Displaying publications 1 - 20 of 185 in total

Abstract:
Sort:
  1. Tay WM
    Dent J Malaysia Singapore, 1968 Feb;8(1):24-8.
    PMID: 5248555
    Matched MeSH terms: Stainless Steel
  2. Abdul Razak Daud, Azleen Mohd. Zain, Azali Muhamad
    A single wall single image x-ray radiographic technique was adopted to investigate thickness variation of steel specimens caused by uniform corrosion. The ability of the 100 kV-160 kV x-rays to produce a meaningful film density for steel was also investigated. The thickness contour maps of corroded steel plates were found matching with the x-ray film density contour maps of the plates. The results confirm that x-ray radiography can be used to detect the thickness reduction of steel caused by uniform corrosion.
    Bagi mengesan perubahan ketebalan keluli akibat kakisan seragam maka radiografi sinar-x teknik imej tunggal dinding tunggal telah digunakan. Kemampuan sinar-x 100 kV-160 kV menghasilkan ketumpatan filem yang sesuai untuk keluli telah juga dikaji. Peta kontur ketebalan bagi spesimen kepingan keluli yang telah mengalami kakisan seragam didapati sepadan dengan peta kontur ketumpatan filem radiografi sinar-x bagi spesimen tersebut. Kajian ini menunjukkan radiografi sinar-x boleh digunakan bagi mengesan penipisan keluli akibat kakisan seragam.
    Matched MeSH terms: Steel
  3. Razak AA, Harrison A
    J Prosthet Dent, 1997 Apr;77(4):353-8.
    PMID: 9104710
    Dimensional accuracy of a composite inlay restoration is important to ensure an accurate fit and to minimize cementation stresses.
    Matched MeSH terms: Stainless Steel
  4. Benjakul P, Cheunarrom C, Ongthiemsak C
    J Oral Sci, 2001 Mar;43(1):15-9.
    PMID: 11383631
    Stainless steel wrought wires used as clasp arms for removable partial dentures in Thailand were compared with those used in some other countries (in the as-received condition) in terms of flexibility, Vickers microhardness and composition. The results showed that there were significant differences (P< or =0.05) among the wires. A Japanese stainless steel wire (SK) was obviously different from the others. It had the lowest proportional limit and microhardness, but its flexibility was almost the same. The chemical composition of each wire was not greatly different. The wires were about 18-20 wt% chromium and 8-9 wt% nickel, except for the SK wire, which had about 12 wt% nickel.
    Matched MeSH terms: Stainless Steel/analysis; Stainless Steel/chemistry*
  5. Bidawid S, Malik N, Adegbunrin O, Sattar SA, Farber JM
    J Food Prot, 2004 Jan;67(1):103-9.
    PMID: 14717359
    While there is good epidemiological evidence for foods as vehicles for norovirus transmission, the precise means of spread and its control remain unknown. The feline calicivirus was used as a surrogate for noroviruses to study infectious virus transfer between hands and selected types of foods and environmental surfaces. Assessment of the potential of selected topicals in interrupting such virus transfer was also made. Ten microliters of inoculum of feline calicivirus deposited onto each fingerpad of adult subjects was allowed to air dry and the contaminated area on individual fingerpads was pressed (10 s at a pressure of 0.2 to 0.4 kg/cm2) onto 1-cm-diameter disks of ham, lettuce, or brushed stainless steel. The virus remaining on the donor and that transferred to the recipient surfaces was eluted and plaque assayed. Virus transfer to clean hands from experimentally contaminated disks of ham, lettuce, and stainless steel was also tested. Nearly 46 +/- 20.3, 18 +/- 5.7, and 13 +/- 3.6% of infectious virus was transferred from contaminated fingerpads to ham, lettuce, and metal disks, respectively. In contrast, approximately 6 +/- 1.8, 14 +/- 3.5, and 7 +/- 1.9% virus transfer occurred, respectively, from ham, lettuce, and metal disks to hands. One-way analysis of variance test showed that pretreatment (washing) of the fingerpads either with water or with both topical agent and water significantly (P < 0.05) reduced virus transfer to < or = 0.9%, as compared with < or = 2.3 and < or = 3.4% transfer following treatments with either 75% (vol/vol) ethanol or a commercial hand gel containing 62% ethanol, respectively. Despite wide variations in virus transfer among the targeted items used, intervention agents tested reduced virus transfer significantly (P < 0.05) when compared with that without such treatments (71 +/- 8.9%). These findings should help in a better assessment of the potential for cross-contamination of foods during handling and also assist in developing more effective approaches to foodborne spread of norovirus infections.
    Matched MeSH terms: Stainless Steel
  6. Hussain PB, Mohammad M
    Med J Malaysia, 2004 May;59 Suppl B:180-1.
    PMID: 15468877
    Failure analysis was performed to investigate the failure of the femur fixation plate which was previously fixed on the femur of a girl. Radiography, metallography, fractography and mechanical testing were conducted in this study. The results show that the failure was due to the formation of notches on the femur plate. These notches act as stress raisers from where the cracks start to propagate. Finally fracture occurred on the femur plate and subsequently, the plate failed.
    Matched MeSH terms: Stainless Steel*
  7. Santin M, Morris C, Harrison M, Mikhalovska L, Lloyd AW, Mikhalovsky S
    Med J Malaysia, 2004 May;59 Suppl B:93-4.
    PMID: 15468834
    In-stent restenosis is caused by the proliferation of the smooth muscle cells (SMCs) following a host response towards the implanted device. However, the precise biochemical and cellular mechanisms are still not completely understood. In this paper, the behaviour of SMCs has been investigated by an in vitro model where the cells were stimulated by platelet derived growth factor (PDGF) on tissue-like substrates as well as on biomaterials such as stainless steel (St) and diamond-like carbon (DLC)-coated St. The results demonstrated that SMCs have a completely different adhesion mode on St and become particularly prone to proliferation and pro-inflammatory cytokine secretion under PDGF stimulus. This would suggest that restenosis may caused by the accidental contact of the SMC with the St substrate under an inflammatory insult.
    Matched MeSH terms: Stainless Steel
  8. Meor Yusoff Meor Sulaiman
    MyJurnal
    One of the non-destructive methods used for the identification and verification of metals is by the energy-dispersive X-ray fluorescence (EDXRF) technique. EDXRF analysis provides several important advantages such as simultaneous determination of the elements present, enable to analyse a very wide concentration range, fast analysis with no tedious sample preparation. The paper shows how this technique is developed and applied in the identification and verification of different grades of stainless steels. Comparison of the results obtained from this analysis with certified reference standards show very small differences between them.
    Matched MeSH terms: Stainless Steel
  9. Che Ab Aziz, Z.A., Abdullah, M., Vello, C.D.S., Thangavelu, K.
    Ann Dent, 2006;13(1):12-17.
    MyJurnal
    Background: Majority of root canal treatment in Malaysia was provided by general dental practitioner. The purpose of this study was to evaluate the knowledge and practice (canal’s preparation, use of materials) by them. Methods: A questionnaire was structured and distributed to 120 registered general dental practitioners in selected areas in Perak, Johor and Klang Valley regarding the provision of root canal therapy in their practices. The questionnaires were hand delivered and collected after 1 to 2 weeks. Results: Reply rate was 95% (n=114). The result demonstrated that 62% respondents indicated that they performed the root canal therapy (RCT) themselves. Out of these only 26% included molars in the treatment. Three quarters of them (77%) used step-back technique and 54% used stainless steel instruments to prepare the canals. The majority of the respondents (69%) used calcium hydroxide as intracanal medicaments. Only 30% used rubber dam for isolation whereas the rest used cotton rolls. The numbers of routine radiographs taken were two for anterior teeth and three for molar. Half of the respondents indicated that they usually completed the RCT for the anterior tooth within two visits whereas three visits were needed for the molar tooth. The results were analyzed descriptively. Conclusions: This study indicates that most of the general dental practitioners’ do not comply with quality standards guidelines such as use of rubber dam as isolation. Cotton roll was the most popular isolation method. In spite of this, most of the respondents tend to update their knowledge and practices with current techniques and materials.
    Matched MeSH terms: Stainless Steel
  10. Zaili MA, Kuppuswamy R, Harun H
    Forensic Sci Int, 2007 Aug 24;171(1):27-32.
    PMID: 17088038
    It is known that restoration of erased engraved identification marks on the engine and the chassis of a car or on a firearm has low success rate. Unlike stamping, engraving on a metal surface leaves no pronounced, permanent subsurface deformation in the crystalline structure, also called dislocation that can be revealed by suitable methods. Hence, the current research work investigated whether metallographic reagents used in the restoration of stamp (compression) marks could be applied to recover engraved marks on steel surfaces and also to establish the sensitivity and effectiveness of some of these reagents for the restoration of the marks. Experiments were conducted by mechanically engraving alphanumeric characters on several steel plates using a computer controlled engraving machine called Gravograph. The markings were later erased from the above steel plates by removing the metal in stages of 0.01 mm through 0.04 mm below the bottom of the engraving. Several plates were thus prepared wherein each one had been abraded to a specific depth. Then eight metallographic reagents were tested on each one of the above erased plates using a swabbing technique. The results had shown that while most of the reagents were able to restore marks up to certain levels of erasure, the reagent 5 g copper sulphate, 60 ml water, 30 ml concentrated ammonium hydroxide and 60 ml concentrated hydrochloric acid restored marks erased to a depth of 0.04 mm below the engraving depth, thus presenting itself the most sensitive reagent. Quite significantly, the above reagent was also able to decipher successfully the original engraved marks that had been erased and engraved with a new number, or obliterated by centre punching. The results of this research work should benefit the forensic practitioners engaged in the serial number recovery on vehicles, firearms and other objects.
    Matched MeSH terms: Steel
  11. Mohamad Zaky Noh, Luay Bakir Hussain, Zainal Arifin Ahmad
    MyJurnal
    The joining of ceramic-metal could be done through a few techniques: brazing, diffusion bonding, friction welding etc. However, the mechanism of ceramic-metal joining was still not properly understood. In this study, alumina rod was bonded to mild steel rod via friction welding technique by using Al 1100 sheet as interlayer. The diameter of the rods was 10 mm. Friction pressure of 20 MPa and forging pressure of 40 MPa were used. Rotational speeds were maintained at 900 rpm and friction times of 2 to 20 seconds were applied. The joining strength was determined through four point bending test. The maximum bending strength, 240 MPa was obtained at the friction times of 20 seconds. Under optical microscope and SEM observation, the deformation of the aluminum interface was clearly obtained. Mechanical interlocking and close contact between the aluminaaluminum and aluminum-mild steel were observed at magnifications of 3000X. The strength of alumina-steel bonding is much dependent on the wettability of the alumina surface by the molten aluminum and the existing of mechanical interlocking between interlayer and sample materials.
    Matched MeSH terms: Steel
  12. Hariyanti, Purwadaria, S., Zainal Arifin Ahmad
    MyJurnal
    Electrodeposition of white copper-tin alloys (including white miralloys) has been done onto planar mild steel substrates from alkaline cyanide solutions at 65 0 C. The chemical composition of the coating is influenced by plating bath composition and current density. White miralloy can be produced from the test solution containing 10 g/l CuCN2 - , 45 g/l Na2SnO3, 25 g/l NaCN, and 12 g/l NaOH at current density about 5 mA/cm 2 . The local compositions of the coating cross section were analyzed using EDX installed in a FESEM operated at an accelerating voltage of 20 kV. The phases formed during co-deposition process were identified using XRD at 25 mA current and 35 kV voltage.
    Matched MeSH terms: Steel
  13. Baharum MI, Kuppuswamy R, Rahman AA
    Forensic Sci Int, 2008 May 20;177(2-3):221-7.
    PMID: 18313246 DOI: 10.1016/j.forsciint.2008.01.004
    A study has been made of the characteristics of restoration of obliterated engraved marks on aluminium surfaces by etching technique. By etching different reagents on 0.61mm thick sheets of aluminium (99wt%) on which some engraved marks had been erased to different depths it was found that the reagent 60% hydrochloric acid and 40% sodium hydroxide on alternate swabbing on the surfaces was found to be the most sensitive one for these metal surfaces. This reagent was able to restore marks in the above plates erased down to 0.04mm below the bottom of the engraving. The marks also presented excellent contrast with the background. This reagent was further experimented with similar aluminium surfaces, but of relatively greater thickness of 1.5mm. It was noticed that the recovery depth increased slightly to 0.06mm; this suggested the dependence of recovery depth on the thickness of the sheet metal. Further, the depth of restoration decreased in cases where the original number was erased and over which a new number was engraved; the latter results are similar to those of steel surfaces reported earlier [M.A.M. Zaili, R. Kuppuswamy, H. Harun, Restoration of engraved marks on steel surfaces by etching technique, Forensic Sci. Int. 171 (2007) 27-32].
    Matched MeSH terms: Steel
  14. Yusof Abdullah, Abdul Razak Daud, Mohd Harun, Roslinda Shamsudin
    MyJurnal
    Al-Si/SiC composites with the fraction of 5 and 15 wt. % fine SiC particles were fabricated using stir casting process by which SiC powders were poured into aluminium melt and cast in a stainless steel mould to form ingot. Characterization by X-ray diffraction (XRD) analysis showed the presence of constituent and intermetallic materials in the composites. Microstructure study revealed that both fine and course particles scattered in the Al-Si matrix. The characterization of thermal properties showed that the thermal conductivity and coefficient of thermal expansion decreased with the increase in SiC content. The conductivity and expansion behavior is correlated to the microstructure and weight fraction of the SiC particles. Meanwhile, the hardness of the composite increased with the increasing of SiC particles in the composites.
    Matched MeSH terms: Stainless Steel
  15. Fathul Karim Sahrani, Zaharah Ibrahim, Madzlan Aziz, Adibah Yahya
    Corrosion caused by sulphate-reducing bacteria (SRB) isolated from seawater nearby to Pasir Gudang has been studied. The test coupon was a AISI 304 stainless steel. Potential and corrosion rate measurements were carried out in various types of culturing solutions, with SRB1, SRB2, combination of SRB1 & SRB2 and without SRBs inoculated (sterilized). From Tafel plots a higher corrosion rate has been found in medium inoculated with SRBs than that of the sterilized medium (control). When SRBs were present in the medium, the Tafel plot shifted towards more negative values (Ecorr was shifted to much less anodic values) and increase in current density compared to that of the sterilized medium (control). Localized corrosion was observed on the metal surface, and it was associated to the SRB activity. X-ray analysis (EDAX) showed that the corrosion product has higher content of sulphur for medium containing SRBs than that of the sterilized medium. X-Ray Diffraction analysis carried out on corrosion products which showed the presence of iron sulphide. This indicates the influence of the presence of SRB in corrosion process.
    Matched MeSH terms: Stainless Steel
  16. Fathul Karim Sahrani, Madzlan Abd. Aziz, Zaharah Ibrahim, Adibah Yahya
    The corrosion potential of AISI 304 stainless steel coupons influenced by sulphate-reducing bacteria (SRB) has been studied. Pure colony of SRB was isolated from the Malaysia Marine and Heavy Engineering, Pasir Gudang, Johor. Open circuit potential measurements were carried out in variable types of culturing solutions with SRB1, SRB2, combination of SRB1 & SRB2 and without SRBs inoculated. Results showed that the corrosion potential, Eoc increased in the presence of SRBs (in pure and mixed culture) compared to that of control. EDS analysis showed the strong peak of sulphur in coupon containing SRB cultures compared to the control. ESEM data showed that the high density cell of SRBs were associated with corroding sections of surface steel comparing with non-corroding sections for coupons immersed in VMNI medium containing SRBs.
    Matched MeSH terms: Stainless Steel; Steel
  17. Yin SH, Kuppuswamy R
    Forensic Sci Int, 2009 Jan 10;183(1-3):50-3.
    PMID: 19041202 DOI: 10.1016/j.forsciint.2008.10.009
    Chemical etching, which is the most sensitive method to recover obliterated serial numbers on metal surfaces, has been practised quite successfully in forensic science laboratories all over the world. A large number of etchants suitable for particular metal surfaces based on empirical studies is available in the literature. This article reviews the sensitivity and efficacy of some popular etchants for recovering obliterated marks on medium carbon steel (0.31% C with ferrite-pearlite microstructure) used in automobile parts. The experiments involved engraving these carbon steel plates with some alphanumeric characters using a computer controlled machine "Gravograph" and erasing them to several depths below the bottom of their engraving depth. Seven metallographic reagents of which most of them were copper containing compounds were chosen for etching. The erased plates were etched with every one of these etchants using swabbing method. The results have revealed that Fry's reagent comprising cupric chloride 90 g, hydrochloric acid 120 mL and water 100mL provided the necessary contrast and was concluded to be the most sensitive. The same reagent was recommended by earlier workers for revealing strain lines in steel surfaces. Earlier, another reagent containing 5 g copper sulphate, 60 mL water, 30 mL (conc.) ammonium hydroxide, and 60 mL (conc.) hydrochloric acid was proved to be more sensitive to restore erased marks on low carbon steel (0.1% C with ferrite-pearlite structure) [M.A.M. Zaili, R. Kuppuswamy, H. Harun, Restoration of engraved marks on steel surfaces by etching technique, Forensic Sci. Int. 171 (2007) 27-32]. Thus the sensitivity of the etching reagent on steel surfaces appeared to be dependent on the content of carbon in the steel.
    Matched MeSH terms: Steel
  18. Sri Asliza, M.A., Zaheruddin, K., Shahrizal, H.
    MyJurnal
    In this study, natural Hydroxyapatite (HA) was extracted from clean cow bone by treatment with NaOH and heating at high temperature before ground into fine powder. The HA powder were than mixed together with binder for several hours. Dense HA were formed in die steel mould by using uniaxially pressing method. Sample was sintered at different temperature 1150, 1200, 1250 and 1300°C for several hours. The phases of specimen were identified using X-ray diffraction (XRD). The mechanical properties were analyzed using three-point bending testing and the microstructure was observed by scanning electron microscopy. From XRD results, natural HA shows phase of pure HA up to 1250 o C and fracture strength results indicated that the mechanical properties of specimen increase as temperature increase. From microstructure observation using SEM, HA specimen shows initial stages of sintering process at temperature 1150°C and show changes in microstructure evolution as temperature increase up to 1300°C.
    Matched MeSH terms: Steel
  19. Hishamuddin Husain, Anasyida Abu Seman, Abdul Razak Daud, Muhamad Daud
    MyJurnal
    Even though a lot of new advanced materials have been developed nowadays, steel remains a major material in construction, automobiles, appliances, industrial machinery as well as in the nuclear industry. Due to steel easily corroded, a proper surface protection is required to avoid any failures and extended the life cycle of the components. Surface coating is an efficient and economical method to obtain desirable material surfaces properties. Hot dip aluminizing technique was utilized in this study. Experiments have been conducted on the mild steel substrates with 12mm diameter. Prior to hot dipping process, observation on grain growth at three different temperatures had also been conducted to understand the behaviour of steel under application of heat. The substrates were heated at 700ºC, 800ºC and 900ºC for 1 hour and the microstructure was analyzed. The temperature of 800C was chosen for hot dipping. The substrates were dipped into the molten aluminum maintained at temperature 800ºC for 2,4,6,8,10,15 and 20 minutes. Optical microscopy and energy dispersive X-ray spectroscopy were used in this investigation. From the microstructure observation, it showed the appearance of intermetallic layer covered by the top layer of Al on the mild steel substrate increased with the increase in dipping time ranging from 36 to 282μm. The result of EDX analysis revealed the existence of Fe and Al in form of Fe2Al5 phase for all the dipping time.
    Matched MeSH terms: Steel
  20. Takriff M, Masngut N, Kadhum A, Kalil M, Mohammad A
    Acetone-butanol-ethanol (ABE) fermentation from Palm Oil Mill Effluent (POME) by C. acetobutylicum NCIMB 13357 in an oscillatory flow bioreactor was investigated. Experimental works were conducted in a U-shaped stainless steel oscillatory flow bioreactor at oscillation frequency between 0.45-0.78 Hz and a constant amplitude of 12.5 mm. Fermentations were carried out for 72 hr at 35oC using palm oil mill effluent and reinforced clostridia medium as a growth medium in batch culture. Result of this investigation showed that POME is a viable media for ABE fermentation and oscillatory flow bioreactor has an excellent potential as an alternative fermentation device.
    Matched MeSH terms: Stainless Steel
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links