Displaying publications 1 - 20 of 146 in total

Abstract:
Sort:
  1. Talal M, Zaidan AA, Zaidan BB, Albahri AS, Alamoodi AH, Albahri OS, et al.
    J Med Syst, 2019 Jan 15;43(3):42.
    PMID: 30648217 DOI: 10.1007/s10916-019-1158-z
    The Internet of Things (IoT) has been identified in various applications across different domains, such as in the healthcare sector. IoT has also been recognised for its revolution in reshaping modern healthcare with aspiring wide range prospects, including economical, technological and social. This study aims to establish IoT-based smart home security solutions for real-time health monitoring technologies in telemedicine architecture. A multilayer taxonomy is driven and conducted in this study. In the first layer, a comprehensive analysis on telemedicine, which focuses on the client and server sides, shows that other studies associated with IoT-based smart home applications have several limitations that remain unaddressed. Particularly, remote patient monitoring in healthcare applications presents various facilities and benefits by adopting IoT-based smart home technologies without compromising the security requirements and potentially large number of risks. An extensive search is conducted to identify articles that handle these issues, related applications are comprehensively reviewed and a coherent taxonomy for these articles is established. A total number of (n = 3064) are gathered between 2007 and 2017 for most reliable databases, such as ScienceDirect, Web of Science and Institute of Electrical and Electronic Engineer Xplore databases. Then, the articles based on IoT studies that are associated with telemedicine applications are filtered. Nine articles are selected and classified into two categories. The first category, which accounts for 22.22% (n = 2/9), includes surveys on telemedicine articles and their applications. The second category, which accounts for 77.78% (n = 7/9), includes articles on the client and server sides of telemedicine architecture. The collected studies reveal the essential requirement in constructing another taxonomy layer and review IoT-based smart home security studies. Therefore, IoT-based smart home security features are introduced and analysed in the second layer. The security of smart home design based on IoT applications is an aspect that represents a crucial matter for general occupants of smart homes, in which studies are required to provide a better solution with patient security, privacy protection and security of users' entities from being stolen or compromised. Innovative technologies have dispersed limitations related to this matter. The existing gaps and trends in this area should be investigated to provide valuable visions for technical environments and researchers. Thus, 67 articles are obtained in the second layer of our taxonomy and are classified into six categories. In the first category, 25.37% (n = 17/67) of the articles focus on architecture design. In the second category, 17.91% (n = 12/67) includes security analysis articles that investigate the research status in the security area of IoT-based smart home applications. In the third category, 10.44% (n = 7/67) includes articles about security schemes. In the fourth category, 17.91% (n = 12/67) comprises security examination. In the fifth category, 13.43% (n = 9/67) analyses security protocols. In the final category, 14.92% (n = 10/67) analyses the security framework. Then, the identified basic characteristics of this emerging field are presented and provided in the following aspects. Open challenges experienced on the development of IoT-based smart home security are addressed to be adopted fully in telemedicine applications. Then, the requirements are provided to increase researcher's interest in this study area. On this basis, a number of recommendations for different parties are described to provide insights on the next steps that should be considered to enhance the security of smart homes based on IoT. A map matching for both taxonomies is developed in this study to determine the novel risks and benefits of IoT-based smart home security for real-time remote health monitoring within client and server sides in telemedicine applications.
    Matched MeSH terms: Wireless Technology
  2. Mamman M, Hanapi ZM, Abdullah A, Muhammed A
    PLoS One, 2019;14(1):e0210310.
    PMID: 30682038 DOI: 10.1371/journal.pone.0210310
    The increasing demand for network applications, such as teleconferencing, multimedia messaging and mobile TV, which have diverse requirements, has resulted in the introduction of Long Term Evolution (LTE) by the Third Generation Partnership Project (3GPP). LTE networks implement resource allocation algorithms to distribute radio resource to satisfy the bandwidth and delay requirements of users. However, the scheduling algorithm problem of distributing radio resources to users is not well defined in the LTE standard and thus considerably affects transmission order. Furthermore, the existing radio resource algorithm suffers from performance degradation under prioritised conditions because of the minimum data rate used to determine the transmission order. In this work, a novel downlink resource allocation algorithm that uses quality of service (QoS) requirements and channel conditions to address performance degradation is proposed. The new algorithm is formulated as an optimisation problem where network resources are allocated according to users' priority, whereas the scheduling algorithm decides on the basis of users' channel status to satisfy the demands of QoS. Simulation is used to evaluate the performance of the proposed algorithm, and results demonstrate that it performs better than do all other algorithms according to the measured metrics.
    Matched MeSH terms: Wireless Technology
  3. Pogorelov K, Suman S, Azmadi Hussin F, Saeed Malik A, Ostroukhova O, Riegler M, et al.
    J Appl Clin Med Phys, 2019 Aug;20(8):141-154.
    PMID: 31251460 DOI: 10.1002/acm2.12662
    Wireless capsule endoscopy (WCE) is an effective technology that can be used to make a gastrointestinal (GI) tract diagnosis of various lesions and abnormalities. Due to a long time required to pass through the GI tract, the resulting WCE data stream contains a large number of frames which leads to a tedious job for clinical experts to perform a visual check of each and every frame of a complete patient's video footage. In this paper, an automated technique for bleeding detection based on color and texture features is proposed. The approach combines the color information which is an essential feature for initial detection of frame with bleeding. Additionally, it uses the texture which plays an important role to extract more information from the lesion captured in the frames and allows the system to distinguish finely between borderline cases. The detection algorithm utilizes machine-learning-based classification methods, and it can efficiently distinguish between bleeding and nonbleeding frames and perform pixel-level segmentation of bleeding areas in WCE frames. The performed experimental studies demonstrate the performance of the proposed bleeding detection method in terms of detection accuracy, where we are at least as good as the state-of-the-art approaches. In this research, we have conducted a broad comparison of a number of different state-of-the-art features and classification methods that allows building an efficient and flexible WCE video processing system.
    Matched MeSH terms: Wireless Technology
  4. Al-Qaysi ZT, Zaidan BB, Zaidan AA, Suzani MS
    Comput Methods Programs Biomed, 2018 Oct;164:221-237.
    PMID: 29958722 DOI: 10.1016/j.cmpb.2018.06.012
    CONTEXT: Intelligent wheelchair technology has recently been utilised to address several mobility problems. Techniques based on brain-computer interface (BCI) are currently used to develop electric wheelchairs. Using human brain control in wheelchairs for people with disability has elicited widespread attention due to its flexibility.

    OBJECTIVE: This study aims to determine the background of recent studies on wheelchair control based on BCI for disability and map the literature survey into a coherent taxonomy. The study intends to identify the most important aspects in this emerging field as an impetus for using BCI for disability in electric-powered wheelchair (EPW) control, which remains a challenge. The study also attempts to provide recommendations for solving other existing limitations and challenges.

    METHODS: We systematically searched all articles about EPW control based on BCI for disability in three popular databases: ScienceDirect, IEEE and Web of Science. These databases contain numerous articles that considerably influenced this field and cover most of the relevant theoretical and technical issues.

    RESULTS: We selected 100 articles on the basis of our inclusion and exclusion criteria. A large set of articles (55) discussed on developing real-time wheelchair control systems based on BCI for disability signals. Another set of articles (25) focused on analysing BCI for disability signals for wheelchair control. The third set of articles (14) considered the simulation of wheelchair control based on BCI for disability signals. Four articles designed a framework for wheelchair control based on BCI for disability signals. Finally, one article reviewed concerns regarding wheelchair control based on BCI for disability signals.

    DISCUSSION: Since 2007, researchers have pursued the possibility of using BCI for disability in EPW control through different approaches. Regardless of type, articles have focused on addressing limitations that impede the full efficiency of BCI for disability and recommended solutions for these limitations.

    CONCLUSIONS: Studies on wheelchair control based on BCI for disability considerably influence society due to the large number of people with disability. Therefore, we aim to provide researchers and developers with a clear understanding of this platform and highlight the challenges and gaps in the current and future studies.

    Matched MeSH terms: Wireless Technology
  5. Mohsin AH, Zaidan AA, Zaidan BB, Albahri AS, Albahri OS, Alsalem MA, et al.
    J Med Syst, 2018 Oct 16;42(12):238.
    PMID: 30327939 DOI: 10.1007/s10916-018-1104-5
    The development of wireless body area sensor networks is imperative for modern telemedicine. However, attackers and cybercriminals are gradually becoming aware in attacking telemedicine systems, and the black market value of protected health information has the highest price nowadays. Security remains a formidable challenge to be resolved. Intelligent home environments make up one of the major application areas of pervasive computing. Security and privacy are the two most important issues in the remote monitoring and control of intelligent home environments for clients and servers in telemedicine architecture. The personal authentication approach that uses the finger vein pattern is a newly investigated biometric technique. This type of biometric has many advantages over other types (explained in detail later on) and is suitable for different human categories and ages. This study aims to establish a secure verification method for real-time monitoring systems to be used for the authentication of patients and other members who are working in telemedicine systems. The process begins with the sensor based on Tiers 1 and 2 (client side) in the telemedicine architecture and ends with patient verification in Tier 3 (server side) via finger vein biometric technology to ensure patient security on both sides. Multilayer taxonomy is conducted in this research to attain the study's goal. In the first layer, real-time remote monitoring studies based on the sensor technology used in telemedicine applications are reviewed and analysed to provide researchers a clear vision of security and privacy based on sensors in telemedicine. An extensive search is conducted to identify articles that deal with security and privacy issues, related applications are reviewed comprehensively and a coherent taxonomy of these articles is established. ScienceDirect, IEEE Xplore and Web of Science databases are checked for articles on mHealth in telemedicine based on sensors. A total of 3064 papers are collected from 2007 to 2017. The retrieved articles are filtered according to the security and privacy of telemedicine applications based on sensors. Nineteen articles are selected and classified into two categories. The first category, which accounts for 57.89% (n = 11/19), includes surveys on telemedicine articles and their applications. The second category, accounting for 42.1% (n = 8/19), includes articles on the three-tiered architecture of telemedicine. The collected studies reveal the essential need to construct another taxonomy layer and review studies on finger vein biometric verification systems. This map-matching for both taxonomies is developed for this study to go deeply into the sensor field and determine novel risks and benefits for patient security and privacy on client and server sides in telemedicine applications. In the second layer of our taxonomy, the literature on finger vein biometric verification systems is analysed and reviewed. In this layer, we obtain a final set of 65 articles classified into four categories. In the first category, 80% (n = 52/65) of the articles focus on development and design. In the second category, 12.30% (n = 8/65) includes evaluation and comparative articles. These articles are not intensively included in our literature analysis. In the third category, 4.61% (n = 3/65) includes articles about analytical studies. In the fourth category, 3.07% (n = 2/65) comprises reviews and surveys. This study aims to provide researchers with an up-to-date overview of studies that have been conducted on (user/patient) authentication to enhance the security level in telemedicine or any information system. In the current study, taxonomy is presented by explaining previous studies. Moreover, this review highlights the motivations, challenges and recommendations related to finger vein biometric verification systems and determines the gaps in this research direction (protection of finger vein templates in real time), which represent a new research direction in this area.
    Matched MeSH terms: Wireless Technology
  6. Mohammad Yusof NAD, Karupiah K, Mohd Tamrin SB, Rasdi I, How V, Sambasivam S, et al.
    PLoS One, 2021;16(10):e0258796.
    PMID: 34665845 DOI: 10.1371/journal.pone.0258796
    Traffic police riders are exposed to prolonged static postures causing significant angular deviation of the musculoskeletal, including the lumbar angle (L1-L5). This postural alteration contributes to awkward posture, musculoskeletal disorders and spinal injury, especially in the lower back area, as it is one of the most severe modern diseases nowadays. Thus, the study aimed to evaluate the effect of lumbar support with a built-in massager system on spinal angle profiles among traffic police riders. A randomised controlled trial (pre-testpost-test control design) was used to assess spinal angle pattern while riding the high-powered motorcycle for 20 minutes. Twenty-four traffic police riders were randomly selected to participate and 12 riders were assigned to the control group and 12 riders to the experimental group. The pre-test and post-test were conducted at a one-week interval. Each participant was required to wear a TruPosture Smart Shirt (to monitor spinal posture). The TruPosture Apps recorded the spinal angle pattern. The data indicated that the police riders using motorcycle seat with lumbar support and built-in massager system showed a huge improvement in maintaining posture which only involves slight spinal angle deviation changes from the spinal reference angle throughout the 20 minutes ride. The data collected then were analysed using the Mann-Whitney test and Wilcoxon signed-ranked test to verify a statistically significant difference between and within the control and experimental groups. There were significant differences in all sensors between the control group and experimental groups (p<0.05) and within the experimental group. According to the findings, it can be said that the ergonomic intervention prototype (lumbar support with built-in massager system) successfully helps to maintain and improve the natural curve of the spinal posture. This indirectly would reduce the risk of developing musculoskeletal disorders and spinal injury among traffic police riders.
    Matched MeSH terms: Wireless Technology
  7. Albahri OS, Albahri AS, Mohammed KI, Zaidan AA, Zaidan BB, Hashim M, et al.
    J Med Syst, 2018 Mar 22;42(5):80.
    PMID: 29564649 DOI: 10.1007/s10916-018-0943-4
    The new and ground-breaking real-time remote monitoring in triage and priority-based sensor technology used in telemedicine have significantly bounded and dispersed communication components. To examine these technologies and provide researchers with a clear vision of this area, we must first be aware of the utilised approaches and existing limitations in this line of research. To this end, an extensive search was conducted to find articles dealing with (a) telemedicine, (b) triage, (c) priority and (d) sensor; (e) comprehensively review related applications and establish the coherent taxonomy of these articles. ScienceDirect, IEEE Xplore and Web of Science databases were checked for articles on triage and priority-based sensor technology in telemedicine. The retrieved articles were filtered according to the type of telemedicine technology explored. A total of 150 articles were selected and classified into two categories. The first category includes reviews and surveys of triage and priority-based sensor technology in telemedicine. The second category includes articles on the three-tiered architecture of telemedicine. Tier 1 represents the users. Sensors acquire the vital signs of the users and send them to Tier 2, which is the personal gateway that uses local area network protocols or wireless body area network. Medical data are sent from Tier 2 to Tier 3, which is the healthcare provider in medical institutes. Then, the motivation for using triage and priority-based sensor technology in telemedicine, the issues related to the obstruction of its application and the development and utilisation of telemedicine are examined on the basis of the findings presented in the literature.
    Matched MeSH terms: Wireless Technology
  8. Balachandran R, Prepageran N, Prepagaran N, Rahmat O, Zulkiflee AB, Hufaida KS
    J Laryngol Otol, 2012 Apr;126(4):345-8.
    PMID: 22310164 DOI: 10.1017/S0022215112000047
    The Bluetooth wireless headset has been promoted as a 'hands-free' device with a low emission of electromagnetic radiation.
    Matched MeSH terms: Wireless Technology*
  9. Gouwanda D, Senanayake SM
    J Biomech, 2011 Mar 15;44(5):972-8.
    PMID: 21306714 DOI: 10.1016/j.jbiomech.2010.12.013
    Injury to a lower limb may disrupt natural walking and cause asymmetrical gait, therefore assessing the gait asymmetry has become one of the important procedures in gait analysis. This paper proposes the use of wireless gyroscopes as a new instrument to determine gait asymmetry. It also introduces two novel approaches: normalized cross-correlations (Cc(norm)) and Normalized Symmetry Index (SI(norm)). Cc(norm) evaluates the waveform patterns generated by the lower limb in each gait cycle. SI(norm) provides indications on the timing and magnitude of the bilateral differences between the limbs while addressing the drawbacks of the conventional methods. One-way ANOVA test reveals that Cc(norm) can be considered as single value indicator that determines the gait asymmetry (p<0.01). The experiment results showed that SI(norm) in asymmetrical gait were different from normal gait. SI(norm) in asymmetrical gait were found to be approximately 20% greater than SI(norm) in normal gait during pre-swing and initial swing.
    Matched MeSH terms: Wireless Technology
  10. Razzaque MA, Javadi SS, Coulibaly Y, Hira MT
    Sensors (Basel), 2014 Dec 29;15(1):440-64.
    PMID: 25551485 DOI: 10.3390/s150100440
    Wireless body sensor networks (WBSNs) for healthcare and medical applications are real-time and life-critical infrastructures, which require a strict guarantee of quality of service (QoS), in terms of latency, error rate and reliability. Considering the criticality of healthcare and medical applications, WBSNs need to fulfill users/applications and the corresponding network's QoS requirements. For instance, for a real-time application to support on-time data delivery, a WBSN needs to guarantee a constrained delay at the network level. A network coding-based error recovery mechanism is an emerging mechanism that can be used in these systems to support QoS at very low energy, memory and hardware cost. However, in dynamic network environments and user requirements, the original non-adaptive version of network coding fails to support some of the network and user QoS requirements. This work explores the QoS requirements of WBSNs in both perspectives of QoS. Based on these requirements, this paper proposes an adaptive network coding-based, QoS-aware error recovery mechanism for WBSNs. It utilizes network-level and user-/application-level information to make it adaptive in both contexts. Thus, it provides improved QoS support adaptively in terms of reliability, energy efficiency and delay. Simulation results show the potential of the proposed mechanism in terms of adaptability, reliability, real-time data delivery and network lifetime compared to its counterparts.
    Matched MeSH terms: Wireless Technology*
  11. Ahsan MR, Islam MT, Habib Ullah M, Mahadi WN, Latef TA
    ScientificWorldJournal, 2014;2014:909854.
    PMID: 25165750 DOI: 10.1155/2014/909854
    This paper presents a compact sized inset-fed rectangular microstrip patch antenna embedded with double-P slots. The proposed antenna has been designed and fabricated on ceramic-PTFE composite material substrate of high dielectric constant value. The measurement results from the fabricated prototype of the antenna show -10 dB reflection coefficient bandwidths of 200 MHz and 300 MHz with center resonant frequency of 1.5 GHz and 4 GHz, respectively. The fabricated antenna has attained gains of 3.52 dBi with 81% radiation efficiency and 5.72 dBi with 87% radiation efficiency for lower band and upper band, respectively. The measured E- and H-plane radiation patterns are also presented for better understanding. Good agreement between the simulation and measurement results and consistent radiation patterns make the proposed antenna suitable for GPS and C-band applications.
    Matched MeSH terms: Wireless Technology/instrumentation*
  12. Mutashar S, Hannan MA, Samad SA, Hussain A
    Sensors (Basel), 2014;14(7):11522-41.
    PMID: 24984057 DOI: 10.3390/s140711522
    The use of wireless communication using inductive links to transfer data and power to implantable microsystems to stimulate and monitor nerves and muscles is increasing. This paper deals with the development of the theoretical analysis and optimization of an inductive link based on coupling and on spiral circular coil geometry. The coil dimensions offer 22 mm of mutual distance in air. However, at 6 mm of distance, the coils offer a power transmission efficiency of 80% in the optimum case and 73% in the worst case via low input impedance, whereas, transmission efficiency is 45% and 32%, respectively, via high input impedance. The simulations were performed in air and with two types of simulated human biological tissues such as dry and wet-skin using a depth of 6 mm. The performance results expound that the combined magnitude of the electric field components surrounding the external coil is approximately 98% of that in air, and for an internal coil, it is approximately 50%, respectively. It can be seen that the gain surrounding coils is almost constant and confirms the omnidirectional pattern associated with such loop antennas which reduces the effect of non-alignment between the two coils. The results also show that the specific absorption rate (SAR) and power loss within the tissue are lower than that of the standard level. Thus, the tissue will not be damaged anymore.
    Matched MeSH terms: Wireless Technology/instrumentation*
  13. Zubair S, Fisal N, Baguda YS, Saleem K
    Sensors (Basel), 2013;13(10):13005-38.
    PMID: 24077319 DOI: 10.3390/s131013005
    Interest in the cognitive radio sensor network (CRSN) paradigm has gradually grown among researchers. This concept seeks to fuse the benefits of dynamic spectrum access into the sensor network, making it a potential player in the next generation (NextGen) network, which is characterized by ubiquity. Notwithstanding its massive potential, little research activity has been dedicated to the network layer. By contrast, we find recent research trends focusing on the physical layer, the link layer and the transport layers. The fact that the cross-layer approach is imperative, due to the resource-constrained nature of CRSNs, can make the design of unique solutions non-trivial in this respect. This paper seeks to explore possible design opportunities with wireless sensor networks (WSNs), cognitive radio ad-hoc networks (CRAHNs) and cross-layer considerations for implementing viable CRSN routing solutions. Additionally, a detailed performance evaluation of WSN routing strategies in a cognitive radio environment is performed to expose research gaps. With this work, we intend to lay a foundation for developing CRSN routing solutions and to establish a basis for future work in this area.
    Matched MeSH terms: Wireless Technology/instrumentation*
  14. Rassam MA, Zainal A, Maarof MA
    Sensors (Basel), 2013;13(8):10087-122.
    PMID: 23966182 DOI: 10.3390/s130810087
    Wireless Sensor Networks (WSNs) are important and necessary platforms for the future as the concept "Internet of Things" has emerged lately. They are used for monitoring, tracking, or controlling of many applications in industry, health care, habitat, and military. However, the quality of data collected by sensor nodes is affected by anomalies that occur due to various reasons, such as node failures, reading errors, unusual events, and malicious attacks. Therefore, anomaly detection is a necessary process to ensure the quality of sensor data before it is utilized for making decisions. In this review, we present the challenges of anomaly detection in WSNs and state the requirements to design efficient and effective anomaly detection models. We then review the latest advancements of data anomaly detection research in WSNs and classify current detection approaches in five main classes based on the detection methods used to design these approaches. Varieties of the state-of-the-art models for each class are covered and their limitations are highlighted to provide ideas for potential future works. Furthermore, the reviewed approaches are compared and evaluated based on how well they meet the stated requirements. Finally, the general limitations of current approaches are mentioned and further research opportunities are suggested and discussed.
    Matched MeSH terms: Wireless Technology/instrumentation*
  15. Gouwanda D, Senanayake SM
    J Med Eng Technol, 2011 Nov;35(8):432-40.
    PMID: 22074136 DOI: 10.3109/03091902.2011.627080
    A real-time gait monitoring system that incorporates an immediate and periodical assessment of gait asymmetry is described. This system was designed for gait analysis and rehabilitation of patients with pathologic gait. It employs wireless gyroscopes to measure the angular rate of the thigh and shank in real time. Cross-correlation of the lower extremity (Cc(norm)), and normalized Symmetry Index (SI(norm)) are implemented as new approaches to periodically determine the gait asymmetry in each gait cycle. Cc(norm) evaluates the signal patterns measured by wireless gyroscopes in each gait cycle. SI(norm) determines the movement differences between the left and right limb. An experimental study was conducted to examine the viability of these methods. Artificial asymmetrical gait was simulated by placing a load on one side of the limbs. Results showed that there were significant differences between the normal gait and asymmetrical gait (p < 0.01). They also indicated that the system worked well in periodically assessing the gait asymmetry.
    Matched MeSH terms: Wireless Technology/instrumentation*
  16. Yang Y, Wei X, Zhang N, Zheng J, Chen X, Wen Q, et al.
    Nat Commun, 2021 08 12;12(1):4876.
    PMID: 34385436 DOI: 10.1038/s41467-021-25075-8
    While the printed circuit board (PCB) has been widely considered as the building block of integrated electronics, the world is switching to pursue new ways of merging integrated electronic circuits with textiles to create flexible and wearable devices. Herein, as an alternative for PCB, we described a non-printed integrated-circuit textile (NIT) for biomedical and theranostic application via a weaving method. All the devices are built as fibers or interlaced nodes and woven into a deformable textile integrated circuit. Built on an electrochemical gating principle, the fiber-woven-type transistors exhibit superior bending or stretching robustness, and were woven as a textile logical computing module to distinguish different emergencies. A fiber-type sweat sensor was woven with strain and light sensors fibers for simultaneously monitoring body health and the environment. With a photo-rechargeable energy textile based on a detailed power consumption analysis, the woven circuit textile is completely self-powered and capable of both wireless biomedical monitoring and early warning. The NIT could be used as a 24/7 private AI "nurse" for routine healthcare, diabetes monitoring, or emergencies such as hypoglycemia, metabolic alkalosis, and even COVID-19 patient care, a potential future on-body AI hardware and possibly a forerunner to fabric-like computers.
    Matched MeSH terms: Wireless Technology/instrumentation*
  17. Al-Ani AK, Anbar M, Manickam S, Al-Ani A
    PLoS One, 2019;14(4):e0214518.
    PMID: 30939154 DOI: 10.1371/journal.pone.0214518
    An efficiently unlimited address space is provided by Internet Protocol version 6 (IPv6). It aims to accommodate thousands of hundreds of unique devices on a similar link. This can be achieved through the Duplicate Address Detection (DAD) process. It is considered one of the core IPv6 network's functions. It is implemented to make sure that IP addresses do not conflict with each other on the same link. However, IPv6 design's functions are exposed to security threats like the DAD process, which is vulnerable to Denial of Service (DoS) attack. Such a threat prevents the host from configuring its IP address by responding to each Neighbor Solicitation (NS) through fake Neighbor Advertisement (NA). Various mechanisms have been proposed to secure the IPv6 DAD procedure. The proposed mechanisms, however, suffer from complexity, high processing time, and the consumption of more resources. The experiments-based findings revealed that all the existing mechanisms had failed to secure the IPv6 DAD process. Therefore, DAD-match security technique is proposed in this study to efficiently secure the DAD process consuming less processing time. DAD-match is built based on SHA-3 to hide the exchange tentative IP among hosts throughout the process of DAD in an IPv6 link-local network. The obtained experimental results demonstrated that the DAD-match security technique achieved less processing time compared with the existing mechanisms as it can resist a range of different threats like collision and brute-force attacks. The findings concluded that the DAD-match technique effectively prevents the DoS attack during the DAD process. The DAD-match technique is implemented on a small area IPv6 network; hence, the author future work is to implement and test the DAD-match technique on a large area IPv6 network.
    Matched MeSH terms: Wireless Technology*
  18. Ganasegeran K, Renganathan P, Rashid A, Al-Dubai SA
    Int J Med Inform, 2017 01;97:145-151.
    PMID: 27919374 DOI: 10.1016/j.ijmedinf.2016.10.013
    BACKGROUND: The dawn of m-Health facilitates new horizons of professional communication through WhatsApp, allowing health professionals to interact fast and efficiently for effective patient management. This preliminary study aimed to investigate perceived benefits, if any, of WhatsApp use across general medical and emergency teams during clinical practice in Malaysia.

    METHODS: A cross-sectional study was conducted in a universal sample of 307 health professionals comprising of nurses, medical assistants, medical residents, medical officers and physicians across medical and casualty departments in a Malaysian public hospital. The self-administered questionnaire consisted of items on socio-demographics, WhatsApp usage characteristics and the type of communication events during clinical practice.

    RESULTS: The majority of respondents (68.4%) perceived WhatsApp as beneficial during clinical practice. In multivariate analysis, perceived benefits was significantly higher amongst the clinical management group (aOR=2.6, 95% CI 1.5-4.6, p=0.001), those using WhatsApp for >12months (aOR=1.7, 95% CI 1.0-3.0, p=0.047), those receiving response ≤15min to a new communication (aOR=1.9, 95% CI 1.1-3.2, p=0.017), and frequent information giving events (aOR=2.4, 95% CI 1.2-4.8, p=0.016).

    CONCLUSION: Perceived benefits of WhatsApp use in clinical practice was significantly associated with usage characteristics and type of communication events. This study lays the foundation for quality improvement innovations in patient management delivered through m-Health technology.

    Matched MeSH terms: Wireless Technology*
  19. Khan A, Khan M, Ahmed S, Abd Rahman MA, Khan M
    PLoS One, 2019;14(7):e0219459.
    PMID: 31314772 DOI: 10.1371/journal.pone.0219459
    Underwater sensor networks (UWSNs) are ad-hoc networks which are deployed at rivers, seas and oceans to explore and monitor the phenomena such as pollution control, seismic activities and petroleum mining etc. The sensor nodes of UWSNs have limited charging capabilities. UWSNs networks are generally operated under two deployment mechanisms i.e localization and non-localization based. However, in both the mechanisms, balanced energy utilization is a challenging issue. Inefficient usage of energy significantly affects stability period, packet delivery ratio, end-to-end delay, path loss and throughput of a network. To efficiently utilize and harvest energy, this paper present a novel scheme called EH-ARCUN (Energy Harvesting Analytical approach towards Reliability with Cooperation for UWSNs) based on cooperation with energy harvesting. The scheme employs Amplify-and-Forward (AF) technique at relay nodes for data forwarding and Fixed Combining Ratio (FCR) technique at destination node to select accurate signal. The proposed technique selects relay nodes among its neighbor nodes based on harvested energy level. Most cooperation-based UWSN routing techniques do not exhibit energy harvesting mechanism at the relay nodes. EH-ARCUN deploys piezoelectric energy harvesting at relay nodes to improve the working capabilities of sensors in UWSNs. The proposed scheme is an extension of our previously implemented routing scheme called ARCUN for UWSNs. Performance of the proposed scheme is compared with ARCUN and RACE (Reliability and Adaptive Cooperation for efficient Underwater sensor Networks) schemes in term of stability period, packet delivery ratio, network throughput and path loss. Extensive simulation results show that EH-ARCUN performs better than both previous schemes in terms of the considered parameters.
    Matched MeSH terms: Wireless Technology
  20. Aslina A. Bakar, Amirul A. Mustafa, Ahmad R. Razali, Norhayati Mutalib, Amirudin Ibrahim
    ESTEEM Academic Journal, 2020;16(2):75-87.
    MyJurnal
    This study aims to investigate the bending effects on the flexible wearable antenna by using copper nanowires and polydimethylsiloxane (PDMS). This project focuses on the bending effect on the proposed wearable antenna in the presence of skin tissue and at free space. The radiation characteristics were simulated and analyzed when the antenna was under flat and bent conditions. The performance result of return loss and radiation pattern (Efield and H-field) of proposed wearable antenna was analyzed. The material for the proposed antenna is designed to be flexible and wearable for the application of body-centric wireless communication (BCWCs) at the frequency of 2.45 GHz with the approval specifications of industrial, scientific and medical (ISM) band. Radiator for the proposed wearable antenna is fabricated using copper nanowire, and the antenna substrate is by using polydimethylsiloxane (PDMS). The performance result of the proposed wearable antenna was simulated by using CST microwave studio. From the simulated result for different bending angles, a conclusion was drawn that bending of structure can improve the impedance matching and return loss during the bent condition. However, the resonant frequency tends to shift as the antenna is bent up to 50°. At the critical angle of 70°, the frequency is shifted to a lower frequency.
    Matched MeSH terms: Wireless Technology
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links