Displaying publications 21 - 40 of 61 in total

Abstract:
Sort:
  1. Tan WY, Ng JZL, Ajit Bapat R, Vijaykumar Chaubal T, Kishor Kanneppedy S
    J Prosthet Dent, 2021 May;125(5):766.e1-766.e8.
    PMID: 33752904 DOI: 10.1016/j.prosdent.2021.02.018
    STATEMENT OF PROBLEM: Lingual plate perforation can be life-threatening when vital structures are damaged during implant placement. Knowledge of the anatomy of lingual concavities is imperative for safe implant surgery.

    PURPOSE: The purpose of this clinical study was to determine the prevalence of type of posterior mandibular ridge morphology in a Malaysian population and to evaluate the buccolingual width of the alveolar ridge (Wb and Wc); alveolar ridge height (Vcb); and concavity angle, length, and depth for both left and right first and second molars in different age groups and sexes by using cone beam computed tomography (CBCT).

    MATERIAL AND METHODS: Bilateral posterior mandibular lingual concavities at the first and second molars were retrospectively studied in cross-sectional views of 150 CBCT scans (n=600 sites evaluated). The sample size was calculated at a power of 80%, confidence interval of 95%, and margin of error of .05. The buccolingual width from the base and crest of the ridge and the ridge height were measured to determine the type of ridge. For the U-shaped ridge, the concavity angle, length, and depth were assessed. The independent t test was used to compare mean values of CBCT measurements between sexes and tooth type, while the ANOVA and Pearson chi-squared test were used to determine the correlations with age groups and types of ridge morphology, respectively. To compare the left and right readings for first and second molars in the same patient, the paired t test was performed (α=.05 for all tests).

    RESULTS: The Pearson correlation showed a strong agreement between the 2 examiners with an interobserver reliability of 87.3%. Significant difference was noted in all dimensional measurements when comparing right and left first and second molars (P

  2. Rahman AM, Jamayet NB, Nizami MMUI, Johari Y, Husein A, Alam MK
    J Prosthet Dent, 2021 Jan 17.
    PMID: 33472753 DOI: 10.1016/j.prosdent.2020.07.026
    STATEMENT OF PROBLEM: The climate of tropical Southeast Asia includes high humidity and ultraviolet radiation that reduce the lifespan of silicone prostheses by inducing changes in their mechanical properties and color stability. Studies on the surface roughness (SR) and mechanical properties of different silicone elastomers (SEs) subjected to the natural tropical weather of Southeast Asia are lacking.

    PURPOSE: The purpose of this in vitro study was to evaluate the SR, tensile strength (TS), and percentage elongation (% E) of different SEs subjected to outdoor weathering in the Malaysian climate.

    MATERIAL AND METHODS: Type-II dumbbell-shaped specimens (N-120) (nonweathered=15, weathered=15) were made from 3 room-temperature vulcanized (A-2000, A-2006, and A-103) and 1 heat-temperature vulcanized (M-511) silicone (Factor II). For 6 months, weathered specimens were subjected to outdoor weathering inside a custom exposure rack. Simultaneously, the nonweathered specimens were kept in a dehumidifier. Subsequently, the SR was measured with a profilometer; TS and % E were measured by using a universal testing machine. Two-way ANOVA was used to compare the means of the tested properties of the nonweathered and weathered specimens, and pairwise comparison was carried out between the silicones (α=.05).

    RESULTS: After outdoor weathering, the SR, TS, and % E were adversely affected by weathering in the Malaysian environment. Among the silicone materials, A-2000 showed the least TS changes (2.51 MPa), while A-2006 demonstrated significant changes in percentage elongation after outdoor weathering (266.5%). M-511 exhibited the highest mean value (2.50 μm) for SR changes. In addition, A-103 SE showed statistically significant differences in most pairwise comparisons for all 3 dependent variables.

    CONCLUSIONS: Based on the evaluation of mechanical properties, A-103 can be suggested as a suitable silicone for maxillofacial prostheses fabricated for tropical climates. However, A-2000 can be a suitable alternative, although significant changes to surface roughness were detected after outdoor weathering.

  3. Idris RI, Shoji Y, Lim TW
    J Prosthet Dent, 2021 Jan 14.
    PMID: 33455729 DOI: 10.1016/j.prosdent.2020.11.035
    STATEMENT OF PROBLEM: Space creation for a metal retainer of the resin-bonded fixed partial dental prostheses (RBFPDPs) with the Dahl concept remains controversial because of the lack of clinical studies.

    PURPOSE: The purpose of this clinical study was to investigate the occlusal force and occlusal contact reestablishment of RBFPDPs cemented at an increased occlusal vertical dimension (the Dahl concept) and to evaluate the factors affecting them.

    MATERIAL AND METHODS: A prospective clinical study was carried out on 28 participants receiving cantilevered RBFPDPs at an increased occlusal vertical dimension at the Faculty of Dentistry, University Teknologi MARA. Maximum occlusal forces were recorded at precementation, postcementation, and 12-week review visit by using pressure indicating film, while occlusal contact reestablishment was assessed at the precementation stage and 12-week review visit by using shim stock foils. The Wilcoxon signed-rank and chi-squared tests were used for statistical analysis (α=.05).

    RESULTS: Significant differences were found for maximum occlusal force between the precementation and the postcementation and between the postcementation and the 12-week review of RBFPDPs (P.05).

    CONCLUSIONS: Overall, occlusal force was reestablished after 12 weeks, and occlusal contact was completely reestablished in most participants after placement of RBFPDPs at an increased occlusal vertical dimension.

  4. Farook TH, Abdullah JY, Jamayet NB, Alam MK
    J Prosthet Dent, 2021 Feb 15.
    PMID: 33602541 DOI: 10.1016/j.prosdent.2020.07.039
    STATEMENT OF PROBLEM: Computer-aided design (CAD) of maxillofacial prostheses is a hardware-intensive process. The greater the mesh detail is, the more processing power is required from the computer. A reduction in mesh quality has been shown to reduce workload on computers, yet no reference value of reduction is present for intraoral prostheses that can be applied during the design.

    PURPOSE: The purpose of this simulation study was to establish a reference percentage value that can be used to effectively reduce the size and polygons of the 3D mesh without drastically affecting the dimensions of the prosthesis itself.

    MATERIAL AND METHODS: Fifteen different maxillary palatal defects were simulated on a dental cast and scanned to create 3D casts. Digital bulbs were fabricated from the casts. Conventional bulbs for the defects were fabricated, scanned, and compared with the digital bulb to serve as a control. The polygon parameters of digital bulbs were then reduced by different percentages (75%, 50%, 25%, 10%, 5%, and 1% of the original mesh) which created a total of 105 meshes across 7 mesh groups. The reduced mesh files were compared individually with the original design in an open-source point cloud comparison software program. The parameters of comparison used in this study were Hausdorff distance (HD), Dice similarity coefficient (DSC), and volume.

    RESULTS: The reduction in file size was directly proportional to the amount of mesh reduction. There were minute yet insignificant differences in volume (P>.05) across all mesh groups, with significant differences (P

  5. Sivakumar I, Arunachalam S, Choudhary S, Buzayan MM
    J Prosthet Dent, 2021 Jun;125(6):862-869.
    PMID: 32694022 DOI: 10.1016/j.prosdent.2020.04.001
    STATEMENT OF PROBLEM: Immunosuppression and coinfections associated with human immunodeficiency virus (HIV) infection pose a relative contraindication for dental implant therapy. However, although implants have been placed in patients with HIV with reasonable success, how HIV infection affects their survival is unclear.

    PURPOSE: The purpose of this systematic review of the literature and meta-analysis was to analyze the data on the survival of dental implants in patients with HIV.

    MATERIAL AND METHODS: A search for relevant articles published up to November 2019 was performed in PubMed/Medline and Cochrane databases, Clinicaltrials.gov, and Google Scholar. Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were adopted for the conduct of the systematic review. The most pertinent data were extracted and pooled for qualitative and quantitative analyses with 95% confidence intervals. Heterogeneity was analyzed by using I-squared statistics.

    RESULTS: A total of 8 studies involving 411 individuals with HIV and 1109 implants were included in the meta-analysis. The mean follow-up period was 2.8 years. A pooled estimate of 95% of implant survival rate with 95% confidence interval(92% to 96%) was noted. Heterogeneity across the 8 studies was found to be 41% with moderate true variability.

    CONCLUSIONS: This systematic review demonstrated that HIV infection does not pose a serious threat to implant survival on short-term evaluation, but the evidence is of low quality.

  6. Ahmed N, Halim MS, Khalid S, Ghani ZA, Jamayet NB
    J Prosthet Dent, 2021 Jul 31.
    PMID: 34340826 DOI: 10.1016/j.prosdent.2021.06.015
    STATEMENT OF PROBLEM: The color and form of teeth are 2 of the 3 main determinants of success in an esthetic restoration; the third is dental proportion. A recent systematic review of the literature devoted to the evaluation of dental proportion is lacking.

    PURPOSE: The purpose of this systematic review was to investigate the quality and outcome of studies into maxillary anterior tooth proportion and to determine whether dental proportion ratios based on different geographic regions are appropriate.

    MATERIAL AND METHODS: An electronic search was conducted using PubMed, MEDLINE, Google Scholar, Embase, Scopus, Cochrane Library, Web of Science, and Science Direct databases. English-language articles reporting with the specific combination of medical subject heading (MeSH) key words were analyzed by 2 investigators. The titles, full text, and abstracts were scanned by investigators independently to identify articles that fulfilled the inclusion criteria. The general characteristics, outcomes, and quality of each study were reviewed and analyzed systematically.

    RESULTS: The search plan resulted in a total of 73 articles until September 2020; of which, 16 articles fulfilling the inclusion criteria were selected. The geographic distribution of the selected article revealed 12 articles from Asia, 2 from Continental Europe, and 2 from the United Kingdom. Golden percentage values of 25%, 15%, and 10% for central, lateral incisor, and canine teeth were not found. The mean predicted dental percentage was either larger or smaller than the successive widths of maxillary natural anterior teeth.

    CONCLUSIONS: The golden percentage could not be used to formulate a smile design. Rather, the dental ratios should be set on a racial and ethnic basis for a population.

  7. Alhajj MN, Al-Sanabani FA, Alkheraif AA, Smran A, Alqerban A, Samran A
    J Prosthet Dent, 2021 Jun 23.
    PMID: 34175112 DOI: 10.1016/j.prosdent.2021.05.013
    STATEMENT OF PROBLEM: A comprehensive bibliometric analysis to determine different aspects of the Journal of Prosthetic Dentistry is lacking.

    PURPOSE: The purpose of this bibliometric study was to analyze the characteristics of the Journal of Prosthetic Dentistry between 1970 and 2019.

    MATERIAL AND METHODS: The Web of Science Core Collection was used to retrieve 9 categories of the Journal of Prosthetic Dentistry, including keywords and terms used, cited documents published, the countries and organizations of the authors, references, and sources cited during this period. Data were exported to a software program and analyzed for each 10-year period and for the entire 50 years. The highest 10 in each category were reported. Co-occurrence, couthorships, and linkage were also reported.

    RESULTS: A total of 11 989 records were reached by the search on the Web of Science Core Collection database; of which, 10 638 (92.9%) were included in the analysis. Articles made up 91.1%, of all records, with 217 review documents (1.8%). The most productive decade was 1980 to 1989 with 2936 documents. The total number of citations of all documents (available period 1980 to 2019) including self-citations was 155 112. During the period 1970 to 2019, 14 837 terms were used. The total number of keywords was 4933 (available period 1990 to 2019). There were 15 382 authors, 82 countries, and 2113 organizations identified in articles published in the Journal of Prosthetic Dentistry during this period, with most from the United States. There were 43 027 authors, 95 324 references, and 14 594 sources cited in the Journal of Prosthetic Dentistry during the period surveyed.

    CONCLUSIONS: This bibliometric analysis provided a comprehensive overview of the impactful role of the Journal of Prosthetic Dentistry in contemporary dentistry, particularly in the field of prosthodontics.

  8. Jadhav V, Deshpande S, Radke U, Mahale H, Patil PG
    J Prosthet Dent, 2021 Oct;126(4):590-594.
    PMID: 33012529 DOI: 10.1016/j.prosdent.2020.07.014
    STATEMENT OF PROBLEM: Xerostomia refers to the decrease in the quality and quantity of saliva. In denture wearers, xerostomia affects the retention of the denture because of lack of wettability of the denture base. However, which denture base resin materials are best wetted by artificial salivary substitutes is unclear.

    PURPOSE: The purpose of this in vitro study was to determine the wetting properties of 3 different commercially available denture base resin materials with artificial salivary substitute by using contact angle measurements and to compare these properties before and after thermocycling.

    MATERIAL AND METHODS: A total 120 specimens were fabricated with 3 different denture base materials (n=40): heat-polymerized polymethylmethacrylate (DenTek), injection-molded nylon polyamide (Valplast), and microwave polymerized (VIPI WAVE). The advancing and receding contact angles were measured with a goniometer by using the WinDrop++ software program. The contact angle hysteresis was calculated from the advancing and receding contact angles values. The same specimens were subjected to thermocycling to measure the advancing and receding contact angles values. The comparative evaluation was carried out before and after thermocycling.

    RESULTS: The mean ±standard deviation contact angles of the microwave-polymerized material were (62.40 ±1.21 degrees) advancing contact angle, (32.12 ±0.66 degrees) receding contact angle, and (30.28 ±1.40 degrees) contact angle of hysteresis. It was followed by the injection-molded nylon polyamide material, whose mean ±standard deviation contact angle values were (68.57 ±1.72 degrees) advancing contact angle, (43.02 ±1.39 degrees) receding contact angle, (26.27 ±2.05 degrees) contact angle hysteresis and high impact strength heat-polymerized polymethylmethacrylate material, whose mean ±standard deviation contact angle values were (69.81 ±0.16 degrees) advancing contact angle, (41.90 ±1.02 degrees) receding contact angle, and (27.91 ±0.97 degrees) contact angle hysteresis. The statistical analysis showed significant differences among contact angle values of the microwave-polymerized material as compared with the heat-polymerized polymethylmethacrylate and injection-molded nylon polyamide materials (P

  9. Jaiswal N, Patil PG, Gangurde A, Parkhedkar RD
    J Prosthet Dent, 2019 Mar;121(3):517-522.
    PMID: 30391058 DOI: 10.1016/j.prosdent.2018.03.037
    STATEMENT OF PROBLEM: The prosthodontic problems faced by a patient with xerostomia are of great concern. To aid in retention, artificial saliva substitutes should exhibit good wettability on the denture base.

    PURPOSE: The purpose of this in vitro study was to evaluate the wettability of 3 different artificial saliva substitutes on heat-polymerized acrylic resin and to compare these properties with natural saliva and distilled water.

    MATERIAL AND METHODS: A total of 150 heat-polymerized acrylic resin specimens were prepared with 25×15×2 mm dimensions. The specimens were divided into 5 groups (n=30): human saliva, distilled water, Aqwet, Mouth Kote, and Stoppers 4. The advancing and receding contact angle values were measured by using a goniometer, and the contact angle hysteresis and equilibrium angle were calculated. One-way ANOVA and the Bonferroni multiple comparisons test were performed to determine the difference between contact angle values among the groups (α=.05).

    RESULTS: The means of the 5 groups differed significantly (P

  10. Khalid T, Yunus N, Ibrahim N, Saleh NBM, Goode D, Masood M
    J Prosthet Dent, 2020 Dec;124(6):674-681.
    PMID: 31952858 DOI: 10.1016/j.prosdent.2019.08.005
    STATEMENT OF PROBLEM: Wearers of mandibular complete dentures (CDs) often complain of retention and stability problems resulting in poor masticatory function. Evidence suggests that a mandibular overdenture (MOD) stabilized by 2 implants represents the treatment of choice to improve stability and masticatory function. Measurements are needed of the improvement in masticatory function after providing mandibular implant-stabilized overdentures.

    PURPOSE: The purpose of this prospective clinical study was to evaluate the changes in masticatory function from baseline (T0) to 3 months (T1) and 3 years (T2) in participants with MODs and to assess the effect of baseline mandibular bone height and volume on masticatory function after 3 years.

    MATERIAL AND METHODS: Participants were assessed for masticatory function by using masticatory performance involving paraffin wax cubes as an objective measure and by using masticatory ability involving a questionnaire as a subjective measure. Edentulous individuals presenting for replacement dentures were provided with conventional mucosa-supported prostheses and evaluated for masticatory function after a 3-month settling-in period (baseline measure). Before implant placement, baseline measures of bone height and volume were recorded from cone beam computed tomography (CBCT) images. The prostheses were then converted to implant-stabilized mandibular overdentures while any maxillary prostheses remained supported by the mucosa. Masticatory function was reassessed at 3 months and 3 years after insertion of the mandibular overdentures, and the mean changes from baseline were analyzed with the Wilcoxon signed-rank test. The effect of variables on masticatory function was determined by using multivariate linear regression analyses.

    RESULTS: A total of 23 participants were included in the study, with only 1 participant not completing the 3-year assessment. Significant improvement was observed in the masticatory performance (mixing ability index) (P

  11. Yousof Y, Salleh NM, Yusof F
    J Prosthet Dent, 2019 Jun;121(6):916-921.
    PMID: 30745100 DOI: 10.1016/j.prosdent.2018.09.005
    STATEMENT OF PROBLEM: The 2-color mixing ability test has been recently introduced for objective assessment of masticatory performance. However, the ideal bicolor specimens have not yet been identified, and the color analysis of digital images requires improvement.

    PURPOSE: The purpose of this clinical study was to formulate a custom-made, 2-color chewing gum for the mixing ability test and to develop an image-processing method for color mixing analysis.

    MATERIAL AND METHODS: Specimens of red-green (RG) chewing gum were prepared as a test food. Twenty dentate participants (10 men, 10 women; mean age 21 years) took part in this study. Each participant masticated 1 piece of RG gum for 3, 6, 9, 15, and 25 cycles, and this task was repeated 3 times consecutively (total n=15 for each participant). The boluses were retrieved and flattened to 1-mm-thick wafers and scanned with a flatbed scanner. The digital images were analyzed using ImageJ software equipped with a custom-built plug-in to measure the geometric dispersion (GD) of baseline red segment. The predictive criterion validity of this method was determined by correlating GD to the number of mastication cycles. The hardness and mass of RG chewing gum were measured before and after mastication. Hardness loss (%) and mass loss (%) were then calculated and compared with those of a commercially available chewing gum.

    RESULTS: The 2-way repeated-measures ANOVA with post hoc Bonferroni test showed that GD was able to discriminate among the groups of different numbers of mastication cycles (P

  12. Jamayet NB, Farook TH, Al-Oulabi A, Johari Y, Patil PG
    J Prosthet Dent, 2021 Oct 08.
    PMID: 34635339 DOI: 10.1016/j.prosdent.2021.08.021
    This clinical report describes how a hollow obturator prosthesis was designed and fabricated for an 82-year-old partially edentulous patient with a large palatal defect. Computer-aided design (CAD) was used to design, articulate, and align the mandibular denture with the obturator prosthesis. The prosthesis was printed, adjusted chairside, rescanned, and made hollow by using a CAD software program. The prosthesis was printed in resin with a dental 3D printer. Quantitative evaluations of clinical (prosthesis dimensions, rest, and occlusal vertical dimensions) and virtual (surface area, volume, weight, interpoint mismatches, spatial overlap) parameters found that the 3D-printed prosthesis required an additional 5% chairside modification. The greatest differences in volume (24.7% less) and weight (22.2% less) were observed when the modified obturator bulb was made hollow via CAD. Hollowing the bulb, therefore, reduced the spatial overlap in volume by 16.8%.
  13. Farook TH, Rashid F, Jamayet NB, Abdullah JY, Dudley J, Khursheed Alam M
    J Prosthet Dent, 2022 Oct;128(4):830-836.
    PMID: 33642077 DOI: 10.1016/j.prosdent.2020.12.041
    STATEMENT OF PROBLEM: The anatomic complexity of the ear challenges conventional maxillofacial prosthetic rehabilitation. The introduction of specialized scanning hardware integrated into computer-aided design and computer-aided manufacturing (CAD-CAM) workflows has mitigated these challenges. Currently, the scanning hardware required for digital data acquisition is expensive and not readily available for prosthodontists in developing regions.

    PURPOSE: The purpose of this virtual analysis study was to compare the accuracy and precision of 3-dimensional (3D) ear models generated by scanning gypsum casts with a smartphone camera and a desktop laser scanner.

    MATERIAL AND METHODS: Six ear casts were fabricated from green dental gypsum and scanned with a laser scanner. The resultant 3D models were exported as standard tessellation language (STL) files. A stereophotogrammetry system was fabricated by using a motorized turntable and an automated microcontroller photograph capturing interface. A total of 48 images were captured from 2 angles on the arc (20 degrees and 40 degrees from the base of the turntable) with an image overlap of 15 degrees, controlled by a stepper motor. Ear 1 was placed on the turntable and captured 5 times with smartphone 1 and tested for precision. Then, ears 1 to 6 were scanned once with a laser scanner and with smartphones 1 and 2. The images were converted into 3D casts and compared for accuracy against their laser scanned counterparts for surface area, volume, interpoint mismatches, and spatial overlap. Acceptability thresholds were set at <0.5 mm for interpoint mismatches and >0.70 for spatial overlap.

    RESULTS: The test for smartphone precision in comparison with that of the laser scanner showed a difference in surface area of 774.22 ±295.27 mm2 (6.9% less area) and in volume of 4228.60 ±2276.89 mm3 (13.4% more volume). Both acceptability thresholds were also met. The test for accuracy among smartphones 1, 2, and the laser scanner showed no statistically significant differences (P>.05) in all 4 parameters among the groups while also meeting both acceptability thresholds.

    CONCLUSIONS: Smartphone cameras used to capture 48 overlapping gypsum cast ear images in a controlled environment generated 3D models parametrically similar to those produced by standard laser scanners.

  14. Kher U, Tunkiwala A, Patil PG
    J Prosthet Dent, 2022 Jan;127(1):6-14.
    PMID: 33243475 DOI: 10.1016/j.prosdent.2020.09.023
    Implant-supported fixed prostheses in the edentulous maxilla can be difficult because of anatomic limitations and high esthetic demand. The choice between cement and screw retention depends on factors such as esthetics, occlusion, retrievability, and passivity. The choice is also often governed by the ability to manage technical or biologic complications. In the edentulous maxilla, because of the bone trajectory and resorption pattern, unfavorable implant angulations may be encountered. In such situations, a conventional screw-retained prosthesis is difficult to design. This article describes the restoration of edentulous maxillae for a series of patients with different complete-arch fixed prosthesis designs. The clinical guidelines, including indications, advantages, and limitations of each design, were discussed.
  15. Kamarudin KH, Hattori M, Sumita YI, Taniguchi H
    J Prosthet Dent, 2017 Sep 06.
    PMID: 28888415 DOI: 10.1016/j.prosdent.2017.06.005
    A surgical obturator may need to be modified during the healing process after tissue resection. Apart from relining the fitting surfaces to accommodate the healing wound and changes in the surrounding tissues, other modifications such as adding teeth are sometimes required to improve esthetics and speech. This article describes a chairside technique to add customized acrylic resin teeth to an existing surgical obturator.
  16. Voon YS, Patil PG
    J Prosthet Dent, 2018 Apr;119(4):568-573.
    PMID: 28838820 DOI: 10.1016/j.prosdent.2017.05.011
    STATEMENT OF PROBLEM: The genial tubercle is a clinically palpable landmark in the mandible and can be identified in cone beam computed tomography (CBCT). Its location can be used to measure the safe zone in the interforaminal region of the mandible. These measurements may be helpful for implant treatment planning in patients with complete edentulism.

    PURPOSE: The purpose of this clinical study was to evaluate the safe distance in the interforaminal region of the mandible measured from the genial tubercle level for implant osteotomy in a Chinese-Malaysian population.

    MATERIAL AND METHODS: A total of 201 Digital Imaging and Communications in Medicine (DICOM) files were selected for the study from the CBCTs of dentate or edentulous Chinese-Malaysian adult patients with ongoing or completed treatments. Measurements were made with implant planning software. The anatomy of the whole mandible was assessed in the coronal cross-sectional, horizontal view and in panoramic view. Measurements were obtained in millimeters on one side by locating and marking a genial tubercle and then marking the mesial margin of the mental foramen and the anterior loop of the inferior alveolar nerve. The corresponding points of these landmarks were identified on the crest of the mandibular ridge to measure the linear distances. All the measurement steps were repeated on the other side. The linear distance of 2 mm was deducted from the total distance between the genial tubercle and the anterior loop separately for left and right side measurements to identify the safe zone. The mixed 2-way analysis of variance (ANOVA) test was used to analyze side and sex-related variations.

    RESULTS: The mean safe zone measured at the crestal level from the genial tubercle site on the left side of the mandible was 21.12 mm and 21.67 mm on the right side. A statistically significant (P

  17. Wong SK, Patil PG
    J Prosthet Dent, 2018 Aug;120(2):210-213.
    PMID: 29551376 DOI: 10.1016/j.prosdent.2017.10.019
    STATEMENT OF PROBLEM: The inferior alveolar nerve (IAN) frequently loops backward before exiting from the mental foramen and spreads several millimeters medially to the foramen. Implant placement in this area may damage the nerve if the anterior loop area is not carefully identified in a radiographic or computed tomography (CT) evaluation.

    PURPOSE: The purpose of this observational study was to measure the prevalence of the presence of the anterior loop and to estimate sex and ethnicity-related variations in anterior loop length in the Malaysian population.

    MATERIAL AND METHODS: A total of 100 cone beam computed tomography (CBCT) Digital Imaging and Communications in Medicine (DICOM) files were selected from a pool of 810 ongoing or completed patients in 3 different ethnic groups: Malay (33), Indian (33), and Chinese (34). The DICOM data were imported into commercial software. The IAN was traced with software along with the anterior loop and part of the incisive nerve. The vertical length of the nerve was estimated from the canal to the opening of the mental foramen from the cross-sectional view and translated to the panoramic view. Measurement was made from this point to the most anterior point of the anterior loop by following the trajectory of the nerve and was repeated on the opposite side. A 2-way mixed analysis of variance (ANOVA) test was carried out to evaluate the sex- and ethnicity-related variations (α=.05).

    RESULTS: The anterior loop was present in 94% of the 100 participants. Overall anterior loop length (AnLL) ranged between 0.73 and 7.99 mm with a mean length of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side. Among all participants, no statistically significant differences were found between the left and right sides of the mandible (P=.379). Overall, no significant main effect of ethnicity (P=.869) or sex (P=.576) was found on AnLL measurements. Also, with multiple comparisons, no significant effect was found between each pair of ethnic groups. Men in all 3 ethnic groups had greater AnLL than women.

    CONCLUSIONS: The anterior loop was present in 94% of the 100 participants among the 3 major ethnic groups of Malaysia. Overall AnLL ranged between 0.73 and 7.99 mm and mean lengths of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side, with no significant ethnicity- or sex-related variations.

Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links