  1. Veloo KV, Ibrahim NAS
    J Sep Sci, 2020 Aug;43(15):3027-3035.
    PMID: 32386268 DOI: 10.1002/jssc.201901237
    A new sol-gel hybrid methyltrimethoxysilane-chloropropyltriethoxysilane was prepared as sorbent for solid-phase extraction. The extraction efficiency of the prepared sol-gel hybrid methyltrimethoxysilane-chloropropyltriethoxysilane was assessed by using three selected organophosphorus pesticides, namely, chlorpyrifos, profenofos, and malathion. Gas chromatography-mass spectrometry was used for detection of organophosphorus pesticides. Several vital parameters were optimized to identify the best extraction conditions. Under the optimum extraction conditions, solid-phase extraction-methyltrimethoxysilane-chloropropyltriethoxysilane method showed good linearity range (0.05-1 μg/mL) with coefficient of determination more than 0.995. The limits of detection obtained were in the range of 0.01-0.07 μg/mL and limits of quantification ranging from 0.03 to 0.21 μg/mL. The limits of detection obtained for the developed method were 2.3-6.5× lower than the limits of detection of commercial octadecyl silica sorbent. Real samples analysis was carried out by applying the developed method on red apple and purple grape samples. The developed method exhibited good recoveries (88.33-120.7%) with low relative standard deviations ranging from 1.6 to 3.3% compared to commercial octadecyl silica sorbent, which showed acceptable recoveries (70.3-100.2%) and relative standard deviations (6.3-8.8%). The solid-phase extraction-methyltrimethoxysilane-chloropropyltriethoxysilane method is presented as an alternative extraction method for determination of organophosphorus pesticides.
  2. Reddy AVB, Yusop Z, Jaafar J, Bin Aris A, Abdul Majid Z
    J Sep Sci, 2017 Aug;40(15):3086-3093.
    PMID: 28581679 DOI: 10.1002/jssc.201700252
    An extremely sensitive and simple gas chromatography with mass spectrometry method was developed and completely validated for the analysis of five process-related impurities, viz., 4-hydroxy-l-phenylglycine, 4-hydroxyphenylacetonitrile, 4-hydroxyphenylacetic acid, methyl-4-hydroxyphenylacetate, and 2-[4-{(2RS)-2-hydroxy-3-[(1-methylethyl)amino]propoxy}phenyl]acetonitrile, in atenolol. The separation of impurities was accomplished on a BPX-5 column with dimensions of 50 m × 0.25 mm i.d. and 0.25 μm film thickness. The method validation was performed following International Conference on Harmonisation guidelines in which the method was capable to quantitate 4-hydroxy-l-phenylglycine, 4-hydroxyphenylacetonitrile, and 4-hydroxyphenylacetic acid at 0.3 ppm, and methyl-4-hydroxyphenylacetate and 2-[4-{(2RS)-2-hydroxy-3-[(1-methylethyl)amino]propoxy}phenyl]acetonitrile at 0.35 ppm with respect to 10 mg/mL of atenolol. The method was linear over the concentration range of 0.3-10 ppm for 4-hydroxy-l-phenylglycine, 4-hydroxyphenylacetonitrile, and 4-hydroxyphenylacetic acid, and 0.35-10 ppm for methyl-4-hydroxyphenylacetate and 2-[4-{(2RS)-2-hydroxy-3-[(1-methylethyl)amino]propoxy}phenyl]acetonitrile. The correlation coefficient in each case was found ≥0.998. The repeatability and recovery values were acceptable, and found between 89.38% and 105.60% for all five impurities under optimized operating conditions. The method developed here is simple, selective, and sensitive with apparently better resolution than the reported methods. Hence, the method is a straightforward and good quality control tool for the quantitation of selected impurities at trace concentrations in atenolol.
  3. Thongprapai P, Cheewasedtham W, Chong KF, Rujiralai T
    J Sep Sci, 2018 Dec;41(23):4348-4354.
    PMID: 30267469 DOI: 10.1002/jssc.201800441
    A magnetic nanographene oxide sorbent as a selective sorbent for the magnetic solid-phase extraction combined with high-performance liquid chromatography and fluorescence detection was developed and proved to be a robust method for zearalenone determination in corn samples. Optimum extraction of zearalenone (20 mg magnetic nanographene oxide sorbent, extraction for 15 min, desorption time of 15 min using 1 mL of 0.5% formic acid in methanol) resulted in low limits of detection (05 mg/L) and quantitation (0.13 mg/L) and good linearity range of 0.13-1.25 mg/L with the correlation coefficient of 0.9957. Acceptable recoveries (79.3-80.6%) with relative standard deviations below 4% and satisfactory intra- and interday precisions (2-7.4%) were achieved. Additionally, the proposed method has been proved to be good in several aspects: easily prepared sorbent with high affinity to zearalenone, convenient and fast procedure, and high extraction efficiency.
  4. Mohd Hassan FW, Muggundha Raoov, Kamaruzaman S, Sanagi MM, Yoshida N, Hirota Y, et al.
    J Sep Sci, 2018 Oct;41(19):3751-3763.
    PMID: 30125466 DOI: 10.1002/jssc.201800326
    This study describes a dispersive liquid-liquid microextraction combined with dispersive solid-phase extraction method based on phenyl-functionalized magnetic sorbent for the preconcentration of polycyclic aromatic hydrocarbons from environmental water, sugarcane juice, and tea samples prior to gas chromatography with mass spectrometry analysis. Several important parameters affecting the extraction efficiency were investigated thoroughly, including the mass of sorbent, type and volume of extraction solvent, extraction time, type of desorption solvent, desorption time, type and amount of salt-induced demulsifier, and sample volume. Under the optimized extraction and gas chromatography-mass spectrometric conditions, the method revealed good linearity (10-100000 ng/L) with coefficient of determination (R2 ) of ≥0.9951, low limits of detection (3-16 ng/L), high enrichment factors (61-239), and satisfactory analyte recoveries (86.3-109.1%) with the relative standard deviations 
  5. Yenugu VMR, Ambavaram VBR, Moniruzzaman M, Madhavi G
    J Sep Sci, 2018 Nov;41(21):3966-3973.
    PMID: 30138541 DOI: 10.1002/jssc.201800626
    In the present study, a sensitive and fully validated liquid chromatography with mass spectrometry method was developed for the quantification of three potential genotoxic impurities in rabeprazole drug substance. The separation was achieved on Symmetry C18 column (100 × 4.6 mm, 3.5 μm) using 0.1% formic acid in water as mobile phase A and acetonitrile as mobile phase B in gradient elution mode at 0.5 mL/min flow rate. Triple quadrupole mass detection with electrospray ionization was operated in selected ion recording mode for the quantification of impurities. The calibration curves were demonstrated good linearity over the concentration range of 1.0-4.5 ppm for O-phenylenediamine, 1.8-4.5 ppm for 4-nitrolutidine-N-oxide and 1.0-4.5 ppm for benzyltriethylammonium chloride with respect to 10 mg/mL of rabeprazole. The correlation coefficient obtained in each case was >0.998. The recoveries were found satisfactory over the range between 94.22 and 106.84% for all selected impurities. The method validation was carried out following International Conference on Harmonization guidelines, from which the developed method was able to quantitate the impurities at 1.0 ppm for O-phenylenediamine, 1.8 ppm for 4-nitrolutidine-N-oxide and 1.0 ppm for benzyltriethylammonium chloride. Furthermore, the proposed method was successfully evaluated for the determination of selected impurities from bulk drug and formulation samples of rabeprazole within the acceptable limits.
  6. Subuhi NEAM, Saad SM, Zain NNM, Lim V, Miskam M, Kamaruzaman S, et al.
    J Sep Sci, 2020 Aug;43(16):3294-3303.
    PMID: 32519432 DOI: 10.1002/jssc.201901194
    In this work, a simple, fast, sensitive, and environmentally friendly method was developed for preconcentration and quantitative measurement of bisphenol A in water samples using gas chromatography with mass spectrometry. The preconcentration approach, namely biosorption-based dispersive liquid-liquid microextraction with extractant removal by magnetic nanoparticles was performed based on the formation of microdroplet of rhamnolipid biosurfactant throughout the aqueous samples, which accelerates the mass transfer process between the extraction solvent and sample solution. The process is then followed by the application of magnetic nanoparticles for easy retrieval of the analyte-containing extraction solvent. Several important variables were optimized comprehensively including type of disperser solvent and desorption solvent, rhamnolipid concentration, volume of disperser solvent, amount of magnetic nanoparticles, extraction time, desorption time, ionic strength, and sample pH. Under the optimized microextraction and gas chromatography with mass spectrometry conditions, the method demonstrated good linearity over the range of 0.5-500 µg/L with a coefficient of determination of R2  = 0.9904, low limit of detection (0.15 µg/L) and limit of quantification (0.50 µg/L) of bisphenol A, good analyte recoveries (84-120%) and acceptable relative standard deviation (1.8-14.9%, n = 6). The proposed method was successfully applied to three environmental water samples, and bisphenol A was detected in all samples.
  7. Ng NT, Kamaruddin AF, Wan Ibrahim WA, Sanagi MM, Abdul Keyon AS
    J Sep Sci, 2018 Jan;41(1):195-208.
    PMID: 28834218 DOI: 10.1002/jssc.201700689
    The efficiency of the extraction and removal of pollutants from food and the environment has been an important issue in analytical science. By incorporating inorganic species into an organic matrix, a new material known as an organic-inorganic hybrid material is formed. As it possesses high selectivity, permeability, and mechanical and chemical stabilities, organic-inorganic hybrid materials constitute an emerging research field and have become popular to serve as sorbents in various separaton science methods. Here, we review recent significant advances in analytical solid-phase extraction employing organic-inorganic composite/nanocomposite sorbents for the extraction of organic and inorganic pollutants from various types of food and environmental matrices. The physicochemical characteristics, extraction properties, and analytical performances of sorbents are discussed; including morphology and surface characteristics, types of functional groups, interaction mechanism, selectivity and sensitivity, accuracy, and regeneration abilities. Organic-inorganic hybrid sorbents combined with extraction techniques are highly promising for sample preparation of various food and environmental matrixes with analytes at trace levels.
  8. Kamaruzaman S, Sanagi MM, Yahaya N, Wan Ibrahim WA, Endud S, Wan Ibrahim WN
    J Sep Sci, 2017 Nov;40(21):4222-4233.
    PMID: 28837263 DOI: 10.1002/jssc.201700549
    A new facile magnetic micro-solid-phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite-MCM-41 as adsorbent. The synthesized sorbent was characterized by several spectroscopic techniques. The maximum extraction efficiency for extraction of 500 μg/L antidepressant drugs from aqueous solution was obtained with 15 mg of magnetite-MCM-41 at pH 12. The analyte was desorbed using 100 μL of acetonitrile prior to gas chromatography determination. This method was rapid in which the adsorption procedure was completed in 60 s. Under the optimized conditions using 15 mL of antidepressant drugs sample, the calibration curve showed good linearity in the range of 0.05-500 μg/L (r2  = 0.996-0.999). Good limits of detection (0.008-0.010 μg/L) were obtained for the analytes with good relative standard deviations of <8.0% (n = 5) for the determination of 0.1, 5.0, and 500.0 μg/L of antidepressant drugs. This method was successfully applied to the determination of amitriptyline and chlorpromazine in plasma and urine samples. The recoveries of spiked plasma and urine samples were in the range of 86.1-115.4%. Results indicate that magnetite micro-solid-phase extraction with gas chromatography and mass spectrometry is a convenient, fast, and economical method for the extraction and determination of amitriptyline and chlorpromazine in biological samples.
  9. Kamaruddin AF, Sanagi MM, Wan Ibrahim WA, Md Shukri DS, Abdul Keyon AS
    J Sep Sci, 2017 Nov;40(21):4256-4263.
    PMID: 28851082 DOI: 10.1002/jssc.201700659
    Polypyrrole-magnetite dispersive micro-solid-phase extraction method combined with ultraviolet-visible spectrophotometry was developed for the determination of selected cationic dyes in textile wastewater. Polypyrrole-magnetite was used as adsorbent due to its thermal stability, magnetic properties, and ability to adsorb Rhodamine 6G and crystal violet. Dispersive micro-solid-phase extraction parameters were optimized, including sample pH, adsorbent amount, extraction time, and desorption solvent. The optimum polypyrrole-magnetite dispersive micro-solid phase-extraction conditions were sample pH 8, 60 mg polypyrrole-magnetite adsorbent, 5 min of extraction time, and acetonitrile as the desorption solvent. Under the optimized conditions, the polypyrrole-magnetite dispersive micro-solid-phase extraction with ultraviolet-visible method showed good linearity in the range of 0.05-7 mg/L (R2  > 0.9980). The method also showed a good limit of detection for the dyes (0.05 mg/L) and good analyte recoveries (97.4-111.3%) with relative standard deviations 
  10. Ng HW, Lee MFX, Chua GK, Gan BK, Tan WS, Ooi CW, et al.
    J Sep Sci, 2018 May;41(10):2119-2129.
    PMID: 29427396 DOI: 10.1002/jssc.201700823
    Hepatitis B virus-like particles expressed in Escherichia coli were purified using anion exchange adsorbents grafted with polymer poly(oligo(ethylene glycol) methacrylate) in flow-through chromatography mode. The virus-like particles were selectively excluded, while the relatively smaller sized host cell proteins were absorbed. The exclusion of virus-like particles was governed by the accessibility of binding sites (the size of adsorbents and the charge of grafted dextran chains) as well as the architecture (branch-chain length) of the grafted polymer. The branch-chain length of grafted polymer was altered by changing the type of monomers used. The larger adsorbent (90 μm) had an approximately twofold increase in the flow-through recovery, as compared to the smaller adsorbent (30 μm). Generally, polymer-grafted adsorbents improved the exclusion of the virus-like particles. Overall, the middle branch-chain length polymer grafted on larger adsorbent showed optimal performance at 92% flow-through recovery with a purification factor of 1.53. A comparative study between the adsorbent with dextran grafts and the polymer-grafted adsorbent showed that a better exclusion of virus-like particles was achieved with the absorbent grafted with inert polymer. The grafted polymer was also shown to reduce strong interaction between binding sites and virus-like particles, which preserved the particles' structure.
  11. Razak MR, Aris AZ, Sukatis FF, Zaki MRM, Zainuddin AH, Haron DEM, et al.
    J Sep Sci, 2023 Jan;46(1):e2200282.
    PMID: 36337037 DOI: 10.1002/jssc.202200282
    In toxicological analysis, the analytical validation method is important to assess the exact risk of contaminants of emerging concern in the environment. Syringe filters are mainly used to remove impurities from sample solutions. However, the loss of analyte to the syringe filter could be considerable, causing an underestimate of the analyte concentrations. The current study develops and validates simultaneous liquid chromatography-mass spectrometry analysis using a direct filtration method to detect four groups of contaminants of emerging concern. The adsorption of the analyte onto three different matrices and six types of syringe filters is reported. The lowest adsorption of analytes was observed in methanol (16.72%), followed by deionized water (48.19%) and filtered surface lake water (48.94%). Irrespective of the type of the matrices, the lowest average adsorption by the syringe filter was observed in the 0.45 μm polypropylene membrane (15.15%), followed by the 0.20 μm polypropylene membrane (16.10%), the 0.20 μm regenerated cellulose (16.15%), the 0.20 μm polytetrafluoroethylene membrane (47.38%), the 0.45 μm nylon membrane (64.87%) and the 0.20 μm nylon membrane (71.30%). In conclusion, the recommended syringe filter membranes for contaminants of emerging concern analysis are polypropylene membranes and regenerated cellulose, regardless of the matrix used.
  12. Wan Ibrahim WN, Sanagi MM, Mohamad Hanapi NS, Kamaruzaman S, Yahaya N, Wan Ibrahim WA
    J Sep Sci, 2018 Jul;41(14):2942-2951.
    PMID: 29877605 DOI: 10.1002/jssc.201800064
    We describe the preparation, characterization, and application of a composite film adsorbent based on blended agarose-chitosan-multiwalled carbon nanotubes for the preconcentration of selected nonsteroidal anti-inflammatory drugs in aqueous samples before determination by high performance liquid chromatography with ultraviolet detection. The composite film showed a high surface area (4.0258 m2 /g) and strong hydrogen bonding between the multiwalled carbon nanotubes and agarose/chitosan matrix, which prevent adsorbent deactivation and ensure long-term stability. Several parameters, such as sample pH, addition of salt, extraction time, desorption solvent, and concentration of multiwalled carbon nanotubes in the composite film were optimized using a one-factor-at-time approach. The optimum extraction conditions obtained were as follows: isopropanol as conditioning solvent, 10 mL of sample solution at pH 2, extraction time of 30 min, stirring speed of 600 rpm, 100 μL of isopropanol as desorption solvent, desorption time of 5 min under ultrasonication, and 0.4% w/v of composite film. Under the optimized conditions, the calibration curve showed good linearity in the range of 1-500 ng/mL (r2  = 0.997-0.999), and good limits of detection (0.89-8.05 ng/mL) were obtained with good relative standard deviations of
  13. Malek SK, Nodeh HR, Akbari-Adergani B
    J Sep Sci, 2018 Jul;41(14):2934-2941.
    PMID: 29877604 DOI: 10.1002/jssc.201800090
    The precise control of pesticide residues in foodstuffs depends significantly on the clean extraction of analytes using specifically designed separation methods. In this study, a one-pot sol-gel process was used for the preparation of a magnetic hybrid silica gel tetraethylortho silicate-cyanopropyltriethoxy silane nanocomposite. The prepared material was characterized using energy dispersive X-ray spectroscopy, Fourier transform infrared spectroscopy, single-point specific surface area, and scanning electron microcopy. The synthesized magnetic hybrid material was used as a solid phase extraction sorbent for the extraction and preconcentration of some organophosphorus pesticides before gas chromatography with a microelectron capture detector. The performance of the proposed magnetic solid-phase extraction technique was validated by linearity (0.05-2 ng/mL), correlation coefficients (r2  = 0.9993-0.9997), limit of detection (0.02-0.06 ng/mL, S/N = 3, n = 3), and intraday (RSD = 1.5-8.7%, n = 3) and interday precision (RSD = 5.5-9.3%, n = 12), while the recovery in real samples and equilibrium adsorption capacity was 72.02-103.84% and 8-20 mg/g, respectively. The magnetic solid-phase extraction based on the hybrid nanocomposite revealed a high enrichment factor, an appropriate dynamic range, and great absorptive ability toward the selected organophosphorus pesticides spiked in real water samples.
  14. Rahmawati R, Hartati YW, Latip JB, Herlina T
    J Sep Sci, 2023 Jun;46(12):e2200800.
    PMID: 36715692 DOI: 10.1002/jssc.202200800
    Plants in the genus Erythrina is a potential source of chemical constituents, one of which is flavonoids, which have diverse bioactivities. To date, literature on the flavonoids from the genus Erythrina has only highlighted the phytochemical aspects, so this review article will discuss isolation techniques and strategies for the first time. More than 420 flavonoids have been reported in the Erythrina genus, which are grouped into 17 categories. These flavonoid compounds were obtained through isolation techniques and strategies using polar, semi-polar, and non-polar solvents. Various chromatographic techniques have been developed to isolate flavonoids using column flash chromatography, quick column chromatography, centrifugally accelerated thin-layer chromatography, radial chromatography, medium-pressure column chromatography, semi-preparative high-performance liquid chromatography, and preparative high-performance liquid chromatography. Chromatographic processes for isolating flavonoids can be optimized using multivariate statistical applications such as response surface methodology with central composite design, Box-Behnken design, Doehlert design, and mixture design.
  15. Ng MH, Nu'man AH, Hasliyanti A
    J Sep Sci, 2024 Feb;47(4):e2300842.
    PMID: 38403445 DOI: 10.1002/jssc.202300842
    The study explored ferulic acid extraction from palm empty fruit bunch (EFB) fiber using deep eutectic solvent (DES) of chlorine chloride-acetic acid as the extraction medium and the way to recover and recycle the DES thereafter. Antisolvent was added to selectively precipitate the ferulic acid, which was recovered by filtration thereafter. Recycling the DES without further purification led to increased ferulic acid yield with each subsequent extraction, likely due to retained ferulic acid. The retained ferulic acid and other impurities could be removed by precipitation brought upon by the addition of a second antisolvent. 1H nuclear magnetic resonance revealed that there was no excess ferulic acid in the recycled DES-treated with two types of antisolvents (ethanol and water). The yield of ferulic acid increased from 0.1367-0.1856 g/g when treated with only one antisolvent to 0.1368-0.2897 g/g with two antisolvent treatments. Oil droplets were also observed in the DES upon the addition of antisolvent 2, with recovered oil ranging from 0.6% to 3%. The study emphasized the significance of using DES as an extraction medium for ferulic acid from oil palm EFB fiber and the method to recycle the DES for subsequent processes.