Displaying publications 221 - 240 of 330 in total

Abstract:
Sort:
  1. Nur Azida Che Lah, Muhamad Hellmy Hussin
    MyJurnal
    Titanium (Ti) and Ti-based alloys presence the most widely applied as advanced biomaterials
    in biomedical implant applications. Moreover, these alloys are known to be the most
    valuable metallic materials including spinal cord surgical treatment. It becomes an interest
    due to its advantages compared to others, including its bio compatibility and corrosion
    resistant. However, an issue arises when it comes for permanent implant application as
    the alloy has a possible toxic effect produced from chemical reaction between body fluid
    environments with alloys chemical compositions. It also relies on the performance of
    neighbouring bone tissue to integrate with the implant surface. Abnormalities usually
    happen when surrounding tissue shows poor responses and rejection of implants that would
    leads to body inflammation. These cause an increase in foreign body reaction leading to
    severe body tissue response and thus, loosening of the implant. Corrosion effects and
    biocompatibility behaviour of implantation usage also become one of the reasons of
    implant damage. Here, this paper reviews the importance of using Ti and Ti-based alloys
    in biomedical implantation, especially in orthopaedic spinal cord injury. It also reviews the
    basic aspects of corrosion effects that lead to implant mechanical damage, poor response
    of body rejection and biocompatibility behaviour of implantation usage.
    Matched MeSH terms: Biocompatible Materials
  2. Leanne Britcher, Sunil Kumar, Hans J. Griesser, Kim S. Siow
    Sains Malaysiana, 2018;47:1913-1922.
    In this report, we demonstrate that continuous improvement in XPS instruments and the calibration standards as well
    as analysis with standard component-fitting procedures can be used to determine the binding energies of compounds
    containing phosphorus and sulfur of different oxidation states with higher confidence. Based on such improved XPS
    analyses, the binding energies (BEs) of S2p signals for sulfur of increasing oxidation state are determined to be 166-167.5
    eV for S=O in dimethyl sulfoxide, 168.1 eV for S=O2
    in polysulfone, 168.4 eV for SO3
    in polystyrene sulfonate and 168.8
    eV for SO4
    in chondroitin sulfate. The BEs of P2p signals show the following values: 132.9 eV for PO3
    in triisopropyl
    phosphite, 133.3 eV for PO4
    in glycerol phosphate, 133.5 eV for PO4
    in sodium tripolyphosphate and 134.0 eV for PO4
    in sodium hexametaphosphate. These results showed that there are only small increases in the binding energy when
    additional oxygen atoms are added to the S-O chemical group. A similar result is obtained when the fourth oxygen or
    poly-phosphate environment is added to the phosphorus compound. These BE values are useful to researchers involved
    in identifying oxidation states of phosphorus and sulfur atoms commonly observed on modified surfaces and interfaces
    found in applications such as biomaterials, super-capacitors and catalysis.
    Matched MeSH terms: Biocompatible Materials
  3. Amjad M, Badshah S, Rafique AF, Adil Khattak M, Khan RU, Abdullah Harasani WI
    Materials (Basel), 2020 May 16;13(10).
    PMID: 32429420 DOI: 10.3390/ma13102299
    Implants are widely used in the human body for the replacement of affected bones. Fatigue failure is one of the serious concerns for implants. Therefore, understanding of the underlying mechanism leading to fatigue failure is important for the longevity of biomaterial implants. In this paper, the fracture toughness and fatigue crack growth of titanium alloy biomaterial Ti-27Nb has been experimentally investigated. The Ti-27Nb material is tested for fatigue crack growth in different environmental conditions representing the ambient and in vitro environments for 504 hours and 816 hours, respectively. Fractography of the tested specimen is conducted using Scanning Electron Microscope (SEM). The results of the fatigue crack growth propagation of the ambient and in vitro samples are similar in the Paris crack growth region. However, in the threshold region, the crack growth rate is higher for the Simulated Body Fluid (SBF) treated specimen. The fracture surface morphology of in vitro samples shows brittle fracture as compared to ambient specimens with significant plasticity and striations marks. It is proposed that a similar investigation may be conducted with specimens treated in SBF for prolonged periods to further ascertain the findings of this study.
    Matched MeSH terms: Biocompatible Materials
  4. Boukari Y, Qutachi O, Scurr DJ, Morris AP, Doughty SW, Billa N
    J Biomater Sci Polym Ed, 2017 Nov;28(16):1966-1983.
    PMID: 28777694 DOI: 10.1080/09205063.2017.1364100
    The development of patient-friendly alternatives to bone-graft procedures is the driving force for new frontiers in bone tissue engineering. Poly (dl-lactic-co-glycolic acid) (PLGA) and chitosan are well-studied and easy-to-process polymers from which scaffolds can be fabricated. In this study, a novel dual-application scaffold system was formulated from porous PLGA and protein-loaded PLGA/chitosan microspheres. Physicochemical and in vitro protein release attributes were established. The therapeutic relevance, cytocompatibility with primary human mesenchymal stem cells (hMSCs) and osteogenic properties were tested. There was a significant reduction in burst release from the composite PLGA/chitosan microspheres compared with PLGA alone. Scaffolds sintered from porous microspheres at 37 °C were significantly stronger than the PLGA control, with compressive strengths of 0.846 ± 0.272 MPa and 0.406 ± 0.265 MPa, respectively (p 
    Matched MeSH terms: Biocompatible Materials/metabolism; Biocompatible Materials/pharmacology*; Biocompatible Materials/chemistry*
  5. Ahmad P, Alam MK, Jakubovics NS, Schwendicke F, Asif JA
    J Dent Res, 2019 Dec;98(13):1425-1436.
    PMID: 31746684 DOI: 10.1177/0022034519880544
    Since its inception in 1919, the Journal of Dental Research has continually published high-quality articles that span the breadth of research topics relevant to dentistry, oral surgery, and medicine. As part of the journal's centennial celebration, we conducted an electronic search on Scopus to identify and analyze the top 100 most cited articles from 1919 to 2018. Since Scopus does not capture older citations, we conducted an additional analysis by Google Scholar to identify key articles published in the first 50 y of the journal. Based on Scopus, the articles were ranked in descending order per their citation counts. The citation counts of the 100 most cited articles varied from 262 to 1,503. The year in which the largest number of top 100 articles were published was 2004 (n = 6). Within the top 100, the majority of articles originated from the United States (n = 52). Research Reports-Biomaterials & Bioengineering was the most frequent category of cited articles (n = 35). There was no significant association between total citation count and time since publication (correlation coefficient = -0.051, P = 0.656). However, there was a significant negative association of citation density (correlation coefficient = -0.610, P < 0.01) with time since publication. Our analyses demonstrate the broad reach of the journal and the dynamics in citation patterns and research agenda over its 100-y history. There is considerable evidence of the high variance in research output, when measured via citations, across the globe. Moreover, it remains unclear how patients' priorities and dental health care needs are aligned with the perceived influence of single research pieces identified by our search. Our findings may help to inspire future research in tackling these inequalities and highlight the need for conceptualizing research priorities.
    Matched MeSH terms: Biocompatible Materials
  6. Bapat RA, Bedia SV, Bedia AS, Yang HJ, Dharmadhikari S, Abdulla AM, et al.
    Environ Res, 2023 Dec 01;238(Pt 1):116971.
    PMID: 37717805 DOI: 10.1016/j.envres.2023.116971
    Curcumin is a natural herb and polyphenol that is obtained from the medicinal plant Curcuma longa. It's anti-bacterial, anti-inflammatory, anti-cancer, anti-mutagenic, antioxidant and antifungal properties can be leveraged to treat a myriad of oral and systemic diseases. However, natural curcumin has weak solubility, limited bioavailability and undergoes rapid degradation, which severely limits its therapeutic potential. To overcome these drawbacks, nanocurcumin (nCur) formulations have been developed for improved biomaterial delivery and enhanced treatment outcomes. This novel biomaterial holds tremendous promise for the treatment of various oral diseases, the majority of which are caused by dental biofilm. These include dental caries, periodontal disease, root canal infection and peri-implant diseases, as well as other non-biofilm mediated oral diseases such as oral cancer and oral lichen planus. A number of in-vitro studies have demonstrated the antibacterial efficacy of nCur in various formulations against common oral pathogens such as S. mutans, P. gingivalis and E. faecalis, which are strongly associated with dental caries, periodontitis and root canal infection, respectively. In addition, some clinical studies were suggestive of the notion that nCur can indeed enhance the clinical outcomes of oral diseases such as periodontitis and oral lichen planus, but the level of evidence was very low due to the small number of studies and the methodological limitations of the available studies. The versatility of nCur to treat a diverse range of oral diseases augurs well for its future in dentistry, as reflected by rapid pace in which studies pertaining to this topic are published in the scientific literature. In order to keep abreast of the latest development of nCur in dentistry, this narrative review was undertaken. The aim of this narrative review is to provide a contemporaneous update of the chemistry, properties, mechanism of action, and scientific evidence behind the usage of nCur in dentistry.
    Matched MeSH terms: Biocompatible Materials
  7. Rohtagi P, Garg U, Triveni, Jain N, Pandey M, Amin MCIM, et al.
    Biomater Adv, 2024 Feb;157:213733.
    PMID: 38118207 DOI: 10.1016/j.bioadv.2023.213733
    Cancer has become a major public health issue leading to one of the foremost causes of morbidity and death in the world. Despite the current advances in diagnosis using modern technologies and treatment via surgery or chemo- and radio-therapies, severe side effects or after-effects limit the application of these treatment modalities. Novel drug delivery systems have shown the potential to deliver chemotherapeutics directly to cancer cells, thus minimizing unnecessary exposure to healthy cells. Concurrently, to circumvent difficulties associated with conventional deliveries of cancer therapeutics, natural polysaccharides have gained attention for the fabrication of such deliveries owing to biocompatibility, low toxicity, and biodegradability. It has been exhibited that natural polysaccharides can deliver high therapeutic concentrations of the entrapped drug to the target cells by sustained and targeted release. Considering the immense potential of natural polymers, the present work focuses on naturally generated biopolymer carriers based on chitosan and hyaluronic acid. This review delineated on the role of chitosan and its derivation from renewable resources as a biocompatible, biodegradable, nonimmunogenic material with notable antitumor activity as a drug delivery carrier in oncotherapy. Moreover, hyaluronic acid, itself by its structure or when linked with other molecules contributes to developing promising pharmaceutical delivery systems to setback the restrictions related to conventional cancer treatment.
    Matched MeSH terms: Biocompatible Materials
  8. Alqarni LS, Algethami JS, El Kaim Billah R, Alorabi AQ, Alnaam YA, Algethami FK, et al.
    Int J Biol Macromol, 2024 Apr;263(Pt 2):129989.
    PMID: 38354916 DOI: 10.1016/j.ijbiomac.2024.129989
    In this study, the synthesis and experimental theoretical evaluation of a new chitosan/alginate/hydrozyapatite nanocomposite doped with Mn2 and Fe2O3 for Cr removal was reported. The physicochemical properties of the obtained materials were analyzed using the following methods: SEM-EDX, XRD, FTIR, XPS, pH drift measurements, and thermal analysis. The adsorption properties were estimated based on equilibrium and adsorption kinetics measurements. The Langmuir, Freundlich and Temkin isotherms were applied to analyze the equilibrium data. The thermodynamic analysis of adsorption isotherms was performed. A number of equations and kinetic models were used to describe the adsorption rate data, including pseudo-first (PFOE) and pseudo-second (PSOE) order kinetic equations. The obtained test results show that the synthesized biomaterial, compared to pure chitosan, is characterized by greater resistance to high temperatures. Moreover, this biomaterial had excellent adsorption properties. For the adsorption of Cr (VI), the equilibrium state was reached after 120 min, and the sorption capacity was 455.9 mg/g. In addition, DFT calculations and NCI analyses were performed to get more light on the adsorption mechanism of Cr (VI) on the prepared biocomposite.
    Matched MeSH terms: Biocompatible Materials
  9. Busra FM, Lokanathan Y, Nadzir MM, Saim A, Idrus RBH, Chowdhury SR
    Malays J Med Sci, 2017 Mar;24(2):33-43.
    PMID: 28894402 DOI: 10.21315/mjms2017.24.2.5
    INTRODUCTION: Collagen type I is widely used as a biomaterial for tissue-engineered substitutes. This study aimed to fabricate different three-dimensional (3D) scaffolds using ovine tendon collagen type I (OTC-I), and compare the attachment, proliferation and morphological features of human dermal fibroblasts (HDF) on the scaffolds.

    METHODS: This study was conducted between the years 2014 to 2016 at the Tissue Engineering Centre, UKM Medical Centre. OTC-I was extracted from ovine tendon, and fabricated into 3D scaffolds in the form of sponge, hydrogel and film. A polystyrene surface coated with OTC-I was used as the 2D culture condition. Genipin was used to crosslink the OTC-I. A non-coated polystyrene surface was used as a control. The mechanical strength of OTC-I scaffolds was evaluated. Attachment, proliferation and morphological features of HDF were assessed and compared between conditions.

    RESULTS: The mechanical strength of OTC-I sponge was significantly higher than that of the other scaffolds. OTC-I scaffolds and the coated surface significantly enhanced HDF attachment and proliferation compared to the control, but no differences were observed between the scaffolds and coated surface. In contrast, the morphological features of HDF including spreading, filopodia, lamellipodia and actin cytoskeletal formation differed between conditions.

    CONCLUSION: OTC-I can be moulded into various scaffolds that are biocompatible and thus could be suitable as scaffolds for developing tissue substitutes for clinical applications and in vitro tissue models. However, further study is required to determine the effect of morphological properties on the functional and molecular properties of HDF.

    Matched MeSH terms: Biocompatible Materials
  10. Zulkifli FH, Jahir Hussain FS, Abdull Rasad MS, Mohd Yusoff M
    J Biomater Appl, 2015 Feb;29(7):1014-27.
    PMID: 25186524 DOI: 10.1177/0885328214549818
    The aim of this research is to develop biocompatible nanofibrous mats using hydroxyethyl cellulose with improved cellular adhesion profiles and stability and use these fibrous mats as potential scaffold for skin tissue engineering. Glutaraldehyde was used to treat the scaffolds water insoluble as well as improve their biostability for possible use in biomedical applications. Electrospinning of hydroxyethyl cellulose (5 wt%) with poly(vinyl alcohol) (15 wt%) incorporated with and without collagen was blended at (1:1:1) and (1:1) ratios, respectively, and was evaluated for optimal criteria as tissue engineering scaffolds. The nanofibrous mats were crosslinked and characterized by scanning electron microscope, Fourier transform infrared spectroscopy, differential scanning calorimetry, and thermogravimetric analysis. Scanning electron microscope images showed that the mean diameters of blend nanofibers were gradually increased after chemically crosslinking with glutaraldehyde. Fourier transform infrared spectroscopy was carried out to understand chemical interactions in the presence of aldehyde groups. Thermal characterization results showed that the stability of hydroxyethyl cellulose/poly(vinyl alcohol) and hydroxyethyl cellulose/poly(vinyl alcohol)/collagen nanofibers was increased with glutaraldehyde treatment. Studies on cell-scaffolds interaction were carried out by culturing human fibroblast (hFOB) cells on the nanofibers by assessing the growth, proliferation, and morphologies of cells. The scanning electron microscope results show that better cell proliferation and attachment appeared on hydroxyethyl cellulose/poly(vinyl alcohol)/collagen substrates after 7 days of culturing, thus, promoting the potential of electrospun scaffolds as a promising candidate for tissue engineering applications.
    Matched MeSH terms: Biocompatible Materials/chemistry
  11. Kamalian N, Mirhosseini H, Mustafa S, Manap MY
    Carbohydr Polym, 2014 Oct 13;111:700-6.
    PMID: 25037405 DOI: 10.1016/j.carbpol.2014.05.014
    The main aim of this study was to investigate the effect of different coating materials (i.e. Na-alginate and chitosan) on the viability and release behavior of Bifidobacterium pseudocatenulatum G4 in the simulated gastric fluid (SGF) and simulated intestinal fluid (SIF). This study reports the viability of encapsulated B. pseudocatenulatum G4 coated using different alginate (2-4 g/100mL) and chitosan (0.2-0.8 g/100mL) concentrations. The results indicated that the highest concentration of alginate (4.4142 g/100mL) along with 0.5578 g/100mL chitosan resulted in the highest viability of B. pseudocatenulatum G4. The release behavior of the encapsulated probiotics in SGF (pH 1.5) in 2h followed by 4h in SIF (pH 7.4) was also assessed. The resistance rate of alginate-chitosan capsule in SGF was higher than SIF. The alginate-chitosan encapsulated cells had also more resistance than alginate capsules. The current study revealed that alginate encapsulated B. Pseudocatenulatum G4 exhibited longer survival than its free cells (control).
    Matched MeSH terms: Biocompatible Materials/chemistry*
  12. Askari E, Mehrali M, Metselaar IH, Kadri NA, Rahman MM
    J Mech Behav Biomed Mater, 2012 Aug;12:144-50.
    PMID: 22732480 DOI: 10.1016/j.jmbbm.2012.02.029
    This study describes the synthesis of Al(2)O(3)/SiC/ZrO(2) functionally graded material (FGM) in bio-implants (artificial joints) by electrophoretic deposition (EPD). A suitable suspension that was based on 2-butanone was applied for the EPD of Al(2)O(3)/SiC/ZrO(2), and a pressureless sintering process was applied as a presintering. Hot isostatic pressing (HIP) was used to densify the deposit, with beneficial mechanical properties after 2 h at 1800 °C in Ar atmosphere. The maximum hardness in the outer layer (90 vol.% Al(2)O(3)+10 vol.% SiC) and maximum fracture toughness in the core layer (75 vol.% Al(2)O(3)+10 vol.% SiC + 15 vol.% ZrO(2)) composite were 20.8±0.3 GPa and 8±0.1 MPa m(1/2), respectively. The results, when compared with results from Al(2)O(3)/ZrO(2) FGM, showed that SiC increased the compressive stresses in the outer layers, while the inner layers were under a residual tensile stress.
    Matched MeSH terms: Biocompatible Materials/chemistry*
  13. Kuan CY, Yee-Fung W, Yuen KH, Liong MT
    Crit Rev Food Sci Nutr, 2012;52(1):55-71.
    PMID: 21991990 DOI: 10.1080/10408398.2010.494259
    Nanotechnology is seeing higher propensity in various industries, including food and bioactives. New nanomaterials are constantly being developed from both natural biodegradable polymers of plant and animal origins such as polysaccharides and derivatives, peptides and proteins, lipids and fats, and biocompatible synthetic biopolyester polymers such as polylactic acid (PLA), polyhydroxyalkonoates (PHA), and polycaprolactone (PCL). Applications in food industries include molecular synthesis of new functional food compounds, innovative food packaging, food safety, and security monitoring. The relevance of bioactives includes targeted delivery systems with improved bioavailability using nanostructure vehicles such as association colloids, lipid based nanoencapsulator, nanoemulsions, biopolymeric nanoparticles, nanolaminates, and nanofibers. The extensive use of nanotechnology has led to the need for parallel safety assessment and regulations to protect public health and adverse effects to the environment. This review covers the use of biopolymers in the production of nanomaterials and the propensity of nanotechnology in food and bioactives. The exposure routes of nanoparticles, safety challenges, and measures undertaken to ensure optimal benefits that outweigh detriments are also discussed.
    Matched MeSH terms: Biocompatible Materials/analysis
  14. Wajih WA, Shaharuddin B, Razak NH
    J Oral Maxillofac Surg, 2011 Jun;69(6):1740-4.
    PMID: 21272979 DOI: 10.1016/j.joms.2010.07.053
    A normally restored orbital structure after reconstructive surgery would accelerate the return of orbital function. The aim of the present study was to compare the outcomes of 2 orbital implants: autogenous grafts and porous polyethylene (Medpor).
    Matched MeSH terms: Biocompatible Materials*
  15. Toibah AR, Sopyan I, Mel M
    Med J Malaysia, 2008 Jul;63 Suppl A:83-4.
    PMID: 19024995
    The incorporation of magnesium ions into the calcium phosphate structure is of great interest for the development of artificial bone implants. This paper investigates the preparation of magnesium-doped biphasic calcium phosphate (Mg-BCP) via sol gel method at various concentrations of added Mg. The effect of calcinations temperature (ranging from 500 degrees C to 900 degrees C) and concentrations of Mg incorporated into BCP has been studied by the aid of XRD, TGA and infrared spectroscopy (IR) in transmittance mode analysis. The study indicated that the powder was pure BCP and Mg-BCP with 100% purity and high crystallinity. The results also indicated that beta-tricalcium phosphate (beta-TCP) phase can be observed when the powder was calcined at 800 degrees C and above.
    Matched MeSH terms: Biocompatible Materials/chemistry
  16. Siew EL, Rajab NF, Osman AB, Sudesh K, Inayat-Hussain SH
    J Biomed Mater Res A, 2009 Dec;91(3):786-94.
    PMID: 19051306 DOI: 10.1002/jbm.a.32290
    Polyhydroxyalkanoates (PHA) are naturally occurring biopolyesters that have great potential in the medical field. However, the leachables resulting from sterilization process of the biomaterials may exert toxic effect including genetic damage. Here, we demonstrate that although gamma-irradiation of poly(3-hydroxybutyrate-co-50 mol % 4-hydroxybutyrate) [P(3HB-co-4HB)] did not cause any change in the morphology by scanning electron microscopy, there was a significant degradation of this copolymer where the molecular weight was reduced by 37% after sterilization indicating the generation of leachables. Therefore, further investigation on the ability of the extract of this poststerilized copolymer to induce mutagenic effect was performed using Ames test (S. typhimurium strains TA1535 and TA1537) and umu test (S. typhimurium strain TA1535/pSK1002). Additionally, the capability of the extract to induce clastogenic effect was determined using Chinese hamster lung V79 fibroblast cells. Our results showed that with and without the presence of S9 metabolic activation, no mutagenic effects were observed in both Ames and umu tests when treated with P(3HB-co-4HB) extract. Similarly, treatment of P(3HB-co-4HB) extract in V79 fibroblast cells showed no significant production of micronuclei when compared with the positive control (Mitomycin C). Together, these results indicate that leachables of poststerilized P(3HB-co-4HB) cause no mutagenic and clastogenic effects.
    Matched MeSH terms: Biocompatible Materials/chemistry*
  17. Tai CC, Cross MJ
    J Bone Joint Surg Br, 2006 Sep;88(9):1158-63.
    PMID: 16943464
    We carried out a prospective study of 118 hydroxyapatite-coated, cementless total knee replacements in patients who were = 55 years of age and who had primary (92; 78%) or post-traumatic (26; 22%) osteoarthritis. The mean period of follow-up was 7.9 years (5 to 12.5). The Knee Society clinical scores improved from a pre-operative mean of 98 (0 to 137) to a mean of 185 (135 to 200) at five years, and 173 (137 to 200) at ten years. There were two revisions of the tibial component because of aseptic loosening, and one case of polyethylene wear requiring further surgery. There was no osteolysis or progressive radiological loosening of any other component. At 12 years, the overall rate of implant survival was 97.5% (excluding exchange of spacer) and 92.1% (including exchange of spacer). Cementless total knee replacement can achieve excellent long-term results in young, active patients with osteoarthritis. In contrast to total hip replacement, polyethylene wear, osteolysis and loosening of the prosthesis were not major problems for these patients, although it is possible that this observation could change with longer periods of follow-up.
    Matched MeSH terms: Biocompatible Materials*
  18. Ruszymah BH
    Med J Malaysia, 2004 May;59 Suppl B:30-1.
    PMID: 15468804
    Patient own fibrin may act as the safest, cheapest and immediate available biodegradable scaffold material in clinical 1 tissue engineering. This study investigated the feasibility of using patient own fibrin isolated from whole blood to construct a new human cartilage, skin and bone. Constructed in vitro tissues were implanted on the dorsal part of the nude mice for in vivo maturation. After 8 weeks of implantation, the engineered tissues were removed for histological analysis. Our results demonstrated autologous fibrin has great potential as clinical scaffold material to construct various human tissues.
    Matched MeSH terms: Biocompatible Materials*
  19. Krishnamurithy G, Murali MR, Hamdi M, Abbas AA, Raghavendran HB, Kamarul T
    Regen Med, 2015;10(5):579-90.
    PMID: 26237702 DOI: 10.2217/rme.15.27
    To compare the effect of bovine bone derived porous hydroxyapatite (BDHA) scaffold on proliferation and osteogenic differentiation of human bone marrow-derived mesenchymal stromal cells (hMSCs) compared with commercial hydroxyapatite (CHA) scaffold.
    Matched MeSH terms: Biocompatible Materials/chemistry
  20. Ling BC
    PMID: 11709981
    Standard prosthodontic procedures require five visits to construct a set of complete maxillary and mandibular dentures. Various attempts have been made to reduce these procedures to four or three appointments. However, most of these techniques require the use of visible light polymerized resin as the final denture base materials. Visible light-cured resin materials have inferior physical properties and biocompatibility problems as compared with heat cured polymethylmethacrylate. This paper describes a system of complete denture construction which requires three clinical appointments instead of the usual five visits. This system is made possible by using the VLC base/tray material as the preliminary impression material as well as the application of a new biometric wax occlusion rim. It retains the use of polymethylmethacrylate as the denture base material. This system also utilizes all the procedures used in the conventional five appointment system of complete denture construction.
    Matched MeSH terms: Biocompatible Materials/chemistry