated isothermal amplification (m-LAMP) amplicons. A label-based m-LAMP lateral flow dipstick assay was developed for the simultaneous detection of target DNA template and a LAMP internal control. This biosensor operates through a label based system, in which probe-hybridization and the additional incubation step are eliminated. We demonstrated this m-LAMP assay by detecting pathogenic Leptospira, which causes the re-emerging disease Leptospirosis. The lateral flow dipstick was developed to detect of three targets, the LAMP target amplicon, the LAMP internal control amplicon and a chromatography control. Three lines appeared on the dipstick, indicating positive results for all representative pathogenic Leptospira species, whereas two lines appeared, indicating negative results, for other bacterial species. The specificity of this biosensor assay was 100% when it was tested with 13 representative pathogenic Leptospira species, 2 intermediate Leptospira species, 1 non-pathogenic Leptospira species and 28 other bacteria species. This study found that this DNA biosensor was able to detect DNA at concentrations as low as 3.95 × 10(-1) genomic equivalent ml(-1). An integrated m-LAMP and label-based lateral flow dipstick was successfully developed, promising simple and rapid visual detection in clinical diagnostics and serving as a point-of-care device.
    Matched MeSH terms: Point-of-Care Systems
  3. Low KF, Zain ZM, Yean CY
    Biosens Bioelectron, 2017 Jan 15;87:256-263.
    PMID: 27567251 DOI: 10.1016/j.bios.2016.08.064
    A novel enzyme/nanoparticle-based DNA biosensing platform with dual colorimetric/electrochemical approach has been developed for the sequence-specific detection of the bacterium Vibrio cholerae, the causative agent of acute diarrheal disease in cholera. This assay platform exploits the use of shelf-stable and ready-to-use (shelf-ready) reagents to greatly simplify the bioanalysis procedures, allowing the assay platform to be more amenable to point-of-care applications. To assure maximum diagnosis reliability, an internal control (IC) capable of providing instant validation of results was incorporated into the assay. The microbial target, single-stranded DNA amplified with asymmetric PCR, was quantitatively detected via electrochemical stripping analysis of gold nanoparticle-loaded latex microspheres as a signal-amplified hybridization tag, while the incorporated IC was analyzed using a simplified horseradish peroxidase enzyme-based colorimetric scheme by simple visual observation of enzymatic color development. The platform showed excellent diagnostic sensitivity and specificity (100%) when challenged with 145 clinical isolate-spiked fecal specimens. The limits of detection were 0.5ng/ml of genomic DNA and 10 colony-forming units (CFU)/ml of bacterial cells with dynamic ranges of 0-100ng/ml (R(2)=0.992) and log10 (1-10(4) CFU/ml) (R(2)=0.9918), respectively. An accelerated stability test revealed that the assay reagents were stable at temperatures of 4-37°C, with an estimated ambient shelf life of 200 days. The versatility of the biosensing platform makes it easily adaptable for quantitative detection of other microbial pathogens.
    Matched MeSH terms: Point-of-Care Systems
  4. Hu J, Wang S, Wang L, Li F, Pingguan-Murphy B, Lu TJ, et al.
    Biosens Bioelectron, 2014 Apr 15;54:585-97.
    PMID: 24333570 DOI: 10.1016/j.bios.2013.10.075
    Advanced diagnostic technologies, such as polymerase chain reaction (PCR) and enzyme-linked immunosorbent assay (ELISA), have been widely used in well-equipped laboratories. However, they are not affordable or accessible in resource-limited settings due to the lack of basic infrastructure and/or trained operators. Paper-based diagnostic technologies are affordable, user-friendly, rapid, robust, and scalable for manufacturing, thus holding great potential to deliver point-of-care (POC) diagnostics to resource-limited settings. In this review, we present the working principles and reaction mechanism of paper-based diagnostics, including dipstick assays, lateral flow assays (LFAs), and microfluidic paper-based analytical devices (μPADs), as well as the selection of substrates and fabrication methods. Further, we report the advances in improving detection sensitivity, quantification readout, procedure simplification and multi-functionalization of paper-based diagnostics, and discuss the disadvantages of paper-based diagnostics. We envision that miniaturized and integrated paper-based diagnostic devices with the sample-in-answer-out capability will meet the diverse requirements for diagnosis and treatment monitoring at the POC.
    Matched MeSH terms: Point-of-Care Systems*
  5. Choi JR, Liu Z, Hu J, Tang R, Gong Y, Feng S, et al.
    Anal Chem, 2016 06 21;88(12):6254-64.
    PMID: 27012657 DOI: 10.1021/acs.analchem.6b00195
    In nucleic acid testing (NAT), gold nanoparticle (AuNP)-based lateral flow assays (LFAs) have received significant attention due to their cost-effectiveness, rapidity, and the ability to produce a simple colorimetric readout. However, the poor sensitivity of AuNP-based LFAs limits its widespread applications. Even though various efforts have been made to improve the assay sensitivity, most methods are inappropriate for integration into LFA for sample-to-answer NAT at the point-of-care (POC), usually due to the complicated fabrication processes or incompatible chemicals used. To address this, we propose a novel strategy of integrating a simple fluidic control strategy into LFA. The strategy involves incorporating a piece of paper-based shunt and a polydimethylsiloxane (PDMS) barrier to the strip to achieve optimum fluidic delays for LFA signal enhancement, resulting in 10-fold signal enhancement over unmodified LFA. The phenomena of fluidic delay were also evaluated by mathematical simulation, through which we found the movement of fluid throughout the shunt and the tortuosity effects in the presence of PDMS barrier, which significantly affect the detection sensitivity. To demonstrate the potential of integrating this strategy into a LFA with sample-in-answer-out capability, we further applied this strategy into our prototype sample-to-answer LFA to sensitively detect the Hepatitis B virus (HBV) in clinical blood samples. The proposed strategy offers great potential for highly sensitive detection of various targets for wide application in the near future.
    Matched MeSH terms: Point-of-Care Systems*
  6. Choi JR, Hu J, Gong Y, Feng S, Wan Abas WA, Pingguan-Murphy B, et al.
    Analyst, 2016 05 10;141(10):2930-9.
    PMID: 27010033 DOI: 10.1039/c5an02532j
    Lateral flow assays (LFAs) have been extensively explored in nucleic acid testing (NAT) for medical diagnostics, food safety analysis and environmental monitoring. However, the amount of target nucleic acid in a raw sample is usually too low to be directly detected by LFAs, necessitating the process of amplification. Even though cost-effective paper-based amplification techniques have been introduced, they have always been separately performed from LFAs, hence increasing the risk of reagent loss and cross-contaminations. To date, integrating paper-based nucleic acid amplification into colorimetric LFA in a simple, portable and cost-effective manner has not been introduced. Herein, we developed an integrated LFA with the aid of a specially designed handheld battery-powered system for effective amplification and detection of targets in resource-poor settings. Interestingly, using the integrated paper-based loop-mediated isothermal amplification (LAMP)-LFA, we successfully performed highly sensitive and specific target detection, achieving a detection limit of as low as 3 × 10(3) copies of target DNA, which is comparable to the conventional tube-based LAMP-LFA in an unintegrated format. The device may serve in conjunction with a simple paper-based sample preparation to create a fully integrated paper-based sample-to-answer diagnostic device for point-of-care testing (POCT) in the near future.
    Matched MeSH terms: Point-of-Care Systems
  7. Choi JR, Hu J, Tang R, Gong Y, Feng S, Ren H, et al.
    Lab Chip, 2016 Feb 7;16(3):611-21.
    PMID: 26759062 DOI: 10.1039/c5lc01388g
    With advances in point-of-care testing (POCT), lateral flow assays (LFAs) have been explored for nucleic acid detection. However, biological samples generally contain complex compositions and low amounts of target nucleic acids, and currently require laborious off-chip nucleic acid extraction and amplification processes (e.g., tube-based extraction and polymerase chain reaction (PCR)) prior to detection. To the best of our knowledge, even though the integration of DNA extraction and amplification into a paper-based biosensor has been reported, a combination of LFA with the aforementioned steps for simple colorimetric readout has not yet been demonstrated. Here, we demonstrate for the first time an integrated paper-based biosensor incorporating nucleic acid extraction, amplification and visual detection or quantification using a smartphone. A handheld battery-powered heating device was specially developed for nucleic acid amplification in POC settings, which is coupled with this simple assay for rapid target detection. The biosensor can successfully detect Escherichia coli (as a model analyte) in spiked drinking water, milk, blood, and spinach with a detection limit of as low as 10-1000 CFU mL(-1), and Streptococcus pneumonia in clinical blood samples, highlighting its potential use in medical diagnostics, food safety analysis and environmental monitoring. As compared to the lengthy conventional assay, which requires more than 5 hours for the entire sample-to-answer process, it takes about 1 hour for our integrated biosensor. The integrated biosensor holds great potential for detection of various target analytes for wide applications in the near future.
    Matched MeSH terms: Point-of-Care Systems*
  8. Hu J, Yew CT, Chen X, Feng S, Yang Q, Wang S, et al.
    Talanta, 2017 Apr 01;165:419-428.
    PMID: 28153277 DOI: 10.1016/j.talanta.2016.12.086
    The identification and quantification of chemicals play a vital role in evaluation and surveillance of environmental health and safety. However, current techniques usually depend on costly equipment, professional staff, and/or essential infrastructure, limiting their accessibility. In this work, we develop paper-based capacitive sensors (PCSs) that allow simple, rapid identification and quantification of various chemicals from microliter size samples with the aid of a handheld multimeter. PCSs are low-cost parallel-plate capacitors (~$0.01 per sensor) assembled from layers of aluminum foil and filter paper via double-sided tape. The developed PCSs can identify different kinds of fluids (e.g., organic chemicals) and quantify diverse concentrations of substances (e.g., heavy metal ions) based on differences in dielectric properties, including capacitance, frequency spectrum, and dielectric loss tangent. The PCS-based method enables chemical identification and quantification to take place much cheaply, simply, and quickly at the point-of-care (POC), holding great promise for environmental monitoring in resource-limited settings.
    Matched MeSH terms: Point-of-Care Systems
  9. Choi JR, Yong KW, Tang R, Gong Y, Wen T, Yang H, et al.
    Adv Healthc Mater, 2017 Jan;6(1).
    PMID: 27860384 DOI: 10.1002/adhm.201600920
    Paper-based devices have been broadly used for the point-of-care detection of dengue viral nucleic acids due to their simplicity, cost-effectiveness, and readily observable colorimetric readout. However, their moderate sensitivity and functionality have limited their applications. Despite the above-mentioned advantages, paper substrates are lacking in their ability to control fluid flow, in contrast to the flow control enabled by polymer substrates (e.g., agarose) with readily tunable pore size and porosity. Herein, taking the benefits from both materials, the authors propose a strategy to create a hybrid substrate by incorporating agarose into the test strip to achieve flow control for optimal biomolecule interactions. As compared to the unmodified test strip, this strategy allows sensitive detection of targets with an approximately tenfold signal improvement. Additionally, the authors showcase the potential of functionality improvement by creating multiple test zones for semi-quantification of targets, suggesting that the number of visible test zones is directly proportional to the target concentration. The authors further demonstrate the potential of their proposed strategy for clinical assessment by applying it to their prototype sample-to-result test strip to sensitively and semi-quantitatively detect dengue viral RNA from the clinical blood samples. This proposed strategy holds significant promise for detecting various targets for diverse future applications.
    Matched MeSH terms: Point-of-Care Systems*
  10. Wan Mohd Zin RM, Ahmad Kamil ZI, Tuan Soh TR, Embong M, Wan Mohamud WN
    BMC Res Notes, 2013 Dec 18;6:540.
    PMID: 24344903 DOI: 10.1186/1756-0500-6-540
    BACKGROUND: Measurement of HbA1c has been widely used for long-term monitoring and management of diabetes control. There is increasing use of point-of-care (POC) devices for measuring HbA1c where quicker results would allow immediate clinical management decisions to be made. Therefore, it is important to evaluate and compare the performance of such devices to the reference laboratory method.

    FINDINGS: A total of 274 venous blood was collected from normal healthy adults during the community screening programmes. The performance of POC devices, Afinion and Quo-test were compared to central laboratory HPLC method; Adams A1c HA 8160. Both POC devices showed good correlation to HA 8160 with r = 0.94 (p < 0.001) and r = 0.95 (p < 0.001) for Afinion and Quo-test respectively. The means difference were statistically higher between POC and HA 8160 with 0.23% (95% CI 0.19-0.26, p < 0.001) and 0.29% (95% CI 0.24-0.34, p < 0.001) for Afinion and Quo-test respectively.

    CONCLUSIONS: Both POC devices could be considered in health clinics for diabetes management but not to be used for the diagnostic purposes.

    Matched MeSH terms: Point-of-Care Systems/standards*
  11. Adi O, Fong CP, Azil A, Wahab SFA
    Ultrasound J, 2019 Feb 25;11(1):1.
    PMID: 31359296 DOI: 10.1186/s13089-019-0116-9
    BACKGROUND: We report a case study of fat embolism seen on ultrasound at right internal jugular vein during central venous cannulation in a patient diagnosed with fat embolism syndrome. This case demonstrates the importance of ultrasound for evaluation of trauma cases with suspicion of fat embolism.

    CASE PRESENTATION: A 23-year-old trauma patient with closed fracture of left femoral shaft and left humerus presented to our emergency department (ED). 11 h after admission to ED, patient became confused, hypoxic and hypotensive. He was then intubated for respiratory failure and mechanically ventilated. Transesophageal ultrasound revealed hyperdynamic heart, dilated right ventricle with no regional wall abnormalities and no major aorta injuries. Whole-body computed tomography was normal. During central venous cannulation of right internal jugular vein (IJV), we found free floating mobile hyperechoic spots, located at the anterior part of the vein. A diagnosis of fat embolism syndrome later was made based on the clinical presentation of long bone fractures and fat globulin in the blood. Despite aggressive fluid resuscitation, patient was a non-responder and needed vasopressor infusion for persistent shock. Blood aspirated during cannulation from the IJV revealed a fat globule. Patient underwent uneventful orthopedic procedures and was discharged well on day 5 of admission.

    CONCLUSIONS: Point-of-care ultrasound findings of fat embolism in central vein can facilitate and increase the suspicion of fat embolism syndrome.

    Matched MeSH terms: Point-of-Care Systems
  12. Balakrishnan SR, Hashim U, Gopinath SC, Poopalan P, Ramayya HR, Iqbal Omar M, et al.
    PLoS One, 2015;10(9):e0137891.
    PMID: 26368287 DOI: 10.1371/journal.pone.0137891
    Human chorionic gonadotropin (hCG), a glycoprotein hormone secreted from the placenta, is a key molecule that indicates pregnancy. Here, we have designed a cost-effective, label-free, in situ point-of-care (POC) immunosensor to estimate hCG using a cuneated 25 nm polysilicon nanogap electrode. A tiny chip with the dimensions of 20.5 × 12.5 mm was fabricated using conventional lithography and size expansion techniques. Furthermore, the sensing surface was functionalized by (3-aminopropyl)triethoxysilane and quantitatively measured the variations in hCG levels from clinically obtained human urine samples. The dielectric properties of the present sensor are shown with a capacitance above 40 nF for samples from pregnant women; it was lower with samples from non-pregnant women. Furthermore, it has been proven that our sensor has a wide linear range of detection, as a sensitivity of 835.88 μA mIU(-1) ml(-2) cm(-2) was attained, and the detection limit was 0.28 mIU/ml (27.78 pg/ml). The dissociation constant Kd of the specific antigen binding to the anti-hCG was calculated as 2.23 ± 0.66 mIU, and the maximum number of binding sites per antigen was Bmax = 22.54 ± 1.46 mIU. The sensing system shown here, with a narrow nanogap, is suitable for high-throughput POC diagnosis, and a single injection can obtain triplicate data or parallel analyses of different targets.
    Matched MeSH terms: Point-of-Care Systems*
  13. Kho SS, Chan SK, Yong MC, Cheah HM, Lee YG, Tie ST
    Respir Investig, 2020 Sep;58(5):367-375.
    PMID: 32107195 DOI: 10.1016/j.resinv.2020.01.004
    BACKGROUND: Tuberculous pleural effusions (TBEs) and parapneumonic pleural effusion (PPEs) have similar clinical presentations and fluid biochemistry. A pleural biopsy is usually required to diagnose TBE but complete fluid evacuation may not be necessary, contrasting with complicated PPE (CPPE). A point-of-care test that distinguishes between TBE and CPPE enables the appropriate procedures to be performed during the initial diagnostic thoracentesis. Lactate is a metabolic product measurable by a blood-gas analyzer. This study measured pleural fluid (Pf) lactate levels in TBE and compared them with those in PPE/CPPE. We hypothesized that Pf lactate would be significantly higher in PPE because of active metabolic activities than in TBE which is driven by delayed hypersensitivity.

    METHODS: All patients undergoing an initial diagnostic thoracentesis over 18 months with Pf lactate measured using a calibrated point-of-care blood gas analyzer were assessed.

    RESULTS: The diagnoses of the enrolled patients (n = 170) included TBE (n = 49), PPE (n = 47), malignancy (n = 63), and transudate (n = 11). Pf lactate level in TBE, median 3.70 (inter-quartile range 2.65-4.90) mmol/l, was significantly lower than in PPE and CPPE. In the subgroup of TBE and CPPE patients whose initial Pf pH and glucose could suggest either condition, Pf lactate was significantly higher in those with CPPE. Pf lactate (cutoff ≥7.25 mmol/l) had a sensitivity of 79.3%, specificity 100%, positive predictive value 100%, and negative predictive value 89.1% for discriminating CPPE from TBE (area under the curve 0.947, p Point-of-care Pf lactate measurements may have practical value in early separation of TBE or CPPE during initial thoracentesis, and warrants further investigation.

    Matched MeSH terms: Point-of-Care Systems*
  14. Osman A, Fong CP, Wahab SFA, Panebianco N, Teran F
    J Emerg Med, 2020 Sep;59(3):418-423.
    PMID: 32591302 DOI: 10.1016/j.jemermed.2020.05.003
    BACKGROUND: Although surface sonography has become an essential diagnostic tool in the evaluation of trauma patients, important limitations of this modality include the evaluation of retroperitoneal hemorrhage and mediastinal pathology, such as blunt traumatic aortic injuries (BTAI). As in other emergency applications where surface sonography can't provide the information needed, focused transesophageal echocardiography (TEE) may represent a valuable diagnostic tool in the evaluation of hemodynamically unstable trauma patients with suspected thoracic pathology such as BTAI.

    CASE SERIES: We present a series of five cases that illustrate the diagnostic value of emergency physician-performed resuscitative TEE in the diagnosis of BTAI in patients presenting with blunt thoracic trauma. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: As the use of point-of-care TEE during resuscitation continues to expand in emergency medicine, the evaluation of patients with BTAI represents a novel application where this emerging modality can allow early diagnosis of these injuries in hemodynamically unstable patients.

    Matched MeSH terms: Point-of-Care Systems
  15. Teng CL
    MyJurnal
    In the developing world, clinical knowledge management in primary care has a long way to go. Clinical decision support systems, despite its promise to revolutionise healthcare, is slow in its implementation due to the lack of financial investment in information technology. Point-of-care resources, such as comprehensive electronic textbooks delivered via the web or mobile devices, have yet to be fully utilised by the healthcare organisation or individual clinicians. Increasing amount of applicable knowledge of good quality (e.g. clinical practice guidelines and other pre-appraised resources) are now available via the internet. The policy makers and clinicians need to be more informed about the potential benefits and
    limitations of these new tools and resources and make the necessary budgetary provision and learn how best to harness them for patient care.
    Matched MeSH terms: Point-of-Care Systems
  16. Teng CL
    Malays Fam Physician, 2014;9(2):18-25.
    PMID: 25893067 MyJurnal
    This review highlights the high prevalence of antibiotic use for upper respiratory tract infections (URTIs) in a larger part of the Asia-Pacific region. Since URTIs are one of the common reasons for primary care consultations in this region, inappropriate use of antibiotic in both quantity and drug choice has greatly influenced the development of antibiotic resistance. Notwithstanding the paucity of Asia-Pacific data on the above issues, the available information suggests urgent actions needed to be taken to promote judicious antibiotic use at the point-of-care through a multi- pronged approach targeting the patients/consumers (or parents), healthcare providers and health care systems.
    Matched MeSH terms: Point-of-Care Systems
  17. Fathil MF, Md Arshad MK, Gopinath SC, Hashim U, Adzhri R, Ayub RM, et al.
    Biosens Bioelectron, 2015 Aug 15;70:209-20.
    PMID: 25841117 DOI: 10.1016/j.bios.2015.03.037
    Acute myocardial infarction or myocardial infarction (MI) is a major health problem, due to diminished flow of blood to the heart, leads to higher rates of mortality and morbidity. Data from World Health Organization (WHO) accounted 30% of global death annually and expected more than 23 million die annually by 2030. This fatal effects trigger the need of appropriate biomarkers for early diagnosis, thus countermeasure can be taken. At the moment, the most specific markers for cardiac injury are cardiac troponin I (cTnI) and cardiac troponin T (cTnT) which have been considered as 'gold standard'. Due to higher specificity, determination of the level of cardiac troponins became a predominant indicator for MI. Several ways of diagnostics have been formulated, which include enzyme-linked immunosorbent assay, chemiluminescent, fluoro-immunoassays, electrical detections, surface plasmon resonance, and colorimetric protein assay. This review represents and elucidates the strategies, methods and detection levels involved in these diagnostics on cardiac superior biomarkers. The advancement, sensitivity, and limitations of each method are also discussed. In addition, it concludes with a discussion on the point-of care (POC) assay for a fast, accurate and ability of handling small sample measurement of cardiac biomarker.
    Matched MeSH terms: Point-of-Care Systems*
  18. Citartan M, Tang TH
    Talanta, 2019 Jul 01;199:556-566.
    PMID: 30952298 DOI: 10.1016/j.talanta.2019.02.066
    Aptamers are nucleic acid-based molecular recognition elements that are specific and have high binding affinity against their respective targets. On account of their target recognition capacity, aptamers are widely utilized in a number of applications including diagnostics. This review aims to highlight the recent developments of aptasensors expedient for point-of-care (POC) diagnostics. Significant focus is given on the primary assay formats of aptamers such as fluorescence, electrochemical, surface plasmon resonance (SPR) and colorimetric assays. A potpourri of platforms such as paper-based device, lateral flow assay, portable electrodes, portable SPR and smart phones expedient for point-of-care (POC) diagnostics are discussed. Emphasis is also given on the technicalities and assay configurations associated with the sensors.
    Matched MeSH terms: Point-of-Care Systems*
  19. Ang KM, Yeo LY, Hung YM, Tan MK
    Lab Chip, 2016 09 21;16(18):3503-14.
    PMID: 27502324 DOI: 10.1039/c6lc00780e
    The deposition of a thin graphene film atop a chip scale piezoelectric substrate on which surface acoustic waves are excited is observed to enhance its performance for fluid transport and manipulation considerably, which can be exploited to achieve further efficiency gains in these devices. Such gains can then enable complete integration and miniaturization for true portability for a variety of microfluidic applications across drug delivery, biosensing and point-of-care diagnostics, among others, where field-use, point-of-collection or point-of-care functionality is desired. In addition to a first demonstration of vibration-induced molecular transport in graphene films, we show that the coupling of the surface acoustic wave gives rise to antisymmetric Lamb waves in the film which enhance molecular diffusion and hence the flow through the interstitial layers that make up the film. Above a critical input power, the strong substrate vibration displacement can also force the molecules out of the graphene film to form a thin fluid layer, which subsequently destabilizes and breaks up to form a mist of micron dimension aerosol droplets. We provide physical insight into this coupling through a simple numerical model, verified through experiments, and show several-fold improvement in the rate of fluid transport through the film, and up to 55% enhancement in the rate of fluid atomization from the film using this simple method.
    Matched MeSH terms: Point-of-Care Systems
  20. Peyman M, Tai LY, Khaw KW, Ng CM, Win MM, Subrayan V
    Int Ophthalmol, 2015 Oct;35(5):651-5.
    PMID: 25189684 DOI: 10.1007/s10792-014-9989-6
    To assess the intra-observer repeatability and inter-observer reproducibility of central corneal thickness (CCT) measurements of PachPen (Accutome, Inc., Pennsylvania, USA), a hand-held, portable ultrasonic pachymeter when used by an ophthalmic nurse compared to an ophthalmologist. Ophthalmology Clinic, University of Malaya Medical Center In this prospective study, CCT was measured in 184 eyes of 92 healthy subjects, first by a corneal surgeon experienced in ultrasound pachymetry (Observer 1) followed by an ophthalmic nurse new to the procedure (Observer 2). Nine measurements were obtained from each eye by each observer, independently. Measurements were compared between the observers. Coefficients of repeatability and reproducibility were calculated. The Bland-Altman plot was used to assess agreement between observers. Mean age of the study population was 54.3 ± 15.2 years old and consisted of 43.5% male. Mean CCT as measured by Observers 1 and 2 were 528.3 ± 32.9 and 530.7 ± 33.3 µm, respectively. Observer 1 showed higher repeatability of measurements compared to that of Observer 2 (coefficient of repeatability 3.46 vs. 5.55%). The measurements by both observers showed high correlation (0.96) and good agreement (mean difference -2.4 µm; 95% limits of agreement -21.4, 16.7 µm). Coefficient of reproducibility of measurements between observers was 5.08%. Accutome PachPen hand-held ultrasound pachymeters gives excellent intra-observer repeatability and inter-observer reproducibility by personnel of different training grades.
    Matched MeSH terms: Point-of-Care Systems*